• 제목/요약/키워드: Reagent

검색결과 1,409건 처리시간 0.027초

Selective Reduction of Organic Compounds with Al-Trifluoromethanesulfonyldiisobutylalane. Comparison of Its Reactivity with Al-Methanesulfonyldiisobutylalane

  • Cha, Jin-Soon
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권1호
    • /
    • pp.219-224
    • /
    • 2011
  • The new MPV type reagent, Al-trifluoromethanesulfonyldiisobutylalane ($DIBAO_3SCF_3$), has been prepared and its reducing characteristics in the reduction of selected organic compounds containing representative functional groups have been examined, and compared its reactivity with that of Al-methanesulfonyldiisobutylalane ($DIBAO_3SCH_3$) in order to understand the fluorine-substituent effect on its reactivity. In general, the reactivity of $DIBAO_3SCF_3$ appears to be much higher than that of $DIBAO_3SCH_3$, apparently due to the acidity increase by the electron-withdrawing fluorine-substituent. The reagent reduced aldehydes and ketones readily, but showed a perfect selectivity in the reduction of $\alpha,\beta$-unsaturated aldehydes and ketones to produce the corresponding allylic alcohols in an absolutely 100% purity. In addition, the reagent achieved the regioselective cleavage of phenyl- or/and alkyl-substituted epoxides to the less substituted alcohols in a perfect regioselectivity. Moreover, the reagent also showed an high stereoselectivity in the reduction of substituted cycloalkanones to produce the thermodynamically more stable alcohol epimers exclusively.

Selective Reduction by Lithium Bis-or Tris(dialkylamino)-aluminum Hydrides. II. Reaction of Lithium Tris(dibutylamino)-aluminum Hydride with Selected Organic Compounds Containing Representative Functional Groups

  • Cha, Jin-Soon;Lee, Sung-Eun;Lee, Heung-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • 제12권6호
    • /
    • pp.644-649
    • /
    • 1991
  • The approximate rates and stoichiometry of the reaction of excess lithium tris(dibutylamino)aluminum hydride (LT-DBA) with selected organic compounds containing representative functional groups under standardized conditions (tetrahydrofuran, $0^{\circ}C$) were studied in order to characterize the reducing characteristics of the reagent for selective reductions. The reducing ability of LTDBA was also compared with those of the parent lithium aluminum hydride and the alkoxy derivatives. The reagent appears to be much milder than the parent reagent, but stronger than lithium tri-t-butoxyaluminohydride in reducing strength. LTDBA shows a unique reducing characteristics. Thus, the reagent reduces aldehydes, ketones, esters, acid chlorides, epoxides, and amides readily. In addition to that, ${\alpha},{\beta}$-unsaturated aldehyde is reduced to ${\alpha},{\beta}$-unsaturated alcohol. Quinones are reduced to the corresponding diols without evolution of hydrogen. Tertiary amides and aromatic nitriles are converted to aldehydes with a limiting amount of LTDBA. Finally, disulfides and sulfoxides are readily reduced to thiols and sulfides, respectively, without hydrogen evolution.

Chiral Derivatization of Hydroxycarboxylic Acids Using 2,4,6-Trichlorobenzoyl Chloride as a Highly Efficient Regioselective Esterification Reagent for Gas Chromatography-Mass Spectrometry

  • Park, Jeong Hyeok;Han, Sang Yun
    • Mass Spectrometry Letters
    • /
    • 제11권4호
    • /
    • pp.103-107
    • /
    • 2020
  • We report the application of 2,4,6-trichlorobenzoyl chloride (often referred to as Yamaguchi esterification reagent) for the selective derivatization of the carboxylic group for GC-MS with the sample preparation method optimized for GC-MS analysis. The reagent was shown to be capable of selectively turning the carboxylic group into a reaction center, i.e., anhydride, of which the further reaction was directed to a near complete formation of required esters by unique steric and electronic effects of the reagent. Using the developed method, the chiral separation of hydroxycarboxylic acids by GC-MS using non-chiral columns was successfully demonstrated.

RAGE-binding peptide-conjugated polyethylenimine as a dual-functional carrier: A RAGE-mediated gene carrier and an anti-angiogenic reagent

  • Lee, Dahee;Choi, Eunji;Lee, Jaewon;Oh, Jungju;Lee, Seonyeong;Lee, Minhyung
    • Journal of Industrial and Engineering Chemistry
    • /
    • 제67권
    • /
    • pp.284-292
    • /
    • 2018
  • Receptor for advanced glycation end-products (RAGE) is overexpressed in various cancer cells. In this study, a RAGE-binding peptide (RBP) was conjugated to polyethylenimine (25 kDa, PEI). RBP-conjugated PEI (PEI-RBP) was characterized as a dual-functional reagent, a RAGE-mediated gene carrier and an anti-angiogenic reagent. As a gene carrier, PEI-RBP had higher transfection efficiency to the C6 glioblastoma cells than PEI. As an anti-angiogenic reagent, the pEmpty/PEI-RBP complex reduced RAGE expression on the surface of the C6 glioblastoma cells. Also, the complex reduced the VEGF expression and tube formation of endothelial cells. Therefore, PEI-RBP may be useful for development of glioblastoma therapy.

당화혈색소 측정을 위한 Norudia® HbA1c 키트의 평가 (Evaluation of Norudia® HbA1c Kit for Glycohemoglobin Assay)

  • 홍승복;김은중
    • 대한임상검사과학회지
    • /
    • 제41권1호
    • /
    • pp.37-41
    • /
    • 2009
  • Measurement of hemoglobin A1c is used as an objective indicator of long-term blood glucose control in diabetic patients. We evaluated recently introduced Norudia$^{(R)}$ HbA1c (Daiichi Pure Chemical Co. Ltd, Tokyo, Japan) test reagent using enzyme method for HbA1c assay. Linearity, precision and correlation with VARIANT$^{TM}$ II Turbo HbA1c analyzer (BIO-RAD, Hercules, CA, USA) were evaluated. The reference range was determined from 201 healthy subjects. The Norudia$^{(R)}$ HbA1c test reagent was founded to be linear in a range of 5.6% to 14.0% ($r^2=0.9885$). The within-run and between-day precision were 0.954% and 1.03% for low level (HbA1c 5.24%), 0.67% and 1.28% for high level (HbA1c 9.01%), respectively. Comparison study between Norudia$^{(R)}$ HbA1c test reagent and VARIANT$^{TM}$ II Turbo showed good correlation with a slope of 1.0489. an intercept at -0.9717, and coefficient of correlation was 0.9907. The reference range of HbA1c obtained from this reagent was 4.07-5.50%. The Norudia$^{(R)}$ HbA1c test reagent showed good linearity, precision and correlation with HbA1c analyzer with HPLC method. In addition, the exclusive analyzer is not required for assay and then this kit may be useful for HbA1c assay in clinical laboratory.

  • PDF

이온교환체 전극을 이용한 베라파밀 정량 (Determination of Verapamil with ISE based on Ion Exchanger)

  • 이은엽;김동오;장승현;허문회;안문규
    • 약학회지
    • /
    • 제40권2호
    • /
    • pp.135-140
    • /
    • 1996
  • Ion-selective poly(vinyl chloride)(PVC) membrane electrodes for the determination of the calcium antagonist verapamil and its pharmaceutical preparations were described. Verapam il-superchrome garnet Y(SGY), lumogallion(LG), acid red 97(AR97), Dragendorff(DD) and Meyer reagent ion pairs were inverstigated as an electroactive compound for membrane electrode. Stable potentiometric response was obtained with azo dye at pH 6.5-4.0 and with DD, and Meyer reagent at pH 6.5-3.0. The best plasticizer was 49w/w% 2-nitrophenyl octyl ether for azo dye, and 65.3w/w% tri(n-butyl) citrate for DD and Meyer reagent. Potentiometric response slopes of optimized membrane electrodes based on SGY, LG, AR97, DD, and Meyer complex for verapamil were 52.49, 54.88, 50.81, 54.13 and 49.31 mV/dec., respectively. Lower limits of linear range were $1.0{\times}10^6M$ for SGY, LG, and AR97, while those for DD and Meyer reagent were $4{\times}10^{-6}M$. Detection limits for all these electrodes were $1{\times}10^{-5}M,\;4{\times}10^{-6}M,\;1.8{\times}10^{-6}M,\;8{\times}10^{-7}M,\;and\;1{\times}10^{-6}M$ with relative standard deviation of 2.56, 3.6, 3.96, 2.56, 3.20%, respectively.

  • PDF

물에서의 분원성대장균군 검사를 위한 최적 배지 선정 (Modification of Medium to Examine Fecal Coliforms in Water)

  • 이은숙;고나윤;최병도;김복순
    • 한국물환경학회지
    • /
    • 제36권4호
    • /
    • pp.275-283
    • /
    • 2020
  • Fecal coliforms are indicator bacteria to evaluate fecal contamination and microbiological safety in environment water. To examine fecal coliforms by membrane filtration, 1% rosolic acid solution dissolved in sodium hydroxide(0.2 M) should be added to m-FC medium according to Korean standard method. To reduce the exposure of researchers to harmful chemicals and expenditure of unnecessary cost, we evaluated if the rosolic acid solution is required to detect fecal coliforms. For 113 samples collected from five intake sources of Seoul, 42 samples of six tributaries, and 11 samples of sewage, the number of fecal coliforms was compared in medium with or without the reagent. As a result, the number was higher in m-FC medium without the reagent, but there was not a statistically significant difference. In the water intake, m-FC medium without the reagent could be used to examine fecal coliforms except in July, August and in case of rainfall. When heterotrophic plate counts exceeded 1,000 CFU/filter, or during rainfall, there was an effect of background bacteria in two types of the medium. However, it was more appropriate to use m-FC medium with the reagent to suppress gram-positive bacteria that can grow on medium without the reagent. In the tributary and sewage samples, the effect of the background bacteria was low, allowing the use of medium without the reagent regardless rainfall. Thus, it is necessary to present in standard method that the addition of rosolic acid solution in m-FC medium can be selected according to the characteristics of samples.

토양세척에 의한 오염토양의 중금속(Cu, Zn, Pb) 제거에 관한 연구 (A Study on Removal of Heavy Metals (Cu, Zn, and Pb) from Contaminated Soil by Soil Washing)

  • 김명진
    • 자원환경지질
    • /
    • 제46권6호
    • /
    • pp.509-520
    • /
    • 2013
  • 본 연구에서는 Cu, Zn, Pb 총함량이 각각 최고 3350, 1220, 2240 mg/kg에 이를 정도로 높은 오염토양을 토양세척에 의해 처리하여 해당 중금속을 제거하였다. 중금속 제거효율에 영향을 미치는 중요 인자인 세척제의 종류와 농도, 세척시간, 오염토양과 세척제의 혼합비, 교반속도 등의 최적조건을 도출하였다. 세 가지 중금속을 효과적으로 제거하는 최적 세척제는 50 mM 염산, 세척시간은 30분, 오염토양과 세척제의 혼합비는 1:30 (g/mL)이었으며, 교반속도는 중금속 제거효율에 영향을 미치지 않았다. 세척제인 염산을 재사용하면 중금속 제거효율이 감소했고, 연속적으로 재사용하면 중금속이 토양에 재흡착되었다.