• Title/Summary/Keyword: Ray Method

Search Result 5,505, Processing Time 0.039 seconds

Physical and Electrochemical Properties of Gallium Oxide (β-Ga2O3) Nanorods as an Anode Active Material for Lithium Ion Batteries (리튬이온전지용 산화갈륨 (β-Ga2O3) 나노로드 (Nanorods) 음극 활물질의 물리적.전기화학적 특성)

  • Choi, Young-Jin;Ryu, Ho-Suk; Cho, Gyu-Bon;Cho, Kwon-Koo;Ryu, Kwang-Sun;Kim, Ki-Won
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.2
    • /
    • pp.189-195
    • /
    • 2009
  • $\beta-Ga_{2}O_{3}$ nanorods were synthesized by chemical vapor deposition method using nickel-oxide nanoparticle as a catalyst and gallium metal powder as a source material. The average diameter of nanorods was around 160 nm and the average length was $4{\mu}m$. Also, we confirmed that the synthesis of nanorods follows the vapor-solid growth mechanism. From the results of X-ray diffraction and HR-TEM observation, it can be found that the synthesized nanorods consisted of a typical core-shell structure with single-crystalline $\beta-Ga_{2}O_{3}$ core with a monoclinic crystal structure and an outer amorphous gallium oxide layer. Li/$\beta-Ga_{2}O_{3}$ nanorods cell delivered capacity of 867 mAh/g-$\beta-Ga_{2}O_{3}$ at first discharge. Although the Li/$\beta-Ga_{2}O_{3}$ nanorods cell showed low coulombic efficiency at first cycle, the cell exhibited stable cycle life property after fifth cycle.

Adsorption of CO2 on Monoethanol Amine-Impregnated ZSM5 and MS13X (Monoethanolamine을 함침한 ZSM5와 MS13X의 CO2 흡착특성 비교)

  • Choi, Sung-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.6
    • /
    • pp.325-331
    • /
    • 2017
  • Adsorption experiments of carbon dioxide were performed on ZSM5 and Molecular Sieve 13X (MS13X) impregnated with Monoethanol Amine (MEA). Adsorption efficiency of $CO_2$ was investigated in a U type packed column with GC/TCD. The adsorption capacities of adsorbents are estimated in the temperature range of $30-80^{\circ}C$. The modified adsorbents was characterized by BET surface area, $N_2$ adsorption/desorption isotherms, X-ray diffraction and FT-IR. Surface analysis results showed that the impregnation method did not affect the crystallinity of any adsorbents. BET surface area of the MS13X impregnated amine decreased to $19.945m^2/g$ from $718.335m^2/g$. These reults showed that amine molecules were filled with the pore volume in MS13X, as a results restricting access of nitrogen into the pores. The MEA modified MS13X showed improvement in $CO_2$ adsorption capacity over the ZSM5 impregnated with MEA. The MS13X-MEA showed the highest adsorption capacity due to physical adsorption and chemical adsorption by amino-group content. This results also showed that adsorption capacity of MS13X-MEA increases with the temperature range of $60-80^{\circ}C$ compared with pristine MS13X.

Morphometric Characteristics and Fin Dimorphism between Male and Female on the Marine Medaka, Oryzias dancena

  • Im, Jae Hyun;Gil, Hyun Woo;Lee, Tae Ho;Kong, Hee Jeong;Ahn, Cheol Min;Kim, Bong Seok;Kim, Dong Soo;Zhang, Chang Ik;Park, In-Seok
    • Development and Reproduction
    • /
    • v.20 no.4
    • /
    • pp.331-347
    • /
    • 2016
  • Sexual dimorphism is the most conspicuous difference between the sexes. This study examines possible sexual dimorphism and the relative growth patterns of morphometric characteristics in the marine medaka, Oryzias dancena for their potential to help differentiate between males and females of this species. The von Bertalanffy growth parameters estimated by a non-linear regression method were $L_{\infty}=30.2mm$, K=3.22/year, and ${\tau}_0=-0.05$. All 18 characteristics measured showed a difference between males and females from 70 days after hatching. Each of these characteristics were significantly different between sexes (ANCOVA, P<0.05), and the ratio of standard length between sexes showed that males were larger than females for all five morphometric measurements. Fin length measurements were taken for 21 distances of anal fin and 7 distances of dorsal fin between landmarks. There were all differences for all dorsal fin rays between the males and the females and there is significant difference in 70 days after their hatch when the sexual dimorphism is presented. The significant difference (P<0.05) in fin ray for male and female was more greatly seen as they grow. Male marine medaka showed more rapid growth than females, with longer length, dorsal fins and anal fins. Differences in these characteristics will be useful during experiments when it is necessary to differentiate between sexes of marine medaka.

Study on Performance Evaluation of Dental X-ray Equipment (치과 방사선 발생기의 성능평가에 관한 연구)

  • Jung, Jae-Eun;Jung, Jae-Ho;Kang, Hee-Doo;Lee, Jong-Woong;Ra, Keuk-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.115-119
    • /
    • 2009
  • I think this will be valuable reference for assuring consistency and homogeneity of clarity and managing dental radiation equipment by experimentation of dental radiation equipment permanent which based on KS C IEC 61223-3-4 standard and KS C IEC 61223-2-7. Put a dental radiation generator and experiment equipment as source and film(sensor) length within 30 em, place the step-wedge above the film(sensor). Tie up tube voltage 60 kVp, tube current 7 mA and then get an each image through CCD sensor and film by changing the exposure time as 0.12sec, 0.25sec, 0.4sec. Repeat the test 5times as a same method. Measure the concentration of each stage of film image, which gained by experiment, using photometer. And the image that gained by CCD sensor, analyze the pixel value's change by using image J, which is analyzing image program provided by NIH(National Institutes of Health). In case of film, while 0.12sec and 0.25sec show regular rising pattern of density gap as exposure time's increase, 0.4sec shows low rather than 0.12sec and 0.25sec. In case of CCD sensor density test, the result shows opposite pattern of film. This makes me think that pixels of CCD's sensor can have 0~255 value but it becomes saturation if the value is over 255. The way that getting clear reception during decreasing human's exposed radiation is one of maintaining an equipment as a best condition. So we should keeping a dental radiation equipment's condition steadily through cyclic permanent test after factor examination. Even digital equipment doesn't maintain a permanent, it can maintain a clarity by post processing of image so that hard to set it as standard of permanent test. Therefore it would be more increase the accuracy that compare a film as standard image. Thus I consider it will be an important measurement to care for dental radiation equipment and warrant homogeneity, consistency of dental image's clarity through comparing pattern which is the result from factor test against cyclic permanent test.

  • PDF

The Effects of Diagnostic Radiology Image on Radiopharmaceutical Testing (방사성의약품 검사 시 진단(CT)영상에 미치는 영향)

  • Lee, Eun-Hye;Lee, Ye-Seul;Kim, Gha-Jung;Choi, Jun-Gu
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.113-117
    • /
    • 2010
  • This research attempts to qualitatively evaluate the intensity change by radiopharmaceuticals and obtain computed tomography using phantom injected with various nuclide. Cylindrical phantom is used for comparing and analysing the effect on diagnosis image during radiopharmaceuticals inspection. Inside of the phantom, water is injected and computed tomography image is scanned. During nuclear medicine invitro, frequently used radiopharmaceuticals, $^{99m}TcO_4$ 20 mCi and $^{18}F$ 14 mCi, is diluted in the water phantom and scanned in the same method. Traverse image obtained by CT scan is divided into six traverse image in the same slice of each scanned image. CT-number(HU) value of 10 measuring point is measured in 2 cm interval based on the center of the phantom. Measured HU value, based on the water phantom, is compared with the image after injecting $^{99m}TcO_4$ and $^{18}F$. Average scale of water is 2.8~1.6 HU, $^{99m}TcO_4$ is 3.0~1.6 HU and $^{18}F$ is 1.2~0 HU. Average of water is $2.3{\pm}0.17$ HU, $^{99m}TcO_4$ is $2.2{\pm}0.85$ HU and F-18 is $0.7{\pm}0.95$ HU. Based on water, reduced value of about 0.1 HU and about 0.5 HU is acquired from $^{99m}TcO_4$ and F-18. Radionuclide used in nuclear medicine inspection utilizes 100~200 KeV energy and obtains image through scintillation camera and PET-CT utilizes 511 KeV positron annihilation energy to obtain image. What we learned from this research is that gamma rays from these energies used in CT scan for diagnosis purpose or radioactive therapy plan can change the intensity of the image. The nuclear medicine inspection for reducing the effect of emitted gamma ray diagnosis image should be obtained after a period of time considering half-life which would be reduced distortion or changed in image.

  • PDF

Development of Packaging Materials for MA Packaging(1) (MA포장용 기능성 포장 소재개발에 관한 연구(1))

  • Park, Hyung-Woo;Park, Moo-Hyun;Kim, Hoon;Lee, Jae-Young;Yang, Han-Chul
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.3 no.2
    • /
    • pp.25-31
    • /
    • 1996
  • Various treaments such heating, acid tenting, acid healing, alkaline treating, acid+alkaline renting were attempted to investigate their effects on molar ratio, chemical composition, DTA and specific surface area(SSA) of natural zeolite poder. Molar ratio, Si to AI. of natural zeolite was 4.78, which represented high silica type. Composition of natural zeolite showed that $SiO_2$ was 66.34% $Al_2O_3$ was 13.89%, $Fe_2O_2$ was 1.55% X-ray diffraction showed that main component of natural zeolite was mordenite and clinoptliolite. Differential Thermal Analysis and Thermogravimetry curve of natural zeolite was showed to peak of endothermic peak at $80^{\circ}C$ and it means to the peak of dehydrate reaction, but recristalization was not formed below at $1,000^{\circ}C$. Weight loss during calcination was 16% at $1,000^{\circ}C$. Thermal treatments on SSA of natural zolite powder decreased from $75.2m^2/g\;to\;2.1m^2/g$. In contrast chemical treatments on SSA showed to increase to $300.2m^2/g$(1 N HCl treating), $54.9m^2/g$(1 N NaOH) and $90.9m^2/g$(HCl+NaOH)tudy, it could be proposed to employ acid tret method as packaging materisls for MA packaging.

  • PDF

Synergistic Effect of Green Tea EGCG Treatment with Gamma Radiation in Ieukemia Cell Necrosis (방사선조사와 병행 처리한 녹차 EGCG의 혈구암세포 사멸촉진 효과)

  • Lee, Hong-Soo;Kim, Jae-Man
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.285-291
    • /
    • 2006
  • During cancer therapy, gamma-ray irradiation and treatment of anti-cancer chemicals destroy the normal cells as well as cancer cells. In this study, we investigated the effect of epigallocathechin-gallate(EGCG) extracted from green tea, which is known to have anti-cancer and anti-oxident activities, in order to find out the feasible method to protect the normal cells and to kill the cancer cells efficiently. We investigated the effect of EGCG on the leukemia cell growth and cell necrosis, especially when treated along with gamma radiation. The EGCG inhibited the leukemia cell, HL-60, growth at the appropriate concentration while it exhibited no influence on the normal cell growth. More significantly, it enhanced leukemia cell necrosis when its treatment was combined with gamma irradiation. Simultaneous treatment of EGCG and gamma radiation increased leukemia cell necrosis up to 35% compared with separate treatments. These results suggest that drinking of green tea or co-treatment of EGCG during gamma irradiation therapy may result in better prognosis through enhancement of the tumor cell necrosis and protection of the normal cells.

  • PDF

Management of Traumatic Diaphragmatic Rupture (외상성 횡격막 손상의 치료)

  • Kim, Seon Hee;Cho, Jeong Su;Kim, Yeong Dae;I, Ho Seok;Song, Seunghwan;Huh, Up;Kim, Jae Hun;Park, Sung Jin
    • Journal of Trauma and Injury
    • /
    • v.25 no.4
    • /
    • pp.217-222
    • /
    • 2012
  • Purpose: Diaphragmatic rupture following trauma is often an associated and missed injury. This report is about our experience with treating traumatic diaphragmatic rupture (TDR). Methods: From January 2007 to September 2012, 18 patients who had a diaphragmatic rupture due to blunt trauma or penetrating injury underwent an operation for diaphragmatic rupture at our hospital. We retrospectively reviewed their medical records, including demographic factors, initial vital signs, associated injuries, interval between trauma and diagnosis, injured side of the diaphragm, diagnostic tools, surgical method or approaches, operative time, herniated organs, complications, and mortality. Results: The average age of the patients was 43 years, and 16 patients were male. Causes of trauma included motor vehicle crashes (n=7), falls (n=7), and stab wounds (n=5). The TDR was right-sided in 6 patients and left-sided in 12. The diagnosis was made by using a chest X-ray (n=3), and thorax or upper abdominal computed tomography (n=15). Ten(10) patients were diagnosed within 12 hours. A thoracotomy was performed in 8 patients, a video-assisted thoracoscopic surgery in 4 patients, a laparotomy in 3 patients, and a sternotomy in one patient. Herniated organs were the omentum (n=11), stomach (n=8), spleen and colon (n=6), and liver (n=6). Eighteen diaphragmatic injuries were repaired primarily. Seven patients underwent ventilator care, and two of them had pneumonia and acute respiratory distress syndrome. There were no operative mortalities. Conclusion: Early diagnosis and surgical treatment determine the successful management of TDR with or without the herniation of abdominal organs. The surgical approach to TDR is chosen based on accompanying organ injuries and the injured side.

Diagnosis of Work-related Musculoskeletal Disease through Moire Image Pattern and Treatment Measure using a Sling System (Moire' 영상무늬를 통한 근골격계질환의 진단과 현가장치를 이용한 치료방안)

  • Lee Sang-Yong;Lee Eun-Kyong;Kwon So-Hee;Jung He-Kyong;Kim Sam-Tae;Chong Myong-Soo;Lee Ki-Nam
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.7 no.2
    • /
    • pp.121-130
    • /
    • 2003
  • The Musculoskeletal Disease has been ignored or turned away due to the difficulty of diagnosis and the vagueness of judgement up to now. Contrary to other diseases, there were many cases where the character of the Musculoskeletal Disease wasn't revealed through the objective inspection. And that's because the Musculoskeletal Disease appears for the most part due to muscular defect so it is impossible to diagnose the muscle by X-ray diagnosing the bone and it is also impossible to diagnose the fine damage of the muscle or tendon even by advanced device like MRI. As the nervous blood vessels or acupunctures pass through or are next to the muscle, the tension of the muscle put pressure on these so can become the direct or indirect causes of various kinds of pains or intern diseases. But in spite of that, for lack of proper equipment diagnosing the state of the muscle(Shortened.. Relaxed... or Hardened...) the muscle has been disregarded or neglected intentionally or unintentionally. While many people think themselves to be a muscular expert, if they don't see the shape of the muscle, that is just like blind treatment. But as now the equipment diagnosing the state of the muscle is developed, it seems that this problem can be settled. It was attempted in this study that the muscle or skeleton of the Musculoskeletal disease patients was diagno the treatment order and method were decided by a questionnaire survey and simple inspection, and the Musculoskeletal correction exercise using the muscle management and sling system made them escape from the Musculoskeletal disease, turning their muscle into more flexible and stronger muscle. As a result notwithstanding the limited treatment period '12 times', the improvement rate was as high as 74%, which showed that the muscle management and Musculoskeletal correction exercise had a great effect on the symptom improvement of the patients. If the treatment times had increased, the improvement rate also would have increased more.

  • PDF

A Study on the Validation of Effective Angle of Particle Deposition according to the Detection Efficiency of High-purity Germanium Gamma-ray Detector (고순도 저마늄 감마선 검출기의 검출효율에 따른 유효입체각 검증에 관한 연구)

  • Chang, Boseok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.487-494
    • /
    • 2020
  • The distance between the source and the detector, the diameter of the detector, and the volume effect of the radiation source result in a change in solid angle at the detector entrance, which affects the determination of detection efficiency by causing a difference in path length within the detector. A typical analysis method for calculating solid angles was useful only for a source (60Co) with a simple geometric structure, so in this experiment, the distance between the detector and the source was measured by switching on for up to 25 cm with the reference point of window cap 0.5 cm. In addition, 450 and 1000 ㎖ Marinelli beaker of standard volumetric sources were closely adhered to the detector. For circular point sources co-axial with the detector, the change in the solid angle to the distance from the detector window is equal to half the square radius of the source versus the square radius of the detector, if the resulting relationship of the calculation analysis results in the detector being less than the radius of the source. Since the solid angular difference is 0.5 the result of Monte Carlo is acceptable. The relationship between detector and source distance is shown. Solid angles have been verified to decrease rapidly with distance. Measurement and simulation results for a volumetric source show a difference of ±1.01% from a distance of 0 cm and less than 4 % when the distance is reduced to 5 and 10 cm. It can be seen that the longer distance, the smaller efficiency angle, and the exponential increase in attenuation as the energy decreases, is reflected in the calculation of efficiency. Thus, the detection efficiency has proved sufficient for the use of solid angle and Monte Carlo codes.