• Title/Summary/Keyword: Reconstruction plate and Wire fixation

Search Result 5, Processing Time 0.02 seconds

Clinical and Radiologic Outcomes of Acute Acromioclavicular Joint Dislocation: Comparison of Kirschner's Wire Transfixation and Locking Hook Plate Fixation

  • Rhee, Yong Girl;Park, Jung Gwan;Cho, Nam Su;Song, Wook Jae
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.4
    • /
    • pp.159-165
    • /
    • 2014
  • Background: Kirschner's wire (K-wire) transfixation and locking hook plate fixation techniques are widely used in the treatment of acute acromioclavicular joint (ACJ) dislocation. The purpose of this study was to compare the clinical and radiologic outcomes between K-wires transfixation and a locking hook plate fixation technique. Methods: Seventy-seven patients with acute ACJ dislocation managed with K-wire (56 shoulders) and locking hook plate (21 shoulders) were enrolled for this study. The mean follow-up period was 61 months. Results: At the last follow-up, the shoulder rating scale of the University of California at Los Angeles (UCLA) was higher in patients treated with locking hook plate than with K-wires ($33.2{\pm}2.7$ vs. $31.3{\pm}3.4$, p=0.009). In radiologic assessments, coracoclavicular distance (CCD) (7.9 mm vs. 7.7 mm, p=0.269) and acromioclavicular distance (ACD) (3.0 mm vs. 1.9 mm, p=0.082) were not statistically different from contralateral unaffected shoulder in locking hook plate fixation group, but acromioclavicular interval (ACI) was significant difference. However, there were significant differences in ACI, CCD, and ACD in K-wire fixation group (p<0.001). Eleven complications (20%) occurred in K-wire transfixation group and 2 subacromial erosions on computed tomography scan occurred in locking hook plate fixation group. Conclusions: ACJ stabilization was achieved in acute ACJ dislocations treated with K-wires or locking hook plates. Locking hook plate can provide higher UCLA shoulder score than K-wire and maintain CCD, and ACD without ligament reconstruction. K-wire transfixation technique resulted in a higher complication rate than locking hook plate.

Treatment of Distal Clavicular Fracture by Reconstruction Plate and Wire Fixation (쇄골 원위부 골절에 대한 재건 금속판과 강선 고정술을 이용한 치료)

  • Suh, Mu-Sam;Kim, Sang-Hyo;Park, Hyeong-Taek
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.5 no.1
    • /
    • pp.58-62
    • /
    • 2006
  • Purpose: To evaluate the result of operative treatment with plate and wire fixation for fractures of the distal clavicle. Materials and Methods: We assessed 9 cases of fractures of the distal clavicle that were treated by plate and wire fixation from March 2001 to July 2003 and followed up over 1year. We used the reconstruction plate as a buttress and performed cerclage wiring to fix comminuted fracture site. The functional result of shoulder was evaluated by the scoring system of Rowe. Results: The average periods of bony union was 9 weeks in all cases. According to Rowe scoring system, the functional result was exellent in 7 cases and good in 2 cases. There was no LOM of shoulder and traumatic arthritis in AC joint. But there was skin irritation in 1 case. Conclusion : The operative method by reconstruction plate and wire fixation for distal clavicular fracture was useful when there were comminuted fracture. This method seems to be simple and satisfactory in terms of improvement of range of motion of shoulder, restoration of function and rare complication.

  • PDF

Surgical Management of Comminuted Midshaft Clavicle Fractures Using Reconstruction Plate and Circumferential Wiring: Does the Circumferential Wiring Interfere with the Bone Union? (쇄골 간부 복합 골절에서 재건 금속판 및 환 강선을 이용한 수술적 치료: 환 강선이 골 유합을 방해하는가?)

  • Kim, Kyung-Tae;Shin, Chung-Shik;Park, Young-Chul;Kim, Dong-hyun;Kim, Min-Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.245-252
    • /
    • 2021
  • Purpose: This study examined the radiological and clinical outcomes of internal fixation using a reconstruction plate and 21G circumferential wire in comminuted midshaft clavicular fractures. Materials and Methods: A retrospective cohort study was performed on 51 patients between 2005 and 2019. Thirty-two patients underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and 19 patients underwent surgery without a wire. The patients were assessed with the radiographic parameters, the University of California at Los Angeles (UCLA) score, and the visual analogue scale (VAS) pain score. Based on this, patients who operated without a circumferential wire were set as the control group, and the differences in bone union between the two groups were compared. Results: Thirty-two patients were followed-up for an average of 65 weeks, and 19 patients in the control group were followed-up for an average of 56 weeks. The radiological evaluation confirmed the anatomical reduction and bone union in all 32 patients. No case of nonunion was present. The UCLA score was 32.38 on average and 33.11 in the control group (p=0.395). The VAS score was 1.00 on average and 0.84 in the control group (p=0.668). A significant difference in the bony union time was observed between the group who underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and the control group (p=0.015). On the other hand, there was no statistical significance when other variables were controlled (p=0.107). Conclusion: For displaced midshaft clavicular fractures, internal fixation using a reconstruction plate and 21G circumferential wire maintained accurate anatomical reduction. The satisfactory clinical and radiological results mean that internal fixation using a reconstruction plate and 21G circumferential wire may be a good option for surgical treatment.

Versatility of n-butyl-2-Cyanoacrylate for the Reconstruction of Frontal Sinus Comminuted Fracture in Children (소아의 전두동에 발생한 복잡골절에서 Cyanoacrylate의 유용성)

  • Lee, Yong-Seok;Kang, Sang-Gue;Chun, Nam-Joo;Kim, Cheol-Hann;Tark, Min-Seong
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.96-101
    • /
    • 2011
  • Purpose: In treatment of facial bone fracture, occurred in children, we generally use wires, miniplate, absorbable plate or their combination. These foreign bodies can be palpable, and sometimes may cause infections, and need reoperation for removing. When bone fragments are multiple, small or thin, they are hard to handle and make accurate reduction of all fragments. In these cases, a biodegradable tissue adhesive, Histoacryl$^{(R)}$ (n-butyl-2-cyanoacrylate), can be used as fixation technique for small, multiple, and thin fracture fragments. Methods: 3 years old and 6 years old children, who has comminuted fracture on frontal sinus, we used Histoacryl$^{(R)}$ for fixation of multiple bone fragments. After approaching by coronal incision, we pulled out all bone fragments and reconstructed bone fragments by Histoacryl$^{(R)}$ and fixed those on frontal sinus by absorbable plates. Results: Photographs and 3-dimensional CT obtained preoperatively and postoperatively. And we compared them each other in terms of accuracy of reconstructed bony contour. We could reconstruct almost all bone fragments easily along 3-dimensional structure and get excellent aesthetic results. There was no complication such as infection. Conclusion: In treatment of comminuted facial bone fracture, occurred in children, Histoacryl$^{(R)}$ is an excellent method for accurate reconstruction in small and thin bone fragments which cannot be fixed by wire, miniplate or absorbable plate without complication.

Operative Treatment of Distal Clavicle Fracture with Acromioclavicular Joint Injury (견봉 쇄골 관절의 손상을 동반한 원위 쇄골 골절의 수술적 치료)

  • Kang, Ho-Jung;Koh, Il-Hyun;Joo, Jong-Hwan;Chun, Yong-Min;Kim, Hyung-Sik
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.59-66
    • /
    • 2011
  • Purpose: We wanted to evaluate the clinical and radiological outcomes and the prognosis of various surgical treatments for the distal clavicle fracture with an acromioclavicular joint injury. Materials and Methods: A retrospective study of 21 patients with a minimum of 12 months follow up was done. We classified acromioclavicular (AC) injury into type I (only intra-articular fracture (IAF), 5 cases), type II (IAF with widening of the AC joint > 7 mm, 9 cases) and type III (IAF with AC joint superior subluxation > 50%, 7 cases). The distal clavicle fractures were fixed using plate (9 cases), mini screws (1 case), K wire and tension band wiring (10 cases) and transarticular pinning (1 case). Acromioclavicular or coracoacromial ligament reconstruction was not done in all the cases. Results: In 20 of 21 cases, bone union was achieved at an average of 8.4 weeks. Traumatic arthritis (5 cases), AC joint widening (4 cases) and AC joint subluxation (2 cases) were noted at the last follow up. The average UCLA score was 32.6 in the type I AC joint injuries, 34 in type II and 34.1 in type III. There was no relationship between the clinical outcomes and the preoperative AC joint injury pattern, postoperative traumatic arthritis, AC joint widening or AC joint subluxation (p>0.05). Conclusion: Satisfactory results were achieved by acute reduction and firm fixation of the distal clavicle fracture with AC joint injury. There was no relationship between the pattern of AC joint injury, the residual radiologic findings and the functional outcome.