• Title/Summary/Keyword: Receiving Sensitivity

Search Result 139, Processing Time 0.028 seconds

Effect of object position in the field of view and application of a metal artifact reduction algorithm on the detection of vertical root fractures on cone-beam computed tomography scans: An in vitro study

  • Nikbin, Ava;Kajan, Zahra Dalili;Taramsari, Mehran;Khosravifard, Negar
    • Imaging Science in Dentistry
    • /
    • v.48 no.4
    • /
    • pp.245-254
    • /
    • 2018
  • Purpose: To assess the effects of object position in the field of view (FOV) and application of a metal artifact reduction (MAR) algorithm on the diagnostic accuracy of cone-beam computed tomography (CBCT) for the detection of vertical root fractures(VRFs). Materials and Methods: Sixty human single-canal premolars received root canal treatment. VRFs were induced in 30 endodontically treated teeth. The teeth were then divided into 4 groups, with 2 groups receiving metal posts and the remaining 2 only having an empty post space. The roots from different groups were mounted in a phantom made of cow rib bone, and CBCT scans were obtained for the 4 different groups. Three observers evaluated the images independently. Results: The highest frequency of correct diagnoses of VRFs was obtained with the object positioned centrally in the FOV, using the MAR algorithm. Peripheral positioning of the object without the MAR algorithm yielded the highest sensitivity for the first observer (66.7%). For the second and third observers, a central position improved sensitivity, with or without the MAR algorithm. In the presence of metal posts, central positioning of the object in the FOV significantly increased the diagnostic sensitivity and accuracy compared to peripheral positioning. Conclusion: Diagnostic accuracy was higher with central positioning than with peripheral positioning, irrespective of whether the MAR algorithm was applied. However, the effect of the MAR algorithm was more significant with central positioning than with peripheral positioning of the object in the FOV. The clinical experience and expertise of the observers may serve as a confounder in this respect.

SOURCE-FREQUENCY PHASE-REFERENCING OBSERVATION OF AGNS WITH KAVA USING SIMULTANEOUS DUAL-FREQUENCY RECEIVING

  • Zhao, Guang-Yao;Jung, Taehyun;Sohn, Bong Won;Kino, Motoki;Honma, Mareki;Dodson, Richard;Rioja, Maria;Han, Seog-Tae;Shibata, Katsunori;Byun, Do-Young;Akiyama, Kazunori;Algaba, Juan-Carlos;An, Tao;Cheng, Xiaopeng;Cho, Ilje;Cui, Yuzhu;Hada, Kazuhiro;Hodgson, Jeffrey A.;Jiang, Wu;Lee, Jee Won;Lee, Jeong Ae;Niinuma, Kotaro;Park, Jong-Ho;Ro, Hyunwook;Sawada-Satoh, Satoko;Shen, Zhi-Qiang;Tazaki, Fumie;Trippe, Sascha;Wajima, Kiyoaki;Zhang, Yingkang
    • Journal of The Korean Astronomical Society
    • /
    • v.52 no.1
    • /
    • pp.23-30
    • /
    • 2019
  • The KVN(Korean VLBI Network)-style simultaneous multi-frequency receiving mode is demonstrated to be promising for mm-VLBI observations. Recently, other Very long baseline interferometry (VLBI) facilities all over the globe start to implement compatible optics systems. Simultaneous dual/multi-frequency VLBI observations at mm wavelengths with international baselines are thus possible. In this paper, we present the results from the first successful simultaneous 22/43 GHz dual-frequency observation with KaVA(KVN and VERA array), including images and astrometric results. Our analysis shows that the newly implemented simultaneous receiving system has brought a significant extension of the coherence time of the 43 GHz visibility phases along the international baselines. The astrometric results obtained with KaVA are consistent with those obtained with the independent analysis of the KVN data. Our results thus confirm the good performance of the simultaneous receiving systems for the nonKVN stations. Future simultaneous observations with more global stations bring even higher sensitivity and micro-arcsecond level astrometric measurements of the targets.

A $PbTiO_{3}$ Transmitting/P(VDF-TrFE) Receiving Wideband Ultrasonic Transducer in VHF Band (VHF 대역에 있어서 $PbTiO_{3}$송신/P(VDF-TrFE) 수신 광대역 초음파변환자)

  • Ha, Kang-Lyeol;Kim, Moo-Joon;Kim, Jung-Ho;Kim, Jung-Soon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.4E
    • /
    • pp.120-124
    • /
    • 2004
  • A new type of high frequency wideband ultrasonic transducer with a separation between a transmitter and a receiver was proposed and its characteristics were simulated using a PSpice model. The piezoelectric ceramic $PbTiO_{3}$ as a transmitter and the piezoelectric copolymer P(VDF- TrFE) as a receiver were used for high sensitivity and wide bandwidth, respectively. The characteristics of the focusing transducer with center frequency of approximately 35MHz fabricated in this study showed very wide bandwidth, which could give an axial spatial resolution better than $30{\mu}m$ in B-mode image for biological tissues.

Effect of Sound Stress on Immune Response (소음 스트레스가 면역반응에 미치는 영향에 관한 실험적 연구)

  • 김금재
    • Journal of Korean Academy of Nursing
    • /
    • v.19 no.2
    • /
    • pp.135-146
    • /
    • 1989
  • This study was undertaken to assess the effect of sound stress on humoral and cellular immune responses to thymus-dependent and independent antigens in mice. After mice were exposed to 4 hr daily sound stessors(83㏈) for 4 days before or after immunization, the primary and / or secondary immune response to sheep red blood cells(SRBC), polyvinylpyrroridone(PVP) or picry1 chloride(TNCB) were assayed. When mice were exposed to sound stressor before or after immunization, delayed-type hypersensitivity reaction and contact sensitivity to TNCB was remarkably depressed compared with those of the unstressed control mice. However, the primary and secondary hemagglutinin response of the stresed mice to SRBC showed a pronounced increase compared with that of the unstressed mice, In contrast to antibody response to SRBC, the primary antibody response of the stressed mic to PVP was almost not detected. surprisingly, the secondary antibody response to PVP of the mice receiving the secondary sound stress was markedly increased when the immune-depressed mice received the secondary immunization with PVP at 46 days after the primary immunization. The susceptibility of mice to intraven-oulsy infected Candida albicans was not changed by the sound stress.

  • PDF

Characteristics of a $PbTiO_{3}$ Transmitting/P(VDF-TrFE) Receiving Ultrasonic Transducer in VHF Band

  • Ha Kang-Lyeol;Kim Moo-Joon;Kim Jung-Ho;Kim Jung-Soon
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.311-314
    • /
    • 2004
  • A new type of high frequency wideband ultrasonic transducer with a separation between a transmitter and a receiver was proposed and its characteristics were simulated using the PSpice model. The piezoelectric ceramic $PbTiO_{3}$ as a transmitter and the piezoelectric copolymer P(VDF-TrFE) as a receiver were used for high sensitivity and wide bandwidth, respectively. The characteristics of a center frequency approximately 40MHz focusing transducer fabricated in this study showed very wide bandwidth which could give an axial spatial resolution better than 30um in the B-mode image for biological tissues.

  • PDF

A Study of Frequency variable Ultrasonic Transducer for the Variation of Echo Characteristics in Reflecte Wave (반사파의 주파수 성분변화에 대응한 주파수 가변 초음파 트랜스듀서)

  • 김무준
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1997.06a
    • /
    • pp.40-43
    • /
    • 1997
  • It is known tat the echoes from the most objects differ from the incident pulses in amplitude and frequency .Especially, the frequency in echoes from moving target is shiftby the Doppler effect. it causes to reduce the receiving sensitivity of piezoelectric transducers that have definite band width. The electric impedance, whichis connected to the electrical terminals, notably changes the resonant frequency of a thickeness mode piezoelectric vibrator with high electromechanical doupling due to the electroelastic effect. Using this effect, we have developed a frequency controllable ultrasonic transducer which is mad eof multi-layered PZT disks to adjust to frequency shifted by Doppler effect. The characteristics of transducer can be obtained by using the equivalent circuit of transmission line model. It was confirmed experimentally that the center frequency and band width of the trasducer could be controlled by the conditions of the electrical terminals. These results coincided with theoretical results.

  • PDF

Analysis of Transmitter Leakage Effects in a FM-CW Radar (FM-CW 레이다에서의 송신 누설 전력 영향 분석)

  • Lee, Jong-Gil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.50-51
    • /
    • 2011
  • In a radar system using a continuous waveform, the separated antennas are needed for transmission and reception to increase the sensitivity of the receiver channel. Even for these separated antennas, the serious intereference in the weak echo signal can occur due to the relatively strong power of the transmitted waveform. Therefore, in this paper, the effects of this leakage interference on the receiving signal are analyzed according to the degree of antenna isolation.

  • PDF

A new algorithm of pulse generation and detection for UWB communication system (UWB통신 시스템을 위한 새로운 펄스생성 방법 및 수신 알고리즘)

  • 김건수;윤상훈;정정화;이경국
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.242-245
    • /
    • 2003
  • This paper introduces a new algorithm of pulse generation and detection for UWB communication system. The existing UWB systems using Gaussian pulse have some difficulties to cope with bandwidth limitation and frequency transition. Moreover. the system sensitivity to channel noise has made the processes of acquisition and tacking difficult. in this paper, we introduce a new pulse generation method which is able to control the bandwidth and center frequency applying modulation method. thus could improve the detection performance of receiving algorithm. Also, we made a system to search maximum perk by applying the proposed algorithm and consequently could guarantee the correct detection. By the result of simulation, when accumulate 10 times at every 2dB band shifting from 0 to 18dB on AWGN channel, we could confirm the proposed method has 97.4% PDR(Pulse Detection Rate) and 1.868% FAR(False Alarm Rate) performance at 4dB SNR and 15% transmission power threshold level.

  • PDF

Development of Wireless Instrument for Measuring Cattle's Somatic Information for Stockbreeding Automatization(II) - Development of Single-Channel Wireless Instrument for Measuring Sphygmus - (축산자동화를 위한 가축의 생체정보 무선 계측장치 개발(II) - 단일채널 무선 맥박 계측장치 개발 -)

  • Lee, S.K.;Min, Y.B.;Kim, T.K.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.4
    • /
    • pp.404-409
    • /
    • 1992
  • It is important to measure the somatic informations for stockbreeding automatization. This study was carried out for the development of wireless measurement system of sphygmus in living animals. In meauring sphygmus counting with the single-channel telemety system, a LED-photo transistor sensor showed more sensitivity to the change of blood pressure than a piezo-electric sensor based pressure sensor. The LED-photo transistor sensor resulted ${\pm}1.29%$ of measurement error of sphygmus counting. In the process of transmitting and receiving the blood pressure signal for counting sphygmus, noises were mixed with, and the noises made the counting almost impossible. Auto-correlation analysis technique was applied to the signal data to extract the sphygmus information, and the technique was proved to be very effective.

  • PDF

Bandwidth Enhancement of Underwater Acoustic Transducer Using a Bandpass Matching Network (대역통과 정합회로를 이용한 수중음향변환기의 대역폭 확장)

  • Lee, Dae-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.52 no.6
    • /
    • pp.702-708
    • /
    • 2019
  • The range resolution of echo sounders can be improved by enhancing the transducer bandwidth. We designed a bandpass matching network for expanding the bandwidth of a transducer by scaling in both impedance and frequency after transforming a lowpass network into a bandpass configuration for a third-order Bessel filter. We measured the effect of the Bessel matching network for a 50 kHz sandwich type transducer on the transmitting voltage response (TVR), receiving sensitivity (SRT) and figure of merit (FOM), using a chirp echo sounder system. Both the simulation and experimental results indicated that the transducer with a bandpass matching network was capable of producing a symmetrical acoustic output over a wider bandwidth (8.25 kHz) than was the transducer without a matching network (3.75 kHz). By implementing the Bessel matching network, we achieved a 120% bandwidth enhancement.