• 제목/요약/키워드: Rating Power

검색결과 515건 처리시간 0.023초

Fuzzy PID Controller for Accurate Power Sharing in DC Microgrid

  • Nguyen, Duy-Long;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.115-117
    • /
    • 2019
  • In this paper, an intelligent control scheme based on Fuzzy PID controller is proposed for accurate power sharing in DC Microgrid. The proposed Fuzzy PID controller is designed with the aid of a closed loop control based on per unit power of each distributed generator (DG), and accurate power sharing is successfully realized in proportional to each DG's power rating regardless of the line resistance difference or the load change. Thanks to Fuzzy PID controller, the dynamic response becomes faster and the stability of the microgrid system are improved in comparison to conventional PID controller. The superiority of the proposed method is analyzed and verified by simulation in Matlab and Simulink.

  • PDF

STATCOM Helps to Guarantee a Stable System

  • Andersen, B.R;Gemmell, B.D.;Horwill, C.;Hanson, D.J.
    • Journal of Power Electronics
    • /
    • 제1권2호
    • /
    • pp.65-70
    • /
    • 2001
  • Transmission System Operators are governed by operational security standards that are applied in real time. During system disturbances, the System Operators must rely on the installed protection and control equipment, prior to human intervention. New power electronic solutions bring rapid and repeatable responses to disturbances, which will help System Operators to guarantee a stable system. Last year, Alstom completed the world's first competitively bid STATCOM to support the voltage on National Grid's 400kV network that supplies London and the Southeast from the north of the UK. It is rated ${\pm}75MVAr$ and forms part of a Static Var System (SVS) with a total rating of 0 to 225MVAr. This paper will describe the reasons for its size, location, its chain-link configuration and give examples of its operating performance. The paper will also describe the features that allow this STATCOM to deliver much more than reactive compensation in support of a wider transmission service objective, as system conditions require.

  • PDF

Bi-2212/Cu-Ni 튜브로 제작한 초전도 한류소자의 단락사고시험 결과 (Fabrication and Fault Test Results of Bi-2212/Cu-Ni Tubes for Superconducting Fault Current Limiting Elements)

  • 오성용;임성우;유승덕;김혜림;현옥배
    • Progress in Superconductivity
    • /
    • 제10권1호
    • /
    • pp.45-49
    • /
    • 2008
  • For the development of superconducting fault current limiters (SFCLs), fault current limiting elements were fabricated out of Bi-2212 bulk tubes and tested. The SFCL elements consisted of tube shaped Bi-2212 bulks and metal shunts for the stabilizers. Firstly, the Bi-2212 bulk tubes were processed based on a design of monofilar coils in order to acquire large resistance and high voltage rating. 300 mm-long Bi-2212 tubes were designed to have the current path of 410 cm in length with 24 turns and 41 mm in diameter. The processed monofilar coil, as designed, had 300 A $I_c$ at 77 K. The fabricated superconducting monofilar coils were affixed to Cu-Ni alloy as that of stabilizers. The Cu-Ni alloys were processed to have the same shape of the superconducting monofilar coils. The Cu-Ni coil had resistivity of 32 ${\mu}{\Omega}$-cm at 77 K and 37 ${\mu}{\Omega}$-cm at 300 K. The metal shunts were attached to the outside of the Bi-2212 monofilar coil by a soldering technique. After the terminals made of copper were attached to both ends of the superconductor-metal shunt composite, the gap between the turns and the surface of the elements was filled with an epoxy and a dense mesh made of FRP in order to enhance the mechanical strength. The completed SFCL elements went through fault tests, and we confirmed that the voltage rating of 143 $V_{rms}$ (E =0.35 $V_{rms}$/cm) could be accomplished.

  • PDF

보조권선을 사용한 자동차 헤드라이트용 고압방전 등 안정기 (Automotive HID ballast using auxiliary windings)

  • 이규찬;조보형
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.595-598
    • /
    • 1999
  • A new of the automotive High Intensity Discharge(HID) lamp ballast systems is proposed. Proposed scheme is consisted of the high frequency DC-DC converter and low frequency DC-AC inverter as same as conventional HID ballast system. But this system separates ignition voltage from dc link voltage, which results to used the lower voltage rating power devices for HID lamp ballast system compared with conventional system. As a result, proposed system has a lower cost and higher efficiency.

  • PDF

국내 소프트웨어 개발 프로세스의 경쟁력 분석 (- Analysis of Competitive Power of Software Development Process of Korea -)

  • 유영관;박철수;이종무
    • 대한안전경영과학회지
    • /
    • 제5권2호
    • /
    • pp.165-174
    • /
    • 2003
  • This paper analyzes the competitive power of domestic software industries focusing on the subjective rating of software development process. A survey is conducted to perform subjective evaluation of software development process of his/her company. Comparison between SPICE-experienced companies and non-experienced companies, between domestic companies and companies in developed countries are performed.

유한 요소 도구를 이용한 NPT IGBT의 열 특성 해석 (Analysis of Thermal Characteristics of NPT IGBT by using Finite element method)

  • 류세환;이명수;원창섭;안형근;한득영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.57-58
    • /
    • 2006
  • As the power density and switching frequency increase, thermal analysis of power electronics system becomes imperative. The analysis provides valuable information on the semiconductor rating, long-term reliability. In this paper, thermal distribution of the Non Punchthrough(NPT) Insulated Gate Bipolar Transistor has been studied. For analysis of thermal distribution, we obtained results by using finite element simulator, Ansys and thermal distributions form experiments.

  • PDF

New Development of Turbo-compressor and Fan on Design, Re-rating and Numerical Simulation in China

  • Gu, Chuangang
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.3-8
    • /
    • 2000
  • The new development of turbo-compressor and fan in China is introduced here. For improving the performance of compressor and fan, we have studied the design method, numerical simulation, unsteady flow and the strategy for anti-surge control, got some achievement.

  • PDF

유통 상장기업들의 부채변화에 관한 연구 (Debt Issuance and Capacity of Korean Retail Firms)

  • 이정환;손삼호
    • 유통과학연구
    • /
    • 제13권9호
    • /
    • pp.47-57
    • /
    • 2015
  • Purpose - The aim of this paper is to investigate the explanatory power of the Pecking-order theory (the cost of financing increases with asymmetric information) among Korean retail firms from the perspective of debt capacity. According to the Pecking-order theory, a firm's first preference is to use internal funds for its capital needs, its next preference is the issuance of debt, and its last preference is the issuance of equity; this is due to the information asymmetry problem between existing shareholders and investors. However, prior empirical studies, such as Lemmon and Zender (2010), argue that the entire sample test for the Pecking-order theory could be misleading due to the different levels of debt issuance capability of each of the individual firms; in fact, they confirm that the explanatory power of the Pecking-order theory improves after taking into account the differences in debt capacity of the U.S. firms they examined. This paper implements a case study approach among Korean retail firms to examine the relationship between debt capacity and the explanatory power of the Pecking-order theory in Korea. Research design, data, and methodology - This study uses the sample of public retail firms on the Korea Composite Stock Price Index (KOSPI) from the time period of 1990 to 2013. We gather related financial and accounting statements from the financial information firm WISEfn. Credit rating information is provided by the Korea Investor Service. We employ the models of Lemmon and Zender (2010) and Son and Kim (2013) to measure a firm's debt capacity. Their logit models use the rating dummy variable as a dependent variable and incorporate other firm characteristics as independent variables to estimate debt capacity. To test the Pecking-order theory, we adopt variants of the financing deficit model of Shyam-Sunder and Myers (1999). In the test of the Pecking-order theory, we consider all of the changes in total debt obligations, current debt obligations, and long-term debt obligations. Results - Our main contribution to the literature is our confirmation of the predicted relationship between debt capacity and the explanatory power of the Pecking-order theory among Korean retail firms. The coefficients on financing deficits become greater as a firm's debt capacity improves. This is consistent with the results of Lemmon and Zender (2010). The coefficients on the square of the financing deficits are also negative for the firms in the largest debt capacity group, which is also consistent with the predictions in prior literature. Conclusions - This study takes a case study approach by examining Korean retail firms. We confirm that the Pecking-order theory explains the capital structure of retail firms more appropriately, after taking into account the debt capacity of each firm. This result suggests the importance of debt capacity consideration in the testing of the Pecking-order theory. Our result also implies that there has been a potential underestimation of the explanatory power of the Pecking-order theory in existing studies.

Implementation of a ZVS Three-Level Converter with Series-Connected Transformers

  • Lin, Bor-Ren
    • Journal of Power Electronics
    • /
    • 제13권2호
    • /
    • pp.177-185
    • /
    • 2013
  • This paper studies a soft switching DC/DC converter to achieve zero voltage switching (ZVS) for all switches under a wide range of load condition and input voltage. Two three-level PWM circuits with the same power switches are adopted to reduce the voltage stress of MOSFETs at $V_{in}/2$ and achieve load current sharing. Thus, the current stress and power rating of power semiconductors at the secondary side are reduced. The series-connected transformers are adopted in each three-level circuit. Each transformer can be operated as an inductor to smooth the output current or a transformer to achieve the electric isolation and power transfer from the input side to the output side. Therefore, no output inductor is needed at the secondary side. Two center-tapped rectifiers connected in parallel are used at the secondary side to achieve load current sharing. Due to the resonant behavior by the resonant inductance and resonant capacitance at the transition interval, all switches are turned on at ZVS. Experiments based on a 1kW prototype are provided to verify the performance of proposed converter.