• Title/Summary/Keyword: Rate of volume change

Search Result 614, Processing Time 0.034 seconds

Comparison of Survival of SureDerm®, Permacol® Graft in Mouse (마우스에서 SureDerm®, Permacol® 이식 생존에 대한 비교)

  • Hong, Jung Soo;Kim, Woo Seob;Yu, Young Il;Kim, Han Koo
    • Archives of Plastic Surgery
    • /
    • v.34 no.6
    • /
    • pp.685-690
    • /
    • 2007
  • Purpose: Numerous materials, both autologous and nonautologous, have been used for augmentation of sunken areas and each has its own limitations. The ideal material for augmentation should not be absorbed in any manner. This study is designed to assess the survival of $SureDerm^{(R)}$, $Permacol^{(R)}$ graft according to the volume and histologic change. Methods: Twenty four mice, weighing about 50 grams and of 5 weeks of age were used. $SureDerm^{(R)}$ is an acellular dermal matix obtained from human cadeveric skin. $Permacol^{(R)}$ is a porcine derived acellular dermal matrix whose manufacture involves trypsinisation, solvent extraction. Graft pieces standardized to $1{\times}1cm$ size were used in each group. The implanted material were taken 1, 4, 8 and 12 weeks later, respectively. The changes of graft volume during the graft period were measured on initial, 1, 4, 8 and 12 weeks. Results: The initial shape of graft was maintained up to 12 weeks in $Permacol^{(R)}$ graft group and mean survival rate was $80.36{\pm}8.21%$ in $SureDerm^{(R)}$, $89.57{\pm}6.39%$ in $Permacol^{(R)}$(p=0.01). The volume of each graft decreased 29% from initial volume on 12 weeks in $SureDerm^{(R)}$, 18% in $Permacol^{(R)}$. The structure of $Permacol^{(R)}$ remained until 12 week after implantation. Conclusion: Our experimental study suggests that $Permacol^{(R)}$ could be a safe material as an implant for permanent augmentation. However, There are further study remained for antigenicity of these material, and the choice of graft for augmentation should be remained to the clinical situations.

The assessment analysis of rail transit operation in Seoul metropolitan area (도시권 지하철.전철의 운행평가 분석)

  • Lim, Kang-Won
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.1 no.1
    • /
    • pp.111-125
    • /
    • 1976
  • This study investigates the one-year performance of the Seoul Metropolitan Rail Transit(SMRT) operation. It intends to provide a basic understanding for railway operation in Seoul Metropolitan Area and thereby for making rational transport policy. The paper is conceptually comprised of four sections; analysis of passenger travel characteristics; SMRT costing and traffic cost function: its operating characteristics in terms of finance and utilization; primary social benefits of SMRT and suggestions. In the first year of operation (1974), the average daily traffic was about 335,000, After the drastic increases of fare in both Subway and KNR rail-lines, the travel volume has been cut by almost 10 percent, though most pronounced on intra-Subway line. The spatial distribution of passengers indicates that travelers use the SMRT line mainly for uninterrupted direct travel toward the CBD. In the prospective costing, the opereting expenses are divided into three groups; those which vary directly with volume; those partially variable with volume; and those entirely unrelated to volume change, With this information, cost function was derived for varying schedules of operation. Primary social benefits of the SMRT are assessed, though preliminary. Account should be taken of the nature of common costs of the SMRT in fare-rate making, especially when much of the operating expenses are accounted for by the fixed costs such that the revenue may not readily turn into break-even. The accounting results of the one-year operation coincide reasonably well with the prospective costing estimates. According to the findings of this annd another travelers' behavior studies, managerial effort would bring more revenue gain to the SMRT than fare increase does, not to speak of greater social benefits by so doing.

  • PDF

Experimental Study on Compressibility Modulus of Pressure Compensation Oil for Underwater Vehicle (심해 장비용 압력보상유의 압축성 계수 측정을 위한 실험적 연구)

  • Kim, Jin-Ho;Yoon, Suk-Min;Hong, Sup;Min, Cheon-Hong;Sung, Ki-Young;Yeu, Tae-Kyeong;Choi, Hyuek-Jin;Lee, Seung-Guk
    • Ocean and Polar Research
    • /
    • v.37 no.1
    • /
    • pp.73-80
    • /
    • 2015
  • In order to determine the appropriate volume of the a pressure compensator of deep seabed mining robots, this paper reports on an experimental test for oil volume change in an oil-filled box. At the design stage of underwater robots, it is crucial to determine the capacity of the hydraulic compensator which is replenished as much as the contracted oil volume of the robots. A pilot mining robot, MienRo was designed to work under 6,000 m in the deep sea. The hydraulic actuating oil and pressure compensating oil of MineRo may be exposed at a hydrostatic pressure environment of 600 bar. Although the oil can be assumed to be incompressible, its volume is actually changed under high pressure conditions due to air contained in the oil and oil contraction. To determine the capacity of the pressure compensator, the oil contraction rate should be verified through an experimental test using a hyperbaric chamber.

Atomic layer deposition of In-Sb-Te Thin Films for PRAM Application

  • Lee, Eui-Bok;Ju, Byeong-Kwon;Kim, Yong-Tae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.132-132
    • /
    • 2011
  • For the programming volume of PRAM, Ge2Sb2Te5(GST) thin films have been dominantly used and prepared by physical vapor deposition (PVD), chemical vapor deposition (CVD), atomic layer deposition (ALD). Among these methods, ALD is particularly considered as the most promising technique for the integration of PRAM because the ALD offers a superior conformality to PVD and CVD methods and a digital thickness control precisely to the atomic level since the film is deposited one atomic layer at a time. Meanwhile, although the IST has been already known as an optical data storage material, recently, it is known that the IST benefits multistate switching behavior, meaning that the IST-PRAM can be used for mutli-level coding, which is quite different and unique performance compared with the GST-PRAM. Therefore, it is necessary to investigate a possibility of the IST materials for the application of PRAM. So far there are many attempts to deposit the IST with MOCVD and PVD. However, it has not been reported that the IST can be deposited with the ALD method since the ALD reaction mechanism of metal organic precursors and the deposition parameters related with the ALD window are rarely known. Therefore, the main aim of this work is to demonstrate the ALD process for IST films with various precursors and the conformal filling of a nano size programming volume structure with the ALD?IST film for the integration. InSbTe (IST) thin films were deposited by ALD method with different precursors and deposition parameters and demonstrated conformal filling of the nano size programmable volume of cell structure for the integration of phase change random access memory (PRAM). The deposition rate and incubation time are 1.98 A/cycle and 25 cycle, respectively. The complete filling of nano size volume will be useful to fabricate the bottom contact type PRAM.

  • PDF

Thermo-fluid Dynamic and Missile-motion Performance Analysis of Gas-Steam Launch System Utilizing Multiphase Flow Model and Dynamic Grid System (다상 유동모델과 동적 격자계를 활용한 가스-스팀 발사체계의 열유동과 탄의 운동성능 해석)

  • Kim, Hyun Muk;Bae, Seong Hun;Park, Cheol Hyeon;Jeon, Hyeok Soo;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.2
    • /
    • pp.48-59
    • /
    • 2017
  • In this study, an analysis of the thermo-fluid dynamic and missile-motion performance was carried out through a numerical simulation inside the missile canister. Calculation was made in an analytical volume using dynamic grid and evaporated water was used as a coolant. To analyze the interaction among the hot gas, coolant, and mixture flow, Realizable $k-{\varepsilon}$ turbulence and VOF (Volume Of Fluid) model were chosen and a parametric study was performed with the change of coolant flow rate. As a result of the analysis, pressure of the canister showed a large difference depending on the presence or absence of the coolant, and also showed a dependancy on the amount of coolant. Velocity and acceleration were dependent on the canister pressure.

Comparison of Maximum Phonation Time Associated with the Changes in Vocal Intensity in Patients with Unilateral Vocal Fold Palsy and Sulcus Vocalis (성대마비와 성대구증의 강도 변화에 따른 최대발성지속시간 비교)

  • Choi, Se-Jin;Choi, Hong-Shik;Kim, Jae-Ock;Choi, Yae-Lin
    • Phonetics and Speech Sciences
    • /
    • v.4 no.1
    • /
    • pp.125-131
    • /
    • 2012
  • The patients with incomplete glottic closure have an important feature decreasing the maximum phonation time (MPT) because airflow rate or air leakage is greater than people without voice disorders. Also they can appear a problem in the intensity regulation. This study analyzed MPT difference based on the comfortable intensity and louder intensity and the correlation between MPT and respiration volume of unilateral vocal fold palsy (UVFP) and sulcus vocalis (SV) group. The twenty with UVFP, the 21 with SV, the 21 normal subjects measured MPT in /a/ vowel prolongation task with comfortable intensity and louder intensity and compared analysis by measuring FVC, $FEV_1$, $FEV_1/FVC$ to analyze the correlation between MPT and respiration volume. First, a comparison of MPT according to the intensity between groups is that MPT of the normal group was statistically significant long compared to the patient group in comfortable intensity, but MPT between groups was not statistically significant difference in the louder intensity. Second, an analysis of the correlation between MPT and respiration volume is that this was statistically significant correlation between MPT in comfortable intensity and MPT in louder intensity. But this did not show statistically significant correlation between intensity and respiration volume. This study can be supported the preceding study results deduced that shorting MPT of the patient group compared to the normal group was originated in the problem of laryngeal valving mechanism at the level of vocal folds rather than a problem of respiratory function. Also at the phonation by varying the intensity, the result can deduce that in the case of patient group, the length of MPT had been improved by increasing the glottal closure ratio in the louder intensity. These results can support the theoretical basis that should be applied to the clinicians by varying the intensity at the voice evaluation and voice therapy for the patients with the glottis incompetence.

Evaluation of Roadmap Image Quality by Parameter Change in Angiography (혈관조영검사에서 매개변수 변화에 따른 Roadmap 영상의 화질평가)

  • Kong, Chang gi;Song, Jong Nam;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2020
  • The purpose of this study is to identify factors affecting picture quality in Roadmap images, which were studied by varying the dilution rate, collimation field and flow rate of contrast medium. For a quantitative evaluation of the quality of the picture, a 3mm vessel model Water Phantom was self-produced using acrylic, a roadmap image was acquired with a self-produced vascular model Water Phantom, and the SNR(Signal to Noise Ratio) and CNR (Contrast to Noise Ratio) were analyzed. CM:N/S In the study on the change of dilution rate, CM:N/S dilution rate changed to (100%~10%:100%), and the measurement of the roadmap image taken using the vascular model Water Phantom showed that the measurement value of SNR gradually decreased as the N/S dilution rate was increased, and the measurement of CNR was gradually reduced. It was confirmed that the higher the dilution rate of CM:N/S, the lower the SNR and CNR, and also significant image can be obtained at the dilution rate of CM:N/S (100%~70:30%). The study showed the value of SNR and CNR in Roadmap image was increased as the Collimation Field was narrowed to the center of the vascular phantom; the Collimation Field was narrowed to the center of the vessel model by 2cm intervals to 0cm through 12cm. To verify the relationship with Roadmap image and Flow Rate, volume of the autoinjector was kept constant at 15 and the flow rate was gradually increased 1, 2, 3, 4, 5, 6, 7, 8, 9, 10. The value of SNR and CNR of images taken by using water Phantom gradually decreased as the Flow Rate increased, but at Flow Rate 9 and 10, the SNR and CNR value was increase. It was not possible to confirm the relationship with SNR and CNR by ROI mean value and Background mean value. It is considered that further study is needed to evaluate the correlation about Roadmap image and Flow Rate. In conclusion, as the dilution rate of N/S in contrast medium was increased, the value of SNR and CNR was decreased. The narrower the Collimation Field, the higher image quality by increasing value of SNR and CNR. However, it is not confirmed the relationship Roadmap image and Flow Rate. It is considered that appropriate contrast medium concentration to minimize the effects of kidney and proper Collimation Field to improve contrast of image and reduce exposure X-ray during procedure is needed.

Contrast Media in Abdominal Computed Tomography: Optimization of Delivery Methods

  • Joon Koo Han;Byung Ihn Choi;Ah Young Kim;Soo Jung Kim
    • Korean Journal of Radiology
    • /
    • v.2 no.1
    • /
    • pp.28-36
    • /
    • 2001
  • Objective: To provide a systematic overview of the effects of various parameters on contrast enhancement within the same population, an animal experiment as well as a computer-aided simulation study was performed. Materials and Methods: In an animal experiment, single-level dynamic CT through the liver was performed at 5-second intervals just after the injection of contrast medium for 3 minutes. Combinations of three different amounts (1, 2, 3 mL/kg), concentrations (150, 200, 300 mgI/mL), and injection rates (0.5, 1, 2 mL/sec) were used. The CT number of the aorta (A), portal vein (P) and liver (L) was measured in each image, and time-attenuation curves for A, P and L were thus obtained. The degree of maximum enhancement (Imax) and time to reach peak enhancement (Tmax) of A, P and L were determined, and times to equilibrium (Teq) were analyzed. In the computed-aided simulation model, a program based on the amount, flow, and diffusion coefficient of body fluid in various compartments of the human body was designed. The input variables were the concentrations, volumes and injection rates of the contrast media used. The program generated the time-attenuation curves of A, P and L, as well as liver-to-hepatocellular carcinoma (HCC) contrast curves. On each curve, we calculated and plotted the optimal temporal window (time period above the lower threshold, which in this experiment was 10 Hounsfield units), the total area under the curve above the lower threshold, and the area within the optimal range. Results: A. Animal Experiment: At a given concentration and injection rate, an increased volume of contrast medium led to increases in Imax A, P and L. In addition, Tmax A, P, L and Teq were prolonged in parallel with increases in injection time The time-attenuation curve shifted upward and to the right. For a given volume and injection rate, an increased concentration of contrast medium increased the degree of aortic, portal and hepatic enhancement, though Tmax A, P and L remained the same. The time-attenuation curve shifted upward. For a given volume and concentration of contrast medium, changes in the injection rate had a prominent effect on aortic enhancement, and that of the portal vein and hepatic parenchyma also showed some increase, though the effect was less prominent. A increased in the rate of contrast injection led to shifting of the time enhancement curve to the left and upward. B. Computer Simulation: At a faster injection rate, there was minimal change in the degree of hepatic attenuation, though the duration of the optimal temporal window decreased. The area between 10 and 30 HU was greatest when contrast media was delivered at a rate of 2 3 mL/sec. Although the total area under the curve increased in proportion to the injection rate, most of this increase was above the upper threshould and thus the temporal window was narrow and the optimal area decreased. Conclusion: Increases in volume, concentration and injection rate all resulted in improved arterial enhancement. If cost was disregarded, increasing the injection volume was the most reliable way of obtaining good quality enhancement. The optimal way of delivering a given amount of contrast medium can be calculated using a computer-based mathematical model.

  • PDF

Renal Effects of Chronic Treatment Of Adenosine Analogues (Adenosine 수용체 작동제 장기 투여의 신장효과)

  • Kim Tack-Hee;Kim Suhn-Hee;Huh Jong;Cho Kyung-Woo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.1 no.3
    • /
    • pp.325-335
    • /
    • 1997
  • Evidence for the existance of at least two subclasses of renal adenosine receptors has been presented. N-6-cyclohexyladenosine (CHA) is a relatively selective $A_1$ adenosine agonists, whereas 5'-N-ethylcarboxamidoadenosine (NECA) acts as a preferential agonist of $A_2$ adenoisne receptor. N6-(L-2-phenylisoproryl)-adenosine (PIA) almost unselectively activates both $A_1\;and\;A_2$ adenosine receptors at micromolar concentrations. During the characterization of adenosine receptor in the kidney, we have discovered a novel phenomenon, that is, an intramuscular administration of CHA for 3 days caused a diuresis and a suppression of urinary concentrating ability. To further characterize this novel phenomenon, an intramuscular administration of adenosine and other adenosine angonists, PIA and NECA, and prior treatment of adenosine antagonists, caffeine, theophylline and 1,3-diethyl-8-phenyl-xanthine (DPX) were performed. Systemic administration of CHA, PIA, and NECA for 3 days caused a suppression in heart rate, blood pressure and general motor activity without change in rectal temperature. Systemic administration of CHA, 0.5, 1 and 2 mg/kg/day, for 3 days caused a dose-dependent increase in urine volume and decrease in urinary osmolarity and free water reabsorption. This phenomenon was reversible and repeatable. Administration of adenosine (40 mg/kg/day) produced no apparent effect on the renal function, whereas PIA (2 mg/kg/day) produced an similar effect to CHA on the renal function. Systemic adminstration of NECA, 0.025, 0.05 and 0.25 mg/kg/day, for 3 days caused a dose-dependent increase in urine volume and dose-dependent increases in excreted amount of creatinine, urinary osmolarity and free water reabsorption. These renal effects of adenosine agonist were maximum at second day during the drug administration. In terms of increase in urine volume and the suppression of urinary concentrating ability, NECA was potent than CHA. Prior treatment of caffeine (50 mg/kg/day) or theophylline (50 mg/kg/day) abolished the diuretic effect of CHA, whereas DPX (50 mg/kg/day) did not affect the CHA effect. CHA, 0.5 mg/kg/day, produced no change in plasma renin activity and plasma levels of aldosterone, epinephrine, and norepinephrine. These results suggest that this novel phenomenon produced by an activation of renal adenosine receptors plays an important role in urinary concentrating mechanism.

  • PDF

The Effects of Inspiratory Pause on Airway Pressure and Gas Exchange under Same I:E ratio in Volume-controlled Ventilation (Volume-Controlled Mode의 기계환기시 동일환 I:E Ratio하에서 Inspiratory Pause가 기도압 몇 가스교환에 미치는 영향)

  • Choi, Won-Jun;Jung, Sung-Han;Lee, Jeong-A;Choe, Kang-Hyeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.1022-1030
    • /
    • 1998
  • Background : In volume-controlled ventilation, the use of inspiratory pause increases the inspiratory time and thus increases mean airway pressure and improves ventilation. But under the same I : E ratio, the effects of inspiratory pause on mean airway pressure and gas exchange are not certain. Moreover, the effects may be different according to the resistance of respiratory system. So we studied the effects of inspiratory pause on airway pressure and gas exchange under the same I : E ratio in volume-controlled ventilation. Methods: Airway pressure and arterial blood gases were evaluated in 12 patients under volume-controlled mechanical ventilation with and without inspiratory pause time 5%. The I : E ratio of 1 : 3, $FiO_2$, tidal volume, respiratory rate, and PEEP were kept constant. Results: $PaCO_2$ with inspiratory pause was lower than without inspiratory pause ($38.6{\pm}7.4$ mmHg vs. $41.0{\pm}7.7$ mmHg. p<0.01). P(A-a)$O_2$ was not different between ventilation with and without inspiratory pause $185.3{\pm}86.5$ mmHg vs. $184.9{\pm}84.9$ mmHg, p=0.766). Mean airway pressure with inspiratory pause was higher than without inspiratory pause ($9.7{\pm}4.0\;cmH_2O$ vs. $8.8{\pm}4.0\;cmH_2O$, p<0.01). The resistance of respiratory system inversely correlated with the pressure difference between plateau pressure with pause and peak inspiratory pressure without pause (r=-0.777, p<0.l), but positively correlated with the pressure difference between peak inspiratory pressure with pause and peak inspiratory pressure without pause (r=0.811, p<0.01). Thus the amount of increase in mean airway pressure with pause positively correlated with the resistance of respiratory system (r=0.681, p<0.05). However, the change of mean airway pressure did not correlated with the change of $PaCO_2$. Conclusion: In volume-controlled ventilation under the same I : E ratio of 1 : 3, inspiratory pause time of 5% increases mean airway pressure and improves ventilation. Although the higher resistance of respiratory system, the more increased mean airway pressure, the increase in mean airway pressure did not correlated with the change in $PaCO_2$.

  • PDF