• Title/Summary/Keyword: Reaction monitoring

Search Result 585, Processing Time 0.038 seconds

Clinical characteristics of adverse reaction to radiocontrast media in children - A single center experience (소아에서 방사선 조영제 유해반응의 임상적 특징)

  • Kim, Min Jung;Lee, Bo Ra;Choi, Young Hun;Kang, Dong Yoon;Kang, Hye-Ryun;Suh, Dong In
    • Allergy, Asthma & Respiratory Disease
    • /
    • v.6 no.6
    • /
    • pp.315-321
    • /
    • 2018
  • Purpose: Radiocontrast media are widely used in medical imaging to improve diagnostic accuracy. However, studies on the adverse reactions of radiocontrast media in children are limited. We aimed to describe the characteristics of adverse reactions to radiocontrast media among children who had a computed tomography scan or magnetic resonance imaging in a tertiary university hospital. Methods: We retrospectively collected data on adverse reactions to radiocontrast media by the reporting system of a tertiary university hospital. We selected data from children under the age of 19 from July 2011 to December 2017 and analyzed their characteristics. We focused mainly on the characteristics of the index case which is defined by the first adverse event of each subject. Results: During the period, a total of 88,050 radiocontrast media-enhanced imaging studies were performed and 184 cases of adverse reactions were reported. A total of 71 were identified as index cases. Forty-nine (69.0%) were male and the mean age was $12.7{\pm}3.2$ years. The incidence of radiocontrast media-related adverse reactions was 0.09% and severe reactions were 0.002%. The most common clinical feature was skin manifestations (54.9%), followed by gastrointestinal symptoms (40.8%) and neuropsychiatric symptoms (7.4%). Conclusion: Adverse reactions to radiocontrast media rarely occur in children and the incidence of severe reactions is low. Most reactions are mild and are related to the skin and gastrointestinal system. This report would provide good evidence for establishing a management strategy in children scheduled for imaging studies using radiocontrast media.

Development and Assessment of Specific and High Sensitivity Reverse Transcription Nested Polymerase Chain Reaction Method for the Detection of Aichivirus A Monitoring in Groundwater (지하수 중 Aichivirus A 모니터링을 위한 특이적 및 고감도 이중 역전사 중합효소연쇄반응 검출법 개발 및 평가)

  • Bae, Kyung Seon;Kim, Jin-Ho;Lee, Siwon;Lee, Jin-Young;You, Kyung-A
    • Korean Journal of Ecology and Environment
    • /
    • v.54 no.3
    • /
    • pp.190-198
    • /
    • 2021
  • Human Aichivirus (Aichivirus A; AiV-A) is a positive-sense single-strand RNA non-enveloped virus that has been detected worldwide in various water environments including sewage, river, surface, and ground over the past decade. To develop a method with excellent sensitivity and specificity for AiV-A diagnosis from water environments such as groundwater, a combination capable of reverse transcription (RT)-nested polymerase chain reaction (PCR) was developed based on existing reported and newly designed primers. A selective method was applied to evaluate domestic drinking groundwater samples. Thus, a procedure was devised to select and subsequently identify RT-nested PCR primer sets that can successfully detect and identify AiV-A from groundwater samples. The findings will contribute to developing a better monitoring system to detect AiV-A contamination in water environments such as groundwater.

A Simple and Efficient Method to Determine Montelukast in Rat Plasma Using Liquid-Liquid Extraction and Tandem Mass Spectrometry

  • Kim, Dong Yoon;Lee, Hyo Chun;Jang, Yong Jin;Kim, Jin Hee;Lee, Ha Ryeong;Kang, Myung Joo;Choi, Yong Seok
    • Mass Spectrometry Letters
    • /
    • v.11 no.4
    • /
    • pp.71-76
    • /
    • 2020
  • While montelukast (ML), a cysteinyl-leukotriene type 1 receptor (CysLT1) antagonist is widely used to treat symptoms of rhinitis or asthma, its formulations are mainly limited to solid preparation due to its instability. Recently, there have been attempts to develop various ML dosage forms, and this situation increases the demand of sensitive and creditable methods to determine ML in various samples such as plasma. Thus, here, a simple and efficient method to determine ML in rat plasma using liquid-liquid extraction (LLE) and multiple reaction monitoring was presented. The mixture of DCM:EtOAc (25:75, v/v), the optimized extract solvent for LLE was found to be effective to extract ML without hydrophilic salts and proteins from the sample with limited volume. Also, the use of zafirlukast, instead of expensive ML-d6, as the internal standard makes the present method economical. The developed method was successfully validated in terms of selectivity, matrix effects (-14.8--6.9%), linearity (r230.998 within 0.5-500 ng/mL), sensitivity (the limit of detection and the lower limit of quantitation, ≤0.5 ng/mL), accuracy (88.4-100.6%), precision (3.0-13.3%), and recovery (80.8-86.3%) by following the FDA guidelines. Finally, the applicability of the validated method to pharmacokinetics (PK) studies was confirmed by the successful determination of PK parameters through it following oral administration of Singulair® granule in rats. Therefore, the present method can contribute to the development of new ML formulations through its performance to determine ML in rat plasma efficiently and sensitively.

Development of Analytic Methods for Veterinary Drug Residue in Animal Products by Liquid Chromatography-Mass Spectrometry (축산물 중 잔류 성장보조제 분석을 위한 액체크로마토그라피-질량분석법 개발 및 적용)

  • Lee, Soo Hyun
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.2
    • /
    • pp.107-116
    • /
    • 2021
  • In this study, an analytical method was developed for estradiol-17��, testosterone, and progesterone, which are growth promoters as veterinary drug residues in animal food. The analytes were separated using liquid chromatography, and was injected into a mass spectrometer through the electrospray ionization(ESI) process and detected in multiple reaction monitoring(MRM) mode. As the method was validated by CODEX CAC/GL 71-2009 guideline, it met the acceptable. The analysis of beef, pork, and chicken distributed in Korea was conducted with an established method to confirm the applicability of the actual sample. It was confirmed that the developed method can be quickly and reliably in the analysis for the growth promoters identified in domestic distributed livestock products. Through subsequent research, a highly utilized analysis method will be completed if the number of growth promoters is expanded based on the method and the simultaneous analytical method is established by including all of it.

A Sensitive, Efficient, and Cost-Effective Method to Determine Rotigotine in Rat Plasma Using Liquid-Liquid Extraction (LLE) and LC-MRM

  • Kim, Ji Seong;Jang, Yong Jin;Kim, Jin Hee;Kim, Jin Hwan;Seo, Jae Hee;Park, Il-Ho;Kang, Myung Joo;Choi, Yong Seok
    • Mass Spectrometry Letters
    • /
    • v.13 no.4
    • /
    • pp.146-151
    • /
    • 2022
  • Rotigotine (RTG) is a non-ergot dopamine agonist used to manage the early stage of Parkinson's disease (PD) as transdermal patch. However, the poor medication compliance of PD patients and skin issues related with repeated applications of RTG patches lead to the search for alternative formulations and it also requires appropriate analytical methods for their in vivo evaluation. Thus, here, a sensitive, efficient, and cost-effective method to determine RTG in rat plasma using liquid-liquid extraction (LLE) and multiple reaction monitoring was developed. The use of 20 µL of rat plasma for sample treatment, 8-OH-DPAT as the internal standard, and methyl tert-butyl ether as the LLE solvent in the present method gives it advantages over previous methods for the analysis of RTG in biological samples. The good analytical performance of the developed method was confirmed in specificity, linearity (the coefficient of determination ≥0.999 within 0.1-100 ng/mL), sensitivity (the lower limit of quantitation at 0.1 ng/mL), accuracy (81.00-115.05%), precision (≤10.75%), and recovery (81.00-104.48%) by following the FDA guidelines. Finally, the applicability test of the validated method to the in vivo evaluation of a RTG formulation showed that the present method is the only method which can be accurately applied to that longer than 24 hours, critical for the development of formulations with reduced dosing frequencies. Therefore, the present method could contribute to the development of new RTG formulations helpful to people suffering from PD.

Management of Adverse Reactions to Iodinated Contrast Media for Computed Tomography in Korean Referral Hospitals: A Survey Investigation

  • Seungchul Han;Soon Ho Yoon;Whal Lee;Young-Hun Choi;Dong Yoon Kang;Hye-Ryun Kang
    • Korean Journal of Radiology
    • /
    • v.20 no.1
    • /
    • pp.148-157
    • /
    • 2019
  • Objective: To evaluate the current status of managing adverse reactions to iodinated contrast media (ICM) for computed tomography in referral hospitals in South Korea compared with hospitals in other countries. Materials and Methods: This survey investigation involved 59 Korean and 15 overseas hospitals using guideline-based questionnaires consisting of 24 items in 7 main categories related to managing adverse reactions to ICM. Results: Informed written consent with risk factor evaluation was appropriately performed in most of the Korean hospitals. There was considerable variability in assessing renal function across the hospitals; serum creatinine level was used as a reference in 76.4% of Korean hospitals. The Korean hospitals preferred a more stringent approach to determining normal renal function (p = 0.01), withholding metformin (p = 0.01), and fasting before ICM exposure (p < 0.001) compared with overseas hospitals. All the Korean hospitals had an emergency protocol and in-hospital system for adverse reactions to ICM. The Korean (87.7%) and overseas hospitals (100%) were similarly equipped with epinephrine (p = 0.332), but only 38.6% of Korean hospitals were equipped with a bronchodilator (p = 0.004). For patients with a previous hypersensitivity reaction to ICM, 62.3% of Korean hospitals pre-medicated with anti-histamine and corticosteroid according to the severity of the previous reaction, and changed the culprit ICM in 52.8%, while skin test was performed in 17%. Conclusion: In general, Korean referral hospitals were well-prepared regarding informed consent, protocol, and an in-hospital system for managing adverse reactions to ICM. Nevertheless, there was considerable variability in details and management, thus requiring standardization by reflecting current guidelines.

Genetic Monitoring of Plant Growth Promoting Rhizobacterium (PGPR), Bacillus subtilis AH18 using Multiplex PCR in Field Soil (Multiplex PCR을 이용한 생물방제균 Bacillus subtilis AH18의 토양내 Genetic Monitoring)

  • Woo, Sang-Min;Lim, Jong-Hui;Jeong, Hee-Young;Kim, Sang-Dal
    • Microbiology and Biotechnology Letters
    • /
    • v.37 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • The genetic monitoring method was developed for the rapid detection of the PGPR and biocontrol agent, B. subtilis AH18 in red-pepper field soil by multiplex PCR using sid, aec and cel gene primers. The monitoring of B. subtilis AH18 in the soil was carried by amplified a 2,3-dihydro-2,3-dihydroxy benzoate dehydrogenase [EC: 1. 3. 1. 28]gene (sid - 794 bp : EF408238) which is a key enzyme of siderophore synthesis, an auxin efflux carrier gene (aec - 1,052 bp : EF408239) and a cellulase gene (cel - 1,582 bp : EF070194). The natural un sterilized soil was inoculated with B. subtilis AH18 to determine the sensitivity ($1.8\times10^5$ cfu/g) of multiplex PCR for the rapid dectection and then the strain was monitored successfully in rhizosphere or non-rhizosphere soil of red-pepper cultural soil. At 3 weeks after the treatment, density of the strain was monitored more abundantly in rhizosphere soil.

A Study on Evaluation of Modulus of Horizontal Subgrade Reaction through Field Test and Numerical Analysis (현장시험과 수치해석을 통한 수평지반반력계수 산정에 관한 연구)

  • Kang, Byungyun;Park, Minchul;Lee, Sihyung;Jang, Kisoo;Koo, Jagap;Park, Kyunghan
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.4
    • /
    • pp.5-15
    • /
    • 2016
  • For achieving stability and economic construction at a retaining wall construction site, quantitative parameters of soil properties with excavation steps coincides with the actual field site. The main parameters of retaining wall design such as deformation modulus and modulus of horizontal subgrade reaction are common with N value of standard penetration test. Therefore, this study is compared and analyzed about the mutual relationship which is SPT, PBT and PMT for overcoming inconsistency of the existing retaining wall design generalized. In addition, modulus of horizontal subgrade reaction and reduction factor with excavation steps are proposed through back analysis of elasto-plasticity and finite element method with actual field monitoring data. Finally, it is purpose that parameter errors are reduced for applying effective retaining wall design at a construction small and medium-sized.

ANALYSIS OF FLUIDIC BEAD CUBE EMBEDDED PORTABLE CMOS SENSING SYSTEM FOR IMMUNO REACTION MONITORING (유체소자가 집적화된 면역검사용 휴대용 CMOS 바이오칩의 분석)

  • Jeong, Yong-Won;Park, Se-Wan;Kim, Jin-Seok;Kim, Hyeon-Cheol;Chun, Kuk-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.755-758
    • /
    • 2005
  • This paper describes the novel immunoassay sensing system for a portable clinical diagnosis system. It consists of a bead cage reactor and a CMOS integrated biosensor. It showed the simple and easy antibody coating method on beads by flow-through avidin biotin complex technology in a microfluidic device. It showed just 90 nL sample consumption and good result for the application of alpha feto protein. The bead cage reactor has the role of the antibody coating, antigen binding and enzyme linking for the electrochemical sensing method. The CMOS biosensor consists of ISFET (ion selective field effect transistor) biosensor and temperature sensor for detecting pH that is the byproduct of enzyme reaction. The sensitivity is 8 $kHz/^{\circ}C$ in a temperature sensor and 33 mV/pH in a pH sensor. After filling the 15 um polystyrene beads in bead cage, antibody flowed and reacted to beads. Subsequently, the biotinylated antigen flowed and bound to the antibody and GOD (glucose oxidase)-avidin conjugate flowed and reacted to the biotin of the biotinylated antigen. After this reaction process, glucose solution flowed and reacted to the GOD on beads. The hydrogen was generated by glucose-GOD reaction. And it was detected by the pH sensor.

  • PDF

Kinetic Study on the Cationic Polymerization of Glycidyl Azide Monomer(GAM) by Real-Time In-suti IR (실시간 In-situ IR을 이용한 Glycidyl Azide Monomer(GAM)의 양이온중합 반응속도 연구)

  • Kim, Hyoung-Sug;Kim, Kwan-Yung;Kang, Shin-Choon;Noh, Si-Tae;Kim, Jin-Seuk;Yu, Jae-Chul;Choi, Keun-Bae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.228-235
    • /
    • 2009
  • We synthesized glycidyl azide monomer(GAM) as a monomer for polymerization of glycidy azide polymer(GAP) which is a promising energetic prepolymer for a plastic-bonded explosive. Using quantitative real-tim in-situ infrared(in-situ IR) spectroscopy, kinetic study on the cationic ring opening polymerization of GAM was carried out. The reaction rate was obtained from monitoring the change of ether C-O stretching band($1050cm^{-1}$) in series IR spectra. The reaction was in accordance with the first-order reaction law for each of reaction temperature at 100/1 mole ratio of [GAM]/[$BF_3*etherate$]. In the ring opening polymerization of GAM, with ratio of [GAM]/[$BF_3*etherate$] to equal 100/1 at various temperature, the activation parameters obtained from the evaluation of kinetic data were ${\Delta}H^*$=14.34kcal/mol, ${\Delta}S^*=-12.31cal/mol{\cdot}K$ and $E_a$=14.89kcal/mol.