• 제목/요약/키워드: Ratio Test

검색결과 11,138건 처리시간 0.037초

솔라윙 시스템의 풍진동 특성 평가 (Evaluation of Aerodynamic Performance of Solar Wing System)

  • 김용철;윤성원
    • 한국공간구조학회논문집
    • /
    • 제16권1호
    • /
    • pp.65-72
    • /
    • 2016
  • Aerodynamic performance of solar wing system has been evaluated through wind tunnel test. The test model has 12 panels, each supported by 2 cables. The panels were installed horizontally flat, and gaps between panels were set constant. Sag ratios of 2% and 5%, and wind directions between $0^{\circ}$ and $90^{\circ}$ were considered. Mass of test model was determined considering the mass of full scale model, and Froude number and Elastic parameter were satisfied by adjusting the mean wind speed. From the wind tunnel test, it was found that the aerodynamic performance of the solar wing system is very dependent on the wind directions and sag ratios. When the sag was 2%, the fluctuating displacements between the wind directions of $0^{\circ}$ and $30^{\circ}$ increase proportionally to the square of the mean wind speed, implying buffeting-like vibration and a sudden increase in fluctuating displacement was found at large mean wind speed for the wind directions larger than $40^{\circ}$. When the wind direction was larger than $60^{\circ}$, a sudden increase was found both at low and large mean wind speed. When the sag ratio is 5%, distribution of mean displacements is different from that of sag ratio of 2%, and the fluctuating displacements show very different trend from that of sag ratio of 2%.

국소 최적성과 순차 기준을 바탕으로 한 검파 기법: 1. 문턱값 분석 (Detection Schemes Based on Local Optimality and Sequential Criterion: 1. Threshold Analysis)

  • 최상원;오종호;권형문;윤석호;배진수;송익호
    • 한국통신학회논문지
    • /
    • 제30권6C호
    • /
    • pp.532-540
    • /
    • 2005
  • 이 논문에서는 새로운 약신호 검파 기법을 얻어, 그 기법과 국소 최적 검파 기법을 바탕으로 순차 검파 방식을 이끌어낸다. 먼저, 1부에서는 새로운 약신호 검파 기법을 제안하고, 흥미로운 문턱값 성질을 몇가지 밝히며, 여러 가지 잡음 분포에서 문턱값 보기를 다룬다. 한편, 2부에서는 제안한 순차 검파 방식의 성능을 고정 표본 검파 방식, 순차 확률비 검파 방식, 끝을 자른 순차 확률비 검파 방식의 성능과 견주어 본다.

횡방향 가력실험 및 충격실험을 통한 강판콘크리트(SC) 전단벽의 감쇠비 평가 (Investigation of Damping Ratio of Steel Plate Concrete (SC) Shear Wall by Lateral Loading Test & Impact Test)

  • 조성국;소기환;박웅기
    • 한국지진공학회논문집
    • /
    • 제17권2호
    • /
    • pp.79-88
    • /
    • 2013
  • Steel plate concrete (SC) composite structure is now being recognized as a promising technology applicable to nuclear power plants as it is faster and suitable for modular construction. It is required to identify its dynamic characteristics prior to perform the seismic design of the SC structure. Particularly, the damping ratio of the structure is one of the critical design factors to control the dynamic response of structure. This paper compares the criteria for the damping ratios of each type of structures which are prescribed in the regulatory guide for the nuclear power plant. In order to identify the damping ratio of SC shear wall, this study made SC wall specimens and conducted experiments by cyclic lateral load tests and vibration tests with impact hammer. During the lateral loading test, SC wall specimens exhibited large ductile capacities with increasing amplitude of loading due to the confinement effects by the steel plate and the damping ratios increased until failure. The experimental results show that the damping ratios increased from about 6% to about 20% by increasing the load from the safe shutdown earthquake level to the ultimate strength level.

실내시험을 이용한 저치환 보강지반의 평가 (Evaluation of the Low Replacement Reinforced Ground Using Laboratory Tests)

  • 배우석
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.131-137
    • /
    • 2008
  • SCP(Sand Compaction Pile) method that forms a composite ground by driving compacted sand piles into the soft ground. This method is one of the soil improvement techniques for reinforcing and strengthening soft ground deposits. This thesis describes the investigation on the behavior of soft ground reinforced with SCP by low improvement ratio. Direct shear test and consolidation test carried out to verified behavior of composite ground reinforced with SCP. Test results were discussed with reference to the amount of consolidation settlement, variation of shear resistance with area replacement ratio and effect of the stress concentration. And, laboratory model loading test carried out to verified the effect of the location and failure mode of reinforced embankment. Residual shear strength varies with the area replacement and constrict load in the low replacement ratio. Calculated stress concentration ratio overestimate than proposed valve by experimental, theoretical and analytical method. As regards the location, improving right below of the top of the slope was more effective than below of the toe of the slope. This thesis carried out to obtain fundamental information of behavior of the composit ground. Hereafter, centrifuge test that reproduce stress state of the in-situ must be necessary through the further study about pile penetration, reinforce position and construct time.

실험자료를 기반한 국내 원형단면 철근콘크리트 휨교각의 손상수준 별 횡변위비 산정 (Estimation of Drift Ratio by Damage Level for Flexural RC Piers With Circular Cross-Section Based on Experimental Data in Korea)

  • 남현웅;홍기증;김익현
    • 한국지진공학회논문집
    • /
    • 제26권6호
    • /
    • pp.255-265
    • /
    • 2022
  • In order to determine fragility curves, the limit state of piers for each damage level is suggested in this paper based on the previous test results in Korea, including our test results. In previous studies, the quantitative measures for damage levels of piers have been represented by curvature ductility, lateral drift ratio, or displacement ductility. These measures are transformed to lateral drift ratios of piers for consistency, and the transformed values are compared and verified with our push-over test results for flexural RC piers with a circular cross-section. The test specimens are categorized concerning the number of lap-splices in the plastic hinge region and whether seismic design codes are satisfied or not. Based on the collected test results in Korea, including ours, the lateral drift ratio for each pier damage level is suggested.

Influence Measures for a Test Statistic on Independence of Two Random Vectors

  • Jung Kang-Mo
    • Communications for Statistical Applications and Methods
    • /
    • 제12권3호
    • /
    • pp.635-642
    • /
    • 2005
  • In statistical diagnostics a large number of influence measures have been proposed for identifying outliers and influential observations. However it seems to be few accounts of the influence diagnostics on test statistics. We study influence analysis on the likelihood ratio test statistic whether the two sets of variables are uncorrelated with one another or not. The influence of observations is measured using the case-deletion approach, the influence function. We compared the proposed influence measures through two illustrative examples.

Minimum Hellinger Distance Bsed Goodness-of-fit Tests in Normal Models: Empirical Approach

  • Dong Bin Jeong
    • Communications for Statistical Applications and Methods
    • /
    • 제6권3호
    • /
    • pp.967-976
    • /
    • 1999
  • In this paper we study the Hellinger distance based goodness-of-fit tests that are analogs of likelihood ratio tests. The minimum Hellinger distance estimator (MHDE) in normal models provides an excellent robust alternative to the usual maximum likelihood estimator. Our simulation results show that the Hellinger deviance test (Simpson 1989) based goodness-of-fit test is robust when data contain outliers. The proposed hellinger deviance test(Simpson 1989) is a more direcct method for obtaining robust inferences than an automated outlier screen method used before the likelihood ratio test data analysis.

  • PDF

Elimination of the effect of strain gradient from concrete compressive strength test results

  • Tabsh, Sami W.
    • Computers and Concrete
    • /
    • 제3권6호
    • /
    • pp.375-388
    • /
    • 2006
  • Poor strength test results are sometimes not an indication of low concrete quality, but rather inferior testing quality. In a compression test, the strain distribution over the ends of the specimen is a critical factor for the test results. Non-uniform straining of a concrete specimen leads to locally different compressive stresses on the cross-section, and eventual premature breaking of the specimen. Its effect on a specimen can be quantified by comparing the compressive strength results of two specimens, one subjected to uniform strain and another to a specified strain gradient. This can be done with the help of a function that relates two parameters, the strain ratio and the test efficiency. Such a function depends on the concrete strength and cross-sectional shape of the specimen. In this study, theoretical relationships between the strain ratio and test efficiency are developed using a concrete stress-strain model. The results show that for the same strain ratio, the test efficiency is larger for normal strength concrete than for high strength concrete. Further, the effect of the strain gradient on the test result depends on the cross-sectional shape of the specimen. Implementation of the results is demonstrated with the aid of two examples.

An Experimental Study on Interrelation of Influential Parameters on Unbonded Tendon Stress

  • Moon, Jeong-Ho;Lim, Jae-Hyung
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권2E호
    • /
    • pp.111-116
    • /
    • 2006
  • The purpose of this study is to investigate the relations between unbonded tendon stress and its influential parameters, i.e. bonded reinforcement ratio, span/depth ratio, and loading type. To this end, the influence of such parameters was examined with twenty eight test results of previous studies. Afterwards, an experimental study was carried out with twenty one test specimens. The investigation of previous and current experiments revealed the followings; (1) The bonded reinforcement ratio and prestressing ratio were proved to be important variables on the unbonded tendon stress. (2) The ratio of span to depth and the type of loading affected the unbonded tendon stress partially although their effects varied with bonded reinforcement ratio. (3) AASHTO LRFD Code and Moon/Lim's design equations predicted the experimental results well with the safety margin.

반복재하후 미액상화 풍화토 지반의 변형 거동 (Post-Cyclic Deformation Behavior of Non-Liquefied Weathered Soils)

  • 최연수;정충기
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.485-492
    • /
    • 2001
  • Weathered soil is one of the most representative soils in Korea. In this study, a series of cyclic triaxial tests was carried out to predict the post-cyclic deformation behavior of weathered soils in case of non-liquefaction. Excess pore pressure response during cyclic loading and volumetric strain during the dissipation of excess pore pressure were measured varying the confining pressure, relative density and cyclic stress ratio. Based on the test results, it Is found that the modified excess pore pressure ratio, excess pore pressure ratio normalized by cyclic stress ratio, is uniquely correlated with the number of cycles irrespective of confining pressure and cyclic stress ratio. Using the newly proposed MEPPR(modified excess pore pressure ratio) concept, it is possible to easily evaluate the excess pore pressure and the settlement of weathered soils due to cyclic loading by greatly reduced number of tests. It is also verified that the reconsolidation volumetric strain is independent of the way how the excess pore pressure was generated.

  • PDF