• Title/Summary/Keyword: Recirculation system

Search Result 419, Processing Time 0.027 seconds

Studies on decomposition behavior of oxalic acid waste by UVC photo-Fenton advanced oxidation process

  • Kim, Jin-Hee;Lee, Hyun-Kyu;Park, Yoon-Ji;Lee, Sae-Binna;Choi, Sang-June;Oh, Wonzin;Kim, Hak-Soo;Kim, Cho-Rong;Kim, Ki-Chul;Seo, Bum-Chul
    • Nuclear Engineering and Technology
    • /
    • v.51 no.8
    • /
    • pp.1957-1963
    • /
    • 2019
  • A UVC photo-Fenton advanced oxidation process (AOP) was studied to develop a process for the decomposition of oxalic acid waste generated in the chemical decontamination of nuclear power plants. The oxalate decomposition behavior was investigated by using a UVC photo-Fenton reactor system with a recirculation tank. The effects of the three operational variables-UVC irradiation, H2O2 and Fenton reagent-on the oxalate decomposition behavior were experimentally studied, and the behavior of the decomposition product, CO2, was observed. UVC irradiation of oxalate resulted in vigorous CO2 bubbling, and the irradiation dose was thought to be a rate-determining variable. Based on the above results, the oxalate decomposition kinetics were investigated from the viewpoint of radical formation, propagation, and termination reactions. The proposed UVC irradiation density model, expressed by the first-order reaction of oxalate with the same amount of H2O2 consumption, satisfactorily predicted the oxalate decomposition behavior, irrespective of the circulate rate in the reactor system within the experimental range.

A study on the electronic EGR valve control method (전자식 EGR밸브 제어기법에 관한 연구)

  • Choi, Sang-Yun;Lee, Sang-Hun;Lee, Seon-Bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2594-2602
    • /
    • 2014
  • As environmental awareness increases, regulations on exhaust gas of automobile, which is a cause of air pollution, have been strengthened. In order to meet emission regulation, automobile companies and engine manufacturers have actively developed the related technologies. Because the emission control has become severe, the systems using electronic motor or solenoid valve for high precise control are needed. For this reason, it is required not only the optimization of composition of components for improving performance and efficiency of the system but also the development of optimal design technology of electronic control system by securing the designing and manufacturing technology of the components. In this paper, it is proposed the position characteristics for electronic EGR valve module through the applied control logic and experiment results.

Effect of variation of water retention characteristics due to leachate circulation in municipal solid waste on landfill stability

  • M. Sina Mousavi;Yuan Feng;Jongwan Eun;Boo Hyun Nam
    • Geomechanics and Engineering
    • /
    • v.33 no.2
    • /
    • pp.141-154
    • /
    • 2023
  • This study investigated the effect of water retention characteristics between aged and fresh Municipal Solid Waste (MSW) on the stability of the landfill. A series of transient numerical modeling for the slope of an MSW landfill was performed considering the variation of water retention characteristics due to leachate circulation. Four different scenarios were considered in this analysis depending on how to obtain hydraulic conductivity and the aging degree of materials. Unsaturated hydraulic properties of the MSW used for the modeling were evaluated through modified hanging column tests. Different water retention properties and various landfill conditions, such as subgrade stiffness, leachate injection frequency, and gas and leachate collection system, were considered to investigate the pore water distribution and slope stability. The stability analyses related to the factor of safety showed that unsaturated properties under those varied conditions significantly impacted the slope stability, where the factor of safety decreased, ranging between 9.4 and 22%. The aged materials resulted in a higher factor of safety than fresh materials; however, after 1000 days, the factor of safety decreased by around 10.6% due to pore pressure buildup. The analysis results indicated that using fresh materials yielded higher factor of safety values. The landfill subgrade was found to have a significant impact on the factor of safety, which resulted in an average of 34% lower factor of safety in soft subgrades. The results also revealed that a failed leachate collection system (e.g., clogging) could result in landfill failure (factor of safety < 1) after around 298 days, while the leachate recirculation frequency has no critical impact on stability. In addition, the accumulation of gas pressure within the waste body resulted in factor of safety reductions as high as 24%. It is essential to consider factors related to the unsaturated hydraulic properties in designing a landfill to prevent landfill instability.

Development studies of microalgae-based closed recirculating bivalves adults conditioning system: I. Induction of the gametogenesis (이매패류 어미관리를 위한 미세조류 기반 폐쇄-순환여과시스템 개발 연구: I. 성 성숙 유도)

  • Kim, Chung Yoo;Hur, Young Baek;Han, Jong Chul;Park, Young chul
    • The Korean Journal of Malacology
    • /
    • v.32 no.3
    • /
    • pp.231-240
    • /
    • 2016
  • Techniques were developed for holding and conditioning of Pacific oysters, Crassostrea gigas, in a closed recirculating system. Experimental adults were used 500 oysters ( x two system, total 1,000 oysters) which were collected in $20^{th}$ March 2016 from long-line aquaculture farm at the south coast of Korea. During conditioning periods concentrated live microalgae as Isochrysis sp. $15{\times}10^7cells/mL$, Tetraselmis sp. $2{\times}10^7cells/mL$ and Pheaodactylum sp. $18{\times}10^7cells/mL$ were added 5 L every day, respectively which micro algae were functioned as diets and biological filter. Over all experimental periods total water exchange rate was 21.3% (daily 0.5%). Over 42 days conditioning, female and male oysters were maturated 90.9% and 94.4%, respectively. Survival rate was 98.7%. Mean shell hight (8.3 mm), total wet weight (19.2 g), meat wet weight (5.0 g) and shell wet weight (13.6 g) were significantly increased (P < 0.05). Water quality parameters including the water temperature ($22.1{\pm}0.4^{\circ}C$), salinity ($24.9{\pm}04$), dissolved oxygen (5.1-7.9 mg/L) and pH ($7.93{\pm}0.15$) were kept stable. Concentration of dissolved inorganic nutrient as ammonia (1.96-0.35 mg/L), nitrite (0.03-0.16 mg/L), nitrate (1.34-0.47 mg/L), DIP (0.42-0.03 mg/L) and silicate (3.83-0.00 mg/L) were significantly decreased throughout experiment except nitrite which was increased (P < 0.05), but nitrogenous components stayed below toxic levels (ammonia 0.0-5.5 mg/L, nitrite 0.0-460.0 mg/L) which indicated that closed recirculation system with microalgae based bio-filter could supply sufficiently environment condition to holding and conditioning of oyster.

A Case Study of Different Configurations for the Performance Analysis of Solid Oxide Fuel Cells with External Reformers (외부 개질형 평판형 고체 산화물 연료전지 시스템 구성법에 따른 효율특성)

  • Lee, Kang-Hun;Woo, Hyun-Tak;Lee, Sang-Min;Lee, Young-Duk;Kang, Sang-Gyu;Ahn, Kook-Young;Yu, Sang-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.3
    • /
    • pp.343-350
    • /
    • 2012
  • A planar solid oxide fuel cell (PSOFC) is studied in its application in a high-temperature stationary power plant. Even though PSOFCs with external reformers are designed for application from the distributed power source to the central power plant, such PSOFCs may sacrifice more system efficiency than internally reformed SOFCs. In this study, modeling of the PSOFC with an external reformer was developed to analyze the feasibility of thermal energy utilization for the external reformer. The PSOFC system model includes the stack, reformer, burner, heat exchanger, blower, pump, PID controller, 3-way valve, reactor, mixer, and steam separator. The model was developed under the Matlab/Simulink environment with Thermolib$^{(R)}$ modules. The model was used to study the system performance according to its configuration. Three configurations of the SOFC system were selected for the comparison of the system performance. The system configuration considered the cathode recirculation, thermal sources for the external reformer, heat-up of operating gases, and condensate anode off-gas for the enhancement of the fuel concentration. The simulation results show that the magnitude of the electric efficiency of the PSOFC system for Case 2 is 12.13% higher than that for Case 1 (reference case), and the thermal efficiency of the PSOFC system for Case 3 is 76.12%, which is the highest of all the cases investigated.

A Study on Effect of a Combined Plasma EGR System upon Soot CO and $CO_2$ Emissions in Turbo Intercooler Common-rail Diesel Engines (터보 인터쿨러 커먼레일 디젤기관의 매연, CO 및 $CO_2$ 배출물에 미치는 플라즈마 EGR 조합시스템의 영향에 관한 연구)

  • Bae, Myung-Whan;Ku, Young-Jin;Lee, Bong-Sub;Youn, Il-Joong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.4
    • /
    • pp.1-11
    • /
    • 2006
  • The aim in this study is to develop the combined EGR system with a non-thermal plasma reactor for reducing exhaust emissions and improving fuel economy in turbo intercooler ECU common-rail diesel engines. In this study, the characteristics of soot, CO and $CO_2$ emissions under four kinds of engine loads are experimentally investigated by using a four-cycle, four-cylinder, direct injection type, water-cooled turbo intercooler ECU common-rail diesel engine with a combined plasma exhaust gas recirculation(EGR) system operating at three kinds of engine speeds. The EGR and non-thermal plasma reactor system are used to reduce $NO_x$ emissions, and the non-thermal plasma reactor and turbo intercooler system are used to reduce soot and THC emissions. The plasma system is a flat-to-flat type reactor operated by a plasma power supply. The fuel is sprayed by pilot and main injections at the variable injection timing between BTDC $15^{\circ}$ and ATDC $1^{\circ}$ according to experimental conditions. It is found that soot emissions with increasing EGR rate are increased, but are decreased as the applied electrical voltage of the non-thermal plasma reactor is elevated at the same engine speed and load. Results also show that CO and $CO_2$ emissions are increased as EGR rate is elevated, and CO emissions are increased, but $CO_2$ emissions are decreased as the applied electrical voltage of the non-thermal plasma reactor is elevated at the same engine speed and load.

A Study on Characteristics of Performance and $NO_x{\cdot}THC$ Emissions in Turbo Intercooler ECU Common-rail Diesel Engines with a Combined Plasma EGR System (플라즈마 EGR 조합시스템 터보 인터쿨러 ECU 커먼레일 디젤기관의 성능 및 $NO_x{\cdot}THC$ 배출물 특성에 관한 연구)

  • Bae, Myung-Whan;Ku, Young-Jin;Lee, Bong-Sub
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.3
    • /
    • pp.10-21
    • /
    • 2006
  • The aim in this study is to develop the combined EGR system with a non-thermal plasma reactor for reducing exhaust emissions and improving fuel economy in turbo intercooler ECU common-rail diesel engines. At the first step, in this paper, the characteristics of performance and $NO_x{\cdot}THC$ emissions under four kinds of engine loads are experimentally investigated by using a four-cycle, four-cylinder, direct injection type, water-cooled turbo intercooler ECU common-rail diesel engine with a combined plasma exhaust gas recirculation(EGR) system operating at three kinds of engine speeds. The EGR system is used to reduce $NO_x$ emissions, and the non-thermal plasma reactor and turbo intercooler system are used to reduce THC emissions. The plasma system is a flat-to-flat type reactor operated by a plasma power supply. The fuel is sprayed by pilot and main injections at the variable injection timing between BTDC $15^{\circ}$ and ATDC $1^{\circ}$ according to experimental conditions. It is found that the specific fuel consumption rate with EGR is increased, but the fuel economy is better than that of mechanical injection type diesel engine as compared with the same output. Results show that $NO_x$ emissions are decreased, but THC emissions are increased, as the EGR rate is elevated. $NO_x$ and THC emissions are also slightly decreased as the applied electrical voltage of the non-thermal plasma reactor is elevated. Thus one can conclude that the influence of EGR in $NO_x$ and THC emissions is larger than that of the non-thermal plasma reactor, but THC emissions are greatly influenced by the non-thermal plasma reactor as the EGR rate is elevated.

A study on the optimal ventilation and smoke exhaust systems in case of fire in subway stations installed with PSD (PSD가 설치된 지하철 역사 내 화재 시 최적 배연시스템 연구)

  • Kim, Hyo-Gyu;Yoo, Ji-Oh;Kim, Doo-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.527-539
    • /
    • 2018
  • The subway used by many passengers is required to maintain a safe and comfortable environment and PSD (Platform Screen Door) must be installed in the platform after reinforcing the standard in 2003. In the previous research, in case of subway fire to control it, it is necessary to design the optimal ventilation and smoke exhaust system according to equipment capacity of the smoke exhaust system. Therefore, in this study, based on the results of previous research, three-dimensional numerical analysis was performed for the CO gas and smoke flow by the subway ventilation system in case of platform fire. As a result of this study, it was found that in case of emergency, if only the upper-level smoke exhaust system is activated, the risk of evacuation is high due to CO gas (653.8 ppm) and smoke concentration ($768.4mg/m^3$). And when all the smoke exhaust systems are activated and only the fire side PSD is opened, CO gas (36.0 ppm) and smoke concentration ($26.2mg/m^3$) are detected and the propagation range of smoke flow was reduced. When all the smoke exhaust systems are activated and only the fire side PSD is closed, it was analyzed as the most effective ventilation mode in the evacuation environment due to the absence of smoke-recirculation.

A Study on Effect of Recirculated Exhaust Gas upon Performance and Exhaust Emissions in a Power Plant Boiler with FGR System (FGR 시스템 동력 플랜트 보일러의 성능 및 배기 배출물에 미치는 재순환 배기의 영향에 관한 연구)

  • Bae, Myung-whan;Jung, Kwong-ho;Park, Sung-bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.4
    • /
    • pp.263-273
    • /
    • 2016
  • The effect of recirculated exhaust gas on performance and exhaust emissions with FGR rate are investigated by using a natural circulation, pressurized draft and water tube boiler with FGR system operating at several boiler loads and over fire air damper openings. The purpose of this study is to apply the FGR system to a power plant boiler for reducing $NO_x$ emissions. To activate the combustion, the OFA with 0 to 20% is supplied into the flame. When the suction damper of two stage combustion system installed in the upper side of wind box is opened by handling the lever between $0^{\circ}$ and $90^{\circ}$, also, the combustion air supplied to burner is changed. It is found that the fuel consumption rate per evaporation rate did not show an obvious tendency to increase or decrease with rising the FGR rate, and $NO_x$ emissions at the same OFA damper opening are decreased, as FGR rates are elevated and boiler loads are dropped. While a trace amount of soot is emitted without regard to the operation conditions of boiler load, OFA damper opening and FGR rate, because soot emissions are eliminated by the electrostatic precipitator with a collecting efficiency of 86.7%.

Analysis of Microbial Contamination in Poultry Slaughtering Operations for the Application of HACCP (HACCP 적용을 위한 도계처리 공정내 미생물 오염의 분석)

  • 홍종해;권혁무;고주언
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.1
    • /
    • pp.45-50
    • /
    • 1996
  • The application of HACCP system, which was adopted by Codex Alimentarius Committee for the safe meat and poultry production, is one of the urgent task for competing in the world trade markets. But there have been no useful analytical studies to identify the causes of contamination in the poultry meat processing plants in Korea. This study was conducted to investigate the potential hazards during the operations by the microbiological examination for the poultry meat processing plant (20,000 birds capacity a day) located in Kangwon province. In spite of air contamination of work places, it may not directly affect the surface contamination of poultry meats. But the risk of Campylobacter jejuni/coli contamination was high. The number of total count was decreased about ten times, but remarkable changes of microbial contamination could not be recognized in each procedure during the operations. The washing water was already contaminated as much as $10^{3-6}CFU/ml$ in SPC before the operations. It means that to keep water tanks hygienic is a primary step to prevent the occurrences of microbial contamination. The overflow and recirculation of water in scalding, washing, and chilling was aslo an important factor for a hygienic control. Based on this study, the followings could be regarded as an important factors for hygenic control in the poultry slaughtering plants on a small scale. The temperature of water used for scalding should be constantly maintained on a required temperature, and the overflow rate of 1~1.5 liter per bird. The carcass surface and the body cavity should be washed thoroughly and the cross-contamination due to facilities, workers, and tools should be prevented. The chilling water sholud be maintained under 5$\circ$C of temperature with ice and overflow, and residual chlorine level of 50 ppm.

  • PDF