• 제목/요약/키워드: Reactive Power Compensation

검색결과 297건 처리시간 0.021초

Comparison and Study of Active and Hybrid Power Filters for Compensation of Grid Harmonics

  • Gutierrez, Bryan;Kwak, Sang-Shin
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1541-1550
    • /
    • 2016
  • This paper presents a theoretical analysis and comparisons of active power filter (APF) and hybrid power filter (HPF) systems, given terminal constraints of harmonic compensations in nonlinear loads. Despite numerous publications for the two types of filters, the features and differences between them have not been clearly explained. This paper presents a detailed analysis of the operations of a HPF inverter along with those of passive power filters (PPFs). It also includes their effects on the power factor at the grid. In addition, a theoretical analysis and a systematic comparison between the APF and HPF systems are addressed based on system parameters such as the source voltage, output power, reactive component size, and power factor at the grid terminals. The converter kVA ratings and dc-link voltage requirements for both topologies are considered in the presented comparisons

직접 보상전압 추출기법을 이용하여 고조파전류와 무효전력을 보상하는 3상 4선식 직렬 형 능동전력필터의 제어법 (Three-phase Four-wire Series Active Power Filter Control Strategy for The Compensation of Harmonics and Reactive Power Based-on Direct Compensating Voltage Extraction Method)

  • 김진선;김영석
    • 전력전자학회논문지
    • /
    • 제9권3호
    • /
    • pp.213-221
    • /
    • 2004
  • 최근에, 평활용 직류 커패시터가 설치된 다이오드 정류기가 가전제품 및 교류 운전 장치와 같은 전자 장치에 점점 많이 사용되고 있고, 이러한 부하에 의해서 발생하는 고조파 문제가 점차 중요한 문제로 부각되고 있다. 또한, 3상 4선식 전력 시스템은 상업용 빌딩이나 제조 플랜트 등에 전력을 공급하는 방법으로 많이 사용되고 있는데 이러한 시스템에서는 중성선에 과도한 전류가 흐르게 되고, 중성선 전류는 기본적으로 3고조파 성분으로 중성선 도체 사이즈 선정의 실패나 중성점의 전위를 상승시키거나 변압기의 과열 현상 등을 유발할 수 있다. 이러한 관점에서 본 논문에서는 직접 보상전압 추출기법으로 동작하는 직렬 형 능동 필터를 제안하며, 성능함수 알고리즘의 장점은 게인을 곱하지 않고 보상 전압을 직접 구함으로써, 어떠한 다른 알고리즘보다 보상 전압 계산 방법이 간단하다. 제안된 알고리즘의 타당성을 증명하기 위하여 프로토타입 능동 필터를 제작하여 실험을 수행하였다.

전력보상설비의 상호 협조제어에 따른 운영여유용량의 확보 (Securing Operation Margin Capacity as Coordination Control among the Power Compensation Equipments)

  • 이상덕;백영식
    • 전기학회논문지
    • /
    • 제59권6호
    • /
    • pp.1011-1016
    • /
    • 2010
  • It is an important issue to electric power system operations that it can reliably supply large-capacity power to consumption area as due to increasing power demand growth. For this purpose, The FACTS equipment based on Power IT technology with the existing mechanical compensators has been applied to power system. Therefore we suggest on this paper that a plan for coordination control of multiple power compensation equipment in order to increase the utilization of each facility and secure operation margin capacity. As the result of simulation, it is possible to cope actively with a suddenly changed power system. This helps greatly for the voltage stability and supply reliability in a suddenly changed power system.

전원 불평형과 역률을 보상하는 직렬형 능동전력필터 (Series Active Power Filters for Source Voltage Unbalance Compensation and Power Factor Correction)

  • 장정익;이동춘;석줄기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.498-500
    • /
    • 2005
  • This paper presents a unified control scheme for series-type active power filters combined with shunt passive filters for the source voltage unbalance compensation and the power factor correction simultaneously. The power factor correction is achieved by controlling the amplitude of reactive power current in a series filter as zero in a synchronously rotating reference frame. The proposed algorithm successfully compensates the source voltage unbalance and the power factor. The validity of the proposed scheme has been verified by simulation for a 3-kVA hybrid active power filter system.

  • PDF

Key Application Technologies of High Efficiency Power Quality Control Systems

  • Liu, Ding-Guo;Shuai, Zhi-Kang;Tu, Chun-Ming;Cheng, Ying;Luo, An
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.458-468
    • /
    • 2013
  • Large capacity reactive power compensation and harmonic control in the low-voltage grid of an enterprise, are important technical means to improve power quality and reduce power loss. In this paper, the principle of an efficient power quality controller is analyzed. Then, key application technologies of the HPQC which would influence the performances of the HPQC are studied. Based on an analysis of the harmonic shunt problem, a frequency dividing control strategy of the HPQC continuous subsystem is proposed. A parameter design method of the HPQC discrete subsystem and its installation method are also proposed to ensure the system compensation effect. HPQC systems have been designed for a copper foil plant. The effectiveness of this paper has been verified by the simulation and application results.

Accurate Power Sharing in Proportion for Parallel Connected Inverters by Reconstructing Inverter Output Impedance

  • Huang, Shengli;Luo, Jianguo
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1751-1759
    • /
    • 2018
  • This paper presents parallel-connected inverters to achieve accurate proportional power sharing. Due to line impedance mismatch, reactive power cannot be distributed proportionally when using the conventional $P-{\omega}$ and $\mathcal{Q}-E$ droop. In order to realize reactive proportional power sharing, the ratio of the droop coefficients should be inversely proportional to their power-sharing ratios. Meanwhile, the ratio of the line impedance should be inversely proportional to the desired power-sharing ratio, which is very difficult to be met in practice. In order to deal with this issue, a practical control strategy is presented. By measuring the PCC voltage and using the virtual impedance, the output impedance of individual inverters is reconstructed to counteract the line impedance effect. In order to guarantee system stability, a low pass filter is designed to suppress the bandwidth of the line compensation. Finally, the simulation and experimental results are given to verify the effectiveness of the proposed control strategy.

능동전력필터의 간단한 순시전력이론과 수정된 보상성능 평가법 (A Simple Instantaneous Power Theory and Modified Compensation Performance Evaluation of Active Power Filters)

  • 정영국;유광호;김영철;양승학;김우용;임영철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2549-2552
    • /
    • 1999
  • The fictitious power theory in time domain is very easy to understand, but power analyzing time of active power is increased, because power is analyzed using signal techniques based on the correlation between voltage and current waveforms. Also, conventional methods in time/frequency domain to evaluate the compensation performance of active power filters are not provided easy solutions. So, the authors have previously proposed 3-D current coordinates which is composed into active component, fundamental reactive component and distorted component of nonlinear loads current. This method has excellent performance, but can not evaluate the characteristics of nonlinear load current whether inductive or capacitive. Therefore, To overcome problems mentioned previously, this paper deals with the simple instantaneous power theory and the modified 3-D current coordinates for evaluating the compensation performance of active power filters. To confirm the validity, active power filters simulator is developed using C-language. From the simulation, results are discussed their utility.

  • PDF

다단자망 알고리즘을 이용한 급전시스템의 무효전력 보상 모델링 및 시뮬레이션 (Modeling and Simulation Reactive Power Compensator using Multi-port Network Algorithm in Electrified Railway)

  • 김주락
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.883-887
    • /
    • 2016
  • The power supply system in Korean electrified railway has adopted AT feeding. If a fault occurs in some substation for any reason, the vicinity substation must feed electric power on the outage substation through catenary. So, the feeding distance grows twice of the normal state at extended feeding condition. If substation's feeding distance is longer than normal condition, the catenary impedance and train to supply electric power from the substation. Therefore, the severe voltage drop can occur and power supply shall be not allowed. This paper presents the model of compensator against voltage drop using multi-port network algorithm. Whole traction power supply system can be analyzed with this model. Computer simulation including this model is performed based on real train schedule and increased schedule in case studies.

전원측 무효전력 보상기능을 갖는 계통연계형 태양광 발전 시스템의 해석 및 설계 (Analysis and Design of Utility Interactive Photovoltaic System with Source Side VAR Compensation)

  • 이상용;고재석;한찬영;이정락;최규하;목형수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.591-594
    • /
    • 1999
  • The application field of photovoltaic system has been increased widely. In the application of photovoltaic system, the utility interactive photovoltaic system(UIPVS) has benefits of not only the home energy saving in domestic system but also reduction of peak power which threaten the capacity of power plant equipment when the maximum power consumption is occurred in daytime. This paper represents the effect of the nonlinear AC load which connected to the UIPVS with parallel connection and introduces the active power filtering(APF) techniques to the UIPVS for the reactive power compensation. The enhancement of source side power quality using APF algorithm is verified using simulation.

  • PDF

3상 4선식 전력계통에서 전압제어 방식의 역률보상시스템 (Power Factor Compensation System based on Voltage-controlled Method for 3-phase 4-wire Power System)

  • 박철우;이현우;박영균;정상현
    • 전자공학회논문지
    • /
    • 제54권8호
    • /
    • pp.107-114
    • /
    • 2017
  • 본 논문에서는 3상 4선식 전력계통에서 새로운 전압제어 방식의 역률보상시스템을 제안한다. 제안하는 전압제어 방식의 역률보상시스템은 슬라이닥을 이용하여 가변되는 출력전압을 커패시터에 인가하는 것으로 보상에 필요한 무효전력을 생성한다. 기존의 커패시터 뱅크 방법을 이용하는 역률보상시스템은 선택 가능한 커패시터 용량이 한정되어 있어 부하 상황에 따라 역률보상 오차가 발생하지만, 제안 시스템은 변화하는 부하를 추종하여 오차 없이 역률을 100%까지 보상할 수 있다. 본 논문에서는 3상 4선식 전력계통에서 전압제어 방식의 역률보상시스템과 제어 알고리즘을 개발하였고 모의실험과 실험을 통해 성능을 확인한다. 제안 시스템을 수용가에 설치할 경우 역률 개선을 통한 전기료 감소, 선로손실 감소, 부하 용량 증대 효과가 기대된다. 특히 발전 사업가 측에서는 역률 보상 성능의 향상으로 송전 여유 용량 확보와 발전량 절감이 가능하다.