• Title/Summary/Keyword: Rater reliability

Search Result 227, Processing Time 0.025 seconds

A Reliability Study of the Scale for Contraversive Pushing in Stroke Patients (뇌졸중 환자의 Scale for Contraversive Pushing의 신뢰도 연구)

  • Kim, Chung-Sun;Chang, Jong-Sung
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.4
    • /
    • pp.31-36
    • /
    • 2009
  • Purpose: Pusher syndrome in stroke patients is the tendency to push strongly toward the paretic side with the non-affected limbs. The purpose of this study was to estimated inter-rater and intra-rater reliability of the Scale for Contraversive Pushing (SCP). Methods: Fourteen patients in the acute phase after stroke onset were diagnosed with pusher syndrome. Two physical therapists randomly assessed the same patients on different occasions on the same day. Almost all patients were assessed on more than one day. The inter-rater and intra-rater reliability of the SCP was estimated by calculation of the intraclass correlation coefficient (ICC). Results: The intra-rater reliability of the SCP ranged from 0.87 to 0.97; the inter-rater reliability of the SCP ranged from 0.71 to 0.99 in sitting and standing positions. These results show good reliability for the calculated variables. Conclusion: The results provide support for the use of the SCP in assessing pusher syndrome based on its reliability in stroke patients. It may use the standardized clinical assessments in clinical implication.

  • PDF

Intra-Rater and Inter-Rater Reliability of Brain Surface Intensity Model (BSIM)-Based Cortical Thickness Analysis Using 3T MRI

  • Jeon, Ji Young;Moon, Won-Jin;Moon, Yeon-Sil;Han, Seol-Heui
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.3
    • /
    • pp.168-177
    • /
    • 2015
  • Purpose: Brain surface intensity model (BSIM)-based cortical thickness analysis does not require complicated 3D segmentation of brain gray/white matters. Instead, this technique uses the local intensity profile to compute cortical thickness. The aim of the present study was to evaluate intra-rater and inter-rater reliability of BSIM-based cortical thickness analysis using images from elderly participants. Materials and Methods: Fifteen healthy elderly participants (ages, 55-84 years) were included in this study. High-resolution 3D T1-spoiled gradient recalled-echo (SPGR) images were obtained using 3T MRI. BSIM-based processing steps included an inhomogeneity correction, intensity normalization, skull stripping, atlas registration, extraction of intensity profiles, and calculation of cortical thickness. Processing steps were automatic, with the exception of semiautomatic skull stripping. Individual cortical thicknesses were compared to a database indicating mean cortical thickness of healthy adults, in order to produce Z-score thinning maps. Intra-class correlation coefficients (ICCs) were calculated in order to evaluate inter-rater and intra-rater reliabilities. Results: ICCs for intra-rater reliability were excellent, ranging from 0.751-0.940 in brain regions except the right occipital, left anterior cingulate, and left and right cerebellum (ICCs = 0.65-0.741). Although ICCs for inter-rater reliability were fair to excellent in most regions, poor inter-rater correlations were observed for the cingulate and occipital regions. Processing time, including manual skull stripping, was $17.07{\pm}3.43min$. Z-score maps for all participants indicated that cortical thicknesses were not significantly different from those in the comparison databases of healthy adults. Conclusion: BSIM-based cortical thickness measurements provide acceptable intra-rater and inter-rater reliability. We therefore suggest BSIM-based cortical thickness analysis as an adjunct clinical tool to detect cortical atrophy.

A Reliability Study of Tape and Photography Measurement Techniques for Scapular Position (줄자 및 사진촬영 측정을 이용한 어깨뼈 벌림 측정에 대한 신뢰도 연구)

  • Kim, Moon-Hwan;Yun, Sung-Joon;Ha, Sung-Min
    • Physical Therapy Korea
    • /
    • v.20 no.3
    • /
    • pp.74-80
    • /
    • 2013
  • The purpose of this study was to determine the reliability of distance measurements from the medial border of the scapula to the spinous process of the thoracic vertebrae when obtained using tape and photography measurements. The study included 20 healthy subjects (10 males, 10 females); for a total of 40 scapula measurements. The distance measurements made using tape or photography methods were conducted with the subject in a standing position. Repeated tape and photography measurements were conducted in two sessions on different days by two examiners to assess the inter-rater and intra-rater reliability of the two methods. The reliability of scapular distance measured using tape and photography methods was tested using intraclass correlation coefficients (ICC(3,1)) and the standard error of measurement (SEM). The inter-rater reliability of the tape measurement method was excellent (ICC=.77) and the intra-rater reliability was fair to good (ICC=.74). The inter-rater and intra-rater reliabilities of the photography measurement method were excellent (ICC=.76 and .76 respectively). Our results suggest that photography measurement is an objective and qualitative measurement tool for scapular distance measurements.

Inter-Rater Reliability of the Gross Motor Function Measure (대동작 측정도구의 측정자간 신뢰도)

  • Yi, Chung-Hwi;Hwang, Seon-Gwan;Choi, Houng-Sik
    • Physical Therapy Korea
    • /
    • v.2 no.1
    • /
    • pp.1-13
    • /
    • 1995
  • The purpose of this study was to examine the inter-rater reliability of the Korean translation of the GMFM(Gross Motor Function Measure). Three licensed physical therapists with varying amounts(2 - 6 years) of clinical experience served as raters. Thirty patients with cerebral palsy were subjects for this study. Subjects were 22 boys and 8 girls, aged 1 to 8 years. Reliability of each dimension and each total score of the GMGM were analyzed using ICCs(intraclass correlation coefficients). The reliability of each dimension score ranged from .76 to .98, with the walking, running, and jumping dimension having higher reliability values. The reliability of the total dimension score was .94. We conclude that the GMFM has inter-rater reliability for assessing gross motor function in patients with cerebral palsy.

  • PDF

The reliability of dual rehabilitative ultrasound imaging measurements for muscle co-activation

  • Hahn, Joohee;Ha, Hyun-Geun;Lee, Hwang-Jae;Lim, Seungyeop;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.3
    • /
    • pp.152-157
    • /
    • 2017
  • Objective: The aim of this study was to determine the intra-rater and inter-rater reliability of the dual rehabilitative ultrasound imaging (D-RUSI) when simultaneously measuring muscle thickness changes at rest and during co-contraction of the biceps brachii (BB) and triceps brachii (TB). Design: Cross-sectional study. Methods: This study included 36 healthy participants (23 men, 13 women). The participants sat on a chair in a comfortable position with a cushion placed under their elbow to maintain a 90-degree elbow flexion angle. The muscle thickness of the biceps brachii and triceps brachii was measured twice using the D-RUSI by two examiners during resting and co-contraction states. One week later, the same procedure was performed once again. Results: The intra-class correlation coefficients (ICCs) for intra-rater reliability ranged from 0.887 to 0.989 and the confidence interval was within an acceptable range of 0.778 to 0.994. The standard error of measurement (SEM) values ranged from 0.303 to 0.866 and the minimal detectable change (MDC) values ranged from 0.84 to 2.40. The ICCs for inter-rater reliability ranged from 0.758 to 0.925. The SEM values ranged from 0.702 to 1.486 and the MDC values ranged from 1.95 to 4.12. Conclusions: The use of the D-RUSI of the BB muscle had a very good intra-rater reliability and very good inter-rater reliability at the resting state, and a, good inter-rater reliability at the co-activation state. ICC values showed very good intra-reliability and inter-reliability for the TB muscle. the D-RUSI is a useful tool for simultaneously measuring the thickness of two muscles when the BB is an agonist and the TB is an antagonist during co-activation of the upper arm.

Inter-Rater Reliability of the Korean Triage and Acuity Scale (한국형 응급환자 분류도구의 간호사-응급구조사 간 신뢰도 평가)

  • Son, Jeong Ah;Lee, Eun Ja
    • Journal of Korean Clinical Nursing Research
    • /
    • v.26 no.1
    • /
    • pp.107-116
    • /
    • 2020
  • Purpose: This study was a prospective survey to evaluate the Korean Triage and Acuity Scale (KTAS) inter-rater reliability and to identify discordant areas in the KTAS classification between nurses and paramedics in emergency department (ED). Methods: Inter-rater reliability were evaluated using triage deta from January 11 to May 31, 2019. A convinience sample of a total of 800 patients who visited an emergnecy medical center in Incheon (400 adult and 400 pediatric patients in this study) were selected. The triages of this study a pair of one nurse and one paramedic performed triage at the same time, using the KTAS, Inter-rater reliability for the KTAS was evaluated with the weighted kappa. Results: The inter-rater reliability of the KTAS evaluated by weighted Kappa between nurse-paramedic KTAS score of adult patients was .71, and .66 for pediatric patients. Both were in the level considered as substantial. Among causes of triage discordance, the most frequently identified discordant item in triaging adults was the difference in the measurement of pain intensity (28.0%). For both adult and pediatric patients, multiple chief complaint was identified as the major discordant factor. In triaging pediatric patients the body temperature assessment by subjective judgments was the highest discordant item (50.7%). Conclusion: The study result suggested that the KTAS demonstrated a reasonable level of inter-rater reliability and functioned as a standardized triage tool for emergency medical services. In order to improve the inter-rater reliability and classification competence, it is necessary to revise the current all-integrated KTAS provider course to be differentiated for each job group.

Reliability study of the Pectoralis Minor Muscle Thickness Measurement using Rehabilitative Ultrasound Imaging

  • Lim, Ji Young;Lee, Se-Yeong;Jung, Seung-Hwa;Park, Dae-Sung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.2
    • /
    • pp.45-52
    • /
    • 2021
  • PURPOSE: This study examined the imaging procedure of pectoralis minor muscle thickness and assessed the intra- and inter-rater reliability of the muscle thickness measured by two raters using rehabilitative ultrasound imaging (RUSI) in healthy individuals. METHODS: Fifteen participants (aged 21 - 28, seven females, and eight males) were involved in the study. The primary rater palpated the coracoid process and the fourth rib, defined as the width of the index finger lateral to the sternum to avoid breast tissues, and lined the two landmarks. The second examiner checked 1 / 3 (1st point) and 1 / 2 (2nd point) of the line length as measurement points. The two raters obtained right side muscle images of the participants at a standardized sitting position using RUSI with a 7.5 MHz linear transducer at 40mm depth. For intra-rater reliability, the principal rater took three images per point and tried to take one more with an interval. For the inter-rater reliability, the other rater performed the same tasks as the principal rater on the same day. The reliability was analyzed using the intra-class correlation coefficient (ICC), the standard error of the measurement (SEM), and Bland and Altman plots. RESULTS: The reliability at all points was excellent for the same rater (ICC3,1 = .973 - .978, SEM = .042 - .046), and between raters (ICC2,1 = .939 - .959, SEM = .059 - .097). CONCLUSION: These findings show that the RUSI could be reliable for examining the pectoralis minor muscle thickness in healthy individuals at all measurement sites.

Reliability of rehabilitative ultrasound imaging for measuring the gluteus maximus muscle at rest and during contraction

  • Jeong, Ju-Ri;Lee, Su-Jin;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.1
    • /
    • pp.7-13
    • /
    • 2017
  • Objective: The aim of this study was to investigate the inter-rater and intra-rater reliability of rehabilitative ultrasound imaging (RUSI) for measurement of muscle thickness with changes in angles of the gluteus maximus (GM) at rest and during contraction. Design: Cross-sectional study. Methods: Twenty-two healthy men volunteered for this study. GM muscle images were obtained in the resting position and during prone hip extension with knee flexion at hip abduction angles of $0^{\circ}$ and $30^{\circ}$, respectively. Two examiners randomly measured the thickness of the GM twice in three different positions. The first position was a comfortable prone position. The second position was prone hip extension with knee flexion (PHEKF) to $90^{\circ}$. The third position was achieved by hanging a 1-kg weight on the ankle of the lifted leg during PHEKF with the angle of the lifted leg the same as the second position. Intra-class correlation coefficients (ICCs), standard error measurements, and minimal detectable changes were used to estimate reliability. Results: The intra-rater reliability ICCs (95% confidence interval) of the GM were >0.870, indicating good reliability. Inter-rater reliability ICCs ranged from 0.668 to 0.913. The reliability of measurements of muscle thickness at each position was similar to the reliability of the angle change. Differences in muscle thickness and ratios for each position with $0^{\circ}$ and $30^{\circ}$ of hip abduction were not statistically significant. Conclusions: In the present study, the intra-rater reliability of muscle thickness measurements of the GM was good, and the inter-rater reliability was moderate to good. Reliable RUSI measurements of wide and large muscles, such as the GM muscle at rest and during contraction, are feasible. Further investigation is required to establish the reproducibility of the protocols presented in this study.

Intra- and Inter-rater Reliability of BioRescue (BioRescue의 측정자내와 측정자간 신뢰도)

  • Kim, Jin-hong;Choi, Bo-ram
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.11
    • /
    • pp.348-352
    • /
    • 2018
  • BioRescue ($RMIng{\acute{e}}nierie$, Marseille, France) is able to assess dynamic and static balance when a test subject stands or sits over the platform. Although previous studies have examined the reliability of other balance measurement methods, little research has been conducted on the reliability of equipment such as BioRescue. This study examined the intra-rater and inter-rater reliability of BioRescue during balance assessment. Thirty-four healthy adults participated as subjects and two physical therapists participated as examiners to determine intra- and inter-rater reliability. BioRescue was used to conduct measurements during footprint (area and pressure), Romberg, and limit of stability tests. The footprint area and limit of stability tests yielded intra- and inter-rater reliability ICC values above 0.60 in all directions. However, the footprint pressure and Romberg tests yielded values below 0.60 in all directions. BioRescue showed good inter-rater and intra-rater reliability in measurements during footprint area and limit of stability tests. However, because the values of limits of stability show the difference between experienced and unskilled, skill is required for the accuracy of the equipment.

Intra-Rater and Inter-Rater Reliability of Various Forward Head Posture Measurements

  • Yoo, Won-Gyu;Kim, Min-Hee;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.12 no.4
    • /
    • pp.41-47
    • /
    • 2005
  • The purpose of this study was to determine the intra-rater and inter-rater reliability of various forward head posture measurements. Ten healthy adults (age, $20.4{\pm}2.2$ yrs; height, $164.0{\pm}5.5$ cm; weight, $58.7{\pm}7.3$ kg) participated in the study. They were free of injury and neurologic deficits in the upper extremities and neck at the time of testing. The subjects were asked to perform head forward posture by under the guidance of physical therapists. Markers were placed on the C7 spinous process, mastoid process, tragus of the ear, outer canthus, and forehead. Measurement 1 for forward head posture assessment was measured as the angle between the horizontal line through C7 and the line connecting the C7 spinous process with the tragus of the ear. Measurement 2 was measured as the angle between the C7 spinous process, the mastoid process and the outer canthus. Measurement 3 was measured as two kinds of angles the HT (head tilt) angle is between the line from the midpoint of forehead to the tragus line and Y-axis at the tragus point. The NF (neck flexion) angle is between the line from the tragus to the C7 line and the Y-axis at the C7. Intra-rater, inter-rater reliability and coefficient of variation was assessed by comparing the measured values from three kinds of measurements of forward head posture. The intra-rater reliability was indicated by intraclass correlation coefficients [ICC(1,1)] and inter-rater reliability was shown by intraclass correlation coefficients [ICC(3,k)]. The results of study were as follows: ICC(1,1) values for intra-rater reliability of three measurements were in the 'excellent' category. ICC(3,k) values for inter-rater reliability of three measurements were also in the 'excellent' category. The coefficient of variation of method 2 had a lower value than method 1 and method 3. This data means that the measured value of method 2 was less scattered. Further research is needed to determine whether the validity of all measurements is revealed in the 'excellent' category.

  • PDF