• 제목/요약/키워드: Raw Water Turbidity

검색결과 144건 처리시간 0.022초

고탁도시 소석회 투입방법에 따른 정수장 응집제의 효율 평가 (The Estimation of the Coagulant on Method of Lime Input in the Water Treatment Plant at High Turbidity)

  • 방미란;임봉수;배병욱
    • 상하수도학회지
    • /
    • 제12권3호
    • /
    • pp.107-117
    • /
    • 1998
  • In order to removal turbidity at high turbidity, this study was carried to evaluate the coagulants(Alum, PACl, PACS) that was suited the characteristics of raw water in water treatment plants and to determinate the optimum method of lime feed. When the optimum coagulant was selected the organic matter removal was also investigated as $UV_{254}$. PACl, lime first feed had the highest turbidity removal efficiency rate as above 99.1% and then $UV_{254}$ removal rate was obtained over than 88.0%. If you had the necessary of the lime feed, among the method of lime feed time interval feed largely was improved than simultaneous feed. Also, lime feed dose had about 1/5 of coagulants dose in case of Alum and PACl, but always PACS should be considerated lime dose.

  • PDF

Polyamine 고분자 응집제의 합성과 상수처리의 적용 (The Synthesis of Polyamine Polymeric Flocculant and Application of Drinking Water Treatment.)

  • 신명철;최상준
    • 한국환경과학회지
    • /
    • 제7권3호
    • /
    • pp.409-413
    • /
    • 1998
  • Polyamine was synthesized for the drinking water treatment. Polyamine was produced by the two step polycondensation of dimethytamine(DMA) and epichlorohydrin(EPI) and its properties were characterized. The effects of mole ratio of (DMA1/1EPl), reaction temperature and reaction time on synthesis of polyamine were investigated. Polyamine flocculant was applied to Nak-dong river raw water to examine its efficiency in reducing turbidity. The synthesized polyamine was effective as flocculant for drinking water treatment. The addition of 1 mg/L of polyamlne flocculant caused the reduction of 50% PAC (polyaluminium chloride).

  • PDF

낙동강 상수원수의 오존처리 효과 I. 회분식 오존처리에 의한 수처리효과 (Effect of Ozone Treatment for Nakdong River Raw Water I. Efficiency of Water Treatment by Conducting Batch Test of Ozonation Experiments)

  • 조주식;임영성;이홍재;허종수
    • 한국환경과학회지
    • /
    • 제10권6호
    • /
    • pp.393-399
    • /
    • 2001
  • This study was carried out to evaluate the pollutant removal efficiencies of the advanced drinking water treatment using ozonation. for raw water, Nakdong River was used. By conducting batch ozonation test, the following results were obtained. when ozone dosage of 5mg/$\ell$was used, preozonation of raw water reduced turbidity, KMnO$_4$consumption, DOC(dissolved organic carbon), UV254 absorbance, THMFP(trihalomethane formation potential) as much as 3.9NTU, 5.5mg/$\ell$, 1.15mg/$\ell$, 0.112 and 0.065mg/$\ell$, respectively. In case of postozonation of sand filtered water, water quality was also improved with decrease in turbidity, KMnO$_4$consumption, DOC, UV254 absorbance and THMFP at the amount of 0.08NTU, 2.6mg/$\ell$, 0.88mg/$\ell$, 0.042 and 0.018mg/$\ell$, respectively. On the other hand, contents of dissolved oxygen increased at the level of 1.3mg/$\ell$ after preozonation process and 1.0mg/$\ell$ after postozonation process. The effect of ozone dosage was higher than that of its contact time for the removal of the pollutants.

  • PDF

의사결정 알고리즘을 이용한 DAF 공정 제어에 관한 연구 (A study on dissolved air flotation (DAF) process control using decision algorithm)

  • 정우식;안주석;박지영;오현제
    • 상하수도학회지
    • /
    • 제31권5호
    • /
    • pp.409-414
    • /
    • 2017
  • In this study, we divided the process operation scenarios into three categories based on raw water temperature and turbidity. We will select and operate the process operation scenario according to the characteristics of the raw water. The number of algae in the DAF treated water has been analyzed to be less than 100 cells/mL. These results indicated that the DAF process is effective in removing the algae. In addition, the scenario of the integrated management decision algorithm of the DAF process was developed. DAF pilot plants ($500m^3/day$) process has shown a constantly sound performance for the treatment of raw water, yielding a significantly low level of turbidity (DAF treated water, 0.21~1.56 NTU).

정수장 응집혼화공정에서의 응집플럭 연속 모니터링 (On-line Monitoring of the Flocs in Mixing Zone using iPDA in the Drinking Water Treatment Plant)

  • 가길현;장현성;김영범;곽종운
    • 대한환경공학회지
    • /
    • 제31권4호
    • /
    • pp.263-271
    • /
    • 2009
  • 본 연구는 Y 정수장 혼화지의 응집효율을 향상시킬 목적으로 혼화지에서 생성되는 플럭을 실시간 온라인으로 평가하였다. 플럭크기를 평가하는 장비로는 온라인으로 플럭을 연속적으로 평가할 수 있는 응집플럭성장측정장치(iPDA)를 사용하였다. 플럭크기를 평가하기 위해 유기고분자 응집제인 폴리아민, 무기응집제 주입량, 원수의 탁도, pH같은 여러 가지 인자를 변수로 적용하였다. 현장실험 기간 동안 사용된 응집제는 폴리염화알루미늄(PACl)이었고, 응집보조재로 폴리아민이 사용되었다. 현장 테스트 기간 동안 원수의 탁도는 25~140 NTU 범위, pH는 7~9이었다. 원수의 탁도가 증가할수록 생성되는 플럭의 크기도 증가 하여 침전속도에 영향을 미쳤다. 회귀선분석으로 부터 FSI (Floc size index)와 탁도 T 값과의 관계식을 다음과 같이 얻었다. FSI = 0.9388logT - 0.3214 ($R^2$ = 0.8040, T : Turbidity) 또한 보조제로 사용된 폴리아민도 플럭크기값에 큰 영향을 주었고, 색도제거제로 사용된 활성탄(PAC)도 그 자체 입자로 작용하여 응집플럭크기 값에 영향을 상당히 주는 것으로 나타났다. 고탁도인 경우 FSI는 [PACl]과 [PAC]함수로 다음과 같은 식을 유도할 수 있었으며 $R^2$ = 0.9050이었다. FSI = $0.0407[T]^{0.324}[PACI]^{0.769}[PAC]^{0.178}$ [PACl] = PACl 주입농도, [PAC] = 활성탄 주입농도 상대적 응집속도 ${\Delta}FST/{\Delta}T$ 값은 응집제의 주입량보다는 활성탄의 주입량이 더 큰 영향을 주었다. 본 연구과정에서 활성탄주입량이 응집속도에 미치는 영향은 응집제의 주입농도가 미치는 것보다 ${\Delta}FST/{\Delta}T$ 값이 1.41 배 큰 것으로 나타났다. 본 연구에서 연구한 결과 플럭크기값 FSI는 여러 가지 영향인자에 상당한 영향을 받는 것으로 분석되었고, 집혼화 효율향상에 유익한 데이터를 얻을 수 있었다.

A STUDY OF SIMULATION AND CONTROL OF PAC COSING PROCESS IN WATER PURIFICATION SYSTEM

  • Nahm, Euisuck;Lee, Subum;Woo, Kwangbang;Han, Taehan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.75-78
    • /
    • 1995
  • In this paper it is concerned to develop control method using jar-test results in order to predict the optimum dosage of coaglant, PAC(PoliAluminum Chloride). Considering the relations with the reactions with the reaction of coagulation and flocculation, the five independent variables ( e, g, turbidity of raw water, water turbidity in flocculators, temperature, pH, and alkalynity) are selected out of parameters and they are put into calculation to develop a neural network model for PAC dosing process in water purification system. This model is utilized to predict optimum dosage of PAC. That is, the optimum dosage of PAC is searched in neural network model for PAC dosing process to minimize the water turbidity in flocculators. This searching is implemented by means of expert heuristics. The efficacy of the proposed contorl schemem and feasibility of acquired neural network model for PAC dosing contorl in water purification system is evaluated by means of computer simulation.

  • PDF

Automatic Control on Dosing Coagulant as to Stream Current

  • Oh, Sueg-Young;Byun, Doo-Gyoon;Hwang, Jae-Moon;Song, Hyun-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1318-1321
    • /
    • 2005
  • As recently raw water quality has been polluted as well as its quality has been remarkably varied according to season and region, the precise control of coagulant dosage is being keenly required in water treatment plants. The amount of coagulant is closely related to raw water quality such as turbidity, alkalinity, water temperature, pH, electrical conductivity, etc. Since the optimum quantity of chemicals is not yet finalized, so dosage rate must be decided by using jar test that takes one or two hours. Hereupon, the output signal of stream current and multi-regression on historical data were proposed to be applied to the coagulant dosing control. In consequence of applying the scheme to automatic determination of the dosage rate, it was testified that the determination of dosage rate was very effective in case it is performed as to real-time sensing of water quality and the output signal of stream current.

  • PDF

Fabrication and Characterization of Onggi Filter for Appropriate Water Treatment Technology

  • Park, Joon-Hong;Kim, Jin-Ho;Cho, Woo-Seok;Han, Kyu-Sung;Hwang, Kwang-Taek
    • 한국세라믹학회지
    • /
    • 제54권2호
    • /
    • pp.114-120
    • /
    • 2017
  • In underdeveloped countries, many people suffer from water shortage due to the absence of water supply service. Although water purifiers have provided support in such situations, it is not easy to maintain water filters without a continuous supply of consumable filters. To obtain a sustainable drinking water source, appropriate technology of water treatment is necessary. Herein, a low cost water purification system was developed using natural raw materials. A non-electric water treatment system was developed using filtration through an Onggi filter, which is a type of Korean traditional earthenware with a microporous surface. The porosity and flux of the prepared Onggi filter were 29.06% and 31.63 LMH, respectively. After purification of water with total dissolved solids of 10.4 mg/L and turbidity of 100 NTU, the total dissolved solids and turbidity of the water treated using the Onggi filter decreased by 12% and 99.8%, respectively.

ENHANCED REMOVAL OF RESIDUAL ALUMINUM AND TURBIDITY IN TREATED WATER USING POLYMERS

  • Kim, Seung-Hyun
    • Environmental Engineering Research
    • /
    • 제10권4호
    • /
    • pp.155-164
    • /
    • 2005
  • This study investigated the possibility of reducing the residual aluminum (Al) in the treated water using polymers. Two raw waters (lake and river water) and three kinds of polymers (coagulant, flocculant, and filtration aids) were used for this purpose. This study found that coagulation at the high dose did not necessarily lead to the high concentration of the residual Al in the treated water. The coagulation efficacy was found more important in determining the residual Al than the coagulant dose. The use of a polymer enhanced the removal of turbidity as well as the residual Al. The coagulant aid removed the dissolved Al as well as the particulate Al by helping the coagulation and the solid-liquid separation. The flocculant aid and the filtration aid preferentially removed the particulate Al while helping the solid-liquid separation. The filtration aid reduced the residual Al substantially more effectively than the flocculant aid. The polyamine-based coagulant aid (FL) showed the better performance in reducing the residual Al and turbidity than DADMAC (WT). The cationic flocculant aid with weak charge density and the medium molecular weight (SC-020) showed the best performance in reducing the residual Al.

정밀여과·나노여과·역삼투 막에 의한 세슘과 요오드의 제거 (Removal of cesium(137Cs) and iodide(127I) by microfiltration·nanofiltration·reverese osmosis membranes)

  • 채선하;김충환
    • 상하수도학회지
    • /
    • 제28권5호
    • /
    • pp.549-554
    • /
    • 2014
  • This study was evaluated the applicability of the membrane filtration process (Micro Filtration (MF), nanofiltration membranes (NF), reverse osmosis (RO)) on the major radioactive substances, iodine ($I^-$) and cesium ($Cs^+$) using membranes produced in Korea and domestic raw water. Iodine ($I^-$) or cesium ($Cs^+$) in the microfiltration membrane (MF) process could not be expected removal efficiency by eliminating marginally at the combined state with colloidal and turbidity material. At the domestic raw water (lake water, turbidity 1.2 NTU, DOC 1.3 mg/L) conditions, nanofiltration membrane (NF) and reverse osmosis (RO) showed a high removal rate of about 88 ~ 99% for iodine ($I^-$) and cesium ($Cs^+$) and likely to be an alternative process for the removal of radioactive material.