집속초음파 자극기의 성능평가를 위한 팬텀 내부온도 측정 (Measurement of Internal Temperature Distribution for the Evaluation of Focused Ultrasound (FUS) Stimulation Devices)

  • 도일;조주형;김성목;백경민;김용태;박승민
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권3호
    • /
    • pp.147-152
    • /
    • 2022
  • This research is to measure real-time temperature distribution inside a tissue-mimicking phantom for the safety and effectiveness evaluations of focused ultrasound (FUS) device capable of linear scanning stimulation. Since the focusing area of the FUS stimulation device is smaller than diameter of conventional thermal probe and keeps moving, it is impossible to monitor temperature distribution inside the phantom. By using the phantom with a thin film temperature sensor array inserted, real-time temperature change caused by the FUS device was measured. The translation of the measured temperature peak was also tracked successfully. The present phantom had been experimentally proven to be applicable to validate the performance and safety of the therapeutic ultrasound devices.

The Effect of Real-time Ultrasound Imaging Feedback during Abdominal Hollowing in Four Point Kneeling to Healthy Men

  • Park, Du-Jin
    • The Journal of Korean Physical Therapy
    • /
    • 제22권6호
    • /
    • pp.1-6
    • /
    • 2010
  • Purpose: This study investigated the effects of visual feedback during abdominal hollowing (AH) in four point kneeling position, using real-time ultrasound imaging through measurement of the changes in the thickness of transversus abdominis (TrA), internal abdominal oblique (IO), and external abdominal oblique (EO). Methods: The subjects of this study were 32 healthy males who were divided intothe experimental group of 16 subjects and the control group of 16 subjects. The real-time ultrasound feedback was applied to the experimental group while they were educated on the AH exercise in four point kneeling whereas only general education and training were given to the control group. After the training, the changes in the thickness of abdominal muscles during AH in four point kneeling were compared between the experimental group and the control group. Results: The differences of the changes in the thickness of TrA and EO between the two groups were statistically significant. Conclusion: The experimental group experienced a higher increase in the thickness of TrA than the control group while the thickness of IO and EO of the experimental.

Infrared Thermography Characterization of Defects in Seamless Pipes Using an Infrared Reflector

  • Park, Hee-Sang;Choi, Man-Yong;Park, Jeong-Hak;Lee, Jea-Jung;Kim, Won-Tae;Lee, Bo-Young
    • 비파괴검사학회지
    • /
    • 제32권3호
    • /
    • pp.284-290
    • /
    • 2012
  • Infrared thermography uses infrared energy radiated from any objects above absolute zero temperature, and the range of its application has been constantly broadened. As one of the active test techniques detecting radiant energy generated when energy is applied to an object, ultrasound infrared thermography is a method of detecting defects through hot spots occurring at a defect area when 15~100 kHz of ultrasound is excited to an object. This technique is effective in detecting a wide range affected by ultrasound and vibration in real time. Especially, it is really effective when a defect area is minute. Therefore, this study conducted thermography through lock-in signal processing when an actual defect exists inside the austenite STS304 seamless pipe, which simulates thermal fatigue cracks in a nuclear power plant pipe. With ultrasound excited, this study could detect defects on the rear of a pipe by using an aluminium reflector. Besides, by regulating the angle of the aluminium reflector, this study could detect both front and rear defects as a single infrared thermography image.

Indoor Positioning System for Moving Objects on an Indoor for Blind or Visually Impaired Playing Various Sports

  • Lee, Young-Bum;Lee, Myoung-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.131-134
    • /
    • 2009
  • We have proposed an indoor positioning system for moving objects and/for the blind or visually impaired to play various sports. [ for a blind or visually impaired playing various sports.] This system consists of a wireless heart rate monitor, wireless sensor network and / 4 ultrasound satellites [ configuration with four ultrasound satellite modules) at the corners of the room. This system provides / the real-time measurement of the location and heart rate of the person in the room[ non-invasive measurement method of the heart rate and the location of a person in real time ], and will help the [a] blind or visually impaired enjoy sports more easily.

초음파를 이용한 턱관절질환의 진단과 초음파 가이드의 활용 (Diagnostic Application of Temporomandibular Joint Disorder and Ultra Sound Guided Oral &Maxillofacial application)

  • 성태환;박정현;김선종
    • 대한치과의사협회지
    • /
    • 제55권11호
    • /
    • pp.789-799
    • /
    • 2017
  • Ultrasound images are noninvasive, can be observed in real time, have no radiation exposure, do not cause pain, and are not restricted in use depending on the patient's prosthetic implant or medical condition. Since the use of ultrasound in the dental field was first applied for tooth preparation in 1957, the use of diagnostic ultrasound for the first time in 1963 has been reported. Currently, it is used in the diagnosis of soft tissue lesions such as malignant tumor or salivary gland disease, fine needle aspiration test, temporomandibular joint disease, lymph node metastasis, measurement of muscle thickness and inflammatory diseases, differentiation of periapical cyst and granulation tissue, measurement of periodontal tissue thickness. The ultrasound image can be visualized in real time. The clinician can explain the structure to the patient while consulting the patient and consult the patient. When injecting the drug into a specific site or aspirating a specific site or substance, So that it can be confirmed and practiced. Recently, ultrasonic equipment specialized in the dental field has been developed and marketed, and it is expected that the use of ultrasonic waves will become active in the dentistry. In the future, development of popular equipment with size and frequency suitable for dental diagnosis and various researches on maxillofacial ultrasonic anatomy. If clinical studies are continuously carried out to demonstrate efficacy, ultrasound is expected to aid in accurate diagnosis and treatment throughout the dentistry.

  • PDF

Accuracy of Ultrasonography in Early Pregnancy Diagnosis in Doe

  • Singh, N.S.;Gawande, P.G.;Mishra, O.P.;Nema, R.K.;Mishra, U.K.;Singh, Mohan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제17권6호
    • /
    • pp.760-768
    • /
    • 2004
  • The present study was undertaken to evaluate the accuracy of ultrasonography in early pregnancy diagnosis in goats. Ultrasonographic scanning with real time B-mode ultrasound machine having 5 MHz linear array transducer was performed on gravid uterus (n=24) obtained from slaughterhouse (Group I). Crown rump length (CRL) measured by ultrasound was found significantly different (p<0.05) with actual CRL measured after dissection in early pregnancy. However, age predicted by ultrasound through the measurement of CRL was found highly correlated (r=0.92) with age measured after dissection through CRL and the weight of fetus. Ages predicted by ultrasound through the measurement of trunk diameter (TD) and uterine diameter (UD) and ages measured after dissection were found highly and equally correlated (r=0.98) and did not differ significantly. Data from six does synchronized (Group II) with PGF2$\alpha$ (Estrumate) at 11 days apart were collected through ultrasound from 17 to 42 days post breding. The correlation between CRL and gestational age was high (r=0.97) in day 30 to 42 post breeding. A high coefficient of correlation (r=0.98) was also observed between predicated age by ultrasound and actual age calculated after kidding. The correlation between CRL and gestational age by the formula Y=(a+bX) i.e. Y=24.42+0.39 X where Y=gestational age and X=CRL, was recorded very high (r=0.99). Accuracy of ultrasonography was lowest on day 17 to 19 (66%) and reached 100% on day 34. Data from 30 does (group III) randomly subjected to only one time ultrasounds scanning to assess the accuracy of pregnancy diagnosis were also obtained. Ages predicted by TD and UD measurements were observed to be non-significantly different with actual age obtained after kidding and correlation between ages predicted by TD and UD measurement with actual age after kidding was found equally and highly correlated (r=0.98). The operator's accuracy in the whole experiment including all three groups was found to be 92%. The sensitivity was 93% and specificity was 86%. From the present study, it was observed that CRL was the most reliable parameter to find out gestational age in early pregnancy and the new formula derived was found very accurate to find out gestational age. TD and UD were also found to be equally reliable parameter to find out gestational age in mid and late stage of pregnancy through ultrasonography. It was concluded that ultrasonography by real time B mode with 5 MHz transrectal transducer was found to be reliable, safe and accurate and practicable means in diagnosing early pregnancy diagnosis as early as 25 days post breeding.

Genetic Analysis of Ultrasound and Carcass Measurement Traits in a Regional Hanwoo Steer Population

  • Hwang, Jeong Mi;Cheong, Jae Kyoung;Kim, Sam Su;Jung, Bong Hwan;Koh, Myung Jae;Kim, Hyeong Cheol;Choy, Yun Ho
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제27권4호
    • /
    • pp.457-463
    • /
    • 2014
  • Ultrasound measurements of backfat thickness (UBF), longissimus muscle area (ULMA) and marbling score (UMS) and carcass measurements of carcass weight (CW), backfat thickness (BF), longissimus muscle area (LMA), and marbling score (MS) on 7,044 Hanwoo steers were analyzed to estimate genetic parameters. Data from Hanwoo steers that were raised, finished in Hoengseong-gun, Gangwon-do (province) and shipped to slaughter houses during the period from October 2010 to April 2013 were evaluated. Ultrasound measurements were taken at approximately three months before slaughter by an experienced operator using a B-mode real-time ultrasound device (HS-2000, FHK Co. Ltd., Tokyo, Japan) with a 3.5 MHz linear probe. Ultrasound scanning was on the left side between 13th rib and the first lumbar vertebrae. All slaughtering processes and carcass evaluations were performed in accordance with the guidelines of beef grading system of Korea. To estimate genetic parameters, multiple trait animal models were applied. Fixed effects included in the models were: the effects of farm, contemporary group effects (year-season at the time of ultrasound scanning in the models for UBF, ULMA, and UMS, and year-season at slaughter in the models for CW, BF, LMA, and MS), the effects of ultrasound technicians as class variables and the effects of the age in days at ultrasound scanning or at slaughtering as linear covariates, respectively for ultrasound and carcass measures. Heritability estimates obtained from our analyses were 0.37 for UBF, 0.13 for ULMA, 0.27 for UMS, 0.44 for CW, 0.33 for BF, 0.36 for LMA and 0.54 MS, respectively. Genetic correlations were strongly positive between corresponding traits of ultrasound and carcass measures. Genetic correlation coefficient between UBF and BF estimate was 0.938, between ULMA and LMA was 0.767 and between UMS and MS was 0.925. These results suggest that ultrasound measurement traits are genetically similar to carcass measurement traits.

골밀도 측정을 위한 초음파 영상 개선에 관한 연구 (Study on enhancing the ultrasonic image for bone densitometry)

  • 신정식;안중환;김형준;김화영;한승무
    • 한국정밀공학회지
    • /
    • 제22권8호
    • /
    • pp.182-191
    • /
    • 2005
  • It is very important to obtain a high quality of bone image for an accurate ultrasonic measurement of bone mineral density. In this study, we suggested a technique to acquire an optimal image by adapting an acoustic lens and a properly selected ultrasonic probe. Also, we have applied an image processing algorithm with which automatically makes a decision of brightness and contrast of image by generating threshold level, a composition of ultrasonic data, an elimination of noise using modified median filter, and a real time interpolation. We could confirm much improved resolution of bone image with acoustic lens attached to the ultrasonic probe and with the image processing algorithm suggested in this study. Therefore, it became possible to precisely diagnose the osteoprosis using ultrasonic imaging technique.

한우 초음파생체단층촬영 형질에 대한 유전모수 추정과 씨수소 선발에 관한 연구 (Studies on Genetic Parameter Estimation and Sire Selection to Ultrasound Measurement Traits of Hanwoo)

  • 노승희;김창엽;원유석;박철진;이성수;이정규
    • Journal of Animal Science and Technology
    • /
    • 제52권1호
    • /
    • pp.1-8
    • /
    • 2010
  • 본 연구는 한우초음파생체단층촬영 자료를 이용하여 한우개량을 위한 기초자료로 활용코자 실시하였다. 당대검정우 1,125두에 대하여 초음파생체단층 촬영한 자료와 검정성적자료 및 12개월령에 거세한 후 30개월령까지 비육 후 출하하여 도체성적을 조사한 자료를 이용하였으며, 후대검정우는 921두에 대한 검정성적자료와 도체 성적자료를 이용하였다. 12개월령에 측정한 초음파생체단층 촬영 배최장근단면적과 등지 방두께의 유전력은 각각 0.57, 0.41로 추정되었으며, 24개월에서는 각각 0.57, 0.60으로 고도의 유전력을 보였다. 그러나, 초음파 측정 %지방함량 유전력 추정치에서는 12개월령과 24개월령에서 각각 0.14, 0.22로 저 중도의 유전력을 보였다. 12개월령에 초음파생체 단층 촬영한 배최장근단면적, 등지방두께, %지방함량과 도체형질의 배최장근단면적, 등지방두께, 근내지방도의 유전상관은 각각 0.616, 0.544, 0.501로 추정되었고, 24개월령에서는 각각 0.894, 0.937, 0.263으로 높은 유전상관을 보였다. 12개월령에 측정한 초음파 측정 %지방함량과 근내지방도에서 높은 유전상관으로 추정되었는데, 이는 24개월령에서는 환경적요인(사양기술 등)에 의해 영향을 많이 받은 것으로 사료되며, 선발에 활용할 경우 24개월령 측정치 보다는 12개월령 측정치를 이용하는 것이 더 바람직할 것으로 사료된다. 12개월령 체중과 도체형질을 이용하여 씨수소를 선발하는 선발지수와 이와 유전상관이 높은 초음파생체단층촬영 자료를 바탕으로 선발하는 선발지수간의 순위상관을 분석한 결과 12개월령에 초음파생체단층 촬영한 자료에서 후보씨수소 선발지수는 0.140, 보증씨수소 선발지수는 0.843으로 높은 순위상관을 보였다. 본 연구결과 실시간으로 배최장근단면적, 등지방두께, 근내지방도와 같은 도축하지 않아도 도체성적을 파악할 수 있는 초음파생체단층 촬영 기술의 장점을 이용하여 선발에 활용한다면 근내지방도는 24개월령에 측정하는 것보다 12개월령에 측정하는 것이 더 효율적이라고 사료되어지며, 향후 초음파생체단층기술에 관한 더 많은 연구를 통하여 종축선발에 활용한다면 씨수소의 조기선발이 가능할 것으로 사료된다.

Auto-Correlation을 이용한 펄스 도플러 시스템에 관한 연구 (A study on the development of Pulsed Doppler System using Auto-Correlation)

  • 임춘성;강충신;이행세;김영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.705-708
    • /
    • 1988
  • Ultrasound Doppler Diagnostic System utilizes the Doppler effect for measurement of blood velocity. The sign of the Doppler frequency shift represents blood flow direction. Pulsed Doppler System uses Phase detector and zerocrossing method to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction in the time domain, had been fabricated. But time-domain analyzing such as audio evaluation and zerocrossing detection for instantaneous and mean frequency measurement doesn't, provide both an accurate and quantitative result. Therefore, it is necessary to adopt frequency domain technique to improve system performance. In this paper, we describe a unit which is composed of Pulsed Doppler System and real-time spectrum analyzer (installed TMS 32010 DSP Chip). This unit shows time-dependent spectrum variation and mean velocity of blood Signal.

  • PDF