• Title/Summary/Keyword: Ray Method

Search Result 5,505, Processing Time 0.037 seconds

The Manufacture of Digital X-ray Devices and Implementation of Image Processing Algorithm (디지털 X-ray 장치 제작 및 영상 처리 알고리즘 구현)

  • Kim, So-young;Park, Seung-woo;Lee, Dong-hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.195-201
    • /
    • 2020
  • This study studied scoliosis, one of the most common modern diseases caused by lifestyle patterns of office workers sitting in front of computers all day and modern people who use smart phones frequently. Scoliosis is a typical complication that takes more than 80% of the nation's total population at least once. X-ray are used to test for these complications. X-ray, a non-destructive testing method that allows scoliosis to be easily performed and filmed in various areas such as the chest, abdomen and bone without contrast agents or other instruments. We uses NI DAQ to miniaturize digital X-ray imaging devices and image intensifier in self-shielding housing with Vision Assistant for drawing lines to the top and the bottom of the spine to acquire angles, i.e. curvature in real-time. In this way, the research was conducted to see scoliosis patients and their condition easily and to help rapid treatment for solving the problem of posture correction in modern people.

A Tuberculosis Detection Method Using Attention and Sparse R-CNN

  • Xu, Xuebin;Zhang, Jiada;Cheng, Xiaorui;Lu, Longbin;Zhao, Yuqing;Xu, Zongyu;Gu, Zhuangzhuang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.7
    • /
    • pp.2131-2153
    • /
    • 2022
  • To achieve accurate detection of tuberculosis (TB) areas in chest radiographs, we design a chest X-ray TB area detection algorithm. The algorithm consists of two stages: the chest X-ray TB classification network (CXTCNet) and the chest X-ray TB area detection network (CXTDNet). CXTCNet is used to judge the presence or absence of TB areas in chest X-ray images, thereby excluding the influence of other lung diseases on the detection of TB areas. It can reduce false positives in the detection network and improve the accuracy of detection results. In CXTCNet, we propose a channel attention mechanism (CAM) module and combine it with DenseNet. This module enables the network to learn more spatial and channel features information about chest X-ray images, thereby improving network performance. CXTDNet is a design based on a sparse object detection algorithm (Sparse R-CNN). A group of fixed learnable proposal boxes and learnable proposal features are using for classification and location. The predictions of the algorithm are output directly without non-maximal suppression post-processing. Furthermore, we use CLAHE to reduce image noise and improve image quality for data preprocessing. Experiments on dataset TBX11K show that the accuracy of the proposed CXTCNet is up to 99.10%, which is better than most current TB classification algorithms. Finally, our proposed chest X-ray TB detection algorithm could achieve AP of 45.35% and AP50 of 74.20%. We also establish a chest X-ray TB dataset with 304 sheets. And experiments on this dataset showed that the accuracy of the diagnosis was comparable to that of radiologists. We hope that our proposed algorithm and established dataset will advance the field of TB detection.

FINDING COSMIC SHOCKS: SYNTHETIC X-RAY ANALYSIS OF A COSMOLOGICAL SIMULATION

  • HALLMAN ERIC J.;RYU DONGSU;KANG HYESUNG;JONES T. W.
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.5
    • /
    • pp.593-596
    • /
    • 2004
  • We introduce a method of identifying evidence of shocks in the X-ray emitting gas in clusters of galaxies. Using information from synthetic observations of simulated clusters, we do a blind search of the synthetic image plane. The locations of likely shocks found using this method closely match those of shocks identified in the simulation hydrodynamic data. Though this method assumes nothing about the geometry of the shocks, the general distribution of shocks as a function of Mach number in the cluster hydrodynamic data can be extracted via this method. Characterization of the cluster shock distribution is critical to understanding production of cosmic rays in clusters and the use of shocks as dynamical tracers.

Noise Prediction of Train Using Ray Tracing Method and Statistical Energy Analysis (음선추적법과 통계적 에너지 분석법을 이용한 철도차량 실내 소음 해석)

  • Park, Hee-Jun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.942-946
    • /
    • 2010
  • As the major sources of interior noise of train at running condition are the wheel/rail contact noise, the traction motor's noise and the driving gear's noise and these noise sources are transmitted through the car body, the noises of HVAC and air duct can be ignored. But the interior noise of train at standstill condition is decided by HVAC's noise and noise from the diffuser through the air duct. the interior noise prediction of train at standstill condition should be performed considering the shape of air duct, the air velocity and noise reduction property inside the air duct. But it is hard to estimate the interior noise level by the numerical method. Therefore train maker predict the interior noise level using The commercial noise prediction program. This paper introduce the noise prediction method of the train at standstill condition using the commercial program appling the ray tracing method and statistical energy analysis.

  • PDF

Fabrication of Single Crystal Poly(3,4-ethylenedioxythiophene) Nanowire Arrays

  • Cho, Bo-Ram;Sung, Myung-M.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.537-537
    • /
    • 2012
  • We have studied a fabrication of vapor phase polymerized Poly(3,4-ethylenedioxythiophene) (PEDOT) nanowire arrays for the first time. The vapor-phase polymerization (VPP) technique is a bottom-up processing method that utilizes the organic arrangement of macromolecules to easily produce ordered aggregates, including on the nanoscale, or prepare thin films of self-assembled molecules, micropatterns, or modified microstructures of pure conducting polymers. Also, liquid-bridge-mediated nanotransfer molding (LB-nTM), which was reported as a new direct patterning method recently, is for the arrayed formation of two- or three-dimensional structures with feature sizes as small as tens of nanometers over large areas up to 4 inches across and is based on the direct transfer of various materials from a mould to a substrate through a liquid bridge between them. The PEDOT nanowires grown by VPP method and transferred on a substrate to use LB-nTM method have been fabricated to single crystal PEDOT nanowires investigated Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM), Selected Area Electron Diffraction (SAED), X-Ray Diffraction (XRD), X-ray Photoelectron Spectroscopy (XPS), and electrical properties.

  • PDF

Research of Optical Design Method for Prism Luminaire (조명기구용 프리즘의 광학 설계법에 관한 연구)

  • Seok, Dae-Il;Lee, Chang-Mo;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.19-25
    • /
    • 2007
  • We studied prism design method for actual light source that have bulk in order to accomplish particular intensity distribution. When we know incidence angle and try to send ray to given direction, numerical formula that yields prism vertical angle, and then vertical angles were calculated sequentially. After analyzing problem that supposing to point light source, supplemented this and derived applicable prism design method on bulk light source. The intensity distribution and efficiency that came out by each design results were compared and analyzed, we got improved results through supplemented design method.

A Study on the Computer Simulation Estimate of Light Shelf Using Lightscape (Lightscape를 이용한 광선반의 시뮬레이션 평가 연구)

  • Cho, Yil-Sik;Kim, Ki-Se;Yoon, Jong-Ho;Lee, Jin-Sook
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.93-102
    • /
    • 2003
  • One of the promising optical daylighting systems is light shelf type daylighting system, Two types of lighting performance analysis methods are 1) Ray-Tracing method and 2) Radiosity method. The purpose of this paper is to compare two methods in terms of advantages and disadvantages by further looking at the detail algorithm. Also. model verification with Lightscape simulations has been conducted. Effectiveness of light penetration factor in terms of daylighting factor has been investigated and quantified. In summer time. the performance of the light shelf was twice better than the case without it.

Soluble Complex Formation of Rifampicin with Arginine (Rifampicin과 Arginine간의 가용성 Complex 형성에 관한 연구)

  • 김종국;신희종
    • YAKHAK HOEJI
    • /
    • v.27 no.1
    • /
    • pp.11-19
    • /
    • 1983
  • Rifampicin-arginine complex was prepared to increase the solubility and dissolution rate of rifampicin. Solvation method was applied to make the complex and its formation was identified by the solubility method, powder x-ray diffractometry, differential thermal analysis and spectroscopic determination. The complex was formed in the molar ratio of 1 : 1 which was proved by the slope ratio method and continuous variation method. The complex was a non-crystalline form determined by the x-ray powder diffractometric analysis. The solubility of complex in water was significantly higher than that of rifampicin itself. The stability constant and thermodynamical properties of the complex were determined to investigate the solubilization phenomena. The thermodynamic data showed that the complexation between rifampicin and arginine was an exothermic and spontaneous reaction. Simulated absorption studies carried out through the artificial lipid barrier in artificial gastric and intestinal juices. The results showed that the complex had an enhanced absorption rate of rifampicin nearly twice compared with that of rifampicin itself.

  • PDF

A new dead-time determination method for gamma-ray detectors using attenuation law

  • Akyurek, T.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.4093-4097
    • /
    • 2021
  • This study presents a new dead-time measurement method using the gamma attenuation law and generalized dead-time models for nuclear gamma-ray detectors. The dead-time of the NaI(Tl) detection system was obtained to validate the new dead-time determination method using very thin lead and polyethylene absorbers. Non-paralyzing dead-time was found to be 8.39 ㎲, and paralyzing dead-time was found to be 8.35 ㎲ using lead absorber for NaI(Tl) scintillator detection system. These dead-time values are consistent with the previously reported dead-time values for scintillator detection systems. The gamma build-up factor's contribution to the dead-time was neglected because a very thin material was used.

The X-Ray Fluorescent Spectrographic Analysis of Silicate Minerals (X線螢光分析에 依한 珪酸鹽鑛物의 分析)

  • Chan Kuk Kim;Ki Nam Sang;Hwang Am Kim
    • Journal of the Korean Chemical Society
    • /
    • v.13 no.1
    • /
    • pp.49-55
    • /
    • 1969
  • X-ray Fluorescence Spectrographic method has been applied for the rapid determination of main components, such as $SiO_2$, $Al_2O_3$, $Fe_2O_3$, CaO, MgO and $K_2O$ in Silicate Minerals. In this method, Boric Acid was used as a binder after fusion with Lithium Tetraborate in the briquet-making process. The Lithium Flubride, Ammonium di-Hydrogen Phosphate and Ethylene Diamine d-Tartrate crystals were used with Scintillation counter and Gas Flow counter as the detectors. Several influences on this method were discussed, including the particle size of samples and reducing of the matrix effects by dilution with Boric Acid and addition of Lanthanum Oxide with the diluent. In order to test the reproducibility of this method described above, the determination of the same kind of samples were carried out repeatedly, and the results obtained were presented in the table. Calibration curves for each element were presented, and the application of the method was tested with International Rock Standard T-Ⅰ. All the results obtained by X-Ray Fluorescence Spectrographic method were compared with the results by conventional chemical method.

  • PDF