• 제목/요약/키워드: Ray casting

검색결과 200건 처리시간 0.028초

Study on Ionic Conductivity and Crystallinity of PEO/PMMA Polymer Composite Electrolytes containing $TiO_2$ Filler ($TiO_2$ 필러를 포함하는 PEO/PMMA 고분자 복합체 전해질의 이온전도도 및 결정화도)

  • Lee, Lyun-Gyu;Park, Soo-Jin;Kim, Seok
    • Korean Chemical Engineering Research
    • /
    • 제49권6호
    • /
    • pp.758-763
    • /
    • 2011
  • In this work, polymer composite electrolytes were prepared by a blend of poly(methyl methacrylate) (PMMA) and poly(ethylene oxide) (PEO) as a polymer matrix, propylene carbonate as a plasticizer, $LiClO_4$ as a salt, and by containing a different content of $TiO_2$, by using the solution casting method. The crystallinity and ionic conductivity of the polymer electrolytes was evaluated using X-ray diffraction(XRD) and AC impedance method, respectively. The morphology of composite electrolyte film was analyzed by SEM method. From the experimental results, by increasing the $TiO_2$ content, crystallinity of PEO was reduced, and ionic conductivity was increased. In particular, the ionic conductivity was dependent on the content of $TiO_2$ and showed the highest value 15 wt%. However, when $TiO_2$ content exceeds 15 wt%, the ionic conductivity was decreased. According to the surface morphology, the ionic conductivity was decreased because the polymer composite electrolytes showed a heterogenous morphology of fillers due to immiscibility or aggregation of the filler within the polymer matrix.

High quality volume visualization using B-spline interpolation (B 스플라인 보간을 이용한 고화질 볼륨 가시화)

  • Shin, Yongha;Kye, Heewon
    • Journal of the Korea Computer Graphics Society
    • /
    • 제22권3호
    • /
    • pp.1-9
    • /
    • 2016
  • Linear interpolation is a basic sampling method for volume visualization. This method generates good images but sometimes it is inferior to our high expectation because it is encouraged to produce high quality images in the medical applications. In this paper, B spline based tri-cubic interpolation is used for the re-sampling step. The conventional B spline is an approximation method which does not cross control points so that we moved the control points and the curve crosses the original control points. In the rendering step, the empty space leaping is applicable to increase rendering speed. We have to calculate the maximum and minimum values for each block to detect empty space. The convex hull property of B spline enables the values of control points to be used as the maximum and minimum values. As a result, tri-cubic interpolated volume rendering is possible in interactive speed.

Studies in Iron Manufacture Technology through Analysis of Iron Artifact in Han River Basin during the Proto-Three Kingdoms

  • Kim, Soo-Ki
    • Conservation and Restoration of Cultural Heritage
    • /
    • 제1권1호
    • /
    • pp.9-22
    • /
    • 2012
  • The most widely excavated iron artifacts used as weapons or farm tools from central southern regions of Korea were subjects of non-metallic inclusion analysis through metallographic examination, microhardness measurement, and scanning electron microscopy with energy dispersive X-ray spectroscopy. Through metallographic interpretation and study of the analyzed results, the steel manufacturing and iron smelting using heat processing in the iron artifacts excavated from the central southern region of the ancient Korean peninsula was studied, and the analysis of the non-metallic inclusions mixed within the metallic structures was interpreted as the ternary phase diagram of the oxide to infer the type of iron ores for the iron products and the temperature of the furnace used to smelt them. Most of the ancient forged iron artifacts showed $Al_2O_3/SiO_2$ with high $SiO_2$ contents and relatively low $Al_2O_3$ contents for iron ore, indicating t hat for $Al_2O_3$ below 5%, it is presumed that magnetic iron ores were reduced to bloom iron (sponge iron) with direct-reduction process for production. The temperature for extraction of wustite for $Al_2O_3$ below 1% was found to be $1,020{\sim}1,050^{\circ}C$. Considering the oxide ternary constitutional diagram of glassy inclusions, the steel-manufacturing temperature was presumed to have been near $1,150{\sim}1,280^{\circ}C$ in most cases, and minimum melting temperature of casting iron part excavated in Daeseong-ri. Gyeonggi was near $1,400^{\circ}C$, and it is thought that hypoeutectic cast iron of about 2.3% carbon was casted and fragility of cast iron was improved by decarburizing in solid state.

Interlaced Scanning Volume Raycasting (비월주사식 볼륨 광선 투사법)

  • Choi, Ei-Kyu;Shin, Byeong-Seok
    • Journal of Korea Game Society
    • /
    • 제9권4호
    • /
    • pp.89-96
    • /
    • 2009
  • In general, the size of volume data is large since it has logical 3D structure so it takes long time to manipulate. Much work has been done to improve processing speed of volume data. In this paper, we propose a interlaced scanning volume rendering that reduce computation time by using temporal coherence with minimum loss of image quality. It renders a current frame by reusing information of previous frame. Conventional volume raycasting renders each frame by casting rays on every pixels. On the other hand, our methods divided an image into n-pixel blocks, then it casts a ray on a pixel of a block per each frames. Consequently, it generates an image by accumulating pixel values of previous n frames. The quality of rendered image of our method is better than that of simple screen space subsampling method since it uses afterimage effect of human cognitive system, and it is n-times faster that the previous one.

  • PDF

Passivation Layer (Thermosetting Film)가 형성된 유기박막 트랜지스터의전기적 특성 변화에 대한 연구

  • Seong, Si-Hyeon;Kim, Gyo-Hyeok;Jeong, Il-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.380-380
    • /
    • 2013
  • 본 논문에서는 외기 환경 요인 중에서 H2O와 O2의 영향으로 성능이 저하되는 유기박막트랜지스터(OTFT)의 수명시간 향상을 위하여 필요한 passivation layer의 효과에 대하여 알아 보았다. OTFT에 기존의 액상 공정이나 증착 공정으로 단일 passivation layer또는 다층 passivation layer를 형성하는 방식과는 다르게 향후에 산업 전반에 적용이 기대되는 것을 고려하여 제작 공정의 간편성을 위하여 film 형태로 되어 있는 열경화성 epoxy resin film으로 passivation layer를 구현하는 방법을 사용하여 OTFT의 storage stability를 평가하였다. passivation layer가 없는 OTFT와 열경화성 epoxy resin film으로 passivation된 OTFT의 전기적 특성이 서로 비교 평가되었으며 또한 30일 동안 온도 $25^{\circ}C$ 상대습도 40%의 환경을 갖는 Desicator 안에서 소자를 보관하여 시간에 따른 전기적 특성 변화를 검증하여 epoxy resin film의 passivation layer으로의 적용가능성을 검증하였다. 결과적으로 30일 후의 passivation layer가 없는 OTFT의 전기적 특성은 매우 낮게 떨어진 반면에 epoxy resin film으로 passivation layer가 구현된 OTFT의 mobility는 $0.060cm^2$/Vs, VT는 -0.18 V, on/off ratio는 $3.7{\times}10^3$으로 초기의 소자 특성이 잘 유지되는 결과를 얻었다. OTFT는 Flexible한 polyethersulfone (PES)기판에 게이트 전극이 하부에 있는 Bottom gate 구조로 제작되었고 채널 형성을 위한 유기반도체 재료로 6,13-bis (triisopropylsilylethynyl) (TIPS) pentacene이 사용되었고 spin coating된 Poly-4-vinylphenol (PVP)가 게이트 절연체로 사용되었다. 이때 Au전극은 Shadow mask를 이용하여 증착하였다. 또한 OTFT의 채널 길이 $100{\mu}m$, 채널 폭 $300{\mu}m$의 영역에 Drop casting법을 사용하여 채널을 형성하였다. 물리적 특성은 scanning electron microscopy (SEM), scanning probe microscopy (SPM), x-ray diffraction (XRD)를 사용하여 분석하였고, 전기적 특성은 Keithley-4200을 사용하여 추출하였다.

  • PDF

Efficient High Quality Volume Visualization Using Cardinal Interpolation (카디널 보간을 이용한 효율적인 고화질 볼륨 가시화)

  • Kye, Hee-Won
    • Journal of Korea Multimedia Society
    • /
    • 제14권3호
    • /
    • pp.339-347
    • /
    • 2011
  • As the volume visualization has been applied to render medical datasets, there has been a requirement to produce high quality images. Even though nice images can be generated by using previous linear filter, high order filter is required for better images. However, it takes much time for high order resampling, so that, overall rendering time is increased. In this paper, we perform high quality volume visualization using the cardinal interpolation. By enabling the empty space leaping which reduces the number of resampling, we achieve the efficient visualization. In detail, we divide the volume data into small blocks and leap empty blocks by referring the upper and lower bound value for each block. We propose a new method to estimate upper and lower bound value of for each block. As the result, we noticeably accelerated high quality volume visualization.

Scattered Light Representation in Accordance with the Material Using Scatterer Template in Volume Rendering (볼륨 렌더링에서 산란자 템플릿을 이용한 재질별 산란광 표현)

  • Lee, Byeong-Joon;Kwon, Koojoo;Shin, Byeong-Seok
    • KIPS Transactions on Software and Data Engineering
    • /
    • 제5권12호
    • /
    • pp.677-684
    • /
    • 2016
  • For realistic rendering volume to calculate the light effects as well as the shade is essential. In order to produce the high quality of the resulting image, it is necessary to represent a global illumination, and it should be considered an indirect effect of the direct impact and scattering of light. It requires a lot of resources in order to perform this operation and, in particular, is very expensive when large amounts of data to be rendered as a volume data is consumed. In this paper, we generate a scatterer template according to the physical laws for each material. Considering that each object having material property stores photons of the template based on the Lambert illumination model. When the volume rendering in this paper, using the photon is stored in the template, based on the voxel to be sampled within the examination volume occluded, and it represents the global illumination of the scattering. Because the materials produced by the template requires a less resource only if comprised of a complex material, a simple operation can be expressed within the scattering volume at a low cost through.

Study of PSII-treated PMMA, PHEMA, and PHPMA ; Investigation of Their Surface Stabilities

  • Hyuneui Lim;Lee, Yeonhee;Seunghee Han;Jeonghee Cho;Moojin suh;Kem, Kang-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 1999년도 제17회 학술발표회 논문개요집
    • /
    • pp.204-204
    • /
    • 1999
  • The plasma source ion implantation(PSII) technique which is a method using high negative voltage pulse in plasma system has the potential to change the surface properties of polymer. PSII technique increase the surface free energy by introducing polar functional groups on the surface so that it improves reactivity, hydrophilicity, adhension, biocompatability, etc. However, the mobility of polymer chains enables the modified surface layers to adapt their composition to interfacial force. This hydrophobic recovery interrupts the stability of modified surfaces to keep for the long time. In this study, poly(methyl methacrylate)(PMMA), poly(2-hydroxyethyl methacrylate)(PHEMA), and polu(2-hydroxypropyl methacylate)(PHPMA) for contact lens application, were modified to improve the wettability with PSII technique and were investigated the surface stabilities. Polymer film was prepared with solution casting(3 wt.% solution) and was annealed at 11$0^{\circ}C$ under vacuum oven to remove solvent completely and to eliminate physical ageing. The thickness of the film measured by scanning electron microscopy (SEM) and surface profilometer was about 10${\mu}{\textrm}{m}$. Polymers were treated with different kinds of gases, pulse frequency, pulse with, pulse voltage, and treatment time. Even though PMMA, PHEMA, and PHPMA have similar repeat unit structure, the optimal treatment conditions and the tendency to hydrophobic recovery were different. PHPMA, more hydrophilic polymer than PMMA and PHEMA showd better wettability and stability after mild treatment. Surface tensions were obtained by water and diiodomethane contact angle measurements to monitor the relation between hydrophobic recovery and polymer structure. Different ion species in plasma change the polar component and dispersion component of polymer surface. For better wettability surface, the increase of polar component was a dominant factor. We also characterized modified polymer surfaces using x-ray photoelectron spectroscopy(XPS), secondary ion mass spectrometry(SIMS), Fourier Transform infrared spectroscopy(FT-IR), and SEM.

  • PDF

The study on advertisement of dental devices & instrument during Japanese colonized period (광고를 통해 본 일제강점기 치과 장비 및 기구 광고에 관한 연구)

  • Shin, Jai-Eui
    • The Journal of the Korean dental association
    • /
    • 제48권12호
    • /
    • pp.893-918
    • /
    • 2010
  • This article is purposed of reviewing the development history of Japanese dental devices and instrument, and their related advertisement activities during the Japanese colonized period in Korea in early 20th century. Japanese dental devices and instrument were redesigned to accommodate their ergonomic shape above the simple imitation, and it implies the excessive desires brought them frustrations. The tragic earthquake on Sep. l, 1923, medical insurance law enforcement on Jan. 1, 1927, celebration of "Cavity prevention Day" started on Jun. 4, 1928, and the attack of Manchuria and China by Japan after 1931, all of these historical incidents become the preliminary requirement for the development of dental devices. On Nov. 1, 1937, Japanese government started to control dental materials, driving the campaigns for excluding foreign products and encourging the use of local products. In 1939, Nakajima dental manufacturers used this political and social atmosphere on their advertisement as saying "Our Nakajima's products have no compromise with the short raw materials, but only commitment to our quality". Since after 1940, the price and supply have been strongly under control, and the control group was appeared to manage all of supply and distribution of raw materials, regular price system, and specifications. At last, the Japanese national power were devastated in its production and distribution capacities, and get to the frustrated period. The main advertised dental devices and instruments in Korea during the Japanese colonized period were 1) dental chair, unit and cabinet, 2) dental x-ray, 3) compressors, 4) dental needles, 5) small instrument and carryon medical(emergency) kit, 6) oral hygiene and pyorrhea alveolaris, infrared rays, sunlight lamp, ultrashort wave treatment devices, 7)crown former, electric furnace, casting machine, articulator, electric lathe, and laboratory equipments, etc.

A STUDY FOR THE MEASUREMENTS OF THE RESIDUAL STRESS AND THE DISTORTIONS IN THE CERAMO-METAL BRIDGE OF Pd-Ag ALLOY (팔라듐-은 합금 도재소부전장 가공의치의 잔류응력과 변형에 관한 연구)

  • Jeon, Young-Chan;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제27권2호
    • /
    • pp.53-78
    • /
    • 1989
  • This study was taken to observe the changes of the residual stress in the alloy and to measure 3 dimensional distortions of the long span ceramo-metal bridge. The materials used in this study were Pors-on 4 (Pd-Ag alloy), and Ceramco and Vita VMK 68 powders. The residual stress of the alloy was measured on the six specimens (dia. 8m/m) by the X-ray diffraction stress analyzer according to the kind of ceramic powder and different measuring stages. And, for the measurement of the distortions, fifteen specimens of the anterior 8-unit ceramo-metal brige were fabricated and subjected to the 3-D coordinate measuring machine. Variables included the 2 kinds of a ceramic powder and the presence or absence of a splint bar at the cast metal framework. The measuring stages in both were after casting, after degassing and after glazing. The following conclusions were obtained : 1. The residual stress of the alloy showed increasing tendency for the tension by the ceramic fusing, but there was not significance. 2. The tendency of the distortions in the cast metal frameworks were decrease of the width, the anterior displacement and sagging. 3. The amount of the distortions at the degassing stage were greater than that at the ceramic fusing stage. 4. The splint bar was effective to control the distortion only at ceramic fusing stage. 5. The sagging distortion in the Ceramco firing were even through all measuring stages, but in the Vita firing, pronounced at degassing stage.

  • PDF