• Title/Summary/Keyword: Ratio of oil/water

Search Result 309, Processing Time 0.027 seconds

Durable Water and Oil Repellent Finish of Wool Fabric(I) (양모직물의 내구성 발수 및 발유가공(I))

  • 나도춘;정순량;박병기;정경락
    • Textile Coloration and Finishing
    • /
    • v.10 no.1
    • /
    • pp.33-37
    • /
    • 1998
  • It is rather important in the water and oil repellent finishing for wool fabric what kind of water-repellent agents will be used. In many cases, Fluorocarbon-based water-repellent agents(eg.Oleophobol-S), the surface tensions of which very low, were recom-mended on account of good water and oil repellencies. In repellent finishing, fabrics were padded in a bath which contained aqueous solution of water-repellent agents, and wetting agents, followed by drying and curing. The most suitable treating condition for excellent repellency was as follows Fabrics were padded at liquor pick-up ratio of 50%, with aqueous solution which contained $30g/\ell$ of water-repellent agents, and $40g/\ell$ of wetting agents. And the padded fabrics were dried at $110^\circ{C}$ for 1 minute, and cured at $160^\circ{C}$ for 2 minutes. For the fabrics, water and oil repellencies and durability to repeated dry-cleanings are observed.

  • PDF

Utilization of Pyrolysis Oil from Pine Wood as Thermosetting Wood Adhesive Resins

  • Kim, Jae-Woo;Myers, Deland J.;Brown, Robert C.;Kuo, Monlin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.51-60
    • /
    • 2007
  • In this study, the possibility of using pyrolysis oil as wood adhesives was explored. Especially, adhesives were formulated by reacting pyrolysis oil and formaldehyde and also partially replacing phenol with pyrolysis oil in phenol-formaldehyde (PF) adhesive and soy hydrolizate/PF adhesive formulation. The pine wood was fast pyrolyized and the oils were obtained from a series of condensers in the pyrolysis system. The oils from each condenser were first reacted with formaldehyde to explore potential use of the oil itself as adhesive. The lap-shear bond strength test results indicated that the oil itself could be polymerized and form bonds between wood adherends. The oils from each condenser were then mixed together and used as partial replacement of phenol (25, 33, and 50% by weight) in phenol-formaldehyde adhesive. The bond strength of the oil containing PF adhesives was decreased as percent phenol replacement level increased. However, no significant difference was found between 25 and 33% of phenol replacement level. The oil-contained PF resins at 25, 33, and 50% phenol replacement level with different NaOH/Phenol (Pyrolysis oil) molar ratio were further formulated with soy hydrolizate to make soy hydrolizate/pyrolysis oil-phenol formaldehyde adhesive at 6:4 weight (wt) ratio and used for fiberboard manufacturing. Surface internal bond strength (IB) of the boards bonded with 33% replacement at 0.3 NaOH/Phenol (Pyrolysis oil) molar ratio performed better than other replacement levels and molar ratios. Thickness swelling after 24 hr cold water soaking and after 2 hr in boiling water was increased as % replacement of pyrolysis oil increased.

The Effect of Property of Emulsified Fuel and Injection Pressure on the Spray Characteristics for Super-Critical-Pressure Burner (초임계압 보일러용 유화연료의 물성치와 분사압력이 분무특성에 미치는 효과)

  • Lee, I.S.;Jung, J.W.;Cha, K.J.;Kim, D.J.
    • Journal of ILASS-Korea
    • /
    • v.7 no.3
    • /
    • pp.38-44
    • /
    • 2002
  • The purpose of this study is to investigate the effect of the volume fraction of water and injection pressure on the spray characteristics of water/oil emulsified fuel injected from the pressure swirl atomizer. The mixture of light oil and water by using impeller mixer was performed. The spray characteristics such as SMD and velocity were measured using PDPA. The injection pressures were 7.5, 100, 200 and $300kgt/cm^2$ and volume fractions of water in emulsified fuel were 0, 10, 20 and 30%, respectively. The measurement sections were at 30, 60 and 90mm from injection nozzle tip. SMD and velocity of emulsified fuel were larger gradually by increasing the volume fraction of water in emulsified fuel. The spray angle was decreased and axial velocity was increased with increase in water content. It was found that the relative SMD ratio was increased more greatly than the relative axial velocity ratio in super critical pressure. The relative SMD ratio was increased and the relative axial velocity ratio was decreased with increase injection pressure at spray downstream.

  • PDF

In-line Smart Oil Sensor for Machine Condition Monitoring (기계 상태진단을 위한 인-라인형 오일 모니터링 스마트 센서)

  • Kong, H.;Ossia, C.V.;Han, H.G.;Markova, L.
    • Tribology and Lubricants
    • /
    • v.24 no.3
    • /
    • pp.111-121
    • /
    • 2008
  • An integrated in-line oil monitoring detector assigned for continuous in situ monitoring multiple parameters of oil performance for predicting economically optimal oil change intervals and equipment condition control is presented in this study. The detector estimates oil deterioration based on the information about chemical degradation, total contamination, water content of oil and oil temperature. The oil oxidation is estimated by "chromatic ratio", total contamination is measured by the changes in optical intensity of oil in three optical wavebands ("Red", "Green" and "Blue") and water content is evaluated as Relative Saturation of oil by water. The detector is able to monitor oils with low light absorption (hydraulic, transformer, turbine, compressor and etc. oils) as well as oils with rather high light absorption in visible waveband (diesel and etc. oils). In a case study that the detector is applied to a diesel engine oil, it is found that the detector provides good results on oil chemical degradation as well as soot concentration.

The Mortar Properties of Portland Cements Blended with Modified Coal Ashes (가공된 석탄재를 사용한 석탄재혼합시멘트의 모르터 특성)

  • 홍원표;노재성;조헌영;정수영;김무한
    • Journal of the Korean Ceramic Society
    • /
    • v.27 no.7
    • /
    • pp.833-840
    • /
    • 1990
  • For the development of multi-functional materials which has water reducing power, air entraining power and waterproofing power as well as blending additive in cement mortar the coal ash was modified with asphalt-stearic acid or asphalt-boiled oil mixtures by mechanical treatment. And the physical properties of cement mortar blended with modified coal ashes were compared with those of the water-tightness-cement mortar and the ordinary-portland-cement mortar added with AE.water reducing agent. The mortar of coalash-blend-cement modified with asphalt-stearic mixture was increased acid about 20% in initial strengths and decreased about 20% in water absorption ratio than those of ordinary coalash-blend-cement. The mortar of coalash-blend-cement modified with asphalt-bolied oil mixture was similar to the cement mortar added with AE.water reducing agent in water reduction ratio, air entraining conents and the initial strengths, also was similar to the water-tightness-cement mortar in water absorption and water permeability ratios.

  • PDF

Synthesis and Characteristics of PU Oil-Gelling Agents According to the Soft Segment Content (Soft Segment 조성에 따른 PU 유겔화제의 합성 및 특성)

  • Lee, Yong-Hun;Kim, Wook;Kim, Won-Ho
    • Polymer(Korea)
    • /
    • v.24 no.6
    • /
    • pp.744-750
    • /
    • 2000
  • Oil gelling agent was synthesized with PPG, PTMG and TDI at 7$0^{\circ}C$ for 4hours. PPGs and PTMGs having various average molecular weights (M$_{n}$: 1000, 2000, 3000) were employed to investigate the ratio of oil gelation and water gelation. As M$_{n}$ of PPG, in result, was decreased from 3000 to 1000, the ratio of oil gelation was increased from 130% to 290% for PPG and from 250% to 310% for PTMG. Ratio of oil gelation was increased approximately two times when EG was added. As the amount of hydrophilic compound in the prepolymer was increased, ratio of oil gelation was increased from 290% to 1120% for PPG and increased from 310% to 1310% for PTMG, due to the increased dispersion of prepolymer in the water/oil mixture.ure.

  • PDF

High prandtl number natural convection in a low-aspect ratio rectangular enclosure (종횡비 가 낮은 직각밀폐용기내 의 Prandtl 수 가 큰 유체 의 자연대류 에 관한 실험적 연구)

  • 이진호;황규석;현명택
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.6
    • /
    • pp.750-756
    • /
    • 1985
  • Experimental investigation was carried out to study the natural convection of water and silicon oil due to end temperature differences in a horizontally insulated rectangular enclosure of aspect ratio 0.1 with a special attention on the core configuration in the laminar boundary-layer flow regime. Rayleigh number ranges covered herein are Ra=4.40 * 10$^{6}$ -9.64 * 10$^{7}$ for water and Ra=1.69*10$^{5}$ -3.80*10$^{6}$ for silicon oil, respectively. In the case of water, for Ra.geq.2.21 * 10$^{7}$ there appeared distinct horizontal thermal layers adjacent to the horizontal boundaries in the core and the temperature distribution outside the horizontal thermal layers, i.e., in the mid-core region, is vertically stratified. The core flow pattern was shown to be nonparallel with a weak back flow in the mid-core for Ra.geq.3.63 *10$^{7}$ . In the case of silicon oil, distinct horizontal thermal layers appeared along the core horizontal boundaries for Ra.geq.1.27 * 10$^{6}$ with a stratified temperature distribution in the mid-core, but the core flow pattern in this case was shown to be parallel. In addition, secondary flow appeared near the hot wall for Ra.geq.3.80 * 10$^{6}$ . Nusselt number, Nu, was found to be proportional to R $a^{0.3}$ for water and R $a^{0.28}$ for silicon oil in the boundary-layer flow regime. There also in an indication from the comparison with other results that Nu is independent of aspect ratio for water in the boundary-layer flow regime in low aspect ratio enclosures.res.

Strength and Autogenous Shrinkage of High Strength Mortar Using Water Substituting Liquid

  • Han, Min-Cheol;Lee, Dong-Gyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.6
    • /
    • pp.538-546
    • /
    • 2011
  • This paper is to experimentally investigate the strength and autogenous shrinkage of high strength mortar with the 20 % of water?binder ratio(W/B). In this study, the water substituting liquid(WSL) was used including gasoline, light oil, lamp oil, edible oil, HFE, ethanol, methanol and acetone in order to explore changes in strength and autogenous shrinkage depending on WSL type and replacement. For fresh properties, the replacement of WSL did not affect the fluidity of mortar mixtures considerably, except for ethanol and methanol. However, the replacement of WSL resulted in a slight decrease in flexural and compressive strength. For autogenous shrinkage, the replacement of WSL led to reduce autogenous shrinkage, and especially, the replacement of edible oil led to reduce autogenous shrinkage significantly due to saponification between edible oil and cement.

Case Study on Integrated In-line Oil Monitoring Sensor for Machine Condition Monitoring of Steel Making Industry (통합형 인-라인 오일 모니터링 센서의 제철설비 현장 적용사례)

  • Kong, H.;Han, H.G.;Kwak, J.S.;Chang, W.S.;Im, G.G.
    • Tribology and Lubricants
    • /
    • v.26 no.1
    • /
    • pp.73-77
    • /
    • 2010
  • One of the important trends for condition monitoring in the 21st century is the development of smart sensors that will permit the cost-effective continuous monitoring of key machine equipments. In this study, an integrated in-line oil monitoring sensor assigned for continuous in situ monitoring multiple parameters of oil performance is presented. The sensor estimates oil deterioration based on the information about chemical degradation, total contamination, water content of oil and oil temperature. The oil oxidation is estimated by "chromatic ratio", total contamination is measured by the changes in optical density of oil in three optical wave-bands ('Red', 'Green' and 'Blue') and water content is evaluated as relative saturation of oil by water. In order to evaluate the sensor's effectiveness, the sensor was applied to several used oil samples in steel making industry and the results were compared with those measured by standard test methods.

Evaluation of Oil Infiltration Behavior in Porous Media Using Dielectric Response (유전율에 의한 지반 매질내 유류침투거동 분석)

  • Kim Man-Il;Jeong Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.15 no.1
    • /
    • pp.29-39
    • /
    • 2005
  • For detecting a ground contamination survey, soil sampling method have been used a drilling or coring technique in general. However these methods are very difficult to systematically real-time monitoring of variation of contamination degree in field. ]'n this research frequency Domain Reflectometry (FDR) system was suggested and carried out to experimental approaches for determination of oil contamination on surface and underground. Experimental method using FDR method was discussed with feasibility of measurement in the laboratory column test. It is determined to degree of oil contamination due to response of dielectric constant re-lated with volumetric water content(θ/sub w/) and volumetric oil content( θ/sub al/ ) of saturated and unsaturated soil media. And physical properties such as effective porosity and oil residual ratio of saturated soil media were also measured through real-time monitoring works using installed FDR measurement sensors, which are defected characteristics of oil movement in the saturated soil media under the soil column tests. In the results of these experiments, a range of effective porosity was estimated to about 0.35 compared with initial porosity 0.40 of manufactured saturated soil media, which is also calculated to about 87.5% to the ratio of initial porosity to effective porosity. Finally oil residual ratio which is compared with volumetric water content and volumetric oil content was calculated about 62.5%.