• Title/Summary/Keyword: Real-time ethernet

Search Result 149, Processing Time 0.028 seconds

Preemptive Ethernet Controller to Improve Real-Time Characteristics of IEC 61850 Protocol (IEC 61850 프로토콜의 실시간성 향상을 위한 선점형 이더넷 컨트롤러)

  • Lee, Bum-Yong;Park, Tae-Rim;Park, Jae-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1923-1928
    • /
    • 2010
  • The IEC 61850 protocol proposed for the interoperability between IEDs(intelligent electronic devices) adopts the prioritized switched ethernet as its communication channel because substation bus is utilized to exchange both real-time and non real-time messages. The prioritized switched ethernet uses IEEE 802.1Q/p QoS(Quality of Service) in addition to IEEE 802.3 ethernet to enhance the real-time characteristics. However, IEEE 802.1Q/p QoS has priority-blocking problem that occurs when higher-priority frame transmission request during lower-priority frame transmission. To resolve this problem, this paper proposes P(Preemptive)-Ethernet. P-Ethernet uses the modified IEEE 802.1Q/p frame format and new priority preemption mechanism. This paper also implements P-Ethernet controller using FPGA (Virtex-4) and MicroBlaze processor. From the implementation results, P-Ethernet controller shows a improved latency and jitter of transmission period compare to the normal ethernet controller.

Performance Evaluation of Switched Ethernet for Real-time Industrial Communication (실시간 산업용 통신을 위한 Switched Ethernet의 성능 평가)

  • Lee, Kyung-Chang;Kim, Tae-Jun;Lee, Seok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.1
    • /
    • pp.90-98
    • /
    • 2003
  • The real-time industrial network, often referred to as fieldbus, is an important element for building automated manufacturing systems. Thus, in order to satisfy the real-time requirements of field devices, numerous fieldbus protocols have been announced. But the application of fieldbus has been limited due to the high cost of hardware and the difficulty in interfacing with multi-vendor products. Therefore, as an alternative to fieldbus, the computer network technology, especially Ethernet (IEEE 802.3), is being adapted to the industrial environment. However, the crucial technical obstacle for Ethernet is its non-deterministic behavior that makes it inadequate for industrial applications where real-time data have to be delivered within a certain time limit. Recently, the development of switched Ethernet shows a very promising prospect for industrial application due to the elimination of uncertainties in the network operation resulting in much improved performance. This paper focuses on the application of the switched Ethernet for industrial communications. More specifically, this paper presents an analytical and experimental performance evaluation of the switched Ethernet and a case study about networked control system.

Performance Evaluation of Switched Ethernet for Real-time Industrial Communication (실시간 산업용 통신을 위한 Switched Ethernet의 성능 평가)

  • Kim, D. H.;Lee, K. C.;Lee, S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.491-494
    • /
    • 2002
  • The real-time industrial network often referred to as fieldbus, is an important element for building automated manufacturing systems. Thus, in order to satisfy the real-time requirements of field devices such as sensors, actuators, and controllers. numerous standard organizations and vendors have developed various fieldbus protocols such as Profibus, WorldFIP and Foundation Fieldbus. However, the application of fieldbus has been limited due to the high cost of hardware and the difficulty in interfacing with multi-vendor products. In order to solve these problems, the computer network technology, especially Ethernet (IEEE 802.3), is being adopted lo the industrial environment. The crucial technical obstacle for Ethernet is that its non-deterministic behavior makes it inadequate for industrial applications where real-time data such as control command and alarm signal hale to be delivered within a certain time limit. Recently, the development of switched Ethernet shows a very promising prospect for industrial application due to the elimination of uncertainties in the network operation resulting in much improved performance. This paper focuses on the application of the switched Ethernet for industrial comm unications.

  • PDF

A Feasible Condition for EDF-based Scheduling of Periodic Messages on a Synchronized Switched Ethernet (동기식 스위칭 이더넷에서 주기적 메시지에 대한 마감시간우선 기반 메시지 스케쥴링을 위한 조건)

  • Kim, Myung-Kyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.4
    • /
    • pp.403-410
    • /
    • 2010
  • The switched Ethernet has many features for real-time communications such as providing traffic isolation, large bandwidth, and full-duplex links, and so on. The switched Ethernet, however, cannot guarantee the timely delivery of a real-time message because message delay increases when collisions occurs at the output ports and message loss can even occur due to the overflow at the output buffer. Recently, many research efforts have been done to use the switched Ethernet as an industrial control network. In the industrial control network, sensors periodically sense the physical environment and transmit the sensed data to an actuator, and the periodic messages from sensors to actuators have typically real-time requirements such that those messages must be transmitted within their deadlines. This paper first suggests a feasible condition for EDF (Earliest Deadline First)-based scheduling of periodic messages on a synchronized switched Ethernet and a message scheduling algorithm which satisfies the proposed feasible condition. Pedreiras, et al. [10] suggested a feasible condition for message scheduling on the Ethernet (shared media Ethernet), but there has been no research result on the scheduling condition on the switched Ethernet until now. We compared the real-time message scheduling capacity between the Ethernet and the switched Ethernet by simulation. The simulation result shows that the message scheduling capacity of the Ethernet has almost remained constant as the number of nodes on the network increases, but, in the case of the switched Ethernet, the message scheduling capacity has increased linearly according to the number of nodes on the network.

Real-time transmission properties of industrial switched Ethernet with cascade structure (다계층 구조를 가진 산업용 스위치드 이더넷에서의 실시간 전송 특성)

  • Lee, Kyung-Chang;Lee, Seok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.8
    • /
    • pp.718-725
    • /
    • 2004
  • The real-time industrial network, often referred to as fieldbus, is an important element for intelligent manufacturing systems. Thus, in order to satisfy the real-time requirements of field devices, numerous fieldbus protocols have been announced. But, the application of fieldbus has been limited due to the high cost of hardware and the difficulty in interfacing with multi-vendor products. Therefore, as an alternative to fieldbus, the computer network technology, especially Ethernet (IEEE 802.3), is being adapted to the industrial environment. However, the crucial technical obstacle for Ethernet is its non-deterministic behavior that makes it inadequate for industrial applications where real-time data have to be delivered within a certain time limit. Recently, the development of switched Ethernet shows a very promising prospect for industrial application due to the elimination of uncertainties in the network operation resulting in much improved performance. This paper focuses on the application of the switched Ethernet with cascade structure for industrial communications. More specifically, this paper presents an analytical performance evaluation of switched Ethernet with cascade structure, and a case study about networked control system.

The Design & Implementation of Fieldbus Bridge for Integration of different Fieldbus networks (이기종 필드버스 통합을 위한 필드버스 게이트웨이 설계 및 구현)

  • Lee, Yeong-Min;Kim, Myung-Kyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.116-120
    • /
    • 2011
  • In this paper, we have designed and implemented the integrated protocol gateway for the integration of CAN and Profibus networks. To do that, we used the Switched Ethernet as Backbone network, and each fieldbus network is connected by CAN/Ethernet or Profibus/Ethernet gateway, and each gateway perform the translation between fieldbus and Ethernet frames. Futhermore, we realized the real-time features in the environment of the Switched Ethernet by applying the distributed hard real-time scheduling algorithm among each gateways. To implement tht CAN/Ethernet and Profibus/Ethernet gateways, we used the Linux of kernel 2.6.31.12 real-time patched version(PREEMTED_RT), and we could verify successful message translation and real-time features through real implementation.

  • PDF

Ethernet with Virtual Polling Algorithm for real-Time Industrial Communication Network (실시간 산업용 네트워크를 위한 가상 폴링 기반 이더넷 구현)

  • Kim, T. J.;Lee, K. C;Lee, S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.602-605
    • /
    • 2001
  • This paper focus on a method to use Ethernet Network for Industrial Communication Network. Ethernet use the CSMA/CD MAC(Medium Access Control) Protocol at the Data-Link Layer, Which isn't suit for Industrial Communication Network requiring Real-Time Communication, periodic data processing, critical data processing characteristics. In this paper we proposed the Virtual Polling Algorithm at the Application Layer will be solution of using the Ethernet Network for the Industrial Communication Network, Proposed Algorithm terminate the Collision in the network thus Delay Time is reduced and Real-Time Communication will be implemented.

  • PDF

Development and Analysis of Korea Open Source Motion System based on Real-Time Ethernet (실시간 이더넷 기반의 한국형 오픈소스 모션 시스템 개발 및 분석)

  • Lim, Sun;Lee, Seung-Yong;Kim, Ji-Hyun;Jung, Il-Kyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.186-193
    • /
    • 2017
  • KOSMOS is Korea Open Source MOtion System which is developed based on general purpose hardware and open source software. It is aiming at IEC 61131-3 standard. Real-time ethernet has several advantages for motion control system and distributed control system. So, considering this advantages, KOSMOS has the network interface made up of Real-time ethernet, EtherCAT. In this paper, we explain the KOSMOS platform, the performance for real-time task and show the real case applying KOSMOS platform in manipulator control system.

Redundancy Method for Industrial Real-time Ethernet for NPPs (원전용 실시간 제어망을 위한 실시간 이더넷 기술의 마스터 이중화 기법)

  • Yun, Jin-Sik;Kim, Yun-Seop;Kim, Dong-Sung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.71-79
    • /
    • 2011
  • This paper proposes a reliability enhancement of industrial real-time Ethernet using master redundancy method for NPPs(Nuclear Power Plants). In this paper, Ethernet Powerlink is investigated for distributed control systems for NPPs considering real-time and reliability performance. The proposed method can reduce a master switch-over time using PReq signal when Ethernet Powerlink master(Managing Node) failure was occurred. Using the OPNET simulation results, the performance enhancement of master switch-over time of Ethernet Powerlink is verified for NPPs.

Real Ethernet Protocol

  • Park, Hong-Seong;Jung, Myong-Soon;Kang, Weon-Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.118-118
    • /
    • 2000
  • This paper suggests the methodology to guarantee the rea1-time service over Ethernet and TCP/IP and to solve the problems such as re-transmission due to collision and platform-transparency and independence. This paper proposes a new mechanism called Real-time Ethernet protocol combined the centralized medium control mechanism with the token passing mechanism. The centralized medium control mechanism is used to get the token, the right to transmit the data, and the token passing mechanism is used to return the token to the token controller and to transmit data within the specified time interval. The proposed Real-Time Ethernet Protocol is based on Java and Java RMI(Remote Method Invocation). The presented protocol is believed to work enough in real-time applications considering latency occurred due to the Java RMI, which is less small than data transmission time.

  • PDF