• 제목/요약/키워드: Real-Time Holographic Interferometry

검색결과 19건 처리시간 0.027초

Hele-Shaw Cell 내부의 열유동 해석을 위한 홀로그래픽 간섭계와 2차원 PIV의 적용 (Application of Holographic Interferometry and 2-D PIV for HSC Convective Flow Diagnostics)

  • 김석;이상준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.682-687
    • /
    • 2003
  • The variations of temperature and velocity fields in a Hele-Shaw convection cell (HSC) were investigated using a holographic interferometry and 2-D PIV system with varying Rayleigh number. To measure quasisteady changes of temperature field, two different measurement methods of holographic interferometry; double-exposure method and real-time method, were employed. In the double-exposure method, unwanted waves can be eliminated effectively using digital image processing technique and the reconstruction images are clear, but transient flow structure cannot be reconstructed clearly. On the other hand, transient convective flow can be reconstructed well using the real-time method. However, the fringe patterns reconstructed by the real-time method contain more noises, compared with the double-exposure method. Experimental results show a steady flow pattern at low Rayleigh numbers and a time-dependent periodic flow structure at high Rayleigh numbers. The periodic flow pattern at high Rayleigh numbers obtained by the real-time holographic interferometer method is in a good agreement with the PIV results.

  • PDF

홀로그래픽 간섭계와 PIV를 이용한 Hele-Shaw Convection Cell 내부 열유동 해석 (Measurement of Thermal Flow in a Hele-Shaw Convection Cell Using Holographic Interferometry and PIV Technique)

  • 김석;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.35-38
    • /
    • 2002
  • Variations of temperature and velocity fields in a Hele-Shaw Convection Cell (HSC) were measured using a holographic interferometry and PIV technique with varying Rayleigh number. Experimental results show a steady flow pattern at low Rayleigh numbers and a time-dependent periodic flow at high Rayleigh numbers. Two different measurement methods of holographic interferometry, double-exposure method and real-time method, were employed to measure the temperature field variations of HSC convective flow. In the double-exposure method, unwanted waves can be eliminated and reconstruction images are clear, but transient flow structure cannot be observed clearly. On the other hand, transient flow can be observed and reconstructed well using the real-time method. PIV results show that flow inside the HSC is periodic and the oscillating state is well matched with the temperature field results. The holographic interferometry and PIV techniques employed in this study are useful for analyzing the unsteady convective thermal fluid flows.

  • PDF

홀로그래픽 간섭계를 이용한 Hele-Shaw Convection Cell 내부 온도장 측정 (Temperature Field Measurements of Hele-Shaw Convection Cell Using a Holographic Interferometry)

  • 김석;이상준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.530-535
    • /
    • 2001
  • Variations of temperature field in a Hele-Shaw convection cell (HSC) were measured using a holographic interferometry with varying Rayleigh number. Experimental results show a steady flow pattern at low Rayleigh numbers and a time-dependent periodic flow at high Rayleigh numbers. Especially, the period of oscillation at $Ra = 6.35{\times}10^6$ was 62 seconds. Two different measurement methods of holographic interferometry, double-exposure method and real-time method, were employed to measure the temperature field variations of HSC convective flow. In the double-exposure method, unwanted waves can be eliminated and reconstruction images are clear, but transient flow structure cannot be observed clearly. On the other hand, transient flow can be observed and reconstructed well using the real-time method. However, the fringe patterns reconstructed by the real-time method contain more noise, compared with the double-exposure method. The two holographic interferometer techniques employed complementary in this study were proved to be useful for analyzing the temperature field variations of unsteady thermal fluid flows.

  • PDF

디지털 홀로그래픽 간섭계와 PIV를 이용한 Hele-Shaw Cell 내부 열유동 해석 (Diagnosis of HSC Convective Flow Using a Digital Holographic Interferometry and PIV System)

  • 김석;이상준
    • 대한기계학회논문집B
    • /
    • 제28권4호
    • /
    • pp.493-499
    • /
    • 2004
  • Variations of temperature and velocity fields in a Hele-Shaw convection cell (HSC) were investigated using a holographic interferometry and 2-D PIV system with varying Rayleigh number. To measure quasi-steady variation of temperature field, two different measurement methods of holographic interferometry, double-exposure method and real-time method, were employed. In the double-exposure method, unwanted waves were eliminated effectively using a digital image processing technique. The reconstructed images are clear, but transient flow cannot be reconstructed clearly. On the other hand, transient convective flow can be reconstructed well using the real-time method. However, the fringe patterns reconstructed by the real-time method contain more noises, compared with the double-exposure method. Experimental results show a steady flow pattern at low Rayleigh numbers and a time-dependent periodic flow structure at high Rayleigh numbers. The periodic flow pattern at high Rayleigh numbers obtained by the real-time holographic interferometer method is in a good agreement with the PIV results.

홀로그래픽 간섭계를 이용한 Hele-Shaw Convection Cell 내부 온도장 측정 (Temperature Field Measurements of Hele-Shaw Convection Cell Using a Holographic Interferometry)

  • 김석;이상준
    • 대한기계학회논문집B
    • /
    • 제25권11호
    • /
    • pp.1624-1631
    • /
    • 2001
  • Variations of temperature field in a Hele-Shaw convection cell (HSC) were measured using a holographic interferometry with varying Rayleigh number. Experimental results show a steady flow pattern at low Rayleigh numbers and a time-dependent periodic flow at high Rayleigh numbers. Especially, the period of oscillation at Ra = 6.35 $\times$ 10$^{6}$ was 62 seconds. Two different measurement methods of holographic interferometry, double-exposure method and real-time method, were employed to measure the temperature field variations of HSC convective flow. In the double-exposure method, unwanted waves can be eliminated and reconstruction images are clear, but transient flow structure cannot be observed clearly. On the other hand, transient flow can be observed and reconstructed well using the real-time method. However, the fringe patterns reconstructed by the real-time method contain more noise, compared with the double-exposure method. The two holographic interferometer techniques employed complementary in this study were proved to be useful fur analyzing the temperature field variations of unsteady thermal fluid flows.

실시간 홀로그래픽 간섭법을 이용한 유체의 가시화 (Visualization and Measurement of Fluids with Real-time Holographic Interferometry)

  • 엄철;강영준;김동우;유원재;안중근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.539-544
    • /
    • 2001
  • The holographic measurement techniques can be applied to various industrial fields such as automobile, airplane, construction, electronics, medical, mechanics and physics. The visualization of fluids is very important in aerodynamics, heat transfer and stress analysis. There are classically optical methods such as shadowgraph, schlieren method, and Mach-Zehnder interferometry for visualizing the fluid flow phenomena. But, it is difficult to understand the continuous state of fluids well in those methods. In this study, the real-time holographic interferometer with high-speed camera is applied to the flow visualization. In addition, collimated laser beam and rotating wedge are used for recording and formation of carrier fringes, respectively.

  • PDF

홀로그래피 간섭계를 이용한 복합적층판의 결함측정 (Nondestructive Inspection Method of Composite Laminated Plates by Holographic Interferometry)

  • 김석중;김재형;박현철
    • 대한기계학회논문집
    • /
    • 제18권12호
    • /
    • pp.3202-3218
    • /
    • 1994
  • Mode shapes and natural frequencies of vibrating laminated composite plates are taken using real-time and time-average holographic interferometry. Debonds and delamination in the laminated plates are measured nondestructively. During holographic testing of composite plates, it has been found that the conditions for the local resonance in debonds are strongly dependent on the frequency of excitation. A membrane resonance model was proposed to describe this behavior. Relations between characteristic length according to the size, shape of debonds and membrane resonance frequency are presented. Several experiments were performed to verify the membrane resonance model. The agreements between the predicted excitation frequency and the observed resonance frequency are good. The experimental results show that higher stresses and strains due to local resonance lead to the debond detection.

위상변이법과 디지탈 영상처리를 이용한 홀로그래피 간섭무늬의 정량적 해석 (Quantitative Interpretation of Holographic Fringe by Using Phase Shifting Method and Digital Image Processing)

  • 고영욱;권영하;강대임;박승옥
    • 대한기계학회논문집
    • /
    • 제16권9호
    • /
    • pp.1728-1735
    • /
    • 1992
  • 본 연구에서는 실시간 홀로그래피 간섭계(real time holographic interfero- metry ststem)를 구성하고 위상변이법과 디지탈 영상처리를 이용하여 물체 변형을 실 시간으로 자동 측정이 가능하도록 하였다. 한편 광학계 구성과 대상물체의 상태에 따른 오차 요인을 해석하기 위해서 외팔보를 대상물체로 하여 측정된 변형값과 이론값 을 비교하였다. 응용예로써는 터빈 블레이드(turbine blade)에 굽힘력이 가해질때 나타나는 미소변형을 측정하였다.

Anodization of Aluminium Samples in Boric Acid Solutions by Optical Interferometry Techniques

  • Habib, K.
    • Corrosion Science and Technology
    • /
    • 제4권6호
    • /
    • pp.217-221
    • /
    • 2005
  • In the present investigation, holographic interferometry was utilized for the first time to monitor in situ the thickness of the oxide film of aluminium samples during anodization processes in boric acid solutions. The anodization process (oxidation) of the aluminium samples was carried out by the technique of the electrochemical impedance spectroscopy(EIS), in different concentrations of boric acid (0.5-5.0% $H_3BO_3$) at room temperature. In the mean time, the real-time holographic interferometry was used to measure the thickness of anodized (oxide) film of the aluminium samples in solutions. Consequently, holographic interferometry is found very useful for surface finish industries especially for monitoring the early stage of anodization processes of metals, in which the thickness of the anodized film of the aluminium samples can be determined without any physical contact. In addition, measurements of electrochemical values such as the alternating current (A.C) impedance(Z), the double layer capacitance($C_{dl}$), and the polarization resistance(Rp) of anodized films of aluminium samples in boric acid solutions were made by the electrochemical impedance spectroscopy(EIS). Attempts to measure electrochemical values of Z, Cdl, and Rp were not possible by holographic interferometry in boric acid especially in low concentrations of the acid. This is because of the high rate of evolutions of interferometric fringes during the anodization process of the aluminium samples in boric acid, which made measurements of Z, Cdl, and Rp are difficult.

실시간 홀로그래픽 간섭법을 이용한 압력용기의 내부결함 측정법 (A Measurement Method of Internal Defects of Pressure Vessles by Using Real-Time Holographic Interferometry)

  • 문상준;강영준;백성훈;김철중
    • 대한기계학회논문집A
    • /
    • 제20권4호
    • /
    • pp.1233-1240
    • /
    • 1996
  • Conventional measurement methods using ultrasonic wave or x-ray, eddy current for non-destructive testing(NDT) in nuclear power plants and other industrial plants have been utilized as the method of contact with objects to be inspected. For this reason these methods require relatively much time and inspection area is limited by the location of probe or film. But holograpic interferometry which is a non-contact optical measurement method using a coherent light source has an advantage that quantative measurement can be performed at a time. In this paper a new method using realtime holographic interfreometry and image processing for detecting internal flaws of pressure vessels is presented.