The purpose of this study was to investigate the reliability and validity of goniometer measurements of the hallux valgus angle (HVA) compared to radiographic measurements, which are the current standard. Twenty subjects (10 female, 10 male) were recruited for this study (40 feet). The HVA of the subjects was measured using goniometer and radiographic measurement. In three trials, measurements were taken of each subject by two examiners using goniometer and radiographic measurements using radiography in a standing position. The reliability of the measurements was investigated using intraclass correlation coefficients (ICC(3,1)), and the validity was tested using the Pearson product-moment correlation coefficient and an independent t-test. The intra-rater reliability of left and right HVAs were poor (ICC=.409 and .341, respectively). The inter-rater reliability of left and right HVAs were poor and moderate (ICC=.303 and .501, respectively). Left and right HVAs measured using goniometer and radiographic measurements were also poor and moderate (Pearson r=.246 and .544, respectively). These results suggest that goniometer measurements of the HVA are inaccurate and have unacceptable validity compared to radiographic measurements.
Purpose: The purpose of this study was to develop and establish the psychometric properties of a clinical nursing competency evaluation tool to be utilized by clinical preceptors. Methods: The initial items were identified through in-depth literature review and field interviews based on a hybrid model. Content validation of the items was evaluated through three rounds of content validity testing. Participants were 34 clinical preceptors and 443 nursing students participating in clinical practice. Data were analyzed using exploratory and confirmatory factor analysis, convergence and discriminant validity, internal consistency and inter-rater reliability. Results: The final scale consisted of 23 items and four factors, fundamental nursing skills performance, critical thinking skills based on the nursing process, basic nursing knowledge, and professional attitude; these factor explained 69.7% of the total variance. The analysis with multi-trait/multi-item matrix correlation coefficients yielded 100.0% and 95.7 % convergence and discriminant validity, respectively. Cronbach's alpha for the total items was .95. The four subscale model tested by confirmatory factor analysis was satisfactory. Inter-rater reliability ranged from .912 to .967. Conclusion: This scale was found to be a reliable and valid instrument that clinical preceptors can apply for evaluating the clinical nursing competency of nursing students in clinical settings.
Purpose: To develop outcome indicators of urinary incontinence to measure quality of care in long term care hospitals in Korea. Methods: The draft indicators of urinary incontinence were developed from a literature review and clinical expert panel. A survey of medical records of 280 patients in 20 hospitals was conducted to test inter-rater reliability. Statistical analysis was done to test risk adjustment criteria, variation between hospitals, and stability of indicators, using assessment data from 77,918 patients in 623 hospitals. Results: The inter-rater reliability of items was high (Kappa range: 0.66- 0.92). Severe cognitive impairment (odds ratio [OR]: 3.15, confidence interval [CI]: 3.03-3.26) and total mobility activities of daily living (ADLs) dependency (OR: 4.85, CI: 4.72-4.98) increased the prevalence of urinary incontinence, thus they proved to be significant criteria to stratify high and low risk groups. The prevalence for low risk showed more substantial variation than the high risk group. The indicators were stable over one month. Conclusion: This study demonstrated the feasibility of outcome indicators of urinary incontinence. Improving the reliability of the patient assessment tool and refining the indicators through validation study is a must for future study.
This study explored the perception of transplanted English prosody by thirty American and Korean, male and female listeners. The English utterances of various sentence types produced by Korean and American male speakers were employed to transplant the American prosody contours to Korean English utterances. Then, the thirty subjects were instructed to rate the transplanted prosodic components. Results showed that the interactions between the three factors (e.g., rater groups & transplantation types; transplantation types & sentence types; rater groups & transplantation types & sentence types) turned out to be meaningful. Both Americans and Koreans perceived the effectiveness of the combined effect of transplanted duration and pitch or duration and pitch and intensity. However, when perceiving individual prosodic components, Americans and Koreans showed different perceptual ratings. As for the overall prosody change, Americans perceived the change of intensity in a significant way but Koreans did not because intensity is not a crucial semantic factor in Korean. Americans rated the transplantation of duration alone as ineffective while Koreans rated otherwise. This was explained by the difference between English and Korean. The difference of perspective was also significant with different sentence types, especially with the three sentence types that had speech rates slower than other sentence types. A slower speech rate intensified the mismatch between the transplanted duration and the original pitch causing a negative impression on American listeners whereas this did not affect Korean listeners. Pedagogical implications of the findings are discussed.
Purpose: The purpose of this study was to determine the reliability and validity of the Functional Movement Screen (FMS) for assessing Korean athletes. Methods: A total of 48 patients (37 males and 11 females) participated in this study. Data were acquired after translation of the FMS from English to Korean and cross-cultural adaptation of the this questionnaire. To determine inter-rater reliability, the relationship between the FMS scores obtained by two raters was evaluated using the Kappa coefficient, which was in total agreement with the Intra-Correlation Coefficient (ICC3,1). Concurrent validity was examined by correlating the FMS scores with the Oswestry disability index (ODI) scores and Visual analogue scale (VAS) scores. Results: The raters demonstrated excellent agreement on 7 (above 90%) of the 17 test (72.9 to 97.9%) components. Substantial agreement was seen in 11 of the 17 tests. Two components of the In-line lunge and rotatory stability tests demonstrated moderate agreement. It showed good inter-rater reliability: the Kappa coefficients ranged from 0.42 to 0.97. ICC3,1=0.42~0.99 and 0.93 (total FMS score). Cronbach's alpha for FMS was 0.80. It was not correlated with ODI or VAS. Conclusion: The Korean version of the FMS is a reliable instrument for measuring movement patterns of Korean athletes and for making decisions related to interventions for performance enhancement.
About 3.9 million apps and 24 primary categories can be approved on Apple iTunes Store. Making accurate categorization can potentially receive many benefits for developers, app stores, and users, such as improving discoverability and receiving long-term revenue. However, current categorization problems may cause usage inefficiency and confusion, especially for cross-attribution, etc. This study focused on evaluating the reliability of app categorization on Apple iTunes Store by using several rounds of inter-rater reliability statistics, locating categorization problems based on Machine Learning, and making more accurate suggestions about representative functionality stems for each primary category. A mixed methods research was performed and total 4905 popular apps were observed. The original categorization was proved to be substantial reliable but need further improvement. The representative functionality stems for each category were identified. This paper may provide some fusion research experience and methodological suggestions in categorization research field and improve app store's categorization in discoverability.
Proceedings of the Korean Society of Broadcast Engineers Conference
/
2009.01a
/
pp.655-658
/
2009
Fractal dimension has been used for texture analysis as it is highly correlated with human perception of surface roughness and applied to quantifying the structures of wide range of objects in biology and medicine. On the other hand, the evaluation of the human skin state is based solely on the subjective assessment of clinicians; this assessment may vary from moment to moment and from rater to rater. Therefore we attempt to analysis of skin texture image using fractal dimension and discuss its application to evaluating human skin state. It can be helpful for extracting human features and also can be useful for detection of many human skin diseases. This paper presents a method to calculate fractal dimension of skin with use of camera lens magnification. We take multiple pictures frequently from skin with different camera lens magnification as a magnification factor of fractal set, and counting the number of objects (cells) in each picture as a number of self similar pieces of fractal set.
Kim, Jung-Yeon;Cha, Ye-Rin;Lee, Sang-Heon;Jung, Bong-Keun
KSII Transactions on Internet and Information Systems (TIIS)
/
v.11
no.2
/
pp.1201-1216
/
2017
In this study, we described the development of a methodology to measure tip-pinch strength on the paretic hand rehabilitation device and aimed to investigate reliability of the device. FSR sensors were embedded on the device, and tip pinch strength was estimated with data collected from the sensors using a developed equation while participants were demonstrating tip pinch. Reliability tests included inter-rater, test-retest, and inter-instrument reliability. B&L Engineering pinch gauge was utilized for the comparison. Thirty-seven healthy students participated in the experiment. Both inter-rater and test-retest reliability were excellent as Intraclass Correlation Coefficients (ICCs) were greater than 0.9 (p<0.01). There were no statistically significant differences in tip-pinch strengths. Inter-instrument reliability analysis confirmed good correlation between the two instruments (r = 0.88, p < 0.01). The findings of this study suggest that the two instruments are not interchangeable. However, the tip-pinch mechanism used in the paretic hand rehabilitation device is reliable that can be used to evaluate tip pinch strength in clinical environment and can provides a parameter that monitors changes in the hand functions.
We propose a new method for automatic fluency scoring of English speaking tests spoken by nonnative speakers in a free-talking style. The proposed method is different from the previous methods in that it does not require the transcribed texts for spoken utterances. At first, an input utterance is segmented into a phone sequence by using a phone recognizer trained by using native speech databases. For each utterance, a feature vector with 6 features is extracted by processing the segmentation results of the phone recognizer. Then, fluency score is computed by applying support vector regression (SVR) to the feature vector. The parameters of SVR are learned by using the rater scores for the utterances. In computer experiments with 3 tests taken by 48 Korean adults, we show that speech rate, phonation time ratio, and smoothed unfilled pause rate are best for fluency scoring. The correlation of between the rater score and the SVR score is shown to be 0.84, which is higher than the correlation of 0.78 among raters. Although the correlation is slightly lower than the correlation of 0.90 when the transcribed texts are given, it implies that the proposed method can be used as a preprocessing tool for fluency evaluation of speaking tests.
Journal of the Korean Data and Information Science Society
/
v.23
no.1
/
pp.25-37
/
2012
Many statistics, such as Cohen's (1960) ${\kappa}$, Scott's (1955) ${\pi}$, and Park and Park's (2007) H have been proposed as measures of agreement to represent inter-rater reliability. This study compared bias, SE, MSE, and CV of the measures of agreement with nominal and ordinal categories in the balanced marginal distributions, and those with nominal categories in the two paradoxical situations. As a result, in all cases, AC1and Hhad smaller SE and CV.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.