Power Management of Open Winding PM Synchronous Generator for Unbalanced Voltage Conditions

  • EL-Bardawil, Ashraf;Moussa, Mona Fouad
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2192-2201
    • /
    • 2016
  • Wind energy is currently the fastest-growing electricity source worldwide. The cost efficiency of wind generators must be high because these generators have to compete with other energy sources. In this paper, a system that utilizes an open-winding permanent-magnet synchronous generator is studied for wind-energy generation. The proposed system controls generated power through an auxiliary voltage source inverter. The VA rating of the auxiliary inverter is only a fraction of the system-rated power. An adjusted control system, which consists of two main parts, is implemented to control the generator power and the grid-side converter. This paper introduces a study on the effect of unbalanced voltages for the wind-generation system. The proposed system is designed and simulated using MATLAB/Simulink software. Theoretical and experimental results verify the validity of the proposed system to achieve the power management requirements for balanced and unbalanced voltage conditions of the grid.

A Study on the Characteristics for Power Capacitor under the Voltage Unbalance Operation (불평형 전압 운전시의 역률보상용 커패시터 특성 연구)

  • Kim, Il-Jung;Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.36-40
    • /
    • 2008
  • Most of the low-voltage feeder are designed with approximately balanced and connected at the three phase four wire systems. However, Most of the power distribution systems' load which is composed of single or three phase are unbalanced by generating load unbalance. Unbalanced current will draw a highly unbalanced voltage. The power factor of an induction motor at rated operation is between 25 and 90%, depending on the size and speed of the motor. However, many induction motors operate below the nominal rating, resulting in poor power factor. This condition needs power factor improvement. Addition of power capacitor at the motor terminal may draw to stress due to voltage unbalance. This paper presents operation characteristics on steady states of a three-phase induction motor under unbalanced voltages with power capacitor. The existence of voltage unbalance have an effect on stress of power capacitor.

Power Density Maximization of the Brushless DC Generator by Controlling the Optimal Current Waveform (최적 전류파형제어를 통한 브러시리스 DC 발전기의 출력밀도 최대화에 관한 연구)

  • 이형우
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.7
    • /
    • pp.430-436
    • /
    • 2004
  • This paper presents an advanced control technique for power density maximization of the Brushless DC (BLDC) generator by using the linear tracking method. In a generator of given rating, the weight and size of the system affect the fuel consumption directly. Therefore, power density is one of the most important issues in a stand-alone generator. BLDC generator has high power density in the machine point of view and additional increases of power density by control means can be expected. Conventional rectification methods cannot achieve the maximum power possible because of hon-optimal current waveforms. The optimal current waveform to maximize power density and minimize machine size and weight in a nonsinusoidal power supply system has been derived, incorporated in a control system, and verified by simulation and experimental work. A new simple algebraic method has been proposed to accomplish the proposed control without an FFT which is time consuming and complicated.

Gate Driver for Power Cell Driving of Bipolar Pulsed Power Modulator (양극성 펄스 파워 모듈레이터의 파워셀 구동을 위한 게이트 드라이버)

  • Song, Seung-Ho;Lee, Seung-Hee;Ryoo, Hong-Je
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.2
    • /
    • pp.87-93
    • /
    • 2020
  • This study proposes a gate driver that operates semiconductor switches in the bipolar pulsed power modulator. The proposed gate driver was designed to receive isolated power and synchronized signals through the gate transformer. The gate circuit has a separate delay in the on-and-off operation to prevent a short circuit between the top and bottom switches of each leg. On the basis of the proposed gate circuit, a bipolar pulsed power modulator prototype with a 2.5 kV/100 A rating was developed. Finally, the bipolar pulsed power modulator was tested under resistive load and plasma reactor load conditions. It is verified that the proposed gate driver can be applied to a bipolar pulsed power modulator.

Correlation Between the Height and the Subjective Discomfort Ratings and Muscle Performance at performing the Lower Arm's Pronation and Supination according to the Changes in Height of Working Table

  • Yoo, Kyung Tae;Choi, Jung Hyun;Kim, Hee Jung;Lee, Bom;Jung, Jea Wook;Choi, Wan Suk;Yun, Young Dae;Kim, Soon Hee
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.3 no.2
    • /
    • pp.469-474
    • /
    • 2012
  • The purpose of this study is to analyze the correlation between the stature and the muscle performance ratings and the subjective discomfort rations at performing lower arm's pronation and supination according to change sin the height of working table for more efficient performance at designing a working table and performing a work. For the purpose, this study conducted an experiment targeting 40 people in their 20s, who were classified into 4 groups each group composing 10 people at intervals of 5cm from the standard stature of 166.5cm. The experiment measured the maximum isometric pronation and the supination muscular power, and at measuring the factors, the heights of working tables were set as 800mm, 850mm, and 900mm. From the measurement results, it was found that the stature and the maximum muscular power was correlated. That is, as the experiment groups's average stature is higher, the maximum muscular power was higher. For the correlation between the motion patterns(pronation and supination) and the maximum muscular power, it was seen that the maximum muscular power was higher at performing the pronation than the supination. In the correlation between motion patterns and the subjective discomfort ratings, it was seen that the subjective discomfort rating was higher at performing the supination than the pronation. For the correlation between height adjustment and the subjective discomfort ratings, as the height of working table was lower, the subject discomfort rating was lower. Therefore there was no difference in the maximum muscular power according to the height changes of working table, but it was found that as the working table was higher, the user felt more comfortable.

Optimal Design of Power Loss for 3 Phase Voltage Source Inverter by using Thermal Management (써멀 메니지먼트(Thermal Management)에 의한 3상 전압형 인버터의 전력손실 최적화 설계)

  • Cho, S.E.;Park, S.J.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1757-1762
    • /
    • 2007
  • Recently, the demand for the low cost power conversion equipment is rapidly increased. To develop this three phase voltage source inverter, optimum power conversion equipment to system is designed. The optimum operation method to minimize the power loss also satisfy the life time of the power electronics that is request in the present industry. In this paper, the efficient operating method to change of the acceleration, jerk, and switching frequency in the interval of acceleration is selected to optimize the power loss and life time of the power electronics by using the elevator model. So, we proposed the method that 50[A] rating power electronics is adopted in 9[kW] load.

The Improvement of NGR for Power Transformer Open Circuit Protection (전력용변압기 단선 보호용 NGR 성능 개선)

  • Kang, Y.W.;Shim, E.B.;Kwak, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.83-88
    • /
    • 2004
  • As the electric system is getting larger to meet the increasing demand for electric power, the rating of power apparatus is becoming inevitably higher in its working voltage and larger in its capacity. According to KEPCO reports, power transformers in the KEPCO system have undergone troubles such as winding short insulation breakdowns every year since 1981. the cause of this troubles were high one line grounding fault currents in KEPCO systems that had direct grounding systems. KEPCO has installed the NGR(neutral grounding reactor) to lower this fault current and reduced winding short insulation breakdowns in power transformers. But when a circuit breaker opened a no load bus, some trips of circuit breakers for protecting transformer have occurred by mal-operation of 59GT(overvoltage ground relay) that detect disconnection of NGR. Therefore, in this paper, we analyzed the cause and examined the effect of time delav circuit to prevent wrong operation of 59GT.

  • PDF

Digital-Controlled Single-Phase Unified Power Quality Conditioner for Non-linear and Voltage Sensitive Loads

  • Ryoo Hong-Je;Kim Jong-Soo;Kisck Dragos Ovidiu
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.374-381
    • /
    • 2005
  • The ability to provide quality power has become a significant issue in power systems. The main causes of poor power quality are harmonic currents, poor power factor, supply-voltage variations, etc. A technique of achieving both active current distortion compensation, power factor correction and also mitigating the supply-voltage variation (sag or swell) at the load side is presented in this paper. The operation and rating issues of the proposed Single-phase Unified Power Quality Conditioner are also highlighted. To reduce the total cost while simultaneously increasing the performance, the system is fully digitally controlled using the fixed-point TMS320F240 digital signal processor. The performances of the UPQC, which is composed by shunt and series PWM controlled-converters, have been verified on a laboratory prototype.

A Study on the Power Loss Simulation of Inverter and Converter for Elevator (승강기용 전력변환장치의 IGBT 전력손실에 관한 연구)

  • Cho, Su-Eog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.116-123
    • /
    • 2014
  • In case of power electronics, th power loss and EMI noise of IGBT is different depends on a adopting technology with the same power rating. To reduce the EMI noise, we could increase the resistance of gate. But in this case, the power loss of IGBT is increased, In this paper, we simulated the power loss of IGBT with the speed profile of elevator by the changing IGBT type, the voltage between gate and emitter, the resistance of gate in converter and inverter for elevator. To optimize the power electronics with the satisfied life time, It is necessary that we calculate the power loss and the rise of temperature in IGBT with the adopting technology type, the resistence of gate, the voltage between gate and emitter.

Automatic Power Factor Correction Using a Harmonic-Suppressed TCR Equipped with a New Adaptive Current Controller

  • Obais, Abdulkareem Mokif;Pasupuleti, Jagadeesh
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.742-753
    • /
    • 2014
  • In this paper, a new continuously and linearly controlled capacitive static VAR compensator is proposed for the automatic power factor correction of inductive single phase loads in 220V 50Hz power system networks. The compensator is constructed of a harmonic-suppressed TCR equipped with a new adaptive current controller. The harmonic-suppressed TCR is a new configuration that includes a thyristor controlled reactor (TCR) shunted by a passive third harmonic filter. In addition, the parallel configuration is connected to an AC source via a series first harmonic filter. The harmonic-suppressed TCR is designed so that negligible harmonic current components are injected into the AC source. The compensator is equipped with a new adaptive closed loop current controller, which responds linearly to reactive current demands. The no load operating losses of this compensator are negligible when compared to its capacitive reactive current rating. The proposed system is validated on PSpice which is very close in terms of performance to real hardware.