• Title/Summary/Keyword: Ray Method

Search Result 5,500, Processing Time 0.035 seconds

The Evaluation of the Thick Polycrystalline HgO and PbO Films Derived by Particle Sedimentation Method for the Mammographic Application (입자침전법을 이용한 다결정 산화수은과 산화납 필름의 방사선 유방촬영 장치 적용성 평가)

  • Noh, Si-Cheol;Park, Ji-Koon;Choi, Il-Hong;Jung, Hyoung-Jin;Kang, Sang-Sik;Jung, Bong-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.429-433
    • /
    • 2014
  • In this study, the morphology and the x-ray quantum efficient of mercury oxide (HgO) and lead oxide (PbO) sensors derived by particle sedimentation method were discussed. In the pursuit of this purpose, we investigated the electrical characteristics and the x-ray quantum efficiency of various thicknesses of HgO and PbO films in mammographic x-ray energy. We have therefore developed a particle-in-binder sedimentation method of fabricating large area polycrystalline films onto transparent glass substrates coated with indium tin oxide. We are currently optimizing the growth method to improve the quantum efficiency with the ultimate goal of obtaining as quantum efficiency close to that of single crystal performance. Our future efforts will concentrate on optimization of large area film growth techniques specifically for deposition on a-Si:H flat panel readout arrays.

The Assessment of Tube Incidence Angle for Minimizing the Patellofemoral Joint Overlap Distance in Merchant View (Merchant 검사 시 슬개대퇴관절 겹침 최소화를 위한 중심 X선 입사각에 대한 평가)

  • Ko, Ye-Weon;Joo, Young-Cheol;Kim, Min-suk;Go, Yu-Rim
    • Journal of radiological science and technology
    • /
    • v.43 no.3
    • /
    • pp.161-167
    • /
    • 2020
  • This study aimed to found out the effect of patellofemoral overlap distance by changing femur thickness and center X-ray angles in Merchant method images. Based on the femur thickness, it suggested tube angle minimizes overlap. It was conducted by Merchant method, a knee tangential view, and the image was obtained by changing the thigh thickness from 14 to 20 cm and the center ray angle from 60°, 57°, 55°. The images were measured by five researchers using a method of measuring the overlap, which was designed by them. The results showed at 60°, 57°, 55° angle, the patellofemoral overlap distance resulted in 0.47±0.66 to 20.89±0.65 cm, 2.26±0.28 to 15.73±0.62 cm, 1.39 ± 0.83 to 12.49 ± 0.37 cm. However, for 57° and 55°, no overlap in thickness under 14.5 and 14 to 15.5 didn't appear. it showed high correlation between femur thickness and overlap. The difference in the mean value of overlap in each group showed a statistically significant difference (p<0.01), all were classified as independent groups in the post-hoc test. In all images, the patellofemoral overlap distance increased as the thickness increased, and at the average thickness of Korean men and women, overlap decreased when reducing center ray. When conducting Merchant tests on Koreans, it was suggested it would be useful to use 57° angle because it minimize the effects of overlap and intrusions of tibia.

X-Ray Fluorescence Analysis of $Ta_2O_5,\;Nb_2O_5$ and ZrO_2$ in Tin-Slag Samples using Simple Dilution Method (주석 슬랙중 $Ta_2O_5,\;Nb_2O_5$ZrO_2$의 단일희석법을 이용한 X-선 형광분석)

  • Young-Sang Kim;Hak Je Sung
    • Journal of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.293-301
    • /
    • 1984
  • -ray fluorescence analysis of $Ta_2O_5$, $Nb_2O_5$ and $ZrO_2$ in tin-slag samples using the simple dilution method was studied. The method is to correct mathematically the calibration curve to the linear line by the dilution. One synthesized standard having similar composition to the sample and tin slag samples were diluted with anhydrous $Li_2B_4O_7$ at the level of 1%, 2% and 3% of the sample content respectively. The diluted samples were fused at $1150^{\circ}C$ for 30 minutes and these glass beads were finely ground and pelletized. Measuring the X-ray intensities with these pellets, analytical results were calculated by the equation derived from J. Scherman's equation for the characteristic X-ray intensity of an element. Analytical results agreed with the reference values obtained by the standard calibration method within allowable error range and were reproducible.

  • PDF

Source Independent Subtree Ray Tracing Method for Wave Propagation Simulation in Urban Environment (도심 환경에서 전파 특성 모의 해석을 위한 신호 독립 부트리 방법에 대한 연구)

  • Kwon, Se-Woong;Moon, Hyun-Wook;Oh, Jae-Rim;Yoon, Young-Joong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.3
    • /
    • pp.301-306
    • /
    • 2010
  • In this paper, a SIT(Source Independent Tree) method for ray tracing is proposed to enhance the efficiency of tree construction with reuse of sub tree in urban environment, As the SIT method is applied, the decrease of the number of nodes for picocell and microcell simulations is 100 times. And 88~98 % of the total nodes are reused with change of location of signal source from an analysis of node reuse efficiency. Therefore the proposed SIT method is useful in performance enhancement of ray tracing, especially, for multiple antenna simulation like as MIMO system and cell planning.

Evaluation of Daylighting Performance and Design of a Curved-Lightshelf by the Ray Tracing Method (광선추적기법을 활용한 곡면형 광선반시스템 설계 및 채광성능 평가)

  • Kim, Dong-Su;Yoon, Jong-Ho;Shin, Woo-Chul;Lee, Kwang-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.136-141
    • /
    • 2011
  • The lightshelf system reduces intense illumination levels of indoor from direct sun light and reflect to lead diffused light into indoor deeply. This study aims to design acurved-lightshelf by a ray tracing method and evaluate the daylighting performance of window integrated with the curved-lightshelf by computer simulations. For this purpose, evaluation test model was designed for the experiments to validate the simulation model, and the curved-lightshelf was designed by the ray tracing method using Ecotect. After the office model was designed using 3D simulation, the average indoor illuminance, luminance and distribution of illuminance were evaluated by simulation which has a algorithm of Radiosity and Ray-Tracing method under four different cases(case1;no lightshelf, case2; Flat board, case3; tilted at $30^{\circ}$ angle, case4; the curved-lightshelf). As results, it turns out that case1 showed higher average illuminance and case4 was more uniformly distributed than case2 and case3, In addition average luminance of case1 was also lower. indicating that the curved-lightshelf would reduce the possibility of the glare, while maintaining the sufficient daylight level.

A grid-line suppression technique based on the nonsubsampled contourlet transform in digital radiography

  • Namwoo Kim;Taeyoung Um;Hyun Tae Leem;Bon Tack Koo;Kyuseok Kim;Kyu Bom Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.655-668
    • /
    • 2023
  • In radiography, an antiscatter grid is a well-known device for eliminating unexpected x-ray scatter. We investigate a new stationary grid artifact suppression method based on a nonsubsampled contourlet transform (NSCT) incorporated with Gaussian band-pass filtering. The proposed method has an advantage that extracts the Moiré components while minimizing the loss of image information and apply the prior information of Moiré component positions in multi-decomposition sub-band images. We implemented the proposed algorithm and performed a simulation and an experiment to demonstrate its viability. We did this experiment using an x-ray tube (M-113T, Varian, focal spot size: 0.1 mm), a flat-panel detector (ROSE-M Sensor, Aspenstate, pixel dimension: 3032 × 3800 pixels, pixel size: 0.076 mm), and carbon graphite-interspaced grids (JPI Healthcare, 18 cm × 24 cm, line density: 103 LP/inch and 150 LP/inch, ratio: 5:1, focal distance: 65 cm). Our results indicate that the proposed method successfully suppressed grid artifacts by reducing them without either reducing the spatial resolution or causing negative side effects. Consequently, we anticipate that the proposed method can improve image acquisition in a stationary grid x-ray system as well as in extended x-ray imaging.

Fabrication of Single Crystal Poly (3,4-ethylenedioxythiophene) Nanowire Arrays by Vapor Phase Polymerization with Liquid-bridge-mediated Nanotransfer Molding

  • Lee, Gi-Seok;Jo, Bo-Ram;Seong, Myeong-Mo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.372-372
    • /
    • 2012
  • We have studied a fabrication of Poly (3,4-ethylenedioxythiophene) (PEDOT) wire arrays and structures with various feature sizes from hundreds micrometers to tens nanometers. PEDOT is well-known as a conducting material, can be grown by a vapor pressure polymerization (VPP) method. The VPP technique is a bottom-up processing method that utilizes the organic arrangement of macromolecules to easily produce ordered aggregates. Also, liquid-bridge-mediated nanotransfer molding (LB-nTM), which was reported as a new direct patterning method recently, is based on the direct transfer of various materials from a mould to a substrate through a liquid bridge between them. The PEDOT nanowires grown by VPP method and transferred on a substrate to use LB-nTM method have been investigated by Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM), Selected Area Electron Diffraction (SAED), X-Ray Diffraction (XRD), X-ray Photoelectron Spectroscopy (XPS), and electrical properties.

  • PDF

Analytical Method for Determining the Degree of Wave Refraction (파랑의 굴절 정도를 예측하는 해석기법)

  • Jung, Tae-Hwa;Lee, Changhoon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.30 no.5
    • /
    • pp.217-222
    • /
    • 2018
  • An analytical method for determining the degree of wave refraction is investigated. The ray tracing method previously used to calculate wave propagating cannot explain the degree of refraction caused by different kinds of conditions. In this study, we suggest the index of refraction degree using the principle that refraction is caused by the difference of phase velocities along the crest line.

A New Approach in Sensitometry of X-ray Film to Use Aluminium Stepwedge (알루미늄계단을 이용한 X선필름의 감도측정법에 관한 새로운 시도)

  • Huh, Joon;Kim, Chang-Kyun;Kang, Hong-Sook;Lee, Sun-Sook
    • Journal of radiological science and technology
    • /
    • v.6 no.1
    • /
    • pp.35-41
    • /
    • 1983
  • Boot-Strap method is used to measure the sensitivity of X-ray film, but it is too complicated to design the plot and this method is generally a falling-off in the accuracy and the reproducibility. Authors made an attempt a new method to obtain the stable H-D curve, that is to say; Boot-Strap method used in combination with distance-change method, and the accuracy and the reproducibility.

  • PDF

Determination of Optical Constants of Thin Films in Extreme Ultraviolet Wavelength Region by an Indirect Optical Method

  • Kang, Hee Young;Lim, Jai Dong;Peranantham, Pazhanisami;HwangBo, Chang Kwon
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.38-43
    • /
    • 2013
  • In this study, we propose a simple and indirect method to determine the optical constants of Mo and ITO thin films in the extreme ultraviolet (EUV) wavelength region by using X-ray reflectometry (XRR) and Rutherford backscattering spectrometry (RBS). Mo and ITO films were deposited on silicon substrates by using an RF magnetron sputtering method. The density and the composition of the deposited films were evaluated from the XRR and RBS analysis, respectively and then the optical constants of the Mo and ITO films were determined by an indirect optical method. The results suggest that the indirect method by using the XRR and RBS analysis will be useful to search for suitable high absorbing EUVL mask material quickly.