• 제목/요약/키워드: Rated load

검색결과 314건 처리시간 0.029초

Fuzzy Technique based Chopper Control for Slip Energy Recovery System with Twelve-Pulse Converter

  • Tunyasrirut, S.;Ngamwiwit, J.;Furuya, T.;Yamamoto, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.509-514
    • /
    • 2004
  • This paper introduces the modified slip energy recovery system in order to improve its power factor and to reduce harmonics of line current waveforms. Twelve pulse line commutated converter with the chopper type IGBT is applied where the chopper is applied across the DC terminal and the chopped DC is fed to the converter operating as an inverter and then passed through the wye-wye and delta-wye transformer circuit. This scheme leads to be able to adjust the speed of the motor by the duty cycle of the chopper operating in PWM mode. The fuzzy logic controller is also introduced to the modified slip energy recovery system for keeping the motor speed to be constant when the load varies. The experimental results in testing the 0.22 kW wound rotor induction motor from no-load condition to rated condition show the effectiveness of the proposed control scheme.

  • PDF

계통 연계형 인버터의 무효전력 공급을 고려한 Stack 설계 (The Stack Design Considering The Reactive Power Supply of Grid-Connected Inverter)

  • 고광수;오필경;김희중;김영민
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.453-454
    • /
    • 2016
  • The ESS(Energy Storage System) connected with distributed generation is drawing attention due to improving the quality load leveling, peak shaving for enhancing reliability of the power grid. The grid-connected inverter makes frequency adjustment to the active power's charge discharge according to the load variation. In addition, the inverter is possible to act as a reactive power compensation device to eliminate harmonic operates as power factor change inhibiting, anti-transient voltage fluctuation, active filter. In this paper, we propose a design method of igbt stack considering the reactive power supply capacity to improve the quality and reliability of the inverter. Moreover, the grid-connected inverter considering the four-quadrant rated operation designed stack and verified the feasibility of the design through a thermal analysis.

  • PDF

MATLAB/SIMULINK를 이용한 전동기 가변속 구동시스템 모델링 및 시뮬레이션 (Modeling and Simulation with a Variable Speed Drive System of a Electric Motor Using MATLAB/SIMULINK)

  • 정삼용;최연옥;한엄용;오금곤;정수복;조금배
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.141-147
    • /
    • 1997
  • The variable speed drive system of a electric motor is popular in industry due to its economical aspect and simplicity of implementation, comparing with a steam turbine or the other engine driven. For a large pumping load like a feedwater pump rated about or more than 20,000㎾, a synchronous motor could be primarily considered. In this paper, we studied the modelling of a variable speed drive system consisted with a load commutated inverter(LCI) and a brushless sailent pole rotor synchronous motor(SM) using MATLAB/SIMULINK. Simulation was performed with a small SM motor parameters.

  • PDF

고정밀 전기식 힘측정기의 불확도평가 절차 및 응용 (Procedure for Uncertainty Evaluation of a Precision Electric Force Measuring Device and Its Application)

  • 김갑순;강대임
    • 한국정밀공학회지
    • /
    • 제16권12호
    • /
    • pp.161-167
    • /
    • 1999
  • This paper describes the calibration method and the calculation equations of expanded uncertainty for a precision electric force measuring device. The calibration of the electric force measuring device is performed three times (0 ${\circ}$(first time), $120{\circ}$(second time), $240{\circ}$(third time)) at each calibration point. It is usually selected ten points from zero load to rated load of the electric force measuring device. The expanded uncertainty is calculated by combining A type standard uncertainty and B type standard uncertainty. The calibration method and the calculation equations of expanded uncertainty can be widely used in the calibration of the precision electric force measuring device.

  • PDF

정 전압 출력을 갖는 벅-부스트 컨버터의 제어기 설계 (Controller Design of Buck-Boost Converter with Constant Voltage Output)

  • 이우철
    • 조명전기설비학회논문지
    • /
    • 제29권9호
    • /
    • pp.42-50
    • /
    • 2015
  • The Buck-Boost converter consisted of two switches is more expensive than the conventional Buck converter, because of the increase of the components. However, it can control the DC voltage depending on the requested load voltage without additional circuits, because it can control the voltage under the relatively wide range of the load. Additionally, it can control the output voltage constantly under the variation of the input voltage. In the paper two control loops consisted of current and voltage control are designed. When two controllers are operated at the same time the problem of the output voltage is occurred. Therefore, the solution of the output voltage problem is proposed. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype system rated at 1kVA.

I/F 초기 기동 방법을 적용한 드럼세탁기용 IPMSM의 벡터제어 (IPMSM Vector Control using an I/F Initial Operating Method for Drum Washing Machine)

  • 박진호;이정효;김경민;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2009년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.271-273
    • /
    • 2009
  • Because few signals are generated using low resolution position sensor at low speed, rotor position estimation is difficult in drum washing machine application. Besides, inertia of water and drum affect the initial operation load up to two times of rated load. Therefore overcurrent can be occurred at initial operation. In this paper, IPMSM vector control for drum washing machine is proposed by applying I/F initial operating method and sensorless control. And we verify the performance through experiment.

  • PDF

내연기관 구동 비상용 브러시리스형 동기발전기의 과도특성 개선 (Improvement of Transient Characteristics of Brush-less Type Synchronous Generator for Emergency Driven by Internal-Combustion Engine)

  • 안영주
    • 전기학회논문지P
    • /
    • 제65권4호
    • /
    • pp.268-272
    • /
    • 2016
  • A brush-less type synchronous generator is driven by an internal-combustion engine that is used for emergency source. This kind of generator has to maintain output voltage in a range of some degree under the abrupt load irregular conditions such as a full load trip. This paper suggests a suppression method of increasing the output voltage over the rating. Automatic voltage regulator detects excessive rising of output voltage of the generator and supplies the signals to a switch installed in the rotating exciter through the photo-coupler. The current of main field rapidly decreases by additional resistor of the main filed circuit. Therefore, the output voltage of the generator is maintained effectively. The experimental results verified that the excessive value of the output voltage is limited in the range of 7% of the rated voltage.

정적인 자세에서 목의 주관적 작업부하 평가 (A Study on Subjective Evaluation of Neck Workload in Static Work)

  • 김유창;정현욱
    • 산업공학
    • /
    • 제16권2호
    • /
    • pp.222-228
    • /
    • 2003
  • Computer-dominated jobs and industrial automation have rapidly created work-related musculoskeletal disorders(WMSDs) and WMSDs are also founded in employees of other general industries. WMSDs has been growing problems for Korean industries with higher incidence rate every year. The objective of this paper is to analyze the effects of the neck muscle workload according to postures(joint angle) and load weights. Seven male students participated in this study. Neck workload was rated on each person using a Borg's CR-10 scale. ANOVA showed that the CR-10 ratings were statistically significant according to postures and load weights. To reduce the large number and severity of WMSDs, which employees have been experiencing, we need to redesign the job in workplace so that we can control hazards that are reasonably likely to be causing or contributing to the WMSDs. The results of this study can be used to establish the safety criteria of joint angle and weight of neck workload.

최상부 유온을 이용한 배전용 변압기의 진단 기법 (A Diagnostic Technique for Distribution Transformers using Top Oil Temperature)

  • 최도혁;윤용한;민경래;김재철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권5호
    • /
    • pp.242-251
    • /
    • 2000
  • In this paper, we argued the possibility of the diagnostic technique for distribution transformers using the top oil temperature rising above the ambient temperature. The proposed diagnostic technique used the reference top oil temperature rising at rated current. We determined the emergency value of the transformer using the limitation of the top oil temperature rising and calculated the loss of life. The top oil temperature rises because of the load currents. In this point, the proposed diagnostic technique was explained. The proposed system measures the load current, top oil temperature and ambient temperature. With the diagnostic device, we tested the top oil temperature rising of t재 transformers. Then the loss of life was calculated by the top oil temperature.

  • PDF

Brushless DC motor의 설계 Parameter 분석 기법에 관한 연구 (A study on Analysis Technique of Design Parameters for Brushless DC motor)

  • 맹경호;박창순
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.6-8
    • /
    • 2004
  • Recently, it is increasing to use more Brushless DC Motor with high energy density permanent magnet and semiconductor control unit for complementing the mechanical defect of Brushed DC Motors. For designing of BLDC Motors are required complex parameters like as rated characteristic, Geometries, B-H curve of magnet and steel materials, winding factor, etc. Moreover, design and manufacturing are difficult because of additional control circuits. Generally, Design parameters are gotten by analysis of Motor which is used. And the design parameters are used to design a new motor. But getting the design parameters through the eyes and experience is limited and it takes a long time. In this paper a method is proposed to efficiently analyze motor design parameters through the No load and Load Test, Back EMF Test, Simulation Analysis and Patent Analysis Method for existing BLDC Motor for a cooling Fan in Vehicle.

  • PDF