• Title/Summary/Keyword: Ray Method

Search Result 5,505, Processing Time 0.035 seconds

Two Crystal Structures of $Tl^+$ and $Zn^{2+}$ Exchanged Zeolite A, $Tl_{12-2x}Zn_x-A$ (x=4.3 and 3.25)

  • Mi Suk Jeong;Seong Hwan Song;Young Wook Han;Yang Kim
    • Bulletin of the Korean Chemical Society
    • /
    • v.11 no.2
    • /
    • pp.150-154
    • /
    • 1990
  • The structures of $Tl_{12-2x}Zn_x-A$ (x = 4.3 and 3.25), vacuum dehydrated zeolite A with all $Na^+$ ions replaced by $Tl^+$ and $Zn^{2+}$ as indicated, have been determined by single-crystal X-ray diffraction techniques in cubic space group Pm3m at 21(1) $^{\circ}C$ (a=12.100(2) ${\AA}$ for $Tl_{3.4}Zn_{4.3}-A$ and a=12.092(2) ${\AA}$ for $Tl_{5.5}Zn_{3.25}-A$). The crystals of $Tl_{3.4}Zn_{4.3}-A$ and $Tl_{5.5}Zn_{3.25}-A$ were prepared by flow method using exchange solutions in which mole ratios of $TlNO_3$,/TEX> and $Zn(NO_3)_2$ were 1:50 and 1:1, respectively, with total concentration of 0.05 M. The structures of the dehydrated $Tl_{3.4}Zn_{4.3}-A$ and $Tl_{5.5}Zn_{3.25}-A$ were refined to yield the final error indices $R_1$ = 0.075 and $R_2$ = 0.075 with 236 reflections, and $R_1$ = 0.057 and $R_2$ = 0.064 with 202 reflections, respectively, for which I > 3$\sigma$(I). Both structures indicate that Zn(II) ions are coordinated by three framework oxygens: the Zn(II) to O(3) distances are 2.08(1) ${\AA}$ for $Tl_{3.4}Zn_{4.3}-A$ and 2.07(1) ${\AA}$ for $Tl_{5.5}Zn_{3.25}-A$, respectively. In each structure, the angle subtended at Zn(II), O(3)-Zn(II)-O(3) is 119.9(3)$^{\circ}$ for $Tl_{3.4}Zn_{4.3}-A$, and 120.0(3)$^{\circ}$ for $Tl_{5.5}Zn_{3.25}-A$, respectively, close to the idealized trigonal-planar value. Zn(II) ions prefer to 6-ring sites. $Tl^+$ ions do not have any preference to a particular site but occupy simultaneously both at the 6-ring sites and 8-ring sites.

Comparison of CT Image Performance with or without Tin Filter based on Blind Image Quality Evaluation Method (블라인드 품질 평가 방법을 사용한 주석필터 사용 유무에 따른 CT 영상 특성 비교)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.301-306
    • /
    • 2021
  • The use of tin filters as a way to reduce the medical radiation in computed tomography (CT). However, due to the changed X-ray spectrum with the use of tin filters, disease diagnosis could be affected because it appears as images of different impressions from previous images. Therefore, this study evaluates the changes in images when using tin filter and high pitch in chest low-dose CT. In this study, images were acquired in groups of three for comparison. Group 1 did not apply to tin filter, and used the existing pitch 0.8. Group 2 used a tin filter, pitch 0.8, Group 3 used a tin filter, and pitch 2.5. To compare the image quality, the natural image quality evaluator (NIQE) and the blind/referenceless image quality evaluator (BRISQUE) were used among the blind quality evaluation factors depended on a no-reference basis. As a result, the NIQE values were low in the order of Group 1, Group 3, and Group 2. BRISQUE values were low in the order of Group 3, Group 2 and Group 1. This study confirms the superiority of images of tin filter and high pitch techniques in chest low-dose CT, which is considered to be a fundamental study for acquiring accurate images of patients with difficult breathing control.

Temperature Dependent Optical Performance of the NaSr(PO3)3:Eu2+ Blue Phosphors (NaSr(PO3)3:Eu2+ 청색 형광체의 온도 의존적 형광 특성)

  • Yoon, Chang yong;Lee, Sang ho
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.391-399
    • /
    • 2021
  • Eu2+ doped polyphosphate NaSr(PO3)3 blue-emitting phosphors were synthesized by the conventional solid state method in a reductive atmosphere. The phase formation of NaSr(PO3)3 phosphors were characterized by using the X-ray powder diffraction (XRD) measurement. The photoluminescence emission and excitation spectra of the NaSr(PO3)3:Eu2+ phosphor, and decay curves were measured. Under the near-UV excitation, the phosphor exhibits a band emission around 420 nm assigned to the 4f65d→f7(8S7/2) transition of Eu2+. The temperature dependent emission spectra and decay curves were measured to elevate the thermal properties of the Eu2+ doped phosphors. The as-prepared NaSr(PO3)3:Eu2+ phosphors show a strong temperature dependent performance, which can serve as a promising temperature sensor.

Study on the Production Methods and Conservation Treatment of the Gold Earrings Excavated from the Ancient Tombs in Seokchon-dong in Seoul (석촌동 고분군 출토 금제이식의 제작기법 연구 및 보존처리)

  • Kim, Yeseung;Jeong, Seri;Lee, Dahye;Jang, Minkyeong;Kim, Naeun;Yang, Seokjin
    • Conservation Science in Museum
    • /
    • v.26
    • /
    • pp.143-160
    • /
    • 2021
  • The Seoul Baekje Museum has been conducting excavations at the Ancient Tomb Complex in Seokchon-dong, Seoul (Historic Site No. 243), known to be tombs of the royal family and the ruling class during the Hanseong period of the Baekje Kingdom. In this study, gold earrings that were revealed during the excavation underwent scientific analysis and conservation treatment. Stereo microscopy, SEM, X-ray imaging, CT, and XRF were applied in the analysis, and the characteristics, internal structure, and composition of the earrings as well as their production method were investigated. The results confirmed that the main hoops of the gilt-bronze earrings were made of copper cores gilt using mercury amalgamation. The findings also revealed that the hexahedron in the middle pendant was made by connecting small rings using molten gold powder, and the pendant sphere at the end was formed by soldering two hemispheres. As for the two thin-hoop earrings, they showed similar surface compositions but were made using different methods, with one made from a copper core wrapped with a gold plate and the other made by bending a gold rod. The gold content varied depending on the item and the place of measurement, but overall the earrings showed a relatively high gold content of approximately 19 to 21K. The purity of the golden earrings and the sophisticated manufacturing techniques applied indicate the high status of the buried person and of the tomb complex in Seokchong-dong.

Development of High-Sensitivity and Entry-Level Nuclide Analysis Module (고감도 보급형 핵종 분석 모듈 개발)

  • Oh, Seung-Jin;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.515-519
    • /
    • 2022
  • In this paper, we propose the development of a high-sensitivity entry-level nuclide analysis module. The proposed measurement sensor module consists of an electronic driving circuit for nuclide analysis resolution, prototype production with nuclide analysis function, and GUI development applied to prototypes. The electronic part driving circuit for nuclide analysis resolution is divided into nuclide analysis resolution process by the electronic part driving circuit block diagram, MCU circuit design used for radiation measurement, and PC program design for Spectrum acquisition. Prototyping with nuclide analysis function is made by adding a 128×128 pixel OLED display, three buttons for operation, a Li-ion battery, and a USB-C type port for charging the battery. The GUI development department applied to the prototype develops the screen composition such as the current time, elapsed measurement time, total count, and nuclide Spectrum. To evaluate the performance of the proposed measurement sensor module, an expert witness test was conducted. As a result of the test, it was confirmed that the calculated result by applying the resolution formula to the Spectrum (FWHM@662keV) obtained using the Cs-137 standard source in the nuclide analysis device had a resolution of 17.77%. Therefore, it was confirmed that the nuclide analysis resolution method proposed in this paper produces improved performance while being cheaper than the existing commercial nuclide analysis module.

Setting Time Evaluation on Cement Paste with Retarder Using Non-Destructive Measurements (비파괴 측정법을 이용한 지연제 첨가 시멘트 페이스트의 응결 평가)

  • Ahn, Yu-Rhee;Jun, Yu-Bin;Yim, Hong Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.4
    • /
    • pp.48-56
    • /
    • 2022
  • Controlling the setting time of cementitious materials is one of the most important factors in securing early-age performance of concrete structures. Recently, the use of retarding admixtures, which enable the inhibition of some hydration products to control the securing time due to average temperature rise is suggested. Although various non-destructive evaluation methods have been proposed to evaluate cement hydration and hardening of cement-based materials to overcome the limitations of Vicat needle test, experimental research is still required to use the non-destructive evaluation method with added retarding admixtures. In this study, measurements of electrical resistivity and ultrasonic wave velocity in early-aged cement pastes were performed according to the addition of retarding admixture(tartaric acid). The setting time of the cement pastes was evaluated by obtained rising time of the both non-destructive measurements. As a result, the possibility of evaluating the setting delay in cement pastes was confirmed through comparative analysis with the initial and final setting times by Vicat test. In addition, X-ray diffraction results at the rising time of electrical resistivity showed a key hydration product affecting the setting delay.

Effect of Mechanical Thermal Massage Inducing Gradual Spinal Segmentation on the Improvement of Pain (단계적 척추 분절운동을 유도하는 기계식 온열 마사지가 통증 개선에 미치는 영향)

  • Hyeun-Woo, Choi;Do-Hyun, Ahn;Kyung-Mi, Jung;Na-Young, Kim;Ji-Eun, Lee;Jong-Min, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.879-887
    • /
    • 2022
  • In this study, we tried to confirm whether the mechanical sequential elevation method of the body pressure measuring bed actually induces segmental motion for each part of the spine. To this end, a lateral X-ray examination was performed, and it was confirmed that the sequential pressure device induces a step-wise segmentation of the spine by mechanically lifting each part of the spine vertically. Then, pain, walking ability, and depression scale were measured and analyzed in subjects who were aware of back pain. VAS(p<0.05) and ODI(p<0.05) for 10 days tended to decrease in average after bed use. In the gait ability test(p<0.05), as the number of times of bed use increased, the moving time in the test decreased and the moving distance increased. In addition, GSDDF(p<0.05) decreased after bed use. As a result, it was confirmed that the spinal segmentation caused by the heat and acupressure provided by the bed affected gait and depression as well as pain relief.

Noise Measurement by Percentage of Effective Linear Attenuation Coefficient of Water in CT Image of AAPM CT Performance Phantom (AAPM CT 성능 팬텀의 CT영상에서 물 유효선감쇠계수의 백분율에 의한 노이즈 측정)

  • Jong-Eon, Kim;Sang-Hun, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.771-778
    • /
    • 2022
  • The purpose of this study is to present a method of measuring noise by the percentage of effective line attenuation coefficient of water that can be used for quality control of CT image noise using AAPM CT performance phantom in clinical practice. In the CT images obtained by scanning the AAPM CT performance phantom with a 120 kVp CT X-ray beam, the mean CT number was measured for each pin and water in the CT number linearity insert part. The effective energy was determined as the photon energy with the largest correlation coefficient from the correlation coefficients of the linear regression analysis of the measured mean CT number for each pin and water and the linear attenuation coefficient for each photon energy. And for water and acrylic, the contrast scale was calculated as 0.000188 cm-1 · HU-1 from the measured mean CT number and effective line attenuation coefficient. Using the calculated contrast scale, the effective line attenuation coefficient of water, and the standard deviation measured in the water of the alignment pin part of the AAPM CT performance phantom, The noise measurement value by the percentage of effective line attenuation coefficient of water obtained 0.31 ~ 0.52% in the range of 100 ~ 300 mAs.

A Study on the Feasibility of Lead(II) Iodide and Gd2O2S:Tb Overlapping Sensors in Gamma Source Conditions using FLUKA Simulation (FLUKA 전산 모사를 통한 감마선원 조건에서의 요오드화납(II)과 Gd2O2S:Tb가 결합된 센서의 적용가능성 연구)

  • Yang, Seung-Woo;Park, Yoon-Hee;Park, Ji-Koon;Heo, Ye-Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.381-386
    • /
    • 2022
  • Non-Destruction Test (NDT) is a method to check internal defects without destroying the product. Among them, radiographic testing (RT) uses high-energy radiation, so it is very important to prevent radiation exposure of workers. Therefore, in this study, in this study, a radiation sensor structure that improves radiation detection performance compared to the existing PbI2 and can immediately detect accidents in RT was presented. For evaluation, the conversion efficiency was analyzed in the gamma ray source through FLUKA simulation. PbI2 with overlapping Gd2O2S:Tb presented in this study showed a higher radiation sensitivity from 1.22 to 3.22 times than that of non-overlapping PbI2. This indicates that the presented sensor is suitable for use as a radiation sensor for source detection in RT.

Degradation of Antibiotics Using Silver Decorated Heterojunction Carbon Nitride under Visible Light (은 장식 이종접합 질화탄소를 이용한 가시광선 조건에서의 항생제 분해 연구)

  • Taeyoon, Lee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.3
    • /
    • pp.23-27
    • /
    • 2023
  • Graphitic carbon nitride (g-C3N4) has been used as effective photocatalyst for degradation of antibiotics under visible light irradiation. However, the fast recombination of hole-electron pair may limit their photocatalytic efficiency. In our study, Ag was grafted on g-C3N4/g-C3N4 isotype heterojunction by a microwave-assisted decomposition method. The structure and physical properties of heterojunction photocatalyst were characterized through X-ray diffraction, UV-DRS, FT-IR, and Photoluminescence analyses. Ag decorated g-C3N4/g-C3N4 isotype heterojunction exhibited excellent photocatalytic activity for degradation of sulfamethoxazole under irradiation under visible light irradiation within 210 min, which is higher than g-C3N4/g-C3N4 isotype heterojunction and bulk g-C3N4. The addition of Ag may broaden the visible light absorption and restrict the recombination of hole-electron pair because of the surface plasmons resonance, resulting in the improving the photocatalytic activity.