• Title/Summary/Keyword: Rated output

Search Result 272, Processing Time 0.029 seconds

A Study and Development of the Wind Turbine System for Rated Revolutions and Rated Output using Fluid Torque Converter (유체 토크 컨버터를 이용한 정회전 정출력 풍력발전시스템 연구 및 개발)

  • Yi, In-Yol;Lee, Kang-Il;Shim, Choong-Moo;Choi, Dae-Kue;Lim, Jae-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.11
    • /
    • pp.40-47
    • /
    • 2012
  • Most of existing wind turbine system is used with geared type; however, this type has lots of problems which are noisy, weight, maintenance and so on. In this paper, wind turbine system with fluid torque converter applied to solve these problems. In case of the proposed wind turbine system, it is possible to transmit torque to adaptable distance. So various sets including generator, inverter and auxiliary motor move from the nacelle to the ground. As a result, Total weight in Nacelle can be decreased. however, the efficiency can be decreased with fluid torque system. We also applied auxiliary motor to fluid torque system. So, we also realized rated revolutions and rated output windturbine and could get considerable good data.

Power Analysis & Rated Power Control Method of DFIG for Wind Power Generating (풍력발전용 DFIG의 출력 해석과 정격출력 제어)

  • Lee, Jean-Ho;Lee, Woo-Suk;Seo, Young-Taek;Oh, Chul-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.111-114
    • /
    • 1999
  • This paper deals with the rated output power using grid-connected Doubly-Fed Induction Generator(DFIG) in the supersynchronous speed regions. The rated output power is controlled by both magnitude and frequency of the voltage fed to the rotor. And this rotor voltage is controlled by control of inverter switching frequency and fire angle. A DFIG generating characteristic is analyzed by simulation of steady-state algebraic equation of equivalent circuit using numerical analysis. And it is compared with results of experiment. Consequently, This paper presented to control method for rated output power of DFIG in variable wind speed.

  • PDF

Development of 6-axis Ankle Force/Moment Sensor for an Intelligent Foot of a Humanoid Robot (인간형 로봇의 지능형 발을 위한 6축 발목 힘/모멘트센서)

  • Kim, Gab-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.1 s.190
    • /
    • pp.27-36
    • /
    • 2007
  • This paper describes the development of 6-axis ankle force/moment sensor for the intelligent feet of a humanoid robot. When the robot walks on uneven terrain, the feet should perceive the applied forces Fx, Fy, Fz and moments Mx, My, Mz from the attached 6-axis force/moment sensor on their ankles. Papers have already been published have some disadvantages in the size of the sensor, the rated output and so on. The rated output of each component sensor (6-axis ankle force/moment sensor) is very important to design the 6-axis force/moment sensor for precision measurement. Therefore, each sensor should be designed to get the similar rated output under each rated load. Also, the size of the sensor is very important for mounting to robot's feet. Therefore, the diameter should be below 100 mm and the height should be below 40mm. In this paper, first, the structure of a 6-axis ankle force/moment sensor was modeled for a humanoid robot's feet newly, Second, the equations to predict the strains on the sensing elements was derived, third, the size of the sensing elements was designed by using the equations, then, the sensor was fabricated by attaching straingages on the sensing elements, finally, the characteristic test of the developed sensor was carried out. The rated outputs from the derived equations agree well with the results from the experiments. The interference error of the sensor is less than 2.94%.

Development of 6-axis force/moment sensor for an intelligent robot's foot (지능형 로봇 발을 위한 6 축 힘/모멘트센서 개발)

  • Kim, Gab-Soon;Shin, Hyi-Jun;Hu, Duk-Chan;Yoon, Jung-Won
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1097-1102
    • /
    • 2007
  • This paper describes the development of 6-axis force/moment sensor for an intelligent robot's foot. In order to walk on uneven terrain safely, the foot should perceive the applied forces Fx, Fy, Fz and moments Mx, My, Mz to itself. The applied forces and moments should be measured from a 6-axis force/moment sensor attached to a humanoid robot's foot(ankle). They in the published paper already have some disadvantage in the size of the sensor, the rated output and so on. The rated output of each component sensor (6-axis force/moment sensor) is very important to design the 6-axis force/moment sensor for precision measurement. Therefore, each sensor should be designed to be gotten similar the rated output under each rated load. So, the sensing elements of the 6-axis force/moment sensor should get lots of design variables. Also, the size of 6- axis force/moment sensor is very important for mounting to robot's foot. In this paper, a 6-axis force/moment sensor for perceiving forces and moments in a humanoid robot's foot was developed using many PPBs (parallel plate-beams). The structure of the sensor was newly modeled, and the sensing elements (plate-beams) of the sensor were designed using FEM (Finite Element Method) analysis. Then, the 6-axis force/moment sensor was fabricated by attaching strain-gages on the sensing elements, and the characteristic test of the developed sensor was carried out. The rated outputs from FEM analysis agree well with that from the characteristic test.

  • PDF

Field Test for Performance Evaluation of a Tubular Turbine in Marine Small Hydro Power Plant (해양소수력발전소 튜블러 수차 성능평가를 위한 현장시험)

  • Hwang, Yeong-Ho;Lee, Young-Ho;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1070-1077
    • /
    • 2011
  • This study includes field test results for performance evaluation of a tubular turbine in marine small hydro power plant. Minimum output power of the tested turbine generator is examined with using of the measured effective head, output power and efficiency. For the rated and maximum output power tests, corrected values from the result of turbine model test are used for the performance evaluation, because experimental conditions of field test at the rated and maximum output powers are restricted correctly. Performance of the test turbine shows good conformance with the suggested guarantee values of output power and efficiency at the measured points of minimum, rated and maximum output power.

Optimum Design Criteria Based on the Rated Watt of a Synchronous Reluctance Motor Using a Coupled FEM & SUMT (유한요소법과 SUMT를 이용한 동기형 릴럭턴스 전동기의 용량에 따른 회전자 구조 최적설계)

  • Kwon, Sun-Bum;Lee, Jung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.8
    • /
    • pp.364-369
    • /
    • 2005
  • This paper deals with an automatic optimum design based on a rated output for a synchronous reluctance motor (SynRM). The focus of this paper is the motor design relative to the output power on the basis of rotor shape of a SynRM in each rated watt. And optimization algorithm is used by means of sequential unconstrained minimization technique(SUMT). The coupled Finite Elements Analysis (FEA) & Preisach model have been used to evaluate nonlinear solutions. The proposed procedure allows to define the rotor geometric dimensions according to rated watt starting from an existing motor or a preliminary design.

A Novel Two Phase Interleaved LLC Series Resonant Converter using a Phase of the Resonant Capacitor

  • Yi, Kang-Hyun;Moon, Gun-Woo
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.275-279
    • /
    • 2008
  • An LLC series resonant converter has many unique characteristics and improvements over PWM topologies. However, many output capacitors are needed in parallel to satisfy output voltage ripple and the rated ripple current of the capacitors. This paper deals with a novel two phase interleaved LLC resonant converter using a phase of the resonant capacitor. The proposed converter can satisfy output voltage ripple and a rated ripple current of capacitors with few output capacitors, relatively. The operation and features are considered in detail and a prototype with a 12V-100A output is investigated.

Novel two phase interleaved LLC series resonant converter using a phase of the resonant capacitor

  • Yi, Kang-Hyun;Moon, Gun-Woo;Heo, Tae-Won
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.526-528
    • /
    • 2008
  • LLC series resonant converter has many unique characteristics and improvement over PWM topologies. However, many output capacitors should be needed in parallel to satisfy an output voltage ripple and a rated ripple current of the capacitors. This paper is deal with a novel two phase interleaved LLC resonant converter using a phase of the resonant capacitor. The proposed converter can satisfy output voltage ripple and a rated ripple current of capacitors with few output capacitors, relatively. The operation and features is considered in detail and a prototype with a 12V-100A output is investigated.

  • PDF

Output Voltage Disturbance Analysis for 100kw-Rated Outage and Phase Jump Generator (100kW급 순간정전 및 위상급변 발생기의 출력 전압변동 해석)

  • Nho, E.C.;Park, H.Y.;Kim, J.Y.;Kim, I.D.;Chun, T.W.;Kim, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.123-125
    • /
    • 2008
  • This paper deals with output voltage characteristics analysis of outage and phase jump generator. As soon as the outage occurs the STS(Solid Transfer Switch)s are switched off. At the beginning of the outage the DG is required to limit the reverse current within the rated DG output current. In case of phase jump the DG output voltage phase should be adjusted with PLL. Simulation results show the output voltage characteristics of the generator.

  • PDF

Optimal Capacity Determination of BESS for Customer using Investment Cost and Electric Cost (투자비용과 전기요금을 반영한 수용가 BESS의 최적용량 산정)

  • Park, Jin-Kyung;Baek, Young-Sik;Jeong, Ki-Seok;Park, Ji-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.208-213
    • /
    • 2015
  • This study presents the estimation method for the optimal capacity of BESS(Battery Energy Storage System) in order to reduce the electric charges of common consumer. The daily optimal charge and discharge plan of BESS which satisfies the given constraints is established using linear programming through the change of rated output/rated capacity of the time that shows the electric charges in the highest reduced rate has been selected. There will be a problem to compare only reduced rate because the bigger the rated capacity, the more reduced rate is increased. Therefore, rated output/rated capacity of the time when the reduced amount of electric charges for a year is higher than the investment cost of BESS was selected.