• 제목/요약/키워드: Reactor Parameter

검색결과 296건 처리시간 0.032초

Dynamic characteristics of a CSTR with MMA polymerization

  • Ahn, Jong-Pil;Rhee, Hyun-Ku
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.100-105
    • /
    • 1992
  • A mathematical model is developed for a CSTR in which free radical solution polymerization of methyl methacrylate(MMA) takes place. It turns out that five ordinary differential equations are to be treated simultaneously in order to predict the reactor performance. Although the reaction proceeds under the conditions of relatively low temperature and pressure, the system shows very complex bifurcation features due to the diffusion limitation (gel effect) and the temperature dependence of the kinetic parameters and physical properties. The effects of various system parameters on the reactor performance as well as on the polymer properties are investigated by using the bifurcation analysis. The application of the singularity theory enables us to divide the parameter space into several different regions, in each of which the system takes a unique steady state structure. Under certain circumstances, complex dynamic features such as HB points and limit cycles are observed and these should be taken into consideration in the reactor design.

  • PDF

다중공진 영전류 스위칭을 이용한 고주파 유도가열용 인버터 (High Frequency Inverter for Induction Heating with Multi-Resonant Zero Current Switching)

  • 라병훈;서기영;이현우;김광태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.38-40
    • /
    • 2002
  • In the case of conventional high frequency inverter, with damage of switch by surge voltage when switch gets into compulsion extinction by load accident and so on because reactor is connected by series to switch, or there was problem of conduction loss by reactor's resistivity component, Also, it has controversial point of that can not ignore conduction loss of switch in complete work kind action of soft switching. In this paper, as high frequency induction heating power supply, we propose half bridge type multi resonance soft switching high frequency inverter topology that can realize high amplitude operation of load current with controlling switch current by multiplex resonance, mitigating surge voltage when switch gets into compulsion extinction and to be complete operation of zero current switching by opposit parallel connected reactor to inverter switch. and do circuit analysis for choice of most suitable circuit parameter of circuit

  • PDF

Reactivity feedback effect on loss of flow accident in PWR

  • Foad, Basma;Abdel-Latif, Salwa H.;Takeda, Toshikazu
    • Nuclear Engineering and Technology
    • /
    • 제50권8호
    • /
    • pp.1277-1288
    • /
    • 2018
  • In this work, the reactor kinetics capability is used to compute the design safety parameters in a PWR due to complete loss of coolant flow during protected and unprotected accidents. A thermal-hydraulic code coupled with a point reactor kinetic model are used for these calculations; where kinetics parameters have been developed from the neutronic SRAC code to provide inputs to RELAP5-3D code to calculate parameters related to safety and guarantee that they meet the regulatory requirements. In RELAP5-3D the reactivity feedback is computed by both separable and tabular models. The results show the importance of the reactivity feedback on calculating the power which is the key parameter that controls the clad and fuel temperatures to maintain them below their melting point and therefore prevent core melt. In addition, extending modeling capability from separable to tabular model has nonremarkable influence on calculated safety parameters.

가중유출수질지표를 이용한 활성오니공정모델의 민감도 분석과 매개변수 보정 (Sensitivity Analysis and Parameter Estimation of Activated Sludge Model Using Weighted Effluent Quality Index)

  • 이원영;김민한;김영황;이인범;유창규
    • 제어로봇시스템학회논문지
    • /
    • 제14권11호
    • /
    • pp.1174-1179
    • /
    • 2008
  • Many modeling and calibration methods have been developed to analyze and design the biological wastewater treatment process. For the systematic use of activated sludge model (ASM) in a real treatment process, a most important step in this usage is a calibration which can find a key parameter set of ASM, which depends on the microorganism communities and the process conditions of the plants. In this paper, a standardized calibration protocol of the ASM model is developed. First, a weighted effluent quality index(WEQI) is suggested far a calibration protocol. Second, the most sensitive parameter set is determined by a sensitive analysis based on WEQI and then a parameter optimization method are used for a systematic calibration of key parameters. The proposed method is applied to a calibration problems of the single carbon removal process. The results of the sensitivity analysis and parameter estimation based on a WEQI shows a quite reasonable parameter set and precisely estimated parameters, which can improve the quality and the efficiency of the modeling and the prediction of ASM model. Moreover, it can be used for a calibration scheme of other biological processes, such as sequence batch reactor, anaerobic digestion process with a dedicated methodology.

Development of Cleavage Fracture Toughness Locus Considering Constraint Effects

  • Chang, Yoon-Suk;Kim, Young-Jin;Ludwig Stumpfrock
    • Journal of Mechanical Science and Technology
    • /
    • 제18권12호
    • /
    • pp.2158-2173
    • /
    • 2004
  • In this paper, the higher order terms in the crack tip stress fields are investigated macroscopically for more realistic assessment of structural material behaviors. For reactor pressure vessel material of A533B ferritic steel, effects of crack size and temperature have been evaluated using 3-point SENB specimens through a series of finite element analyses, tensile tests and fracture toughness tests. The T-stress, Q-parameter and q-parameter as well as the K and J-integral are calculated and mutual relationships are investigated also. Based on the evaluation, it has proven that the effect of crack size from standard length (a/W=0.53) to shallow length (a/W=0.11) is remarkable whilst the effect of temperature from -20$^{\circ}C$ to -60$^{\circ}C$ is negligible. Finally, the cleavage fracture toughness loci as a function of the promising Q-parameter or q-parameter are developed using specific test results as well as finite element analysis results, which can be applicable for structural integrity evaluation considering constraint effects.

해석(解析)모델의 구조변수(構造變數) 변동(變動)이 동적응답에 미치는 영향(影響) (Effects of Structural Parameter Variations on Dynamic Responses)

  • 박형기;임부영
    • 대한토목학회논문집
    • /
    • 제13권3호
    • /
    • pp.59-67
    • /
    • 1993
  • 부분구조법(部分構造法)으로 프리스트레스드 콘크리트 원자로격납건물(原子爐格納建物)의 지진에 대한 확률위험도분석이나 내진 안전여유평가시 상부구조에 관한 입력자료(入力資料)가 되는 구조물(構造物)의 고유전동수와 구조물 상부에서의 최대가 속도값의 구조변수(構造變數)에 대한 변동성이 연구되었다. 본 연구는 먼저 구조모델의 고유진동수에 가장 큰 영향을 미치는 구조변수를 결정하기 위하여 각 구조변수(構造變數)의 상대적(相對的) 민감도(敏感度)를 분석(分析)하였고, 각 변수의 결정에 포함될 수 있는 불확실성(不確實性)의 정도를 고려하여 Monte Carlo 수치모형실험을 수행하였다. 최대 가속도값의 변화는 직접적분(直接積分)에 의한 시간이력곡선법으로 분석되었다. 연구결과로 첫번째모드의 고유 진동수와 건물 정상부의 최대가속도값은 각 변수중 탄생계수의 영향을 가장 크게 받으며, 결정론적 방법으로 구한 값과 비교할 때 확률론적 방법으로 구한 값(평균+표준편차)은 (+)12% 정도 변함을 알 수 있다. 또한 휨강성의 불확실성을 고려하면 동적응답은 (-)4%~(+)14% 정도 달라진다.

  • PDF

유동핵연료원자로를 위한 이차원 동특성 코드 AMBIKIN2D 개발 및 검증 (Development and Verification of AMBIKIN2D, A Two Dimensional Kinetics Code for Fluid Fuel Reactors)

  • 이영준;오세기
    • 에너지공학
    • /
    • 제17권1호
    • /
    • pp.23-30
    • /
    • 2008
  • 용융염 원자로는 고체핵연료를 사용하는 고전 원자로와는 달리 유동성을 갖는 액체핵연료를 장전하여 운전한다. 기존 동특성 코드는 핵연료의 유동으로 인한 동적 노물리 특성 영향을 고려하지 않기 때문에 용융염 원자로의 동특성 및 안전해석에 사용할 경우 신뢰성을 보장할 수 없다. 지금까지는 핵연료의 유동을 고려한 1점 동특성방정식을 이용하여 제한적으로 시스템안정성분석을 수행해 왔으나 이 경우 상세한 노심구조에서의 핵연료 및 중성자 거동에 대한 공간 종속성을 평가할 수 없다. 그러므로 핵연료의 유동 특성이 고려된 다차원 동특성 모델을 해석할 수 있는 컴퓨터 코드 개발이 필요하다. 본 논문은 용융염 원자로의 공간종속 중성자 동특성 해석을 위한 2군, 2차원 코드인 AMBIKIN2D의 개발 및 이에 수반하는 검증연구의 일환으로서 MSRE의 안정성실증실험을 모사하였다. 또한 비교 대상으로는 ORNL에서 개발한 Lumped parameter 방법을 사용한 일점 동특성 방정식에 의한 계산 결과를 포함하여 AMBIKIN2D의 정확성을 확인하였다.