• 제목/요약/키워드: Recognition voltage

검색결과 71건 처리시간 0.026초

Long-term and Real-time Monitoring System of the East/Japan Sea

  • Kim, Kuh;Kim, Yun-Bae;Park, Jong-Jin;Nam, Sung-Hyun;Park, Kyung-Ae;Chang, Kyung-Il
    • Ocean Science Journal
    • /
    • 제40권1호
    • /
    • pp.25-44
    • /
    • 2005
  • Long-term, continuous, and real-time ocean monitoring has been undertaken in order to evaluate various oceanographic phenomena and processes in the East/Japan Sea. Recent technical advances combined with our concerted efforts have allowed us to establish a real-time monitoring system and to accumulate considerable knowledge on what has been taking place in water properties, current systems, and circulation in the East Sea. We have obtained information on volume transport across the Korea Strait through cable voltage measurements and continuous temperature and salinity profile data from ARGO floats placed throughout entire East Sea since 1997. These ARGO float data have been utilized to estimate deep current, inertial kinetic energy, and changes in water mass, especially in the northern East Sea. We have also developed the East Sea Real-time Ocean Buoy (ESROB) in coastal regions and made continual improvements till it has evolved into the most up-to-date and effective monitoring system as a result of remarkable technical progress in data communication systems. Atmospheric and oceanic measurements by ESROB have contributed to the recognition of coastal wind variability, current fluctuations, and internal waves near and off the eastern coast of Korea. Long-tenn current meter moorings have been in operation since 1996 between Ulleungdo and Dokdo to monitor the interbasin deep water exchanges between the Japanese and Ulleung Basins. In addition, remotely sensed satellite data could facilitate the investigation of atmospheric and oceanic surface conditions such as sea surface temperature (SST), sea surface height, near-surface winds, oceanic color, surface roughness, and so on. These satellite data revealed surface frontal structures with a fairly good spatial resolution, seasonal cycle of SST, atmospheric wind forcing, geostrophic current anomalies, and biogeochemical processes associated with physical forcing and processes. Since the East Sea has been recognized as a natural laboratory for global oceanic changes and a clue to abrupt climate change, we aim at constructing a 4-D continuous real-time monitoring system, over a decade at least, using the most advanced techniques to understand a variety of oceanic processes in the East Sea.

지문인식센서 품질평가를 위한 검사부 프로브의 소재 적합성과 구조 최적화 연구 (Materials Compatibility and Structure Optimization of Test Department Probe for Quality Test of Fingerprint Sensor)

  • 손은원;윤지원;김대업;임재원;김광석
    • 마이크로전자및패키징학회지
    • /
    • 제24권4호
    • /
    • pp.73-77
    • /
    • 2017
  • 최근 정보 보호가 이슈화됨에 따라 지문인식센서의 활용이 점차 증가하고 있으며, 센서 인식률 오차를 최소화 할 수 있는 품질평가를 요구한다. 지문인식센서 전극과 검사부 프로브 팁이 접촉 시 발생하는 저항 값의 변화에 의해 센서의 품질이 평가되며, 품질평가의 재현성을 확보하기 위해서는 센서 전극의 변형 유발을 최소화할 수 있는 프로브 소재의 적합성과 구조 최적화 연구가 필요하다. 프로브 팁의 적합성 평가를 위한 소재로 니켈(Ni), 스틸(SK4), 베릴륨동(Beryllium copper), 인청동(Phosphor bronze)을 비교하였으며, 프로브 팁 접촉 후 전극의 압흔 크기와 접촉저항을 고려할 때 베릴륨동이 프로브 소재로 적합하다. 검사부 프로브는 지문인식센서 전극의 물리적 손상 방지와 다수의 지문인식센서 동시 검사가 가능한 구조를 위해 일체형 프로브 방식으로 제작하였다. 검사부의 재현성은 특정 전류 값을 인가하여 지문인식센서의 전압 변화로 판단하였으며, 베릴륨동 프로브 소재와 일체형 구조를 통해 센서 전극에 프로브가 300회 접촉하는 동안 센서의 전압 변화는 ${\pm}0.003V$ 이내의 우수한 재현성을 확인하였다.

자석검지기를 이용한 차종인식 알고리즘개발 (Development of Vehicle Classification Algorithm Using Magnetometer Detector)

  • 김수희;오영태;조형기;이철기
    • 대한교통학회지
    • /
    • 제17권4호
    • /
    • pp.111-124
    • /
    • 1999
  • 본 논문의 목적은 최근에 개발 중에 있는 단일 자석검지기를 이용한 차종인식 알고리즘을 개발하고, 현장실험을 통한 현장 적용성을 검토하는 것이다. 고속도로에 설치되어 이는 자석검지기를 이용하여 자료를 수집하며 분석에 이용되는 자료는 개별차량에 대하여 자속밀도의 변화에 따른 전압 값을 Digital Data값으로 변환한 수치를 사용하였다. 그 수치를 토대로 각 차량의 점유시간을 파악하여 각 차량의 점유시간동안 파형의 특징을 추출하여 각 특징들을 기초로 하여 각 차량이 나타내는 고유의 파형을 식별하는 Template Matching 방법과 신경망기법, 그리고 이들을 상호 보완한 복합기법을 사용하였다. 검지차량에 따른 다양한 점유시간을 일정크기로 수평성분 정규화하고 이에 따른 자속속밀도의 변화에 의한 전압 값을 차종별로 샘플을 취하여 이동평균방법으로 처리를 한 후 위의 세 가지 기법을 사용하여 검지차량의 파형과 기준 파형을 비교하여 차종을 인식하는 방법으로 알고리즘을 개발하였다. 차종의 분류는 3가지 단계로 하였는데 2종분류, 3종분류, 5종분류로 접근하였다. 그리고 각각의 분류에 따라 정규화 크기 및 이동평균간격을 달리하여 적용하여 보았고 2종분류에서 인식율이 82%수준이다.

  • PDF

An Automatic Corona-discharge Detection System for Railways Based on Solar-blind Ultraviolet Detection

  • Li, Jiaqi;Zhou, Yue;Yi, Xiangyu;Zhang, Mingchao;Chen, Xue;Cui, Muhan;Yan, Feng
    • Current Optics and Photonics
    • /
    • 제1권3호
    • /
    • pp.196-202
    • /
    • 2017
  • Corona discharge is always a sign of failure processes of high-voltage electrical apparatus, including those utilized in electric railway systems. Solar-blind ultraviolet (UV) cameras are effective tools for corona inspection. In this work, we present an automatic railway corona-discharge detection system based on solar-blind ultraviolet detection. The UV camera, mounted on top of a train, inspects the electrical apparatus, including transmission lines and insulators, along the railway during fast cruising of the train. An algorithm based on the Hough transform is proposed for distinguishing the emitting objects (corona discharge) from the noise. The detection system can report the suspected corona discharge in real time during fast cruises. An experiment was carried out during a routine inspection of railway apparatus in Xinjiang Province, China. Several corona-discharge points were found along the railway. The false-alarm rate was controlled to less than one time per hour during this inspection.

손끝 움직임 인식과 질감 표현이 가능한 촉각정보 입출력장치 (Tactile Transceiver for Fingertip Motion Recognition and Texture Generation)

  • 윤세찬;조영호
    • 대한기계학회논문집B
    • /
    • 제37권6호
    • /
    • pp.545-550
    • /
    • 2013
  • 본 논문은 정전기력을 이용한 마찰력 변조를 이용하여 손끝을 통한 촉각정보의 입출력을 동시 구현하는 소자를 제안하였다. 기존의 촉각소자들이 촉각정보의 입력 및 출력을 개별적으로 구현한 것에 비해 본 연구는 손끝의 수직/수평 방향 동작 인식과 질감 구현을 동시에 구현하였다는 점에서 차별성을 가진다. 실험분석을 통해 검증한 손끝 동작 인식기능은 수직방향의 클릭의 경우 0.146nF/$40{\mu}m$, 수평방향의 경우 0.09nF/$750{\mu}m$의 정전용량 변화를 통해 인식 가능하였으며, 질감 구현의 경우 정전기적 인력을 통해 마찰력을 32~152mN의 범위에서 제어할 수 있음을 확인하였다. 교류전압을 이용한 수평적 진동은 60V, 3Hz에서 최대 128.1mN의 마찰력 변조를 구현하였으며, 이는 기존 연구 대비 32% 향상을 보여준다. 본 연구는 손끝에서 정보의 입출력을 동시 구현하여 정보기기의 촉각인터페이스에 적용 가능하다.

HVDC DC CT 선형성 최적화 및 시스템 적용에 대한 연구 (Linearity Optimization of DC CT and a Study on the Application of HVDC System)

  • 최용길;이은재;최호석;이욱화
    • 전기학회논문지
    • /
    • 제63권6호
    • /
    • pp.758-763
    • /
    • 2014
  • These days, the advantages of DC power system are consistently stand out in korea that was a small power loss and high stability. Needs of DC power transmission technology is focused In the midst of a smart grid and environment friendly generation technology boom that is needed for next generation technology. Researches and businesses for HVDC(High Voltage Direct Current) system has been began. But, Needs of HVDC equipment and system commissioning technology are not on the rise until now. In particular, South Korea's HVDC technology is after the foot runner of advanced country and company. In addition, There is no experience for equipment verification and commissioning technology. And Experts of HVDC are rare. Who has been fully understood hardware and system as a whole, and identified all the equipment's characteristic. Recently, Academia and industry are recognized a needs of HVDC technology. But it does not received a recognition of technical value. In this paper, introduce issues when we apply the IEEE's verification method for HVDC system, especially DC current measurement system, DC CT(Direct Current Transformer), among the HVDC equipments. And Proposes remedial methods on the issue in order to recognize the necessity that was HVDC equipments's verification and commissioning technology research should be focused on.

Enantioselective electrophoretic behavior of lipoic acid in single and dual cyclodextrin systems

  • Le, Thi-Anh-Tuyet;Nguyen, Bao-Tan;Phan, Thanh Dung;Kang, Jong-Seong;Kim, Kyeong Ho
    • 분석과학
    • /
    • 제34권4호
    • /
    • pp.143-152
    • /
    • 2021
  • Capillary electrophoresis (CE) is an effective technique to study chiral recognition because it offers flexibility in adjusting vital factors. Currently, various available cyclodextrins (CDs) can be employed for the chiral separation of numerous analytes. Herein, we investigate the enantioseparation behavior of lipoic acid enantiomers in various types of single and dual CD systems through CE. Additionally, several impacted CE parameters were optimized through the systematic investigation based on the design of experiment (DoE) concept for a single system comprising a heptakis (2,3,6-tri-O-methyl)-β-CD and a dual system containing the combination of the single CD with a sulfated-β-CD. Consequently, absolute enantioresolution was obtained within 15 min on a common standard bare fused-silica capillary (64.5/56 cm in total/effective length, 50/365 ㎛ inner/outer diameter), maintained at 15 ℃ and at an applied voltage of 24 kV. The optimal background electrolyte consisted of 6 mM heptakis (2,3,6-tri-O-methyl)-β-CD dissolved in the solution of 58 mM borate buffer at pH 10. Furthermore, the results of apparent binding constant experiments indicated that the S-enantiomer-heptakis (2,3,6-tri-O-methyl)-β-CD complex exhibited a stronger affinity than its R-enantiomer counterpart. The obtained electrophoretic mobility values could be utilized to interpret the resolution achieved at various CD concentrations and the mobility behavior of the complexes elucidated the migration order of the enantiomers in an electropherogram.

초등학교 학생들의 생활 속 과학단위 인식과 이해 (Elementary Schooler's Recognition and Understanding of the Scientific Units in Daily Life)

  • 김성규
    • 과학교육연구지
    • /
    • 제36권2호
    • /
    • pp.235-250
    • /
    • 2012
  • 이 연구는 초등학교의 과학교과서, 과학관련 교과 및 실생활 관련 교과에 나오는 과학 단위를 분석하고, 초등학교 6학년 학생들의 생활 속에서 사용하고 있는 과학단위들의 인식과 이해정도를 알아보고자 하였다. 연구 대상은 320명의 초등학교 6학년 학생이며 설문의 내용은 생활 속에서 흔히 볼 수 있는 질량(kg), 거리(km), 부피(L), 전압(V), 시간(s), 온도($^{\circ}C$), 속력(km/h), 열량(kcal), 퍼센트(%), 전력(W), 산도(pH) 등 11개의 과학단위에 대한 이해와 인식정도를 알아보고 생활 속에서 과학단위를 찾고 배울 수 있는 장소에 관해 알아보고자 하였다. 통계처리 프로그램인 SPSS 17.0을 사용하여 응답별 빈도와 백분율을 산출하였다. 결과는 다음과 같이 요약 할 수 있다. 타 교과와의 단위비교에서는 대체적으로 학년에 따라 비슷하게 단위가 중복되었으며 학년이 올라갈수록 단위의 수준이 높아지고 또한 과목의 특성에 맞는 단위도 확인하였다. 단위의 용도를 묻는 질문에서는 kg, km, L, $^{\circ}C$, kcal, km/h, W 단위 등은 91% 이상으로 잘 알고 있었다. 전압(V)과 시간(s)은 다른 단위보다 정답률이 낮았다. 특히 전문성이 있는 %, pH단위는 잘 이해하지 못하였다. 그리고 단위의 인식을 묻는 질문에서는 예외로 액체의 부피(L)와 산-염기에 쓰이는 단위인 산도(pH) 단위를 제외하고는 대부분단위들은 90%이상으로 잘 이해하고 있었다. 생활 속 과학단위 찾기 활동으로 가장 적합한 장소 및 가장 많이 습득한 곳은 학교>상점/마트>신문/방송>거리/도로>가정> 기타 순서로 동일하게 나왔다. 이러한 결과는 학교에서 단위학습이 체계적으로 이루어져야 하고 또한 교사의 역할이 중요함을 알 수 있다. 따라서 위의 연구결과를 볼 때 생활 속 과학단위는 쉽게 장소에 따라 각각 과학단위 찾기가 가능하며 어디서나 과학단위 학습에 큰 효과가 있는 것으로 조사되었다. 그러므로 학생들이 과학단위를 보다 정확하게 이해하기 위해서는 교사가 적극적으로 과학단위를 정확하게 가르칠 필요가 있다. 그리고 초등학생이 알아야하는 과학단위이거나 어렵다고 생각되는 과학단위는 부록이나 NIE 활용 등을 통해서 과학교과서에 제시하거나 교사의 설명을 덧붙인다면 초등학생들의 과학단위를 보다 정확하고 바르게 이해하고 실생활에 활용과 수업에 큰 도움이되리라 생각된다.

  • PDF

VLBI 자료처리 시스템의 데이터 전송에서 잡음방지에 관한 연구 (A Study on the Noise Reduction Method for Data Transmission of VLBI Data Processing System)

  • 손도선;오세진;염재환;노덕규;정진승;오충식
    • 융합신호처리학회논문지
    • /
    • 제12권4호
    • /
    • pp.333-340
    • /
    • 2011
  • 한국천문연구원은 한일상관센터 (Korea-Japan Correlation Center, KJCC)에 2009년부터 한일공동VLBI상관기(Korea-Japan Joint VLBI Correlator, KJJVC)를 설치하여 운영하고 있다. 한일공동VLBI상관기는 한국우주전파관측망(Korean VLBI Network, KVN), VERA(VLBI Exploration of Radio Astrometry), JVN(Japanese VLBI Network) 및 공동 관측망 등에서 관측한 VLBI(Very Long Baseline Interferometer) 데이터를 상관처리하고, 과학적 목적을 위해 관측데이터를 처리하는 전용 계산기로 사용된다. KJJVC는 각 구성시스템 사이의 데이터 입출력 규격으로 VLBI 국제표준인 VSI(VLBI Standard Interface)를 따르고 있다. 특히 관측된 데이터를 상관처리하기 위해 고속재생기인 Mark5B시스템과 동기재생처리장치(Raw VLBI Data Buffer, RVDB) 사이에는 1024 Mbps급으로 데이터가 전송된다. 고속 데이터 전송에 있어 발생하는 전자기 방해 (Electromagnetic Interference, EMI)는 관측데이터의 손실을 야기 시키며, 전송 케이블의 길이가 길수록 손실 발생빈도가 많고, 디지털 데이터 신호의 전압레벨을 감소시켜 데이터 인식 오류를 초래한다. 따라서 본 논문에서는 VSI 규격의 통신에서 발생하는 EMI 잡음 정도를 측정하고, 데이터 손실을 최소화할 수 있는 방법으로 1) RC 필터를 사용한 방법, 2) Microstrip 라인을 이용한 임피던스 매칭, 3) Differential line driver를 이용한 신호 복원 방법 등을 제안하였다. 각 제안방법들의 유효성을 확인하기 위해 제안방법들은 시뮬레이션과 실험적인 구현을 통하여 성능시험을 수행하였으며, 각각의 제안 방법이 VSI 규격의 고속 데이터 전송에 유효함을 확인하였다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF