• 제목/요약/키워드: Rate of change of frequency

검색결과 551건 처리시간 0.03초

Inertial Control of a DFIG-based Wind Power Plant using the Maximum Rate of Change of Frequency and the Frequency Deviation

  • Lee, Hyewon;Kim, Jinho;Hur, Don;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.496-503
    • /
    • 2015
  • In order to let a wind generator (WG) support the frequency control of a power system, a conventional inertial control algorithm using the rate of change of frequency (ROCOF) and frequency deviation loops was suggested. The ROCOF loop is prevailing at the initial stage of the disturbance, but the contribution becomes smaller as time goes on. Moreover, its contribution becomes negative after the frequency rebound. This paper proposes an inertial control algorithm of a wind power plant (WPP) using the maximum ROCOF and frequency deviation loops. The proposed algorithm replaces the ROCOF loop in the conventional inertial control algorithm with the maximum ROCOF loop to retain the maximum value of the ROCOF and eliminate the negative effect after the frequency rebound. The algorithm releases more kinetic energy both before and after the frequency rebound and increases the frequency nadir more than the conventional ROCOF and frequency loops. The performance of the algorithm was investigated under various wind conditions in a model system, which includes a doubly-fed induction generator-based WPP using an EMTP-RV simulator. The results indicate that the algorithm can improve the frequency drop for a disturbance by releasing more kinetic energy.

주파수 변화율을 이용한 동적부하차단 방안 (A Scheme on the Dynamic Load Shedding Using Rate of Frequency Decline)

  • 이소영;장병태;이재욱;오화진;조범섭;김재현
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권6호
    • /
    • pp.301-306
    • /
    • 2003
  • When a bulk power system experiences a serious disturbance or heavy load trip, the system frequency may drop and even collapse if the total generating power does not supply the system demand sufficiently. Since an isolated power system possesses a lower inertia and comes with limited reserves, the load shedding by under frequency relay becomes an important strategy to keep system natural frequency. This paper presents a scheme to determine the load shedding criteria by using the rate of change of frequency when the large disturbance happens.

자율신경활성도의 지표로서의 동공크기 변이율 -자세변화, 졸음, 인지과제 실험으로부터 (Pupil Size Variability as an Index of Autonomic Activity - from the Experiments of Posture, Sleepiness and Cognitive Task)

  • 이정찬;김지은;박경모
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.55-65
    • /
    • 2007
  • This paper sought to investigate pupil size variability, pupil size parameters in terms of time domain and frequency domain, the autonomic activity change induced by posture change, degree of sleepiness and cognitive task (math task). With a specially designed pupil image acquisition system in the dark room, these three kinds of experiments were performed to induce a dominant state of sympathetic or parasympathetic activation. Electrocardiogram and pupil size were measured in all the experiments. Based on three experiments, we calculated heart rate variability. In the pupil size analysis, we calculated the mean and standard deviation of pupil size (in time domain), and proposed several frequency bands that exhibit different autonomic activation between different sessions. The results indicate that in terms of heart rate variability, posture change exhibited significant differences but not between sleepiness level, or between cognitive task. Pupil sizes differed only during the postures. And we found some frequency bands that correlated with autonomic activation in each experiment. While heart rate variability reflects posture change that need cardiac control, pupil size variability reflects not only posture induced autonomic activation but sleepiness and cognitive load, which is processed in the brain, in time and frequency domain parameter.

발화 속도와 말차례 교체 빈도에 따른 운율 단위 변화에 관한 연구 (A study on the change of prosodic units by speech rate and frequency of turn-taking)

  • 원유권
    • 말소리와 음성과학
    • /
    • 제14권2호
    • /
    • pp.29-38
    • /
    • 2022
  • 이 연구는 국립국어원 일상 대화 음성 코퍼스(2020)에서 나타나는 발화를 분석하여 발화 속도 및 말차례 교체 빈도가 운율 단위 변화에 어떤 영향을 끼치는지 밝히는 것을 목적으로 하였다. 분석 결과, 발화 속도가 증가할수록 억양구, 어절 빈도, 발화 길이가 증가하는 양의 상관관계를 보였으나 상관관계가 낮았고, 회귀모형의 적합도는 3%-11%로 설명력이 약했다. 말차례 교체 빈도에 따른 평균 발화 속도는 유의미한 차이가 있었고, 말차례 교체 빈도가 증가할수록 발화 속도는 감소하였다. 또한 말차례 교체 빈도가 증가할수록 억양구 및 어절 빈도와 발화 길이는 감소하였으며 높은 음의 상관관계가 있는 것으로 나타났다. 회귀 모형의 적합도는 27%-32%로 계산되었다. 말차례 교체 빈도가 발화 속도와 운율 단위를 변화시키는 요인으로 작용했을 수 있다. 이는 대화체에서 나타나는 비유창성, 말차례 교체 특성, 화자 간 활발한 상호작용 등이 영향을 미쳤을 것이라 추측된다.

각진형과 아치형 눈썹메이크업의 평균변화율 및 곡률에 따른 형태구성의 중요요인 분석 (Analysis Of The Average Rate Of Change And Curvature According To The Type Of Angled And Arched Eyebrow Makeup)

  • 박정신;박동은
    • 패션비즈니스
    • /
    • 제23권1호
    • /
    • pp.116-126
    • /
    • 2019
  • The purpose of this study is to objectify the shape of curvature and average change rate of angular and arched eyebrow makeup. The data for the analysis were the final 336 pieces for the cosmetology students in the whole country. SPSS 20.0 program was used for the collected data, frequency analysis, factor analysis, reliability analysis, and crossover analysis were performed. First, the frequency of the average change rate of eyebrow makeup (angular and arcuate) was analyzed. As a result, the eyebrows suitable for the angled type showed the highest level of 'A-2' and the arched eyebrows had the highest level of 'B-2'. Second, to analyze the important factors of eyebrow makeup, frequency of eyebrows was the most important, followed by the inclination of eyebrows and eyebrow tail. Third, factor analysis and reliability analysis were conducted to examine each dimension of eyebrow makeup perception, and it was derived from three factors including acceptability, aggressiveness, and playability. Fourth, in order to analyze the difference of important factors in the form of the standard eyebrow makeup, the cross - analysis was performed with chi - square test, and it was confirmed that the angular eyebrow makeup showed the most objectivity when the average change rate was 0.29 and the curvature was 0.67. Fifth, arcuate eyebrow makeup showed the most objectivity when the average change rate was 0.57 and curvature was 0.56. The results of this analysis can be used as objective data of aesthetic criteria when designing the eyebrow shape.

주파수변화율을 이용한 제주계통 부하차단 방안 (A Scheme for the Load Shedding on Cheju Power Systems using Rate of Change of Frequency)

  • 장병태;이소영;조경보;곽노홍;안정식;오화진;조범섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.184-186
    • /
    • 2003
  • Power systems must be operated within limits that will ensure adequate generation and transmission capacity to avoid cascading. In developing a set of operations limits, it is important to do so within a general framework in order to ensure that the operating objectives are met. In the this regard, when the system experiences a generation-load imbalance, the principles of sound operation will be maintained by bringing under control an unscheduled power flow condition as quickly as possible. This paper presents load shedding application which responds both to frequency and to rate of change of frequency. Its application is in the operating situation of load suddenly in excess of generation, either because of generator or other equipment failure. A scheme which is able to utilize rate of change of frequency as well as frequency itself is an improvement over existing scheme.

  • PDF

점성토의 진동삼축시험시 대변형률영역에서의 주파수 의존성 (Frequency Dependence in Large Strain Range During Cyclic Triaxial Tests of Clay)

  • 김용성
    • 한국농공학회논문집
    • /
    • 제48권5호
    • /
    • pp.63-71
    • /
    • 2006
  • In the present study, the dynamic deformation characteristics of clay, including the effect of loading rate in large strain ranges, were examined by performing undrained cyclic triaxial test. The test results showed that the loading rate to failure decreased with increasing loading amplitude and decreasing loading frequency. While the stress-strain relationships was not affected by loading frequency, excess pore pressure was affected significantly with the change in loading frequency. The change for 0.1 Hz was larger for than that of 0.01 Hz, resulting in inclined effective stress paths. Furthermore, the lower the frequency was, the higher the excess pore pressure was in the first loading.

반복세탁 및 전단·인정변형에 따른 텐셀직물의 피로도 (Fatigue Phenomenon of Mechanical Properties in Tencel Fabrics by Repeated Washing & Shear and Tensile Deformation)

  • 권오경;이창미;김묘향;박희웅
    • 한국의류산업학회지
    • /
    • 제1권3호
    • /
    • pp.288-295
    • /
    • 1999
  • This study was conducted to examine the fatigue phenomenon of mechanical properties in tencel fabrics by repeated washing & shear and tensile deformation. The obtained results are as follows. After performing repeated shear tensile deformation, RT of tencel showed higher increase rate than that of cotton and rayon, whereas its WT and EM was a smaller decrease rate than that of them. This means that tencel's resistance to tensile deformation was the greatest. In the repeated washing and shear tensile deformation, tencel's 2HB, 2HG and 2HG5 showed a remarkable increase rate. In terms of deformation frequency, the greatest change rate appeared at the time of 1000 cycles of repeated shear tensile deformation and 15 times of repeated washing. In the hand value and THV, KOSHI showed a higher increase rate for tencel than for cotton and rayon in both repeated washing and shear tensile deformation, and NUMERI showed a higher increase rate. In the THV the change rate of rayon and cotton could be rarely seen but for tencel, it decreased. tencel's change rate of thermal insulation value by materials was 1.08%, and it increased as the washing frequency increased, compared to the grey fabrics, whereas the change rates of cotton and rayon were 0.74% and 0.22%, respectively. The qmax decreased in the order of cotton>tencel>rayon as the washing frequency increased.

  • PDF

자세변화가 자율신경계에 미치는 영향 (The Influence of Position Change on Autonomic Nervous System Function)

  • 김인배;김은경;강종호
    • 대한물리의학회지
    • /
    • 제9권1호
    • /
    • pp.63-68
    • /
    • 2014
  • PURPOSE: The purpose of this study was to examine the position changes with tilt table on autonomic nervous system using heart rate variability analysis. METHODS: Fourty healthy adult males volunteered in this study. The low frequency, high frequency and low frequency/high frequency ratio and mean heart rate, standard deviation of all normal R-R intervals, root mean square of successive differences, heart rate variability index were measured at the tilt table angle of $0^{\circ}$, $45^{\circ}$ and $90^{\circ}$ with pulsoximeter. Data were analyzed one-way ANOVA and LSD post hoc test. RESULTS: The mean heart rate, low frequency and low frequency/high frequency ratio increased significantly at higher angle of tilt table(p<.05). The root mean square of successive differences, heart rate variability index decreased significantly at lower angle of tilt table(p<.05). The standard deviation of all normal R-R intervals, high frequency decreased at higher angle of tilt table did not show significant difference. CONCLUSION: The symphathetic activity increased significantly at higher angle of tilt table. The parasymphathetic activity decreased at higher angle of tilt table, but the difference were not significant. The autonomic adaptation, balance and heart rate variability decreased significantly at higher angle of tilt table. Based on these results, in the treatment of patients with a change in posture precedence should be carefully treated. Further studies are necessary to determine the most safety and effective methods.

강우 확률년수의 설정이 우수관거 설계에 미치는 영향 (Effect of Rainfall Design Frequency Determination on the Design of Storm Sewer System)

  • 이철규;현인환;독고석;김형준
    • 상하수도학회지
    • /
    • 제19권5호
    • /
    • pp.647-654
    • /
    • 2005
  • Recently, the economic losses caused by inundation are increasing due to the urbanization and industrialization, i.e., intensive land utilization and concentration of population and properties. It is regarded that the role of the storm sewer systems in urban areas becomes more important as one of the effective countermeasures for reducing the inundation losses. In this study, the effects of rainfall design frequency enhancement on the construction cost of the storm sewer systems were analyzed by increasing the design frequency from the present design frequency of the sewer systems, which is 5~10 years, to 15 years, 20 years and 30 years. The change rate functions of the design discharge and construction cost based on the various design frequencies were derived by regression analysis. According to the analysis, change the rate of design discharge at 15, 20, 30 years rainfall design frequencies were increased by 10%, 17.1%, and 27.2%, respectively, when compared to that at 10 year frequency. Furthermore, it was found that by increasing the design frequency from 10 years to 15 years, 20 years and 30 years, the construction costs were increased by 5.0%, 8.0% and 12.4%, respectively. Finally, their reliabilities need to be tested by applying the rate functions to the real storm sewer districts.