• 제목/요약/키워드: Raw Water Pipe

검색결과 27건 처리시간 0.023초

원전 배관의 반복 측정 데이터에 대한 신뢰도 분석 방법 (Reliability Analysis Method for Repeated UT Measurement Data in Nuclear Power Plants)

  • 윤훈;황경모
    • Corrosion Science and Technology
    • /
    • 제12권3호
    • /
    • pp.142-148
    • /
    • 2013
  • Safety is a major concern in Nuclear Power Plants (NPPs). Piping systems in NPPs are very complex and composed of many components such as tees, elbows, expanders and straight pipes. The high pressure and high temperature water flows inside piping components. As high speed water flows inside piping, the pipe wall thinning occurs in various reasons such as FAC (Flow Accelerated Corrosion), LDIE (Liquid Droplet Impingement Erosion) and Flashing. To inspect the wall thinning phenomenon and protect the piping from damages, piping components are checked by UT measurement in every overhaul. During every overhaul, approximately 200~300 components (40,000~60,000 UT data) are examined in NPPs. There are some methods from EPRI for evaluating wear rate of components. However, only few studies have been conducted to find out the raw data reliability for the wear rate evaluation. Securing the reliable raw data is the key factor for a reasonable evaluation. This paper suggests the reliability analysis method for the repeatedly measured data for wear rate evaluation.

생하수의 퍼클로레이트 생분해 특성 (Bioreduction Characteristics of Perchlorate in Raw Sewage)

  • 홍성환;최혁순
    • 한국수처리학회지
    • /
    • 제26권6호
    • /
    • pp.81-87
    • /
    • 2018
  • This research was done to investigate the bioreduction characteristics of perchlorate in raw sewage because sewage contains biodegradable organics and various microorganisms for biological perchlorate reduction. Two different types of sewage were tested for biological perchlorate reduction in the flasks. Sewage A was collected from the screening equipment and sewage B was collected from the primary settlement in the municipal wastewater treatment facilities. Perchlorate was completely reduced within 72hours from 8.2 and 10.4 mg/L in the sewage A and sewage B flask tests. When perchlorate and nitrate were added in sewage A, both perchlorate and nitrate were reduced. However, perchlorate and nitrate removal rates were 9.3% and 64.0% at 72hours in sewage B. Perchlorate reduction was significantly inhibited by high salinity(0.5% NaCl) in the sewage A and B. These results showed the sewage has potential for the biological perchlorate reduction in the sewage pipe.

GMR 공사에 적용된 PCCP(EC)의 설계 (PCCR(ECCP) Design of Great Man-made River Project)

  • 김영수;최인식;신경수;김두영;이원재
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표대회 논문집(III)
    • /
    • pp.686-693
    • /
    • 1998
  • Prestressed Concrete Cylinder Pipe(PCCP) is used in water transmission pipeline of the Great Man-made River Project(GMR Project). In domestic area, PCCP is used for water cooling systems of Uljin and Youngkwang nuclear power plants. In abroad, especially in the United States and Canada PCCP supplies virtually every metropolitan area with raw and treated water. Compared with other pipe types, PCCP manufacturing cost is dear. But total cost can be considered as economical due to low installation and maintenance cost. Previously, the designs of PCCP were generally determined from one of two appendices in American Water Works Association(AWWA)standard C301 which provided two design methods-cubic parabola design method and stress analysis design method. In 1992, the design procedure for PCCP expanded from two alternatives to the most huge and complex AWWA standard C304. Because C304is so large, it takes too much time for the engineer to read and understand the design concepts and procedures. In this paper, the AWWA C304 design procedures are segmented into simple, understandable sections and concepts and explained. Each section or concepts is compared to the previous design procedure to highlight the revisions and reasons for them. Also the PCCP design program was developed and the design program results are compared with the calculations of the GMR project design consultant.

  • PDF

갱생 옥내급수관 수돗물에서 비스페놀-A 분포 및 위해성 평가 (Distribution and Risk Assessment of Bisphenol-A in Tap Water from Rehabilitated Indoor Water Service Pipe)

  • 정관조;손보영;이인자;안치화;김준일;문보람;이수원;안재찬;김복순;정득모
    • 대한환경공학회지
    • /
    • 제38권7호
    • /
    • pp.371-376
    • /
    • 2016
  • 본 연구에서는 에폭시 수지 갱생 옥내급수관 수돗물에 대해 비스페놀-A 실태조사를 실시하였고, 비스페놀-A가 수돗물 음용에 있어 인체에 미치는 영향을 파악하기 위해 위해성 평가를 실시하였다. 원수 중 비스페놀-A는 50~118 ng/L로 채취된 모든 시료에서 정량한계 10 ng/L 이상으로 검출되었다. 이것은 주변지역의 하수 방류수나 지천에 의한 비스페놀-A 유입에 의한 것으로 판단된다. 정수에서의 비스페놀-A는 불검출되었으며, 고도정수처리 공정에서 모두 제거된 것으로 추정되었다. 응집-침전과정과 오존 및 염소에 의해 산화되어 제거되거나 다른 산화 부산물질로 변화한 것으로 판단된다. 옥내급수관 수돗물의 경우, 에폭시 갱생공사를 실시하지 않은 수돗물 모두에서 비스페놀-A는 검출되지 않았다. 그러나 에폭시 갱생공사를 실시한 옥내급수관 수돗물에서 비스페놀-A가 불검출에서 최대 521 ng/L로 범위로 검출되었으며, 채취된 시료의 68%가 정량한계 이상으로 검출되었다. 검출된 비스페놀-A의 최대값(521 ng/L)에 대한 위해도 지수 산정 결과, 위해도 지수(HQ)는 약 0.004로 수돗물 섭취에 의한 위해판단 기준값 0.1 이하로 나타나 음용에 안전한 것을 확인하였다.

수세정에 의한 바이오가스 중 이산화탄소의 제거 효율 (Water Scrubbing of Carbon Dioxide for Improving Calorific Values of Biogass)

  • 심재훈;홍성구;권순국
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.598-603
    • /
    • 2005
  • Biogas produced from anaerobic digestion processes has about 60% of methane and about 40% of carbon dioxide. Raw biogas can be used in internal combustion engines either spark ignition or diesel engines. Since the gas has relatively low calorific values, engine power also is lower than rated power values. Modified engines or biogas-specific engines have been utilized in order to increase efficiency. Another option is gas cleansing for increasing its calorific values. A couple of European countries adopted this approach in using biogas for one of transportation fuels, such as $CO_2$ scrubbing with water or special solutions. This study reports the results of water scrubbing for reducing $CO_2$ concentration. In 2.5m-high PVC pipe accepting water, $CO_2$ reduction rates were investigated. When flow rate of $CO_2$ and air mixture was about 5 LPM, $CO_2$ concentration was decreased up to 70%. Higher calorific biogas through water scrubbing is expected to be applied to various commercial engines without costly modification.

  • PDF

Occurrence of Disinfection By-Products and Distribution in Drinking Water

  • In, Chi-Kyung;Lee, Jung-Ho;Lee, In-Sook
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2005년도 Proceedings of KSEH.Minamata Forum
    • /
    • pp.103-114
    • /
    • 2005
  • Chlorine disinfection has been used in drinking water supply to disinfect the water-borne microbial disease which may cause to serious human disease. As Chlorination is still the least costly, relatively easy to use, chlorination is the primary means to disinfect portable water supplies and control bacterial growth in the distribution system. However, chlorine also reacts with natural organic matter (NOM), which presents in nearly all water sources, and then produces disinfection by-product (DBps), which may have adverse health effects. Although the existent DBPs have been reported in drinking water supplies, it is not feasible to predict the levels of the various DBPs due to the complex chemistry reaction involved. The objectives of this study were to investigate seasonal variation of DBPs formation and difference of DBPs concentration in the plant to tap water. The average concentration of THMs was 20.04 ${\mu}g/{\ell}$, HAAs 8-15 ${\mu}g/{\ell}$, HANs 2-4.5 ${\mu}g/{\ell}$ respectively. Distant variation of DBPs formation is that THMs concentration increase by 17% at 2 km point from the plant and by 28% at 7 km and HAAs, HANs also increase each by 16%, 32%, at 2 km from the plant and 35%, 56%, at 7 km. DBPs increase in water supply pipe continually. The seasonal occurrence of DBPs is that in May and August DBPs concentration is very high then in March, in May DBPs concentration is highest. The temperature is main factor of DBPs formation, precursor also. Precursor which was accumulated for winter flowed into the raw water by flooding in spring and summer and produced DBPs. Therefore for the supply of secure drinking water, it is required to protect precursor of flowing into raw water and to add to BCAA and DBAA to drinking water standards.

  • PDF

오수관 설계유량 산정법이 설계유속에 미치는 영향 (Design Flow Velocity Changes According to the Design Flow Determination Methods in the Sanitary Sewer)

  • 현인환;원승현;김형준;이제인
    • 상하수도학회지
    • /
    • 제19권6호
    • /
    • pp.749-757
    • /
    • 2005
  • The present study analyzed actual cases of designed flow estimation method and designed flow rate of sewage pipe lines. In order to examine the effects of peak-hour demand factor estimation with given daily highest peak loading, we analyzed its effects on designed flow rate with changing the peak-hour demand factor from 2.0 to 10.0. The results of this study are as follows. When reviewing the recent designs, we found that 59.4% of pipe line with 250mm and 300mm diameter, which fall under minimum allowable pipeline did not meet the minimum velocity which is specified as 0.6m/sec in design standards. The pipe line that have minimal access population or have very low slope did not satisfy the minimum velocity. In estimating the designed sewage flow, the applied daily highest peak loading and hourly highest peaking loading were the load factor for the entire population of the planned area, and for the peak loading of the initial pipes connected to a very small population, we applied the same factor as that applied to the entire area and, as a result, the hourly highest flow was underestimated. Because, in case of the initial pipes, the method of applying the same peak loading to all subject areas is highly possible to produce underestimated design flow, when estimating the designed flow of the initial pipes connected to a small population need to adopt a rational flow factor according to the size of population. For this, it is considered to investigate and analyze raw data on daily and hourly variation of sewage flow.

파이프-유체의 연성진동을 이용한 누수위치 식별연구 (Pinpointing of Leakage Location Using Pipe-fluid Coupled Vibration)

  • 이영섭;윤동진
    • 한국소음진동공학회논문집
    • /
    • 제14권2호
    • /
    • pp.95-104
    • /
    • 2004
  • Leaks in underground pipelines can cause social, environmental and economical problems. One of relevant countermeasures against leaks is to find and repair of leak points of the pipes. Leak noise is a good source to identify the location of leak points of the pipelines. Although there have been several methods to detect the leak location with leak noise, such as listening rods, hydrophones or ground microphones, they have not been so efficient tools. In this paper, accelermeters aroused to detect leak locations which could provide an easier and more efficient method. Filtering, signal processing and algorithm of raw input data from sensors for the detection of leak location are described. A 120m-long and a 70m-long experimental pipeline systems are installed and the results with the systems show that the algorithm with the accelerometers offers accurate pinpointing for leaks location detection. Theoretical analysis of sound wave propagation speed of water in underground pipes, which is critically important in leak locating, is also described.

Faster R-CNN을 활용한 GPR 영상에서의 지하배관 위치추적 성능분석 (Performance Analysis of Detecting buried pipelines in GPR images using Faster R-CNN)

  • 고형용;김남기
    • 융합정보논문지
    • /
    • 제9권5호
    • /
    • pp.21-26
    • /
    • 2019
  • 도심지에는 상 하수관로, 가스관, 수소관 등 필요에 따라 여러 가지 배관이 매설된다. 매설된 배관은 시간이 경과됨에 따라 균열 등으로 노후화되면서 폭발, 누수 등의 사고 발생 위험을 가지게 된다. 이러한 위험을 방지하기 위해 많은 노후 배관 수리, 교체되지만, 배관의 위치 또한 변경될 수 있다. 변경된 배관의 위치를 확인하지 못하면 배관을 건드려서 사고가 발생할 수 있다. 본 논문에서는 GPR을 사용하여 지하 단면 영상을 얻고, Faster R-CNN을 활용하여 지하 배관의 위치를 추정해보고, augmentation을 적용하여 부족한 데이터를 늘려서 실험을 진행하였다.

원자력발전소 적용 고밀도 폴리에틸렌 배관의 맞대기 융착절차 및 검증절차 분석 (Butt-fusing Procedures and Qualifications of High Density Polyethylene Pipe for Nuclear Power Plant Application)

  • 오영진;박흥배;신호상
    • Journal of Welding and Joining
    • /
    • 제31권6호
    • /
    • pp.1-7
    • /
    • 2013
  • In nuclear power plants, lined carbon steel pipes or PCCPs (pre-stressed concrete cylinder pipes) have been widely used for sea water transport systems. However, de-bonding of linings and oxidation of PCCP could make problems in aged NPPs (nuclear power plants). Recently at several NPPs in the United States, the PCCPs or lined carbon steel pipes of the sea water or raw water system have been replaced with HDPE (high density polyethylene) pipes, which have outstanding resistance to oxidation and seismic loading. ASME B&PV Code committee developed Code Case N-755, which describes rules for the construction of buried Safety Class 3 polyethylene pressure piping systems. Although US NRC permitted HDPE materials for Class 3 buried piping, their permission was limited to only 10-year operation because of several concerns including the quality of fusion zone of HDPE. In this study, various requirements for fusion qualification test of HDPE and some regulatory issues raised during HDPE application review in foreign NPPs are introduced.