• Title/Summary/Keyword: Re-176

Search Result 62, Processing Time 0.024 seconds

A Study on the Measurement of the Relative Nuclear Reaction Cross-Section of the natW(p,xn)176Re Reaction using 100 MeV Proton (100 MeV 양성자를 이용한 natW(p,xn)176Re 핵반응의 상대 핵반응단면적 측정에 대한 연구)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.257-263
    • /
    • 2021
  • This study derives the relative cross-section for the natW(p,xn)176Re nuclear reaction by measuring the gamma rays generated from the nuclear reaction with natural tungsten using a 100 MeV linear accelerator of the Korea Multi-purpose Accelerator Complex in the Korea Atomic Energy Research Institute. In general, research on isotopes with a short half-life always shows a tendency that the intensity of radioactivity decreases rapidly within a short period of time, making it very difficult to measure itself. In particular, 176Re is one of the relatively short radionuclides with a half-life of 5.3 minutes. In this study, 109.08 keV gamma rays generated from the 176Re isotope having such a short half-life were measured using a high-purity Ge detector(HPGe detector). The obtained relative measurements were the results in the 8 to 14 MeV proton energy domain published by Richard G. in 1967, and the TENDL-2019 value, which was the result of A. J. Koning in 2019, which evaluated the nuclear reaction cross-section by calculation based on this comparative analysis was performed. The results of this study are expected to be usefully applied to the design of nuclear fusion reactor which is known as future energy sources, elements ratio for the nuclear synthesis of astrophysics.

A Study on Measurement of Gamma-ray Spectrum for the Natural Tungsten nuclear reaction by using KOMAC proton Linear Accelerator (KOMAC 양성자 선형가속기를 이용한 천연 텅스텐 핵반응에 대한 감마선 스펙트럼 측정에 대한 연구)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.133-138
    • /
    • 2018
  • The measurement of gamma-ray spectrum of $^{nat}W(p,xn)$ reaction with natural tungsten were performed by using a high energy proton generated from a 100-MeV proton linear accelerator of the Korea Multi-purpose Accelerator Complex (KOMAC). Gamma rays generated by various nuclides generated through the nuclide were measured using a gamma-ray spectroscopy system composed of HPGe detector. A gamma-ray standard source was used for energy calibration and efficiency measurement of the detector. Analysis of the gamma rays observed in the measured spectra showed that the radionuclides produced were $^{167}Re$, $^{178}Re$, $^{179}Re$, $^{180}Re$, $^{181}Re$, $^{182}Re$, $^{184}Re$, $^{172}Ta$, $^{174}Ta$, $^{178}Ta$, $^{182}Ta$, $^{184}Ta$, $^{175}W$, $^{176}W$, $^{177}W$ and $^{179}W$. Nuclides were generated. The results of this study will be applied to nuclear fusion, astrophysics, and nuclear medicine applications in the future.

The Effect of Perceived Medical Services Quality by Outpatient on the Hospital Image, Satisfaction and Re-use Intention (외래환자가 지각한 의료 서비스의 질이 병원 이미지, 만족도 및 재이용 의도에 미치는 영향)

  • Cho, Yun-Hee;Park, Yeon-Suk
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.4
    • /
    • pp.516-529
    • /
    • 2018
  • The purpose of this study is to investigate the effect of perceived medical service quality by outpatient on hospital image, satisfaction, and re-use intention in a general hospital. A total of 176 questionnaires were administered to outpatients who presented to a S general hospital in Daejeon. The results of this study are as follows. First, medical service quality had significant effects on re-use intention, satisfaction, and hospital image. Second, the mediating effect of satisfaction on the relationship between medical service quality and re-use intention was not significant but the mediating effect of hospital image on the relationship was significant. Third, satisfaction and hospital image had significant effects on re-use intention. Consequently, this study verified the influence of perceived medical service quality by outpatient on hospital image, satisfaction, and re-use intention in a general hospital. Further, considering that hospital image, rather than satisfaction, mediates the relationship between perceived medical service quality and re-use intention, it suggests that much more general satisfaction is required in the marketing activities of hospitals.

The Relationships Between Patient's Perceived Quality of Healthcare Service and Intention to Re-visit (대상자가 인지한 의료서비스 질과 재이용 의도와의 관계)

  • Rho, Eun-Kyung;Oh, Suk-Hee
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.14 no.2
    • /
    • pp.176-181
    • /
    • 2008
  • Purpose: This study was performed to identify the relationship between patient's perceived quality of healthcare services and intention to re-visit. Method: The study subjects were 242 patients from three local clinics. The data were analyzed using SPSS PC+ 12.0 program for descriptive, Pearson's correlation coefficient, and multiple regression analysis. Result: Patients' perceived quality of healthcare services was measured 5.73$\pm$0.71 using the 7-point scale. The patients' perceived quality was moderately correlated with patient satisfaction (r=0.647, p<0.001) and intention to re-visit (r=0.604, p<0.001). Also, patient satisfaction was highly correlated with intention to re-visit (r=0.788, p<0.001). 3) the reliability factor of patients' perceived quality of healthcare services and patient satisfaction were found significant predictors of intention to re-visit. Conclusion: In conclusion, service quality evaluated by patients influenced on their intention of re-visit and especially, reliability was the most significantly influential variable.

  • PDF

Secure-ReXpis System with Internet Environment

  • Ahn, Kyeong-Rim
    • Proceedings of the CALSEC Conference
    • /
    • 2001.08a
    • /
    • pp.165-176
    • /
    • 2001
  • * Extension of EC(Electronic Commerce) * Standard of Message -EDI : UN/EDIFACT, ANSI X12, etc -XML : ebXML, CML, MathML, WIDL, etc * Various of Information -Business Transaction Data -Private Data : ID, Password, Personal Information -Charge Data : Accounts, Card, etc * Message Level Security(omitted)

  • PDF

Geometric Feature Recognition Directly from Scanned Points using Artificial Neural Networks (신경회로망을 이용한 측정 점으로부터 특징형상 인식)

  • 전용태;박세형
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.6
    • /
    • pp.176-184
    • /
    • 2000
  • Reverse engineering (RE) is a process to create computer aided design (CAD) models from the scanned data of an existing part acquired using 3D position scanners. This paper proposes a novel methodology of extracting geometric features directly from a set of 3D scanned points, which utilizes the concepts of feature-based technology and artificial neural networks (ANNs). The use of ANN has enabled the development of a flexible feature-based RE application that can be trained to deal with various features. The following four main tasks were mainly investigated and implemented: (1) Data reduction; (2) edge detection; (3) ANN-based feature recognition; (4) feature extraction. This approach was validated with a variety of real industrial components. The test results show that the developed feature-based RE application proved to be suitable for reconstructing prismatic features such as block, pocket, step, slot, hole, and boss, which are very common and crucial in mechanical engineering products.

  • PDF

Recurrence of equine coital exanthema in thoroughbred stallions

  • Yang, Jaehyuk;Lim, Yoon-Kyu
    • Korean Journal of Veterinary Research
    • /
    • v.53 no.3
    • /
    • pp.175-176
    • /
    • 2013
  • The object of this study was to evaluate recurrence of equine coital exanthema (ECE) whether re-infection or re-activation of causative virus. ECE is a venereal disease of horses caused by equine herpesvirus type 3 (EHV-3). Like other herpesviruses, it may persist in infected horses for a long time. There is a controversy on the cause of ECE as the recurrence or the reinfection. This disease had occurred firstly on stallions and broodmares in Korea. The horses had rebreeded after healing routinely. Next year, the disease recurrented on the just same affected horses among stallions. The result of this study, re-outbreak of ECE in stallions is recurrence of ECE, but not reinfection of the virus.

A Study on Unsteady Flow Characteristics of Closed Cavity with Obstacle (장애물을 갖는 밀폐공간의 비정상 유동특성에 관한연구)

  • 조대환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.176-183
    • /
    • 1999
  • This paper is aimed to investigate behaviour of vortex in 2-D step cavity with high Reynolds numbers$(3.2{\times}10^{3},\;10^{4},\;3{\times}10^{4},\;5{\times}10^{4}\;and\;7{\times}10^{4})$. The SOLA algorithm which is MAC type was adopted to solution method computing the flow field on irregular grid. In case of $Re=7{\times}10^{4}$ flow behavior is steady bu periodic unsteady sinusoidal fluctuation of local velocity and kinetic energy is found for $Re=10^{4}$ Continuous movements of small eddies in the secondary flow regions are discov-ered for $3{\times}10^{4}$ Generation of eddies and their active migrating behavior are detected over $Re=5{\times}10^{4}$ resulting in complete unsteady and non-linear flow characteristics Furthermore a typhoon-like vortex(TLV) appears intermittently and rotates along the separation regions and boundary layers.

  • PDF

A Study on Operating Lifetime of Cs3Sb Emitters in Panel Device Applications

  • Jeong, Hyo Soo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.3
    • /
    • pp.176-179
    • /
    • 2017
  • Non-vacuum processing technology was used to produce $Cs_3Sb$ photocathodes on substrates and fabricate in-situ panel devices. Electrical properties of these panel devices were characterized by measuring anode current and charge dose as functions of devices operation time. An excitation light source with a 475 nm wavelength was used for photocathodes. Results showed that emission properties of these photocathode emitters depended heavily on the vacuum level of these devices and that $Cs_3Sb$ flat emitters had the potential of operating for a long lifetime with stable electron emission characteristics via re-cesiation process in the panel device. These features make $Cs_3Sb$ photocathodes suitable as flat emitters in panel device applications.