• Title/Summary/Keyword: Rated voltage

Search Result 398, Processing Time 0.022 seconds

Fabrication and Test of the Three-Phase 6.6 kV Resistive Superconducting Fault Current Limiter Using YBCO Thin Films (YBCO 박막을 이용한 3상 6.6kV 저항형 초전도 한류기 제작 및 시험)

  • Sim J.;Kim H. R.;Park K. B.;Kang J. S.;Lee B. W.;Oh I. S.;Hyun O. B.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.3
    • /
    • pp.50-55
    • /
    • 2004
  • We fabricated and tested a resistive type superconducting fault current limiter (SFCL) of three-phase 6.6 $kV_{rms}/200 A_{rms}$ rating based on YBCO thin films grown on sapphire substrates with a diameter of 4 inches, Short circuit tests were carried out at a accredited test facility for single line-to- ground faults, phase-to-phase faults and three-phase faults, Each phase of the SFCL was composed of 8${\times}$6 elements connected in series and parallel respectively. Each element was designed to have the rated voltage of 600 $V_{rms}$. A NiCr shunt resistor of 23 Ω was connected to each element for simultaneous quenches. Firstly, single phase-to-ground fault tests were carried out. The SFCL successfully developed the impedance in the circuit within 0.12 msec after fault and controlled the fault current of 10 $kA_{rms} below 816 A_{peak}$ at the first half cycle. In addition, in case of phase-to-phase fault and three- phase fault test. simultaneous quenches among the SFCLs of the phases successfully accomplished. In conclusion. the SFCL showed excellent performance of current limitation upon fault and stable operation regardless of the amplitude of fault currents.

Maximum Torque Control of IPMSM with Adoptive Leaning Fuzzy-Neural Network (적응학습 퍼지-신경회로망에 의한 IPMSM의 최대토크 제어)

  • Chung, Dong-Hwa;Ko, Jae-Sub;Choi, Jung-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.32-43
    • /
    • 2007
  • Interior permanent magnet synchronous motor(IPMSM) has become a popular choice in electric vehicle applications, due to their excellent power to weight ratio. This paper proposes maximum torque control of IPMSM drive using adaptive learning fuzzy neural network and artificial neural network. This control method is applicable over the entire speed range which considered the limits of the inverter's current and voltage rated value. This paper proposes speed control of IPMSM using adaptive learning fuzzy neural network and estimation of speed using artificial neural network. The back propagation neural network technique is used to provide a real time adaptive estimation of the motor speed. The proposed control algorithm is applied to IPMSM drive system controlled adaptive learning fuzzy neural network and artificial neural network, the operating characteristics controlled by maximum torque control are examined in detail. Also, this paper proposes the analysis results to verify the effectiveness of the adaptive learning fuzzy neural network and artificial neural network.

Characteristic Analysis of a Ex Circuit of Ex LED Signal Lamp Operating with AC/DC 12~254 V (AC/DC 12~254 V로 동작하는 방폭 LED Signal Lamp용 방폭 회로의 특성 분석)

  • Jeong, Min-Joo;Her, In-Sung;Kang, In-Cheol;Yu, Young-Moon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.11
    • /
    • pp.690-695
    • /
    • 2014
  • In this paper, we develop a explosion-proof LED lighting (Ex circuit) circuit of Explosion-proof LED Signal Lamp (Ex LSL) to utilize the core module of the explosion-proof Local Control System (Ex LCS) for offshore plant applications. And then analyzed its electrical, optical and thermal characteristics. Ex circuit was applied input voltage from AC/DC(12~254) V. In this experiments, stable light-on characteristics were confirmed by eyes for the every input voltages with min. 78,462 and max. $517,975cd/m^2$ of luminance. also Output current and output luminance was made proportional. Because the measured maximum surface temperature of Ex circuit was $54.23^{\circ}C$ at AC 48 V, Ex circuit was rated with T6 of temperature class. Finally, Ex circuit was shown stable light on characteristics under the $-50^{\circ}C$ and $60^{\circ}C$ during 12 hours of test period.

Analysis of Ignition Time/Current Characteristics and Energy when Series Arc-Fault Occurs at Rated 220 V (220 V 직렬 아크고장발생 시 점화 시간/전류 특성 및 에너지 분석)

  • Ko, Won-Sik;Moon, Won-Sik;Bang, Sun-Bae;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1184-1191
    • /
    • 2013
  • Probability of ignition due to arc-fault and energy of the arc-fault for the case of applying serial arc-fault interruption time of 120 V defined in UL 1699 to the voltage of 220 V of domestic condition and also for the case of applying it to the HIV wire type are analyzed. It has been confirmed that when the arc-fault occurs under 5 A, 10 A, and 20 A. Probability of ignition for the three different current conditions is 0.74(74%), 0.48(48%), and 0.32(32%) respectively for respective interruption time within 1 sec, 0.4 sec, and 0.2 sec. We discover that when we apply the same arc interruption time for 120 V defined in UL 1699 to the domestic environment of 220 V. The probability of ignition increases from 1.5% for 120 V condition to as much as 74% for 220 V condition. Conclusively, if we apply the standard for the serial arc-fault interruption time defined in UL 1699 for 120 V to the domestic condition of 220 V, the fire prevention effect of electric fire due to arc-fault equal to that of UL standard of 120 V can not be achieved.

A Study on Selecting the Optimal Location of BTB HVDC for Reducing Fault Current in Metropolitan Regions Based on Genetic Algorithm Using Python (Python을 이용한 유전 알고리즘 기반의 수도권 고장전류 저감을 위한 BTB HVDC 최적 위치 선정 기법에 관한 연구)

  • Song, Min-Seok;Kim, Hak-Man;Lee, Byung Ha
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.8
    • /
    • pp.1163-1171
    • /
    • 2017
  • The problem of fault current to exceed the rated capacity of a power circuit breaker can cause a serious accident to hurt the reliability of the power system. In order to solve this issue, current limiting reactors and circuit breakers with increased capacity are utilized but these solutions have some technical limitations. Back-to-back high voltage direct current(BTB HVDC) may be applied for reducing the fault current. When BTB HVDCs are installed for reduction in fault current, selecting the optimal location of the BTB HVDC without causing overload of line power becomes a key point. In this paper, we use genetic algorithm to find optimal location effectively in a short time. We propose a new methodology for determining the BTB HVDC optimal location to reduce fault current without causing overload of line power in metropolitan areas. Also, the procedure of performing the calculation of fault current and line power flow by PSS/E is carried out automatically using Python. It is shown that this optimization methodology can be applied effectively for determining the BTB HVDC optimal location to reduce fault current without causing overload of line power by a case study.

Comparison of Quality Control for Chest Radiography between Special Examination and Medical Institution for Pneumoconiosis (진폐 정밀/요양기관과 요양기관의 흉부 방사선분야 정도관리 비교)

  • Lee, Won-Jeong
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.2
    • /
    • pp.322-330
    • /
    • 2011
  • To compare of quality control for chest radiography between special examination (SEP) and medical institution for pneumoconiosis (MIP). For the first time, we had visited at 33 institutions (SEP; 17 institutions, MIP; 16 institutions) to evaluate the quality control of chest radiography which is used in diagnosis of patients with pneumoconiotic complications. Image quality was rated by two experienced chest radiologists, and evaluated for radiological technique (RT), reading environment (RE) and image quality (IQ) between SEP and MIP according to the guideline published by OSHRI. Generator capacity, used duration and modality of chest radiography equipment were not signigicant difference between SEP and MIP, but there were signigicant difference in tube voltage and grid ratio used for chest radiography except to tube current and exposure time. SEP was statistically significant higher in RT (71.2 vs. 54.5, p=0.015), RE (78.8 vs. 51.5, p=0.007) to MIP, but not significant difference in IQ (64.8 vs. 59.3, p=0.180). For reliable and precisional diagnosis of patients with pneumoconiotic complications, the MIP requires the evaluation and education of quality control for improving chest radiography.

Development of 80kW Bi-directional Hybrid-SiC Boost-Buck Converter using Droop Control in DC Nano-grid (DC 나노그리드에서 Droop제어를 적용한 80kW급 양방향 하이브리드-SiC 부스트-벅 컨버터 개발)

  • Kim, Yeon-Woo;Kwon, Min-Ho;Park, Sung-Youl;Kim, Min-Kook;Yang, Dae-Ki;Choi, Se-Wan;Oh, Seong-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.360-368
    • /
    • 2017
  • This paper proposes the 80-kW high-efficiency bidirectional hybrid SiC boost/buck converter using droop control for DC nano-grid. The proposed converter consists of four 20-kW modules to achieve fault tolerance, ease of thermal management, and reduced component stress. Each module is constructed as a cascaded structure of the two basic bi-directional converters, namely, interleaved boost and buck converters. A six-pack hybrid SiC intelligent power module (IPM) suitable for the proposed cascaded structure is adopted for high-efficiency and compactness. The proposed converter with hybrid switching method reduces the switching loss by minimizing switching of insulated gate bipolar transistor (IGBT). Each module control achieves smooth transfer from buck to boost operation and vice versa, since current controller switchover is not necessary. Furthermore, the proposed parallel control using DC droop with secondary control, enhances the current sharing accuracy while well regulating the DC bus voltage. A 20-kW prototype of the proposed converter has been developed and verified with experiments and indicates a 99.3% maximum efficiency and 98.8% rated efficiency.

Heat transfer monitoring between quenched high-temperature superconducting coated conductors and liquid nitrogen

  • Rubeli, Thomas;Colangelo, Daniele;Dutoit, Bertrand;Vojenciak, Michal
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.1
    • /
    • pp.10-13
    • /
    • 2015
  • High-temperature superconducting coated conductors (HTS-CCs) are good candidates for resistive superconducting fault current limiter (RSFCL) applications. However, the high current density they can carry and their low thermal diffusivity expose them to the risk of thermal instability. In order to find the best compromise between stability and cost, it is important to study the heat transfer between HTS-CCs and the liquid nitrogen ($LN_2$) bath. This paper presents an experimental method to monitor in real-time the temperature of a quenched HTS-CC during a current pulse. The current and the associated voltage are measured, giving a precise knowledge of the amount of energy dissipated in the tape. These values are compared with an adiabatic numerical thermal model which takes into account heat capacity temperature dependence of the stabilizer and substrate. The result is a precise estimation of the heat transfer to the liquid nitrogen bath at each time step. Measurements were taken on a bare tape and have been repeated using increasing $Kapton^{(R)}$ insulation layers. The different heat exchange regimes can be clearly identified. This experimental method enables us to characterize the recooling process after a quench. Finally, suggestions are done to reduce the temperature increase of the tape, at a rated current and given limitation time, using different thermal insulation thicknesses.

Evaluation of a FPGA controlled distributed PV system under partial shading condition

  • Chao, Ru-Min;Ko, Shih-Hung;Chen, Po-Lung
    • Advances in Energy Research
    • /
    • v.1 no.2
    • /
    • pp.97-106
    • /
    • 2013
  • This study designs and tests a photovoltaic system with distributed maximum power point tracking (DMPPT) methodology using a field programmable gate array (FPGA) controller. Each solar panel in the distributed PV system is equipped with a newly designed DC/DC converter and the panel's voltage output is regulated by a FPGA controller using PI control. Power from each solar panel on the system is optimized by another controller where the quadratic maximization MPPT algorithm is used to ensure the panel's output power is always maximized. Experiments are carried out at atmospheric insolation with partial shading conditions using 4 amorphous silicon thin film solar panels of 2 different grades fabricated by Chi-Mei Energy. It is found that distributed MPPT requires only 100ms to find the maximum power point of the system. Compared with the traditional centralized PV (CPV) system, the distributed PV (DPV) system harvests more than 4% of solar energy in atmospheric weather condition, and 22% in average under 19% partial shading of one solar panel in the system. Test results for a 1.84 kW rated system composed by 8 poly-Si PV panels using another DC/DC converter design also confirm that the proposed system can be easily implemented into a larger PV power system. Additionally, the use of NI sbRIO-9642 FPGA-based controller is capable of controlling over 16 sets of PV modules, and a number of controllers can cooperate via the network if needed.

Aging Analysis of Self Hooting MPPF Capacitor Elements (셀프힐링 금속증착 커패시터 소체의 열화 분석)

  • 곽희로;송길목;김영찬
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.73-79
    • /
    • 2003
  • This paper describes the characteristics of capacitor elements at self healing. Self healing events were forced to be created by the over-rated voltage of the capacitor elements. The self healing site was photographed by the Scanning Electron Microscope and the by-products of self healing were analyzed by the Energy Dispersive X-ray Spectrometer. Also the self healing site was analyzed by the Differential Scanning Calorimeter and the Fourier Transform Infrared Spectrometer. As a result, the main component of by-products due to the hum cut at self healing was carbon. The Fourier Transform Infrared analysis result of the self-healing specimen was similar to that of the virgin specimen, however, different from that of the specimen thermally treated at 500$^{\circ}C$. It was observed that heat flow peaks of virgin specimen were different from self-healing specimen by the Differential Scanning Calorimeter analysis.