• Title/Summary/Keyword: Recovery Force

Search Result 245, Processing Time 0.022 seconds

Feedback Flow Control Using Artificial Neural Network for Pressure Drag Reduction on the NACA0015 Airfoil (NACA0015 익형의 압력항력 감소를 위한 인공신경망 기반의 피드백 유동 제어)

  • Baek, Ji-Hye;Park, Soo-Hyung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.9
    • /
    • pp.729-738
    • /
    • 2021
  • Feedback flow control using an artificial neural network was numerically investigated for NACA0015 Airfoil to suppress flow separation on an airfoil. In order to achieve goal of flow control which is aimed to reduce the size of separation on the airfoil, Blowing&Suction actuator was implemented near the separation point. In the system modeling step, the proper orthogonal decomposition was applied to the pressure field. Then, some POD modes that are necessary for flow control are extracted to analyze the unsteady characteristics. NARX neural network based on decomposed modes are trained to represent the flow dynamics and finally operated in the feedback control loop. Predicted control signal was numerically applied on CFD simulation so that control effect was analyzed through comparing the characteristic of aerodynamic force and spatial modes depending on the presence of the control. The feedback control showed effectiveness in pressure drag reduction up to 29%. Numerical results confirm that the effect is due to dramatic pressure recovery around the trailing edge of the airfoil.

An Analysis on Japanese Recession Between 1993 and 2002 (1993~2002년 일본불황에 대한 연구)

  • Yoon, Hyung-Mo
    • International Area Studies Review
    • /
    • v.13 no.2
    • /
    • pp.168-188
    • /
    • 2009
  • Japanese economy suffered from a great recession for one decade between 1993 and 2002, because of the bubble bursting. Recently, a similar situation broke out in the USA and spread throughout the world. This paper investigated the effects of economic policy on the Japanese depression in order to find out how the recession, caused by financial crisis, can be reasonably removed. The analysis of documentary records indicate that there exists an optimum rate in government debt and the point in time of economic policy is decisive. Statistical studies with a VAR model and a State Space Model suggest that government expenditures affect the growth rate of national product but with a short term and it has a time lag of a half year. Income tax has a grievous negative effect on the growth rate with a long term and it works without a time lag. Therefore the increasing of taxation should be put into force very carefully. However private investment is a determinate factor for the recovery of depression.

Behavior of a Shape Memory Alloy Actuator with Composite Strip and Spring (복합재료 스트립과 스프링을 갖는 형상기억합금 작동기의 거동)

  • Heo, Seok;Hwang, Do-Yeon;Choi, Jae-Won;Park, Hoon-Cheol;Goo, Nam-Seo
    • Composites Research
    • /
    • v.22 no.2
    • /
    • pp.37-42
    • /
    • 2009
  • This paper presents an experimental approach to design a bending-type actuator by using a shape memory alloy wire (SMA), composite strip, and spring. The SMA wire is attached to two edges of the bent strip to apply pre-stress to the SMA wire. The spring is used to provide recovery force right after actuation of the SMA wire. To investigate thermo-mechanical characteristics of the SMA wire, a series of DSC tests have been conducted and tensile tests under various levels of pre-stress and input power have been performed. Based on the measured properties of the SMA wire, bending-type actuators are designed and tested for different combination of strip, number of springs, and input power. It has been found that a bending-type actuator with a proper combination shows fast actuation performance and low power consumption.

Thermo-mechanical properties in bending of a multizone nickel-titanium archwire: A retrieval analysis

  • Panagiotis Roulias;Ioulia-Maria Mylonopoulou;Iosif Sifakakis;Christoph Bourauel;Theodore Eliades
    • The korean journal of orthodontics
    • /
    • v.53 no.2
    • /
    • pp.89-98
    • /
    • 2023
  • Objective: This study aimed to compare the mechanical and thermal properties in the anterior and posterior segments of new and retrieved specimens of a commercially available multizone superelastic nickel-titanium (NiTi) archwire. Methods: The following groups of 0.016 × 0.022-inch Bioforce NiTi archwires were compared: a) anterior and b) posterior segments of new specimens and c) anterior and d) posterior segments of retrieved specimens. Six specimens were evaluated in each group, by three-point bending and bend and free recovery tests. Bending moduli (Eb) were calculated. Furthermore, the new specimens were evaluated with scanning electron microscopy/energy-dispersive X-ray spectrometry. A multiple linear regression model with a random intercept at the wire level was applied for data analysis. Results: The forces in the posterior segments or new specimens were higher than those recorded in the anterior segments or retrieved specimens, respectively. Accordingly, Eb also varied. Higher austenite start and austenite finish (Af) temperatures were recorded in the anterior segments. No statistically significant differences were found for these temperatures between retrieved and new wires. The mean elemental composition was (weight percentage): Ni, 52.6 ± 0.5; Ti, 47.4 ± 0.5. Conclusions: The existence of multiple force zones was confirmed in new and retrieved Bioforce archwires. The retrieved archwires demonstrated lower forces during the initial stages of deactivation in three-point bending tests, compared with new specimens. The Af temperature of these archwires may lie higher than the regular intraoral temperature. Even at 2 mm deflections, the forces recorded from these archwires may lie beyond biologically safe limits.

The effect of early loading on the direct bone-to-implant surface contact of the orthodontic osseointegrated titanium implant (교정력이 골유착성 티타니움 임프란트의 초기 고정에 미치는 영향에 관한 실험적 연구)

  • Chung, Kyu-Rhim;Lee, Sung-Ja
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.173-185
    • /
    • 2001
  • The orthodontic osseointegrated titanium implant, a kind of intraoral skeletal anchorage can be an alternative to tooth-borne anchorage, in case that the conventional tooth-borne anchorage is not available or the anchorage is critical. This study was conducted to elucidate the effect of early loading on the osseointegration of the orthodontic titanium implant and the healing process of the impaired bone at the site of implant after removing it. In two adult beagle dogs24 osseointegrated titanium implants were inserted into the alveolar bone, with 12 implants placed in each dog. In dog1, 6 out of 12 implants were loaded with 200-300gm of force immediately after placing, and the remaining 6 implants were not loaded for 4weeks. In dog2, all 12 implants had healing period of 4weeks, and then were loaded with 200-300gm of force for another 4weeks. Following an observation period of 4 and 8 weeks, the animals were sacrificed. Then the implants and the surrounding bone of dog1 and dog2 were removed, respectively. Undecalcified sections along the long axis of implant were made and the degree of osseointegration was examined under the light microscope. The results were as follows. 1. In the histologic features of tissues around implants anchored in dog1, there was no difference between immediately loaded implants and unloaded implants. Immature woven bone was ingrowing into the thread spaces from the original compacta and in direct contact with the implant surface in part. 2. The premature loading just after 4weeks healing period did not halt the progress of the osseointegration between bone and implant surface. The woven bone around the implants was maturing into the lamellar bone which resembled the structure of the original compacta at the end of 8weeks observation period. 3. Most implants with the inflammed surrounding mucosa were lost or mobile. The mobile implants were encapsulated by fibrous connective tissue which separated the implant surface from the bone. 4. The impaired bone at the site of the implant failed to anchor was showing recovery without inflammatory reaction 2weeks after removing, with the immaure woven bone lined by active osteoblasts and osteoid. Based on the results of this study, the integration of this orthodontic implant seemed to be impaired by the inflammation of the tissue surrounding the Implant rather than by early loading on implant, and increased with time lapsed after placing the implant. The use of implant described in this report can be recommended as an orthodontic anchorage unit immediately after insertion under the careful control of orthodontic force applied and plaque.

  • PDF

Assessment of Effect of Pulmonary Rehabilitation on Skeletal Muscle Metabolism by $^{31}P$ Magnetic Resonance Spectroscopy (호흡재활치료 전후 $^{31}P$ 자기공명분석법을 이용한 골격근대사의 변화에 관한 연구)

  • Cho, Won-Kyung;Kim, Dong-Soon;Choe, Kang-Hyeon;Park, Young-Joo;Lim, Tae-Hwan;Shim, Tae-Sun;Lim, Chae-Man;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1040-1050
    • /
    • 1997
  • Pulmonary rehabilitation has been known to improve dyspnea and exercise tolerance in patients with chronic lung disease, although it does not improve pulmonary function. The mechanism of this improvement is not clearly explained till now; however some authors suggested that the improvement in the skeletal muscle metabolism after the rehabilitation could be a possible mechanism. The metabolc changes in skeletal muscle in patients with COPD are characterized by impaired oxidative phosphorylation which causes early activation of anaerobic glycolysis and excess lactate production with exercise. In order to evaluate the change in the skeletal muscle metabolism as a possible cause of the improvement in the exercise tolerance after the rehabilitation, noninvasive $^{31}P$ magnetic resonance spectroscopy(MRS) of the forearm flexor muscle was performed before and after the exercise training in nine patients with chronic lung disease who have undertaken intensive pulmonary rehabilitation for 6 weeks. 31p MRS was studied during the sustained isometric contraction of the dominant forearm flexor muscles up to the exhaustion state and the recovery period. Maximal voluntary contraction(MVC) force of the muscle was measured before the isometric exercise, and then 30% of MVC force was constantly loaded to each patient during the isometric exercise. After the exercise training, exercise endurance of upper and lower extremities and 6 minute walking distance were significantly increased(p<0.05). There were no differences of baseline intracellular pH (pHi) and inorganic phosphate/phosphocreatine(Pi/PCr). After rehabilitation pHi at the exercise and the exhaustion state showed a significant increase($6.91{\pm}0.1$ to $6.99{\pm}0.1$ and $6.76{\pm}0.2$ to $6.84{\pm}0.2$ respectively, p<0.05). Pi/PCr at the exercise and the recovery rate of pHi and Pi/PCr did not show significant differences. These results suggest that the delayed intracellular acidosis of skeletal muscle may contribute to the improvement of exercise endurance after pulmonary rehabilitation.

  • PDF

Assessment of Abnormality in Skeletal Muscle Metabolism in Patients with Chronic Lung Desease by $^{31}P$ Magnetic Resonance Spectroscopy ($^{31}P$ 자기 공명분석법을 이용한 만성 폐질환 환자에서의 골격근대사 이상에 관한 연구)

  • Cho, Won-Kyoung;Kim, Dong-Soon;Lim, Tae-Hwan;Lim, Chae-Man;Lee, Sang-De;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.3
    • /
    • pp.583-591
    • /
    • 1997
  • The functional derangement of skeletal muscles which may be attributed to chronic hypoxia has been accepted as a possible mechanism of exercise impairment in patients with chronic obstructive pulmonary disease (COPD). The metabolic changes in skeletal muscle in patients with COPD are characterized by impaired oxidative phosphorylation, early activation of anaerobic glycolysis and excessive lactate and hydrogen ion production with exercise. But the cause of exercise limitation in patients with chronic lung disease without hypoxia has not been known. In order to evaluate the change in the skeletal muscle metabolism as a possible cause of the exercise limitation in chronic lung disease patients without hypoxia, we compared the muscular metabolic data of seven male patients which had been derived from noninvasive $^{31}P$ magnetic resonance spectroscopy(MRS) with those of five age-matched normal male control persons. $^{31}P$ MRS was studied during the sustained isometric contraction of the dominant forearm flexor muscles up to the exhaustion state and the recovery period. Maximal voluntary contraction(MVC) force of the muscle was measured before the isometric exercise, and the 30% of MVC force was constantly loaded to each patient during the isometric exercise. There were no differences of intracellular pH (pHi) and inorganic phosphate/phosphocreatine(Pi/PCr) at baseline, exhaustion state and recovery period between two groups. But pHi during the exercise was lower in patients group than the control group (p < 0.05). Pi/PCr during the exercise did not show significant difference between two groups. These results suggest that the exercise limitation in chronic lung disease patients without hypoxia also could be attributed to the abnormalities in the skeletal muscle metabolism.

  • PDF

Effects of 8 Weeks Resistance Training on Nitric Oxide (NO) Concentration and Mean Arterial Pressure (MAP) in Young Men (건강한 젊은 성인에서 8주 규칙적인 저항성 트레이닝이 산화질소(NO) 농도와 평균동맥압(MAP)에 미치는 영향)

  • Kim, Young-Il;Paik, Il-Young;Kwak, Yi-Sub;Kim, Keun-Soo;Woo, Jin-Hee
    • Journal of Life Science
    • /
    • v.19 no.5
    • /
    • pp.625-632
    • /
    • 2009
  • The purpose of this study was to examine the effect of exercise training on nitric oxide (NO) levels, mean arterial pressure (MAP), blood pressure (BP), and heart rate (HR) in college students. 5 subjects were randomly assigned to two experimental groups; an aerobic training group (ATG) and a resistance training group (RTG). In aerobic training, based on measured maximum oxygen consumption rate, 70% exercise intensity was applied and conducted for 60 min. In resistance training, 70% of 1-RM was performed for 90 min. Blood sampling was conducted 3 times during resting state, post-exercise, and after 30 minutes of recovery. The results are as followed. For the post training values of $VO_2max$, % body fat and MAP, there were significant differences in the ATG compared to pre training (p<0.05). However, there were no differences in the RTG between pre and post training. NO increased post training, during rest and at the end of exercise compared to pre training in the ATG (p<0.05). Also, the HR decreased in post training at the end of exercise (p<0.05), however, there were no significant differences in SBP and DBP between pre and post training in the ATG. The HR, SBP and DBP did not change at all in post training compared to pre training in the RTG. In conclusion, an increase in the production of Nitric Oxide (NO) concentration and $VO_2max$, decrease of body fat% and physiological variables (HR, BP, MAP) were shown to be more effective in aerobic training (AT) than resistance training (RT).

Vibration Modeling and Optimal Design of Differential Electromagnetic Transducer for Implantable Middle Ear Hearing Devices using the FEA (FEA를 이용한 이식형 인공중이용 차동전자 트랜스듀서의 진동 모델링과 최적 설계)

  • Kim Min-Kyu;Lim Hyung-Gyu;Han Chan-Ho;Song Byung-Seop;Park Il-Yong;Cho Jin-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.7
    • /
    • pp.379-386
    • /
    • 2005
  • Among various kinds of hearing aids which have been developed so far. the conventional air conduction hearing aids have some problems such as the acoustic distortion, an howling effect due to acoustic feedback. Another type of hearing aid. the cochlear implant system can be applied to the profound imparied person. However. it shows the disadvantage that there is no possibility of recovery of the acoustic organ such as ossicle. On the other hand. the implantable middle ear heaving device directly vibratos the ossicular chain and has better sound qualify. good cosmetics for appearance. and wide frequency responses so that it can overcome the defects or the conventional hearing aids. In this paper, a mathematical modeling and a momentum equation derivation of the DET has been performed. For the optimization of the structure dimension generating maximal vibrating force of the DET. the computer simulation using a finite element analysis (FEA) software has been performed. Also. the vibrating transducer has been designed to make the frequency characteristics or the transducer be similar to those of the normal middle ear. Through the experimental results, the measured vibration characteristics of the DET has been evaluated to verify the performance for the application to implantable middle ear hearing devices.

A Study on the Development of Analytical Methods and Behaviors of Environmental Pollutants(III) : On-Line System for Preconcentration and Separation of Trace Phenols by HPLC (환경 오염물질의 정량법 개발과 거동에 관한 연구(III) : 미량 페놀류의 HPLC 정량을 위한 온 라인 농축)

  • Lee, Dai Woon;Kim, Jin Young;Park, Young Hun;Moon, Myeong Hee
    • Analytical Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.33-39
    • /
    • 1994
  • The purpose on this study was to develop a new improved chromatographic method for determination of trace phenols from environmental waste water. The research was carried out with selected 8 phenols, and solid-phase extraction was employed as sample pretreatment method. The coupling of XAD-4 and Dowex $1{\times}8$ resin as preconcentration column increased the selectivities toward interferences coexisted in matrix. Automation was accomplished with on-line process of pretreatment and HPLC system. After elution of sample through XAD-4 column, phenols were adsorbed by dispersion force, then displaced from it by ACN basified, simultaneously and selectively readsorbed via anion exchange on Dowex $1{\times}8$. Dowex $1{\times}8$ column was washed by water. Phenols readsorbed were removed from Dowex $1{\times}8$ column by a minimum volumn of methanol containing HCl. Each pretreatment step was connected by switching valves and the eluate was directly on-line injected to obtain fast and reliable results into the HPLC. Recovery of phenols was greater than 90%. To examine utility of this method, analysis of phenols from laboratory waste water sample which was added some organic pollutants to find with phenols on environmental waste water were also accomplished without their interference effects.

  • PDF