Numerical Algorithm for Adaptive Autoreclosure and Fault Distance Calculation

  • ;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.79-81
    • /
    • 2003
  • This paper presents development and testing of a new numerical spectral domain algorithm devoted to blocking unsuccessful automatic reclosing onto permanent faults and the fault distance calculation. The arc voltage amplitude and the fault distance are calculated from the fundamental and third harmonics of the terminal voltages and currents phasors. From the calculated arc voltage amplitude it can be concluded if the fault is transient arcing fault or permanent arcless fault. If the fault is permanent automatic reclosure should be blocked. The algorithm can be applied for adaptive autoreclosure, distance protection, and fault location. The results of algorithm testing through computer simulation are given.

  • PDF

리클로징 시간을 고려한 배전계통 순간전압강하의 3상 유도전동기에 미치는 영향 검토 (Investigation of the impact of Voltage Sags on 3-Phase Induction Motors Considering Reclosing Interval in Distribution System)

  • 강봉석;김재철;문종필;윤상윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.45-47
    • /
    • 2004
  • This paper describes the various characteristics of voltage sags which can affect the functions of three-phase induction motors that are mostly used in the power distribution systems. These assorted characteristics include motor speed losses, voltage recovery, motor reacceleration, and transient characteristics. An experimental study on the induction motor behaviors was also carried out to confirm these impacts. In addition, sequential voltage sags with short durations were considered and investigated. The results show that the occurrence of the second voltage sag after the first one may affects the induction motor adversely.

  • PDF

실시간 시뮬레이터를 이용한 송전계통 자동재폐로 훈련 코스 개발 (A Development of Training Course for the Automatic Reclosing of Transmission Systems using a Real Time Digital Simulator)

  • 윤상윤;조윤성;이철균;김용길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.66-67
    • /
    • 2006
  • 본 논문은 실시간 디지털 시뮬레이터(Real Time Digital Simulator, RTDS)를 이용한 송전계통의 자동 재폐로 모의 교육훈련시스템 개발에 대해 요약하였다. 본 논문에서 개발한 모의 훈련 코스는 3상 일괄 재폐로와 1상 및 3상 재폐로의 두 가지 부분으로 나뉘어 구성되었다. RTDS를 이용한 모의 파일의 구성 시 각 계통은 양단에 거리계전기를 설치한 것으로 모의하였으며 154kV 계통의 경우 송전단은 실제 거리계전기를 이용하여 구성하였다. 1상 및 3상 재폐로의 경우 1선지락 고장에 대해서는 해당상만 트림 및 재폐로를 하도록 하고 나머지 고장에 대해서는 3상 일괄트립 및 재폐로가 되도록 모의하였으며 대상 계통은 345kV의 전형적인 송전계통을 대상으로 하였다. 리셋 시간의 모의 훈련을 위해 현재 국내 리셋시간 기준치 이내에 또 다른 고장이 발생했을 경우와 기준시간 이상 경과한 후에 고장이 발생한 경우를 나누어 모의할 수 있도록 구성하였다. 고장종류, 고장지속시간, 1상 및 3상 재폐로 선택, 재폐로 횟수 및 재폐로 시간 등은 현재 한국전력의 재폐로 규정에 언급된 것을 모의하는 것은 물론 사용자 임의로 변경이 가능하도록 구성하였다. 본 논문에서 개발한 모의 훈련코스는 송전계통의 자동재폐로에 대한 실무자들의 이해 증진을 위한 교육용으로 사용될 수 있음은 물론 보호 계전기 등의 시험을 위해서도 활용될 수 있을 것으로 기대한다.

  • PDF

아크지락사고에 대한 사고 판별 및 적응 재폐로 기법 (Identification of Arcing Fault and Development of An Adaptive Reclosing Technique about Arcing Ground Fault)

  • 김현홍;추성호;채명석;박종배;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.354-356
    • /
    • 2006
  • This paper presents a new one-terminal numerical algorithm for fault location estimation and for faults recognition. The proposed algorithm are derived for the case of most frequent single-phase line to ground fault in the time domain. The arc voltage wave shape is modeled numerically on the basis of a great number of arc voltage records obtained by transient recorder. From the calculated arc voltage amplitude it can make a decision whether the fault is permanent of transient. In this paper the algorithm uses a very short data window and enables fast fault detection and classification for real-time transmission line protection. To test the validity of the proposed algorithm the Electro-Magnetic Transient Program(EMTP/ATP) is used.

  • PDF

리클로져의 동작특성을 고려한 계통연계형 태양광발전시스템의 보호 알고리즘 (A Protection Algorithm of Grid-Interactive Photovoltaic System Considering Operation Characteristics of Recloser)

  • 김슬기;김응상
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권5호
    • /
    • pp.280-286
    • /
    • 2006
  • The paper proposes a new protection algorithm for reliable operation of grid-interfaced PV system, which can flexibly interact with conventional protective schemes of power utility grid not only to prevent damages to utility or public persons and utility apparatus caused by malfunction or failure in distribution network protection system, but also to protect a PV system itself from faults or abnormal conditions of the network. The proposed algorithm is based on reclosing characteristics of the distribution system. As a network fault occurs, the new scheme determines whether it is momentary or permanent and responds in a pre-programmed way to the fault. For permanent outage, the proposed algorithm shuts down inverter's operations but monitoring system voltage and frequency at the point of common coupling with grid. When it comes to the momentary outage, Inverter starts stand-by operation mode so that it can be automatically connected to the grid without start-up procedures as soon as the system voltage and frequency returns into the normal operation range. In order to investigate' and evaluate the PV system operation, simulation study based on PSCAD/EMTDC has been carried out to verify the performance of the proposed protection scheme.

연계형 태양광발전설비의 새로운 오동작 방지 및 재병입 알고리즘 제안 (Algorithm for Preventing Malfunction and Reclosing in Grid-Connected PV Systems)

  • 황민수;전태현
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.70-76
    • /
    • 2012
  • In general, the unidirectional power flow is normal in distribution feeders before activation of distributed power source such as PV. However, the interactive power flow is likely to occur in case of the power system under distributed generation. This interactive power flow can cause an unexpected effect on convectional protection coordination systems designed based only on the unidirectional power flow system. When the power line system encounters a problem, the interactive power flow can be a contributed current source and this makes the fault current bigger or smaller compared to the unidirectional case. The effect of interactive power flow is varied depending on the location of the point to ground fault, relative location of the PV, and connection method. Therefore it is important to analyse characteristics of fault current and interactive flow for various transformer connection and location of the PV. This paper proposes a method of improved protection coordination which can be adopted in the protective device for customers in distribution feeders interconnected with the PV. The proposed method is simulated and analysed using PSCAD/EMTDC under various conditions.

충전 동작이 용이한 간단한 구조의 DC 반도체 차단기 (A Simple-Structured DC Solid-State Circuit Breaker with Easy Charging Capability)

  • 김진영;김인동
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1575-1583
    • /
    • 2017
  • With the development of DC distribution, DC circuit breaker is required to ensure the stability of the DC grid. Unlike a mechanical circuit breaker that blocks after several tens of milliseconds, a DC SSCB(Solid-State Circuit Breaker) can break the fault well within 1 [ms], so it can prevent the damage of accident. However, the previous DC SSCB requires a lot of switching elements for charging commutation capacitors, and the control is complicated. Therefore, this paper proposes a new DC SSCB suitable for DC grid. The proposed DC SSCB is simple to control for charging commutation capacitors, and it can perform the rapid breaking and operating duty of reclosing and rebreaking. The proposed DC SSCB was designed to 380 [V] and 5 [kW] class which is suitable for residential DC distribution, and the operating characteristics of the proposed DC SSCB were verified by simulations and experiments. It is anticipated that the proposed DC SSCB may be utilized to design and realize DC grid system.

소형 열병합 발전기 계통연계 운전시의 적용 보호지침 개선 제안 (A case Study for Protection Relay System of small Cogeneration intertie)

  • 윤갑구;김경식;현대원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.227-230
    • /
    • 2004
  • The Co-Gen System which maximize energy efficiency was installed at the industrial plants at the initial stage. However Small Scale Co-Gen System was expanded even to the general end-users such as housing and building owing to ESCO business recently. For this SSC, inter-connected operation to the utility is desirable due to voltage and frequency fluctuation following to unbalance between power output and load. Then voltage unbalance with utility system, frequency, increase of short circuit capacity, reclosing, and ALTS etc. should be fully considered for the inter-connected operation. Voltage variation, protection coordination, Co-Generators single running, and short circuit capacity should also be solved. For Con-Gen users, the several protection relays are recommended to install at the user's main incoming panel by the guide lines and/or instructions of the interconnected utility Then user's main CB(Circuit Breaker) have the chance to be tripped by some of this recommended relays and users have to undergo the unexpected blackout. So the circuit breaker trip schemes targeted to trip with these protection relays are reconsidered and the study result is hereunder proposed.

  • PDF

민감한 전기전자기기의 전압외란에 대한 영향 최소화 연구 (A Research to Minimizing the Effect of Voltage Disturbances on Sensitive Electrical and Electronic Equipment)

  • 윤갑구
    • 기술사
    • /
    • 제19권2호
    • /
    • pp.10-20
    • /
    • 1986
  • 전압외란(voltage disturbances)에 대하여 민감함 전기전자기기가 받는 영향을 최소화하기 위한 방안으로 전력공급자측에서의 대책과 수용가기기에서의 대응책에 대하여 조사연구하였다. 전력공급자에서의 대책으로는 전압강하 시간의 단축에 대하여 검토하였는데, 효과와 경제성으로 보아 실현가능성이 적었다. 수용가기기에서의 대응책으로는 컴퓨터제어(computer control)와 자동화시스템(automated systems) 등에는 무정전 전원장치 또는 노이즈 서프레서(noise suppressor)나 파워콘디쇼너(power conditioners)를 설치하고, 전자개폐기는 지연석방형 전자개폐기를 채용하며, 가변속제어전동기에는 순간전압부하에 대한 대책이 고려된 제어회로를 채용하고, 고압방전등에는 순간재점등장치가 붙은 등기구를 채용하며, 부족전압계전기는 계전기의 정전시감을 연장하는 방안과 순간정전시에는 자동으로 재투입하는 sequence를 구성하는 방법등이 효과적인 대책으로 검토되었다.

  • PDF

기관 소속 저자들의 저작경향 분석 - H 의과대학 부속병원 소속저자들을 대상으로 - (A Study on Analyzing the Authorship Tendency of the Authors in the Specific Organizations: Focusing on the H Medical University G Hospital)

  • 이현정;김규환;장보성
    • 한국비블리아학회지
    • /
    • 제20권3호
    • /
    • pp.209-218
    • /
    • 2009
  • 본 연구는 특정 기관에 소속된 저자들의 저작경향을 분석하고자 하였다. 이를 위해 H 의과대학 부속병원 소속저자들을 대상으로 이들이 게재한 2000년부터 2008년까지의 SCI 논문을 추출하여 저자별로 색인화하였다. 소속 저자들의 저작경향을 일시성과 지속성 측면에서 분석하였다. 분석결과, 소속저자들은 일시적인 저작경향보다는 비교적 지속적인 저작경향을 보이는 것으로 나타났다. 구체적으로 신규저자들에 의한 출판비율은 평균 39.17%로 높지만 재투입 저자들의 출판비율(16.83%)과 연속저자의 출판비율(44%)로 구성된 기존저자들에 의한 출판비율이 평균 60.83%로 상대적으로 높게 나타났다. 또한 저자들의 일시성을 판단하는 신규소멸저자비율은 평균 28.2%로 비교적 낮았으며 특정연도의 저자들의 고정적 출판확률은 평균 76%로 매우 높게 나타났다. 본 연구에서 제시한 기관 소속저자들의 저작경향은 기관의 연구성과 관리를 위한 기초 데이터로 활용될 수 있을 것이다.