• Title/Summary/Keyword: Recoil length

Search Result 15, Processing Time 0.022 seconds

반능동가변형 주퇴복좌기의 설계 및 제어

  • 김동환;최문철;이규섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.213-217
    • /
    • 1997
  • The semi-active recoil system provides automatic hydraulic pressure and recoil length by an exteral impulse compared with the conventional recoil system. We developed the proto type of recoil system and validated the performance through simulation and experiment. The main issue of the system is how to adjust pressure and length simultaneously. The system consists of external pressure control valve and flow control valve outside of cylinder. The pressure control valve control the cylinder pressure and recoil length. The controlled system enhances the control performance.

ADAMS Simulation on the Scale Model of the FOOB System (연식주퇴 시스템 축소 모델에 대한 ADAMS 해석)

  • Kim, Jong-Hyuk;Bae, Jae-Sung;Hwang, Jai-Hyuk
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.9-14
    • /
    • 2011
  • Due to the improvement of science technology, the future tank system will have the multi-function for more powerful firing. and the tank, mounted this multi-function, must be lighter to maintain the mobility. Therefore, new brecoil technology would be necessary to reduce the recoil force for lighter platform. The present study covers a FOOB(Fire-Out0-Of-Battery) system that can reduce the recoil force dramatically. The firing sequence of the FOOB system is radically different from that of a conventional system. The gun is latched in out-of-battery position prior to firing. As soon as firing is occurred, the gun is unlatched and accelerated. The forward momentum is imparted to the recoiling parts. This momentum is opposed by the ballistic force imparted by firing and the recoil force and recoil length will be reduced. In this study, the ADAMS simulation has been performed with the scale model of the FIB(Fire-In-Battery) system and the FOOB system. The ADAMS simulation results show that the FOOB system could reduce the operating time and recoil length and the recoil force.

A Development of Recoil & Counter Recoil Motion Measurement System Using LVDT

  • Park, Ju-Ho;Hong, Sung-Soo;Joon Lyou
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.2 no.3
    • /
    • pp.214-219
    • /
    • 2000
  • This paper presents a recoil and counter recoil motion measurement system using linear variable differential transformers (LVDT). The output of the LVDT is obtained from the differential voltage of the secondary transformers. Since a transducer core is attached to the motion body, the output is directly proportional to the movement length of the core. Displacement, velocity and acceleration are measured from the LVDT. With a comparison between the measurement result and the reference value obtained by the highly accurate Vernier calipers, it is proved that the measurement system with the LVDT is applicable to the test of the moving part of the mechanism with better accuracy.

  • PDF

A Dynamic Analysis on the Latch of Soft Recoil System (연식주퇴 시스템 포신고정 장치의 동적 해석)

  • Woo, Dae-Hyun;Lee, Young-Shin;Kim, Heung-Tae;Jun, Sang-Bae;Lee, Kyu-Sub;Kang, Kuk-Jeong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.359-365
    • /
    • 2012
  • In the soft recoil system, the recoiling parts are initially accelerated to the forward direction. These parts are returned to original position by the firing with intial acceleration speed. The latch of the soft recoil system keeps the high impact load when the recoil parts were recuperated to the forward direction. In this study, the latch of soft recoil system using the ADAMS program was analyzed. The optimal operation parameters were found that max. angle and expansion length of latch was $50^{\circ}$, 180 mm respectively. Dynamic structural analyses of model cases were performed using finite element model. The max. stress and deflection of latch was 230 MPa and 0.45 mm respectively.

An Alternating Motion Technique Using Linear Variable Differential Transformers (선형변이 차동변압기를 이용한 왕복운동 계측기법)

  • 최주호;김윤겸
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.1073-1077
    • /
    • 1996
  • This paper presents a recoil and counter recoil(R&CR) motion measurement method using linear variable differential transformers(LVDT). The output of a LVDT is obtained from the differential voltage of the 2nd transformers. As a sensor core is attached at the motion body, the output is directly proportional to the core motion. Displacement, velocity and acceleration are measure from the core length. With a comparison between the measurement result and the known value which is obtained by the precision steel tape, the accuracy and the usefulness of the proposed scheme is validated.

  • PDF

A Study on Optimal Shape of Stent by Finite Element Analysis (유한요소 해석을 이용한 스텐트 최적형상 설계)

  • Lee, Tae-Hyun;Yang, Chulho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.1-6
    • /
    • 2017
  • Stents are widely used as the most common method of treating coronary artery disease with implants in the form of a metal mesh. The blood flow is normalized by inserting a stent into the narrowed or clogged areas of the human body. In this study, the mechanical characteristics of a stent are investigated according to the variations of its design parameters by the Taguchi method and finite element analysis. A stent model of the Palmaz-Schatz type was used for the analysis. In the analysis, an elasto-plastic material model was adopted for the stent and a hyper-elastic model was used for the balloon. The main interest of this study is to investigate the effects of the design parameters which reduce the possibility of restenosis by adjusting the recoil amount. A Taguchi orthogonal array was constructed on the model of the stent. The thickness and length and angle of the slot were selected as the design parameters. The amounts of radial recoil and longitudinal recoil were calculated by finite element analysis. The statistical analysis using the Taguchi method showed that optimizing the shape of the stent could reduce the possibility of restenosis. The optimized shape showed improvements of recoil in the radial and longitudinal directions of ~1% and ~0.1%, respectively, compared to the default model.

An alternating motion technique using linear variable differential transformers (선형변이 차동변압기를 이용한 왕복운동 계측기법)

  • Choi, Ju-Ho;Kim, Yoon-Gyeom;Yoo, Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1380-1383
    • /
    • 1996
  • This paper presents a recoil and counter recoil(R&CR) motion measurement method using linear variable differential transformers(LVDT). The output of a LVDT is obtained from the differential voltage of the 2nd transformers. As a sensor core is attached at the motion body, the output is directly proportional to the core motion. Displacement, velocity and acceleration are measure from the core length. With a comparison between the measurement result and the known value which is obtained by the precision steel tape, the accuracy and the usefulness of the proposed scheme is validated.

  • PDF

An Aalternating Motion Measurement Technique Using Linear Variables Differential Transformers (선형변이 차동변압기를 이용한 왕복운동 계측기법)

  • Choi, Ju-Ho;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.5
    • /
    • pp.455-460
    • /
    • 1997
  • This paper presents a recoil and counter recoil motion measurement method using linear variable differential transformers(LVDT). The output of a LVDT is obtained from the differential voltage of the 2nd transformers. As the sensor core is attached to the motion body, the output is directly proportional to the core motion. Displacement, velocity and acceleration are measured from the core length. A comparison between the measurement result and the known value, which is obtained by the precision steel tape, shows that the accuracy and the usefulness of the proposed scheme is validated.

  • PDF

Quantitative analysis of hydrogen in thin film by scattering-recoil co-measurement technique (산란-되튐 동시 측정 방법에 의한 박막 중 수소 정량법)

  • Lee, Hwa-Ryun;Eum, Chul Hun;Choi, Han-Woo;Kim, Joonkon
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.400-406
    • /
    • 2006
  • Hydrogen analysis by elastic recoil detection has been performed utilizing polyimide film as a reference sample of known hydrogen content assuming the soundness of ion beam current integration. However beam current integration at higher incidence angle is not reliable. Scattering yield per unit fluence by current integration which is normalized per unit path length decreases as the sample tilt angle is getting higher. Moreover because beam current integration at high tilt angle is incomplete, hydrogen evaluation is very risky by direct comparison of sequentially collected recoil spectra between reference and target sample. In this study, primary ion beam dose is determined by backscattering spectrum that is collected simultaneously with recoil spectrum instead of ion beam current integration in order to reduce uncertainty arising in the process of current integration and to enhance the reliability of quantitative analysis. Three test samples are selected $-7.6{\mu}m$ polyimide film, hydrogen implanted silicondioxide and Au deposited carbon wafer- and analyzed by two methods and compared.

Critical Heat Flux Enhancement Mechanism on a Surface with Nano-Structures (나노 구조가 형성된 열전달 표면에서의 임계 열유속 증진 메커니즘)

  • Kim, Dong Eok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.7
    • /
    • pp.619-624
    • /
    • 2014
  • The critical heat flux (CHF) on a heat transfer surface with nanostructures is known to be significantly better than that on flat surfaces. Several physical mechanisms have been proposed to explain this phenomenon. However, almost all studies conducted so far have been qualitative, and a generalized theory has not yet been established. In this study, we developed a quantitative mechanism for CHF enhancement on a surface with nanostructures, based on vapor recoil and surface adhesion forces. We focused on the increase in the length of the triple contact line owing to the formation of nanostructures and the adhesion force between them and the liquid.