• Title/Summary/Keyword: Recognition voltage

Search Result 71, Processing Time 0.032 seconds

A study on the PD detecting of C-GIS using AE sensor (AE센서를 이용한 C-GIS의 부분방전 검출에 관한 연구)

  • Lee, H.Y.;Lee, Y.H.;Sin, Y.S.;Seo, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1659-1661
    • /
    • 2003
  • Recently, diagnostic techniques have been investigated to defect a partial discharge in high voltage electrical equipment. We have studied the characteristics of the acoustic partial discharge originating from the electrical defects in cubicle GIS(C-GIS). An acoustic emission(AE) sensor is used on the enclosure to detect partial discharge source because the sensor is sensitive to stress waves in its frequency range that may not be from a partial discharge source. AE signal is analyzed with phase-magnitude-frequency number(${\Phi}$-V-n) and pulse per second(PPS). Experience result has shown that the omitted acoustic signal has phase dependency and phase shift characteristic according to increase with applied voltage. These result will be helpful to the pattern recognition of the acoustic partial discharge in a C-GIS.

  • PDF

A Characteristics of UV images and PD quantity at Needle-Plane electrodes (침대평판 전극에서의 부분방전량과 자외선 이미지 특성)

  • Shong, Kil-Mok;Kim, Young-Seok;Park, Sang-Taek
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.101-104
    • /
    • 2009
  • In this paper, it's described the techniques for the analysis of corona generated in open live parts of electric facilities. At needle-plane electrodes, when the voltage increased($0{\sim}70kV$, ramping 10kV) using the high voltage generation system(HIPOTRINICS $0{\sim}200kV$, USA), it's generated the partial discharge. There are compared between UV detected image and PD quantity. As these results, UV areas and gains are normalized. And electric facilities are evaluated the 5 steps such as 'good', 'recognition', 'check', 'inspection', 'change(replacement)'.

  • PDF

Analysis on Partial Discharge Fault Signals of PRPD for High Voltage Motor Stator Winding (고압전동기 고정자 권선의 PRPD 부분방전 결함신호 해석)

  • Park Jae-Jun;Lee Sung-Young;Mun Dae-Chul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.10
    • /
    • pp.942-946
    • /
    • 2006
  • We simulated insulation defects of stator winding wire on high voltage generator by 5 types. 4 types have one discharge source and other one has multi discharge source by simulation. For accurate decision, measurements used to PRPD pattern to occurred partial discharge source of various types. In this research, when PRPD pattern carried out or analyzed pattern recognition of discharge source, it used to powerful tools. In this result, PRPD Pattern defined to have single discharge source of 4 types by insulation defect. When insulation defect simulated, all the defected winding have not the same result. Errors for a little different can make mistakes from a subtle distinction. The difference between internal and void discharge have magnitude of pulse amplitude of inner discharge bigger than void discharge and have a shape of bisymmetry. But void discharge has a shape of bisymmetry against maximum value on polarity respectively. In cases of slot and surface discharge, we confirmed to show similar results those other researchers. In case of multi-discharge, as a result of we could classify not perfect match with occurred patterns in single discharge eachother. In the future, we will have to recognize and classify with results of multi-discharge.

Identification of Arcing Fault and Development of An Adaptive Reclosing Technique about Arcing Ground Fault (아크지락사고에 대한 사고 판별 및 적응 재폐로 기법)

  • Kim, H.H.;Choo, S.H.;Chae, M.S.;Park, J.B.;Shin, J.R.
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.354-356
    • /
    • 2006
  • This paper presents a new one-terminal numerical algorithm for fault location estimation and for faults recognition. The proposed algorithm are derived for the case of most frequent single-phase line to ground fault in the time domain. The arc voltage wave shape is modeled numerically on the basis of a great number of arc voltage records obtained by transient recorder. From the calculated arc voltage amplitude it can make a decision whether the fault is permanent of transient. In this paper the algorithm uses a very short data window and enables fast fault detection and classification for real-time transmission line protection. To test the validity of the proposed algorithm the Electro-Magnetic Transient Program(EMTP/ATP) is used.

  • PDF

Characteristics of loci on Line-to-Earth Voltage according to Earth Fault in Earthing System for Ships (선박의 접지 시스템에서 지락 고장에 따른 대지 전압 변동 특성)

  • Kim, Jong-Phil;Ryu, Ki-Tak;Lee, Yun-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.487-495
    • /
    • 2021
  • The voltages mainly used in ships are 450 [V], 6.6 [kV], and 11 [kV], and an earthed system is applied to ensure the stability of the power distribution system. In general, low-voltage ships using 450 [V] apply an unearthed system, while high-voltage ships using 6.6 [kV] or 11 [kV] use a high-resistance earthed system. When an earth fault occurs in a ship's power distribution system, the voltage of the healthy phase increases to the line-to-line voltage or higher, which causes an excessive impact on the insulation of the cable. Thus, analyzing this behavior is very important. In this paper, we investigate the characteristics of the line-to-earth voltage variation according to earth faults and a recognition procedure of a faulty phase using the symmetrical coordinate method for a high-resistance earthed system and unearthed system. A mathematical model of the line-to-earth voltage was derived through the symmetric coordinate method, and the ship voltage for simulations was selected as 6.6 [kV] and 450 [V]. A MATLAB simulation proved that this method can determine the highest increase of the line-to-earth voltage, which leads by 120° on the faulty phase, and it accurately judges the faulty phase in both earthed systems.

Resolution Enhancement of an Ultrasonic Sensor System via Multiple Steps of the Transmitter Voltage (다단 송출전압을 이용한 초음파센서 시스템의 분해능 개선)

  • Na, Seung-You;Park, Min-Sang
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.298-306
    • /
    • 1997
  • Ultrasonic sensors are widely used in various applications due to advantages of low cost, simplicity in construction, mechanical robustness, and little environmental restriction in usage. But the main purposes of the noncontact sensors are rather narrowly confined within object detection and distance measurement. For the application of object recognition, ultrasonic sensors exhibit several shortcomings of poor directionality which results in low spatial resolution of an object, and specularity which gives frequent erroneous range readings. To resolve these problems in object recognition, an array of the sensors has been used. To improve the spatial resolution, more number of sensors are used in essence throughout the various devices of the sensor arrays. Under the disguise of a fixed number of the sensors, the array can be shifted mechanically in several steps. In this paper we propose a practical sensor resolution enhancement method using an electronic circuit accompanying the sensor array. The circuit changes the transmitter output voltage in several steps. Using the known sensor characteristics, a set of different return echo signals provide enhanced spatial resolution. The improvement is obtained without the cost of the increased number of the sensors nor extra mechanical devices.

  • PDF

Discrimination of insulation defects in a Gas Insulated Switchgear (GIS) by use of a neural network based on a Chaos Analysis of Partial Discharge(CAPD) (카오스이론을 이용한 GIS 내부 절연결함 판별)

  • Lim, Yun-Seok;Lee, Dong-Il;Koo, Ja-Yoon;Kim, Jeong-Tae;Bang, Hang-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2223-2225
    • /
    • 2005
  • In this work, experimental investigation has been mainly done. For this purpose, UHF sensor has been designed and fabricated to detect the partial discharges produced from the 10 artificial defects introduced into the real scale 70kV GIS mock-up under the high voltage at the well shielded room. And also, in order to verify the applicability of the proposed method at the site, the proposed CAPD (chaos analysis of partial discharge) is combined with spectral analysis method in order to identify the nature of the above 10 defects. The PD pattern recognition of each defect has been fulfilled by applying self developed artificial neural network soft ware. The result shows that the recognition rate is reached to be 80% by newly proposed method while the traditional PRPD analysis method leads us to obtain 41%. In consequence, it can be pointed out that the proposed method seems likely to be applicable to the real GIS at the site.

  • PDF

Optimization of Memristor Devices for Reservoir Computing (축적 컴퓨팅을 위한 멤리스터 소자의 최적화)

  • Kyeongwoo Park;HyeonJin Sim;HoBin Oh;Jonghwan Lee
    • Journal of the Semiconductor & Display Technology
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2024
  • Recently, artificial neural networks have been playing a crucial role and advancing across various fields. Artificial neural networks are typically categorized into feedforward neural networks and recurrent neural networks. However, feedforward neural networks are primarily used for processing static spatial patterns such as image recognition and object detection. They are not suitable for handling temporal signals. Recurrent neural networks, on the other hand, face the challenges of complex training procedures and requiring significant computational power. In this paper, we propose memristors suitable for an advanced form of recurrent neural networks called reservoir computing systems, utilizing a mask processor. Using the characteristic equations of Ti/TiOx/TaOy/Pt, Pt/TiOx/Pt, and Ag/ZnO-NW/Pt memristors, we generated current-voltage curves to verify their memristive behavior through the confirmation of hysteresis. Subsequently, we trained and inferred reservoir computing systems using these memristors with the NIST TI-46 database. Among these systems, the accuracy of the reservoir computing system based on Ti/TiOx/TaOy/Pt memristors reached 99%, confirming the Ti/TiOx/TaOy/Pt memristor structure's suitability for inferring speech recognition tasks.

  • PDF

An Embedded system for real time gas monitoring using an ART2 neural network

  • Cho, Jung-Hwan;Shim, Chang-Hyun;Lee, In-Soo;Lee, Duk-Dong;Jeon, Gi-Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.479-482
    • /
    • 2003
  • We propose a real time gas monitoring system for classifying various gases with different concentrations. Using thermal modulation of operating temperature of two sensors, we extract patterns of gases from the voltage across the load resistance. We adopt the relative resistance as a pre-processing method and an ART2 neural network as a pattern recognition method. The proposed method has been implemented in a real time embedded system with tin oxide gas sensors, TGS 2611, 2602 and an MSP430 ultra-low power microcontroller in the test chamber.

  • PDF

A study for pattern recognition of partial discharge in Extra High Voltage cable on the site (Neural Network를 이용한 초고압 실선로에서의 부분방전 패턴인식 연구)

  • Kim, Young-Hong;Kim, Choong-Sik;Kim, Jung-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.05a
    • /
    • pp.145-146
    • /
    • 2008
  • 초고압 케이블에서 발생하는 부분방전을 측정하기 위해 다양한 방법들이 연구 개발되어왔다. 최근에는 초고압 케이블의 설치 후 시행하는 준공시험에 있어 부분방전 측정을 필수적으로 할 만큼 부분방전 진단기술의 중요성이 부각되고 있는 실정이며, 디지털 측정기술을 통한 부분방전자동측정 기술이 많이 제안되고 있다. 특히, 비전문가들만으로도 진단 및 감시가 가능하도록 하는 자동 패턴 분류에 대한 다양한 연구에 활발히 보고되고 있다. 본 논문에서는 초고압 케이블에서 발생되는 결함을 내부, 외부, 노이즈의 세 가지로 분류하고 PRPD(Phase Resolved Partial Discharge) 형태로 모의된 실험데이터와 현장에서 축적된 데이터를 선별하여 다양한 통계치를 추출하였고, 결함별 구분이 용이하지 않은 통계치를 제외한 값들을 Neural Network 방법으로 학습시켰다. 학습된 가중치 값을 LabView로 작성된 프로그램에 사용하여 변전소 내 EBG에서 검출한 부분방전 측정 결과에 적용하였다.

  • PDF