• Title/Summary/Keyword: Reaction monitoring

Search Result 585, Processing Time 0.032 seconds

QUENCHING OF TYPE II PHOTOSENSITIZER IN THEIR TRIPLET STATES BY $\alpha$-TOCOPHEROL VIA AN ELECTRON TRANSFER REACTION

  • Boo, Yong-Chool;Lee, Keum-Pyo;Jung, Jin
    • Journal of Photoscience
    • /
    • v.5 no.3
    • /
    • pp.125-129
    • /
    • 1998
  • Occurrence of an electron (or H atom equivalent to one electron plus H+) transfer from $\alpha$- tocopherol $\alpha$(TOH) to a number of photosensitizers in theri triplet states were investigated by monitoring the ESR signal of $\alpha$-chromaoxyl radical ($\alpha$(TO.) in ethanolic solutions of $\alpha$TOH and the sensitizers under continuous illumination. Every sensitizer molecule examined, such as protocholorophyllide (Pchl), hematoporphyrin and rose bengal which are generally regarded as efficient type II photosensitizers and thus have long-lived triplet states, was found to actively participate in an electro transfer reaction with $\alpha$TOH even under air-saturation conditions, generating $\alpha$TOH complex as an intermediate in a fashion of Michaelis-Menten type of reaction. For the reaction of $\alpha$TOH with triplet Pchl, the rate law was derived by applying the steady approximation for the binary complex, triplet Pchl-$\alpha$TOH , which turned out to be well consistent with the kinetic data.

  • PDF

The Surveillance of Adverse Drug Reaction(ADR) Reported (3차 병원에서 보고된 의약품 부작용 현황 조사와 약물 부작용 관리를 위한 약사의 인식도 조사)

  • Choi, Yun Hee;Sohn, Uy Dong
    • Korean Journal of Clinical Pharmacy
    • /
    • v.13 no.2
    • /
    • pp.72-81
    • /
    • 2003
  • Adverse drug reaction (ADR) may increase hospital admission, morbidity and mortality and adding extra cost to healthcare expenditures. AIMS: This study was performed to identify the types of ADR being reported in a tertiary hospital, and to find out the ways to improve current ADR monitoring system. To investigate the attitudes of hospital pharmacists towards, and their understanding of ADR reporting. METHODS: Of 117 reports submitted to the pharmacy department during 3 months survey period, A questionnaire survey of 75 randomly selected hospital pharmacists was conducted. RESULT: Of the report was from patients aged between 60 and 70. The medical department with the high frequency in ADR reporting was Internal Medicines $(60\%)$. The most common ADR manifestations were gastrointestinal complaints $(47.8\%)\;and\;80\%$ of the reported cases were mild in their severity. The most common drugs suspected of causing ADR were CNS drugs which accounted for $38.4\%.\;55.5\%$ of respondent were aware of the need to education and information about ADR monitoring. The important reasons for unreporting ADR were unknown of how to report ADRs $(94.6\%)$. CONCLUSIONS: An ADR reporting system based on reporting by staff pharmacists has been effective increasing the number of reported reactions and pharmacist involvement in monitoring patients for ADRs. Pharmacists have the knowledge and responsibility to contribute to ADR reporting program. A great opportunity exists for pharmacists to contribute in this area of patient care.

  • PDF

Modified Principal Component Analysis for Real-Time Endpoint Detection of SiO2 Etching Using RF Plasma Impedance Monitoring

  • Jang, Hae-Gyu;Kim, Dae-Gyeong;Chae, Hui-Yeop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.32-32
    • /
    • 2011
  • Plasma etching is used in microelectronic processing for patterning of micro- and nano-scale devices. Commonly, optical emission spectroscopy (OES) is widely used for real-time endpoint detection for plasma etching. However, if the viewport for optical-emission monitoring becomes blurred by polymer film due to prolonged use of the etching system, optical-emission monitoring becomes impossible. In addition, when the exposed area ratio on the wafer is small, changes in the optical emission are so slight that it is almost impossible to detect the endpoint of etching. For this reason, as a simple method of detecting variations in plasma without contamination of the reaction chamber at low cost, a method of measuring plasma impedance is being examined. The object in this research is to investigate the suitability of using plasma impedance monitoring (PIM) with statistical approach for real-time endpoint detection of $SiO_2$ etching. The endpoint was determined by impedance signal variation from I-V monitor (VI probe). However, the signal variation at the endpoint is too weak to determine endpoint when $SiO_2$ film on Si wafer is etched by fluorocarbon plasma on inductive coupled plasma (ICP) etcher. Therefore, modified principal component analysis (mPCA) is applied to them for increasing sensitivity. For verifying this method, detected endpoint from impedance analysis is compared with optical emission spectroscopy (OES). From impedance data, we tried to analyze physical properties of plasma, and real-time endpoint detection can be achieved.

  • PDF

Structure Deformation Check with GPS and IMU (GPS와 IMU에 의한 구조물 변형 검색)

  • 김진수;박운용;장상규;안상준
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.113-117
    • /
    • 2004
  • Such social structures as bridges, buildings, dams and towers have been transformed by their own load or fundamental ground. They have been behaved by other external causes. These regular or irregular behaviors threaten to do their users safety. Therefore, to monitor the load of the structures or reaction shown by them could help to verify their behaviors. RTK GPS allows the use of a static base station and remote rover unit to allow for data collection within several seconds and in real time. It is useful for monitoring the behaviors of massive structures like bridges. In this Study, Among GPS methods, we used RTK GPS to analyze the precision of monitoring and then on the basis of it, we developed a monitoring system using RTK GPS when measured the behavior of main tower of a suspension bridge by using RTK GPS. Comparing a deviation between observation values, X axis was 1mm, Y axis was 1mm and Z axis 2.2mm. It turned out that it was possible to monitor and measure structures by RTK GPS.

  • PDF

Sensitivity Enhancement in Measurement of Hydrogen Gas Dissolved in Oil using Gas Collection Time (가스수집시간을 이용한 유중수소가스 측정감도 향상 연구)

  • Heo, Jong-Cheol;Sun, Jong-Ho;Kang, Dong-Sik;Jeong, Joo-Young;Park, Jung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.539-543
    • /
    • 2009
  • This paper describes the sensitivity enhancement in measurement of the hydrogen gas dissolved in oil using gas collection time. On-line gas measurement is a useful for continuous monitoring of power transformer. Recently many studies on hydrogen gas measurement, due to their simplicity and low price, have been done for transformer monitoring. In measurement of the hydrogen gas in oil, the suitable sensitivity and resolution in the desired ranges of the gas concentrations are needed for the reliable monitoring of power transformers. In this study, the sensor output trends were analyzed with the hydrogen gas collection time which means the time to collect the hydrogen gas before reaction of hydrogen gas sensor. It is indicated that the sensor outputs were increased with the increase of hydrogen gas collection times at the same hydrogen gas concentrations.

Monitoring of Leuconostoc Population During Sauerkraut Fermentation by Quantitative Real-Time Polymerase Chain Reaction

  • Kim, So-Young;Yoo, Ki-Seon;Kim, Yu-Jin;Seo, Eun-Young;Kim, Beom-Soo;Han, Nam-Soo
    • Journal of Microbiology and Biotechnology
    • /
    • v.21 no.10
    • /
    • pp.1069-1072
    • /
    • 2011
  • A real-time PCR assay method was established to monitor Leuconostoc spp. populations via specific amplification of the dextransucrase gene. Quantification of L. mesenteroides B-512F using both genomic DNA and cell suspensions yielded a log-linear correlation spanning approximately 5 log units. By using this method, monitoring changes of Leuconostoc spp. during sauerkraut fermentation was successfully accomplished with accuracy after inoculation of starter and sugars (sucrose and maltose).

Implementation of A Remote Fire Monitoring System Based on Bidirectional USN (양방향 USN기반 원격 화재 감시 시스템 구현)

  • Chung, Tae-Yun;Chung, Han-Su;Park, Lae-Jeong;Lee, Hyung-Bong;Moon, Jung-Ho
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.2 no.2
    • /
    • pp.107-115
    • /
    • 2007
  • In general, wireless sensor networks composed of many nodes which are located in ad. hoc environment and send the gathered data to sink node support only one way traffic. In those cases, it is not possible to send commands to nodes to react for exceptional events because the networks can not deliver downward data and the nodes run in pre-assigned fixed schedule. This paper expands the WSLP to bidirectional WSLP and implements a fire monitoring system on it, and shows the feasibility of bidirectional USN by demonstrating the usability of the process of reaction to a fire in the implemented fire monitoring system.

  • PDF

Development of Vibration Powered Generator for Vibration Monitoring (진동모니터링을 위한 자가진동발전기의 개발)

  • 김재민;최남섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.434-441
    • /
    • 2003
  • This paper presents a generator for stand-alone vibration monitoring system of bridge structure based on ambient vibration of bridge. In this paper, a novel electric power generator which has minimum effect of armature reaction is proposed. The related mechanical and electrical design equations are obtained and a pilot generator has been implemented. In addition, the charging system for extremely low generator current is discussed, and some improvements are identified for the system. This investigation reveals that diode characteristics of rectifier is dominant factor in the charging process. Finally, both the simulation, which uses real measurement data of the Namhae bridge as input of the pilot generator, and indoor test are carried out. The results showed the applicability and effectiveness of the stand-alone vibration powered generator.

  • PDF

Impaction of a continuous glucose monitoring sensor

  • Park, Kyong Chan;Choi, Hwan Jun
    • Archives of Plastic Surgery
    • /
    • v.48 no.4
    • /
    • pp.392-394
    • /
    • 2021
  • A 33-year-old man presented to the plastic surgery department for foreign body removal 1 month after the insertion of a continuous glucose monitoring (CGM) sensor (Dexcom G5) in the left upper arm. The patient had used the CGM system for 5 years, and the insertion was done in the usual manner. The entire sensor wire was visible on simple radiography and ultrasonography. In the operating room, and the sensor wire was identified in the intermuscular septum and removed. No foreign body reaction or inflammatory signs were found around the CGM, and the extracted wire measured 2.5 cm. Thus, it was assumed that the whole sensor wire was detached from the transmitter, not fractured. No remnant foreign body was observed on follow-up simple radiography.