• Title/Summary/Keyword: Real-time telemetry

Search Result 81, Processing Time 0.022 seconds

3D DISPLAY OF SPACECRAFT DYNAMICS USING REAL TELEMETRY

  • Lee, Sang-Uk;Cho, Sung-Ki;Kim, Jae-Hoon
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.4
    • /
    • pp.403-408
    • /
    • 2002
  • 3D display of spacecraft motion by using telemetry data received from satellite in real-time is described. Telemetry data are converted to the appropriate form for 3-D display by the real-time preprocessor. Stored playback telemetry data also can be processed for the display. 3D display of spacecraft motion by using real telemetry data provides intuitive comprehension of spacecraft dynamics.

Implementation of Wavelet Transform for a Real time Monitoring ECG Telemetry System (웨이브렛 변환을 이용한 실시간 모니터링 ECG 텔레미트리 시스템 구현)

  • 박차훈;서희돈
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.1
    • /
    • pp.27-32
    • /
    • 2002
  • In this study, we fabricated the advanced telemetry system that transmitting media use radio frequency(RF) for the middle range measurement of the physiological signals and receiving media use optical for electromagnetic interference problem. The telemetry system within a size of 65$\times$125$\times$45mm consists of three parts: RF transmitter, optical receiver and physiological signal processing CMOS one chip. Advantages of proposed telemetry system is wireless middle range(50m) FM transmission, reduce electromagnetic interference to a minimum which enables a comfortable bed-side telemetry system. The monitoring system was designed in the structure of dual-processor for the real time processing. The use of the one channel in our study made it possible the real time wavelet transformation of electrocardiogram data of 360Hz, 16 bits for every 1.42 seconds.

  • PDF

Telemetry Data Downlink Management of Low Earth Orbit Satellite (저궤도위성 원격측정 데이터 다운링크 관리)

  • Chae, Dongseok;Yang, Seung-Eun;Cheon, Yee-Jin
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.4
    • /
    • pp.111-116
    • /
    • 2013
  • Because LEO (Low Earth Orbit) satellite has very limited contact time between satellite and ground station, all telemetry data generated on satellite are stored in a mass memory and transmitted to the ground during the contact time. There are two downlink modes, real-time mode and playback mode. Only real-time data frames are transmitted to the ground in real-time mode, real-time and playback data frames stored into mass memory are transmitted to the ground in playback mode. In accordance with the data transmission rate, there are two downlink rates, low downlink rate and high downlink rate. This paper briefly introduces downlink interfaces and flight software of a LEO satellite developed in KARI. And it presents the telemetry storage method, real-time and playback downlink management method, and downlink channel and rate control method.

PCM Encoder Structure for Real-time Updating of Telemetry System Parameters (원격 측정 시스템 파라미터 실시간 업데이트 PCM 엔코더 구조)

  • Park, Yu-Kwang;Yoon, Won-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.5
    • /
    • pp.452-459
    • /
    • 2019
  • In this paper, we describe a PCM encoder structure that can update the telemetry system parameters in real time. In the PCM encoder, an analog signal control unit for FPGA, flash memory, and sensor data acquisition was constructed. UART communication, analog signal control, flash memory control, and frame generation are possible through logic inside FPGA of PCM encoder. UART communication allows the PC to transmit parameter data to the PCM encoder, and flash memory is controlled to update the parameter of the telemetry system in real time and finally the frame is formed. Simulation and verification were performed to confirm whether the parameter data is updated in real time, and the proposed structure was used to construct a telemetry system with enhanced flexibility and convenience.

Development of a Real-Time Water Quality Monitoring System using Coastal Passenger Ships and PCS Telemetry

  • Jin, Jae-Youll;Park, Jin-Soon;Lee, Jong-Kuk;Park, Kwang-Soon;Lee, Dong-Young;Yum, Ki-Dai
    • Ocean and Polar Research
    • /
    • v.21 no.2
    • /
    • pp.117-126
    • /
    • 1999
  • To meet increasing needs for environmentally sustainable management of coastal area, there has been compelling pressure to establish a cost-effective and long-term coastal water quality (CWQ) monitoring system. A remote CWQ monitoring system, STAMP, has been developed and is in operation along the route between Kyema harbor and Anma Island in the southwestern coastal area of Korea. STAMP uses a PCS phone as a telemetry unit to transmit acquired data for monitoring general water quality parameters, and a routinely operating coastal passenger ship or car ferry. STAMP has various merits of low-cost operations; long-term monitoring with secure instrumentation; and stable real-time telemetry of acquired data with-out the loss and noise. It is expected that the system will serve as a very useful tool in the CWQ managing programs of Korea taking the advantage of many coastal passenger ships in various routes including the ships departing from the coastal industrial cities. The acquired data compiled on suspended surface sediment concentrations (SSSC) will be also valuably helpful in understanding the sediment budget across the routes of the vessel.

  • PDF

Study of the Telemetry Ground Station for FA-50 Flight Test Instrumentation System (신규 형상에 따른 FA-50 지상계측 방안 연구)

  • Lee, Ju-Ha;Kim, Bo-Sung;Yoo, Byeong-Seon
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.16 no.4
    • /
    • pp.20-25
    • /
    • 2008
  • The purpose of this study is leading to reduce the setup time and cost of the ground telemetry system for FA-50 program. And using the accumulated experience during T-50 and TA-50 development period, remove the risk of development and construct the optimal ground telemetry system for FA-50. For this study, collect the ground telemetry data of the T-50/TA-50, analyze the data and problems and then suggest the optimal telemetry ground system for FA-50.

  • PDF

Implementation of a portable telemetry system based on wavelet transform. (웨이블릿 알고리즘을 적용한 휴대용 텔레미트리 시스템)

  • 박차훈;서희돈
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.113-116
    • /
    • 2000
  • In this paper presents the portable wireless ECG data detection and diagnosis system based on discreet wavelet transform. An algorithm based on wavelet transform suitable for real time implementation has been developed in order to detect ECG characteristics. In particular, QRS complex, S and T waves may be distinguished form noise, baseline drift or artifacts. Proposed telemetry system that a transmitting media using radio frequency(RF) for the middle range measurement of the physiological signals and receiving media using optical for electromagnetic interference problem. A standard hi-directional serial communication interface between the telemetry system and a personal computer or laptop, allows read-time controlling, diagnosing and monitoring of system. A portable telemetry system within a size. of 65${\times}$125${\times}$45mm consists of three parts: a digital signal processing part for physiological signal detect or diagnose, RF transmitter for data transfer and a optical receiver for command receive. Advantages of proposed telemetry system is wireless middle range(50m) FM transmission, reduce electromagnetic interference to a minimum. which enables a comfortable diagnosis system at home.

  • PDF

Design and Development of MIMIC regarding Telemetry in LEO Satellites (저궤도 관측위성에서의 원격 측정 데이터 관련 MIMIC 설계 및 구현)

  • Huh, Yun-Goo;Kim, Young-Yun;Cho, Seung-Won;Choi, Jong-Yeoun
    • Aerospace Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.42-48
    • /
    • 2012
  • The telemetry data received from satellite in real-time are used to monitor LEO satellite during the AIT (Assembly, Integration & Test) phase and the mission operation phase after launch. However, it is impossible to check all the incoming telemetry data from satellite in real time in order to detect abnormality of satellite quickly. Especially, the contact time of LEO satellite is limited because of its orbital characteristics. So the anomaly state of the LEO satellite should be detected and resolved during the contact time. Therefore, all incoming spacecraft telemetry data must be selected and manipulated in MIMIC. It is used in order to display summarized information about spacecraft in a visualized way that is quickly and easily understood. That is, it provides essential function to monitor a satellite both in orbit and during testing. In this paper, the design and development of MIMIC currently used in KOMPSAT, a LEO Earth observation satellite is described in detail. In future work, we plan to enhance MIMIC in order to improve user-friendliness and efficiency.

Passive Telemetry Sensor System using RLSE Based Real Time Estimation Technique with Optimal Forgetting Factor

  • Lee, Joon-Tark;Kim, Kyung-Yup
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2004.10a
    • /
    • pp.515-520
    • /
    • 2004
  • In this paper, a passive telemetry RF capacitive humidity sensor system using a RLSE(Recursive Least Square Estimation) technique is proposed. To overcome these trouble problems such as a power limitation and a estimation complexity that the general passive telemetry sensor system including It chip has, the principle of inductive coupling was applied to the modeling of a passive telemetry RF capacitive humidity sensor system and its capacitance was estimatedd by the RLSE algorithm. Specially, by introducing the optimal forgetting factor, we showed that the accuracy of its estimation was improved even in the time varying system and also the convergence time was reduced.

  • PDF

Study on the Biomedical Signal Processing System (신호처리 알고리즘을 적용한 생체신호처리 시스템에 관한 연구)

  • 박차훈;김태선
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2001.05a
    • /
    • pp.252-255
    • /
    • 2001
  • The purpose of this study is to realize the real time monitoring ECG telemetry system applied by the telemetry unit, in which transmission is made through the electronic wave and reception is made through the light, and by the wavelet algorithm as well. A light receiver via existing telemetry unit which is based on baseband, the reception length was 50cm, but when the frequency modulation is used, the reception length is extended to 3m. In addition to this, we have found that the full-duplex method of transmission became available by using dual-mechanism.

  • PDF