• Title/Summary/Keyword: Ray Method

Search Result 5,505, Processing Time 0.035 seconds

Discrete Ray Tracing Techniques for Wave Propagation Characteristic of Random Rough Surfaces (불규칙 조면의 전파 특성 해석을 위한 이산 광선 추적법)

  • Yoon, Kwang-Yeol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.3
    • /
    • pp.233-238
    • /
    • 2010
  • In this paper, we have proposed discrete ray tracing method (DRTM) for numerical analysis of characteristics of electromagnetic propagation along 2D random rough surfaces. The point of the present method is to discretize not only rough surface but also ray tracing. The former helps saving computer memories and the latter does simplifying ray searching algorithm resulting in saving computation time. Numerical calculations are carried out for 2D random rough surfaces, and electric field distributions are shown to check the effectiveness of the proposed DRTM.

A Development of Fast Speed Monte-Carlo Ray Tracing Method and Study of the Characteristics of an Absolute Reflectometer (연산 속도가 개선된 몬테카를로 광선 추적 알고리즘 개발 및 이를 활용한 절대 반사율 측정 장치 특성 분석에 관한 연구)

  • Kim, Han-Pil;Byun, Seok-Joo;Jeon, Min Yong;Park, Jong-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.7-14
    • /
    • 2014
  • We proposed a new algorithm to improve the calculation speed of forward ray tracing method which was quite a problem in conventional Monte Carlo algorithm. To verify the accuracy and the effect of improving calculation speed, we directly compared integrating sphere characteristics with conventional ray tracing algorithm under the same condition which was referred in a reference paper. By applying new algorithm to an absolute reflectometer, we calculated the degree of errors which were caused by baffle and port characteristics to find optimal system design condition.

Analysis of efficiency of X-ray equipment for medical service (의료용 X-ray 기기의 성능평가)

  • Kim, Tae-Gon;Kim, Toung-Pyo;Lee, Ho-Sic;Park, Yong-Pil;Cheon, Min-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.426-426
    • /
    • 2009
  • Diagnostic X-ray system is general and basic medical equipment to be used in mostly medical organizations, but being bombed of radioactivity is a big weak point when irradiates a X-ray to the human body so that ICRP restricted the radiation exposure tolerance of the human body. In order to reduce being bombed, the many research and development is now advanced. A lots of diagnostic X-ray machines have currently used due to the increase of occurrence efficiency of X-ray and precisely the output control by using the inverter which is a high speed switching semiconductors. For getting the confidence of the X-ray machine, the same radiation occurrence, same evaluation, and same irradiation condition are necessary when evaluates X-ray irradiation. It is the most important part for the accuracy of the test result and the patient safety. This paper has produced the high voltage occurrence system of full-wave rectification method by using the LC resonance inverter, and evaluated the irradiation reproducibility in order to use it in diagnosis of the patient.

  • PDF

A Study on the Image Quality and the Scattered Ray content in the Skull Radiography (두부(頭部) X선촬영시(線撮影時) 산란선(散亂線)과 화질(畵質)에 관(關)한 검토(檢討))

  • Huh, Joon;Kim, Chang-Kyun;Kang, Hong-Seok;Lee, Sun-Sook;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.15-19
    • /
    • 1985
  • The seattered-ray have a bad effect to the image of x-ray film. Therefore, to obtain the better x-ray image, the most important point is to eliminate the scattered-ray, come from the patient, and the easiest method to eliminate the scattered-ray is to use a proper grid for tube voltages. Authors made an experiment on the scattered-ray contents and the image quality in skull radiography, and obtained the results as follows; 1. The scattered-ray content in skull radiography was 83%, but it could be reduced to 35%-50% by using grid. 2. The image contrast was most increased when the using grid ratio was 8:1. 3. The image quality was not influenced by the scattered-ray contents between 32% and 45%.

  • PDF

Study of n/γ discrimination using 3He proportional chamber in high gamma-ray fields

  • Choi, Joonbum;Park, Junesic;Son, Jaebum;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.263-268
    • /
    • 2019
  • The $^3He$ proportional chamber is widely used for neutron measurement owing to its high neutron detection efficiency and simplicity for gamma-ray rejection. In general, the neutron and gamma-ray signals obtained from the $^3He$ proportional chamber can be easily separated by the difference in the pulse heights. However, for a high gamma-ray field, the gamma-ray signal cannot be precisely eliminated by the pulse height due to gamma-ray pulse pileup which causes the pulse height of gamma-ray pulse to increase and making the pulses due to neutrons and gamma rays indistinguishable. In this study, an improved algorithm for $n/{\gamma}$ discrimination using a parameter, which is the ratio of the rise time to the pulse height, is proposed. The $n/{\gamma}$ discrimination performance of the algorithm is evaluated by applying it to $^{252}Cf$ neutron signal separation from various gamma-ray exposure rate levels ranging 0.1-5 R/h. The performance is compared to that of the conventional pulse-height analysis method in terms of the gamma elimination ratio. The suggested algorithm shows better performance than the conventional one by 1.7% (at 0.1 R/h) to 70% (at 5 R/h) for gamma elimination.

The study for electric readout of X-ray signal using MOSFET (MOSFET를 이용한 X선 신호의 전기적 획득에 관한 연구)

  • Park, S.K.;Kang, Y.S.;Seo, J.H.;Park, J.K.;Nam, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.295-296
    • /
    • 1998
  • With xeroradiography appearance, DR (Digital Radiography) system have been studying for X-ray detection using photoreceptor. Also detection method for receptor charge change have been developing variably. We use photoreceptor material of a-Se(Amorphous Selenium) with high DQE, high SNR(Signal to Noise Ratio) and high transformation efficiency of X-ray signals into electrical signals. After a-Se receptor is uniformly charged by using Arc discharge, X-ray is exposed. Then a-Se receptor produce subtle charge variation and MOSFET detect charge variations. The detected signal pass A/D converter and signal processing by PC. As results, the initial voltage is 8V. It has wide dynamic range needed digital radiography system. In this study, we obtained data with changing kVp(tube potential voltage) and fixed 8mAs(tube current by exposure time) in X-ray system. However MOSFET detector for X-ray signal is not tested X-ray mAs variations. But if MOSFET detector is tested X-ray mAs variation and exactly calibrated multichannel is made and noise-reduction is done, suitable DR system readout method will be done.

  • PDF

Comparison of Output and Radiation Quality of X-rays according to the Full-Wave Rectification Method and Dual-Voltage Rectification Method of an X-ray Generator (X선 고전압장치의 전파 및 배전압 정류방식에 따른 X선 출력 및 선질 비교)

  • Kim, Tae-Gon;Cheon, Min-Woo;Park, Yong-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.7
    • /
    • pp.534-538
    • /
    • 2010
  • X-ray systems for medical treatment use noninvasive procedures. Being capable of locally inspecting the inside of the body, X-ray systems are routinely used for basic diagnosis. X-ray systems to be used for medical purposes were originally made with a gas filled tube inside an induction coil in the initial stages of development but with this approach it becomes difficult to take a satisfactory picture through thick body sections, non invasively. However continued development made it possible to take non-invasive pictures of breasts, blood vessels and other body parts through thick body sections. Recently, high-voltage X-ray generators of more compact size, increased generation efficiency, and sophisticated output control have become possible. All of these features are made possible by the use of a high-frequency output from an inverter and a fast switching semiconductor device. In this paper, we describe a new X-ray generator operating with a resonant inverter in order to reduce switching loss and high frequency noise. In addition, in order to identify the differences amongst types of rectification, we have compared output and the quality of X-ray pictures obtained with full-wave rectification and dual-voltage rectification methods.

Genetic Relationship of Mono-cotyledonous Model Plant by Ionizing Irradiation (단자엽 모델 식물의 방사선원 별 처리에 따른 유전적 다형성 분석)

  • Song, Mira;Kim, Sun-Hee;Jang, Duk-Soo;Kang, Si-Yong;Kim, Jin-Baek;Kim, Sang Hoon;Ha, Bo-Keun;Kim, Dong Sub
    • Journal of Radiation Industry
    • /
    • v.6 no.1
    • /
    • pp.23-29
    • /
    • 2012
  • In this study, we investigated the genetic variation in the general of monocot model plant (rice) in response to various ionizing irradiations including gamma-ray, ion beam and cosmic-ray. The non-irradiated and three irradiated (200 Gy of gamma-ray and 40 Gy of ion beam and cosmic-ray) plants were analyzed by AFLP technique using capillary electrophoresis with ABI3130xl genetic analyzer. The 29 primer combinations tested produced polymorphism results showing a total of 2,238 bands with fragments sizes ranged from 30 bp to 600 bp. The number of polymorphism generated by each primer combinations was varied significantly, ranging from 2 (M-CAC/E-ACG) to 158 (M-CAT/E-AGG) with an average of 77 bands. Polymorphic peaks were detected as 1,269 with an average of 44 per primer combinations. By UPGMA (Unweighted Pair Group Method using Arithmetic clustering) analysis method, the clusters were divided into non-irradiated sample and three irradiated samples at a similarity coefficient of 0.41 and three irradiation samples was subdivided into cosmic-ray and two irradiation samples (200 Gy of gamma-ray and 40 Gy of ion beam) at similarity coefficient of 0.48. Similarity coefficient values ranged from 0.41 to 0.55.

An Effective Extraction Algorithm of Pulmonary Regions Using Intensity-level Maps in Chest X-ray Images (흉부 X-ray 영상에서의 명암 레벨지도를 이용한 효과적인 폐 영역 추출 알고리즘)

  • Jang, Geun-Ho;Park, Ho-Hyun;Lee, Seok-Lyong;Kim, Deok-Hwan;Lim, Myung-Kwan
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.7
    • /
    • pp.1062-1075
    • /
    • 2010
  • In the medical image application the difference of intensity is widely used for the image segmentation and feature extraction, and a well known method is the threshold technique that determines a threshold value and generates a binary image based on the threshold. A frequently-used threshold technique is the Otsu algorithm that provides efficient processing and effective selection criterion for choosing the threshold value. However, we cannot get good segmentation results by applying the Otsu algorithm to chest X-ray images. It is because there are various organic structures around lung regions such as ribs and blood vessels, causing unclear distribution of intensity levels. To overcome the ambiguity, we propose in this paper an effective algorithm to extract pulmonary regions that utilizes the Otsu algorithm after removing the background of an X-ray image, constructs intensity-level maps, and uses them for segmenting the X-ray image. To verify the effectiveness of our method, we compared it with the existing 1-dimensional and 2-dimensional Otsu algorithms, and also the results by expert's naked eyes. The experimental result showed that our method achieved the more accurate extraction of pulmonary regions compared to the Otsu methods and showed the similar result as the naked eye's one.

Development of Indirect Dosimetry by Calculation Method in the Diagnostic X-ray Equipment (진단용엑스선촬영장치의 간접 선량 계산법 개발)

  • Kim, Jung-Su;Kim, Sung-Hwan;Jeon, Min-Cheol;Ju, Won-Ha;Jeong, Min-Gyu;Kim, Mi-Jeong;Lee, Seung-Youl;Lee, Tae-Hee;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.587-594
    • /
    • 2018
  • The purpose of this study was to develop the indirect dosimetry by calculation (IDC) method for diagnostic X-ray equipment. The experiments were performed with inverter type X-ray tubes: Toshiba (E7252X, Japan) and Varian (RAD-14, USA). For the development method, we first applied the standard quality of X-ray beam shown in the TRS457 document, and second, to produce the constants of trendline for the IDC, the total filtration on X-ray beam was subdivided. Third, in order to increase the precision, the energy region was divided into the high energy region and the low energy region and developed by the IDC. In order to verify the IDC, mean dose (mR) values were measured for three Toshiba X-ray tubes and three Varian X-ray tubes at clinical medical institutions and then compared with the IDC on the 2013. As a result, compared with the previous study, the accuracy of the IDC of this study were improved by 2.71% and 9.91% in Toshiba and Varian X-ray tubes, respectively.