• Title/Summary/Keyword: Reconstruction of femur

Search Result 57, Processing Time 0.019 seconds

Treatment of Chronic Osteomyelitis of Femur and Reconstruction with Fibular Osteocutaneous Free Flap (대퇴골 만성골수염의 치료 및 비골 유리골피판술을 이용한 재건)

  • Baik, Eui Hwan;Ahn, Hee Chang;Choi, Seung Suk;Jo, Dong In;Hwang, Kun Sung;Chung, Ung Seu
    • Archives of Plastic Surgery
    • /
    • v.33 no.5
    • /
    • pp.637-642
    • /
    • 2006
  • Purpose: Incidence of chronic osteomyelitis in femur is lower than that of tibia due to abundantsurrounding soft tissue like muscles and subcutaneous fat. However, if the femur is infected, surgical approach would be very difficult because of surrounding soft tissue and bony defects would be getting larger due to the late detection. Chronic osteomyelitis of femur is an intractable disease with frequent recurrence and remained bone instability in spite of multiple classical operations. Methods: From August 1998 to October 2005, we had 7 cases of fibular osteocutaneous free flap to reconstruct the femur. Those were followed-up for 23 months. All 7 cases were male. 4 cases were in midshaft and the others are distal part of femur. Results: The 7 cases that had not been healed in spite of average 9.1 times previous operations were reconstructed successfully without the recurrence of chronic osteomyelitis. Continuous rehabilitation therapy and brace were very helpful for the ambulation. It took 5.6 months for complete union of bone, and 9.8 months for the ambulation. Conclusion: After wide resection, reconstruction of the femur using fibular osteocutaneous free flap guaranteed bone stability and prevented recurrence of osteomyelitis through rich blood supplying fibula and muscle. Double barrel graft of fibula would be needed in case of the sufficient strength and thickness of femur. We report the successful results of reconstruction of femur with fibular osteocutaneous free flap for chronic osteomyelitis of femur.

Reconstruction of Large Femur and Tibia Defect with Free Vascularized Fibula Graft and Locking Plate

  • Kim, Min Bom;Lee, Young Ho;Baek, Jeong Kook;Choi, Ho Sung;Baek, Goo Hyun
    • Archives of Reconstructive Microsurgery
    • /
    • v.24 no.2
    • /
    • pp.68-74
    • /
    • 2015
  • Purpose: The reconstruction of femur and tibia defects following tumor resection remains a surgical challenge. The clinical outcome of free vascularized fibula graft (VFG) reconstruction with locking plate for massive femur and tibia defects of more than 10 cm that were secondary to skeletal tumor resection is reported. Materials and Methods: Thirteen patients with a mean follow-up of 3.3 years were reviewed. Seven patients received vascularized fibula grafts in the femur and six in the tibia. The mean bony defect of the femur and tibia was more than 10 cm and the length of the grafted fibula was more than 15 cm. All defects were stabilized with long locking plates. Results: All patients were free of disease at final follow-up; All VFGs were transferred successfully. All patients had a successful outcome with bony union. Stress fractures of the grafted fibula had occurred but the locking plate stabilized the fracture and healed until the last follow-up. All patients were able to walk without a brace after a mean of 9 months postoperatively. Conclusion: VFG with locking plate is a reliable reconstructive procedure for massive femur and tibia defects.

Treatment of Deformity in Polyostotic Fibrous Dysplasia Using Interlocking Intramedullary Nailing (다발성 섬유성 골이형성증 변형에 대한 나사못 맞물림 골수정을 이용한 치료)

  • Lee, Kwang-Suk;Oh, Jong-Keon;Koo, Ja-Seong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.1 no.2
    • /
    • pp.249-253
    • /
    • 1995
  • The fibrous dysplasia is a progressive and disabling condition that lead to deformity, especially weight bearing bones. The morbidity that is associated with the polyostotic fibrous dysplasia is the recurrent fracture and deformity. Various methods of treatment had been failed to control this problem. We used osteotomy and reconstruction nailing for polyostotic fibrous dysplasia occured in the proximal part of right femur with varus deformity and reconstruction nailing in left femur without osteotomy, and interlocking intramedullary nailing in right tibia to prevent pathologic fracture. These methods brought a good result of bone union and full weight bearing ambulation after 1 year and 6 month follow up. We think these methods are useful methods to control refracture and deformity, so we reported this case with bibliographic reviews.

  • PDF

Reconstruction of Metaphyseal Defect of Large Long Tubular Bone with Double Barreled Fibular Graft (중첩한 비골 이식술을 이용한 대형 장골의 골 간단부 결손의 재건)

  • Chung, Duke-Whan;Park, Jun-Young
    • Archives of Reconstructive Microsurgery
    • /
    • v.14 no.1
    • /
    • pp.50-56
    • /
    • 2005
  • There are limited treatment options in the reconstruction of the very large defect in the metaphyseal portion of distal femur and proximal tibia. Fibula is one of the most popular donor of the long bone reconstruction in reconstructive microsurgical field. It has many advantages such as very strong strut tubular bone, very reliable vascular anatomy with large vascular diameter and long pedicle. There are limited donor site problems such as transient peroneal nerve dysfunction. In those situations with the huge long bone defects in distal femur or proximal tibia, the defective bony shape and strength of the transplanted fibular bone is not enough if only one strut of the fibula is transferred. We performed 7 cases of "doule barrel" fibular transplantation on the metaphyseal portion of distal femur and proximal tibial large defects in which it is very difficult to fill the bony gap with conventional bone graft or callotasis methods. It takes averaged 8.3 months since that procedure to obtain bony union. After solid union of the transferred double barrelled fibular graft. There were no stress fracture in our series. So we can propose double barrel fibular graft is useful method in those cases with very large bone defect on the metaphysis of large long bone.

  • PDF

Analysis of Isometry of the Anterior Cruciate Ligament for Optimal Ligament Reconstruction (전방십자인대의 최적 재건을 위한 등장성 해석)

  • Park Jung-Hong;Suh Jeung-Tak;Moon Byung-Young;Son Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.4 s.247
    • /
    • pp.457-464
    • /
    • 2006
  • The anterior cruciate ligament (ACL) is liable to a major injury that often results in a functional impairment requiring surgical reconstruction. The success of reconstruction depends on such factors as attachment positions, initial tension of ligament and surgical methods of fixation. The purpose of this study is to find isometric positions of the substitute during flexion/extension. The distance between selected attachments on the femur and tibia was computed from a set of measurements using a 6 degree-of-freedom magnetic sensor system. A three-dimensional knee model was constructed from CT images and was used to simulate length change during knee flexion/extension. This model was scaled for each subject. Twenty seven points on the tibia model and forty two points on the femur model were selected to calculate length change. This study determined the maximum and minimum distances to the tibial attachment during flexion/extension. The results showed that minimum length changes were $1.9{\sim}5.8mm$ (average $3.6{\pm}1.4mm$). The most isometric region was both the posterosuperior and anterior-diagonal areas from the over-the-top. The proposed method can be utilized and applied to an optimal reconstruction of ACL deficient knees.

A Study on the Voxel Mesh Technique for Finite Element Modeling of Human Bone (인체 골(bone)의 유한요소 모델링을 위한 VOXEL MESH 기법에 관한 연구)

  • 변창환;오택열;백승민;채경덕
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1081-1084
    • /
    • 2002
  • In this study, we perform 3-D reconstruction of human proximal femur from DICOM files by using voxel mesh algorithm. After 3-D reconstruction, the model converted to Finite Element model which developed for automatically making not only 3-D geometrical model but also FE model from medical image dataset. During this job, trabecular pattern, one of characteristic of human bone can be added to the model by means of giving it's own elastic property calculated from intensity in CT scanned image to the each voxel. And then another model is made from same image dataset which have two material properties - one corresponds to cortical bone, another to trabecular bone. Finally, validity of voxel mesh technique is verified through comparing results of FE analysis, free vibration and stress analysis.

  • PDF

A Study on 3d Reconstruction and Simulated Implantation of Human Femur Using Consecutive CT-Images (연속된 CT-Image를 이용한 고관절 3d 형상의 재구성 및 Simulated Implantation System 구축에 관한 연구)

  • 민경준;김중규;최재봉;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.155-164
    • /
    • 1999
  • In this paper, the prototype of SIS(Simulated Implantation System) for human femoral head is introduced. SIS is a software which carries on a virtual femoral head replacement surgery including 3d visualization as well as various numeric analyses between a patient's femur and artificial femur through certain stages of the image processing and of the computer graphics. Also, processes required after acquiring consecutive CT-images and projected image of an artificial femur are discussed, and the corresponding results including prototype of SIS are given.

  • PDF

Reconstruction of Extensor Mechanism After Prosthetic Replacement of The Proximal Tibia (근위 경골에 발생한 악성종양 절제 후 슬관절 신전력 재건술 -증례 보고-)

  • Park, Jong-Hoon;Oh, Jung-Moon;Kim, Jin-Wook;Lee, Soo-Yong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.10 no.2
    • /
    • pp.120-123
    • /
    • 2004
  • Benign and malignant bone tumors occur most commonly around the knee. The proximal tibia is the most technically demanding site for limb salvage surgery. The most difficult problem using an endoprothesis for proximal tibial resection has been reconstruction of the extensor mechanism. After excision of proximal tibia, we resected distal femur and made a composite with resected distal femur, low heat treated autogenous proximal tibia and endoprothesis. Patella was fixed into the resected down-loaded distal femur. This article shows the new technique and the results of reconstruction of extensor mechanism after prosthetic replacement of the proximal tibia.

  • PDF

Reconstruction with Extracorporeally Radiated Autogenous Bone Graft After Wide Resection of Bone Tumors (골종양 절제후 방사선 조사한 자가골을 이용한 재건술)

  • Lee, Jong-Seok;Jeon, Dae-Geun;Kim, Sug-Jun;Lee, Soo-Yong;Yang, Hyun-Seok
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.3 no.1
    • /
    • pp.32-38
    • /
    • 1997
  • PURPOSE : For the reconstruction of large bone defect after tumor resection, it is possible to reuse the bone involved by tumor with some treatment to it. Several bone-reusing methods have been reported such as autoclaving, low-heat treatment(pasteurization) and intraoperative radiotherapy. We have used extracorporeally radiated autogenous bone graft for reconstruction after tumor resection, and analyzed the periods for junctional union, functional results and complications to know the indications of this method. METHODS : From Dec. 1993 to Sept. 1995, nine patients had taken autogenous bone graft with extracorporeal irradiation. Eight cases were osteosarcoma and 1 giant cell tumor. The graft sites were 5 in femur, 3 proximal tibia and 1 femur and tibia. Stage 3 was 1 case(GCT), Stage IIB 3 and Stage IIIB 5. After wide resection, surrounding soft tissue and intramedullary and extramedullary portion of the tumor were removed. Radiation was done in 5000cGy to the resected bone. Ender nails and bone cement were inserted and filled into the medulla to prevent fracture. RESULTS : Average follow-up period was 12.3(4 to 21) months. Average junctional union period in simple X-ray was 6.5 months in 4 cases. Average functional score following Enneking's criteria was 19(12-27). Complications were as follows ; condylar fractures and femur neck fracture in 4 cases, subluxation of the knee joint 3 and infection 1. Although local recurrence was detected in 1 case, the site of recurrence was not in the radiated bone but surrounding soft tissue. At final follow-up, no recurrence was found in one case(GCT), CDF 2, AWD 2, DOD 3, and died of chemotherapy related sepsis 1. CONCLUSIONS : Extracorporeally radiated bone autograft is considered to be a method for reconstruction of the large bone defect made by tumor resection, especially in the reconstruction around the joint.

  • PDF

Effects of Sensorimotor Training Volume on Recovery of Knee Joint Stability in Patients following Anterior Cruciate Ligament Reconstruction

  • Shim, Jae-Kwang;Choi, Ho-Suk
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.1
    • /
    • pp.27-32
    • /
    • 2016
  • Purpose: The purpose of this study is to examine the effects of sensorimotor training on knee joint stability after anterior cruciate ligament reconstruction. Methods: The subjects were sixteen 16 adults who received anterior cruciate reconstruction by arthroscopy, and underwent sensorimotor training for which was to have them maintenanceain of a standing position with a step Balance ball on the affected side over 30 degrees knee flexion with 100% weight bearing for 15-20 seconds. Before the genuine experiment commenced, the Lysholm scale was had been used to assess functional disorders on the affected knee joint. KT-2000 Arthrometer measurement equipment was used to measure anterior displacement of tibia against to femur before and after the sensorimotor training. Results: There was significant relaxation on the affected side in tibia anterior displacement of the affected and sound sides on in supine position before the sensorimotor training. There was little significant difference in tibia anterior displacement of the affected knee joints on in the supine position before and after the sensorimotor training. The results also showed that there was a reduction in the difference of tibia anterior displacement of the affected knee joints on in the standing position. These results suggest that the effects of sensorimotor training on knee joint stability after anterior cruciate ligament reconstruction is to induce the change of tibia anterior displacement against femur and the variation of muscles activation. Conclusion: The sensorimotor training may contribute to the improvement of joint functional stability in people who are in post-operation state and with orthopedic musculoskelectal injuries.