A Fundamental Study on Method of Packaged Dry Combined Materials for Concrete - based on physical properties of concrete according to adding-water ratio - (건조된 콘크리트 재료의 포장화에 관한 기초적 연구 -가수율에 따른 콘크리트의 기초물성을 중심으로-)

  • 한다희;황병준;김제섭;박희곤;이영도;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.493-496
    • /
    • 2003
  • Most concrete is recently made of an aggregate which is properly absorbed, and carried in it in order to do capability at every fields. We have been close to demand new capability of high flowing and enduring for specific concretes. That is difficult to cope with claiming the efficiency on deterioration from lack of a high quality aggregate. Therefore, for solving the problems we apply to a packing method for using dried materials. That is to say it is a kind of making into an instant. In this study, There is a purpose to present fundamental data, comparing and analyzing a phenomenon about aggregate absorption following the rate of adding water, for using existing materials.

  • PDF

Experimental Study on Properties of Concrete Incorporating Inoragnic Antifouling Agent (무기계 방오(防汚)제가 혼입된 콘크리트 특성에 관한 실험적 연구)

  • Kim, Yeon-Bong;Nam, Jae-Hyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.2 s.16
    • /
    • pp.97-105
    • /
    • 2005
  • Concrete structures in the marine environment often deteriorate in the early stage of their service life because of contact with various aggressive conditions. In recent years, the researches on the concrete in the marine environment have been carried out to increase their service life. In this experimental study, the concrete specimens were prepared with various adding contents of inorganic antifouling agent$(0\~3.0wt\%)$ composed of some fluosilicate solution. For evaluation of the properties of concretes containing inorganic antifouling agent, various tests such as setting time, slump loss, compressive strength, water absorption rate, fleering and thawing resistance and SEM of concrete, were conducted. As the results, physical and chemical properties of concretes were improved with an adding of inorganic antifouling agent. From the results of various tests, the optimal adding contents of antifouling agent was $1.0wt\%$.

Experimental study on Properties of Concrete Using Inorganic Antifouling Agent (무기계 방오기능성 혼화제를 사용한 콘크리트 특성에 관한 실험적 연구)

  • Kim Yeon Bon;Kang Yong Sik;Lee Byoung Ky;Kim Do Su;Khil Bae Su;Nam Jae Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.604-607
    • /
    • 2004
  • Concrete structures in the marine environment often deteriorate in the early stage of their service life because of contact with various aggressive conditions. In recent years, the study on the concrete in the marine environment are carried out to increase their service life. In this experimental study, the concrete specimens were prepared with various adding contents of inorganic antifouling agent$(0\~3.0wt\%)$ composed to some fluosilicate solution. For evaluatin of the physical and chemical properties of concretes containing inorganic antifouling agent, various tests such as setting time, slump loss, compressive strength, water absorption rate, freezing and thawing resistance and SEM micrographs of concrete, were conducted. As the results, physical and chemical properties of concretes were improved with an adding of inorganic antifouling agent. From the results of various tests, the optimal adding contents of antifouling agent was $1.0wt\%$.

  • PDF

Study on Improvement of Cooking Rice Method for Acceleration of Consumption of the Rice (쌀소비 촉진을 위한 쌀밥 조리 개선 연구 (I) - 취반시 조리수에 산, 지방, Cellulose 첨가에 따른 texture 변화)

  • 김경자;양화영;오미향;구정선
    • Korean journal of food and cookery science
    • /
    • v.9 no.1
    • /
    • pp.25-29
    • /
    • 1993
  • This study was attempted to enhance taste and quality value of cooked rice by adding fat, vinegar, cellulose in cooking water. Cooked rice with five different levels of material in cooking water (100% water A: 10% vinegar B: 10% fat C: 10% fat and 10% vinegar D: 10% fat, 10% vinegar and 10% celloulose) was tested for rheology, fine structural changes, sensory evaluation, in vitro digestion. 1) Cooked rice by adding 10% fat rate was higher than A, B, D, E samples for softness, Jelly and increased in vitro digestion. 2) sensory evaluation conducted by tweenty university students a panelists showed that B, D sample were low value in flavour, texture and taste, but higher than A sample for softness, Jelly and in Vitro digestion. 3) E sample (l0% fat, 10%s vinegar, 10% cellulose) was more significant for taste, texture, and digestion than A sample. From these results, it was concluded that rice cooked with 10% of fat in cooking water was quite acceptable, in terms of practical food value consisting of palatability rheology and digestibility.

  • PDF

Removal of Procymidone by Ozonated Water (오존수를 이용한 프로시미돈의 제거)

  • Choi, Seong-Woo;Park, Shin-Young
    • Journal of Environmental Science International
    • /
    • v.16 no.12
    • /
    • pp.1425-1430
    • /
    • 2007
  • This study was conducted to investigate the effect of ozonated water and ozonated water+hydrogen peroxide treatment of residual procymidone in perilla leaf containing 20 mg/L procymidone. Samples was treated with ozonated water containing 1.0, 2.0 and 3.0 mg $O_3/L$ ozone and hydrogen peroxide water containing 1.0, 2.0 and 3.0 mg $H_2O_2/L$ hydrogen peroxide in pH 5, 7 and 9, respectively, at $15^{\circ}C$. Procymidone removal rate was 26.5% in 7 days at $15^{\circ}C$ and optimum condition of procymidone removal was the case of treating with ozonated water containing 2.0 mg $O_3/L$ and pH 9. As the result procymidone removal rate was about 96.5%. In this case of adding hydrogen peroxide, optimum condition of procymidone removal was $1:0.5{\sim}1(O_3:H_2O_2)$. However, procymidone was nearly removed with the treatment of hydrogen peroxide water only.

Effect of Grouting Materials on Ground Effective Thermal Conductivity (그라우팅 재료가 지중 유효열전도도에 미치는 영향)

  • Sohn, Byong-Hu
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3371-3376
    • /
    • 2007
  • The design of a ground-source heat pump system includes specifications for a ground loop heat exchanger where the heat transfer rate depends on the thermal conductivity of the ground. To evaluate this heat transfer property, in-situ thermal response tests on four vertical test boreholes with different grouting materials were conducted by adding a monitored amount of heat to water over various test lengths. By measuring the water temperatures entering and exiting the loop, water flow rate, and heat load, effective thermal conductivity values of the ground were determined. The effect of increasing thermal conductivity of grouting materials from 0.82 to 1.05 W/m$^{\circ}C$ resulted in overall increases in effective ground thermal conductivity by 25.8% to 69.5%.

  • PDF

Optimal Treatment of Molasses Wastewater Using UASB Process (UASB 공정에 의한 당밀폐수의 최적처리 방안)

  • Huh, Kwan-Yong;Jeong, Eui-Geun;Chung, Yoon-Jin;Yoo, Sang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.2
    • /
    • pp.112-127
    • /
    • 1997
  • The purpose of this study is to get optimum operating factors of Upflow Anaerobic Sludge Blanket (UASB) reactor by introducing methods that make it to reduce inhibition possible in each process wastewater treatment. The used substrates, concentrated corn starch liquid (CSL) wastewater, modified starch, filtering and decoloring wastewater, ion refining wastewater, and mixed wastewater including modified starch and not including modified starch, are generated from molasses process. The seeding sludge is the digested sludge that had been applied to molasses wastewater. Batch test to reduce the inhibition factors that might be existed in each wastewater was examined. Based on the this test, the optimum operating factors according to alkalinity and pH variation was studied through the continuous test using three 5.5 L UASB reactor. The first reactor added $NaHCO_3$ to control alkalinity. The hydraulic retention time (HRT) reduced to 8 hours and the organic loading rate increased gradually. The second reactor changed the pH of influent from 7.0 to 6.0 using NaOH. The third reactor was operated without changes to compare the above two reactors. As the result, the inhibition in concentrated CSL wastewater was removed by adding iron (II). When trace metals were added to mixed wastewater not including modified starch, the digestability by gas production rate increased to more fifty percentage than mixed wastewater that was not adding the trace metals. The reason that the inhibition did not decreased in spite of adding trace metals and nutrients was influenced by high concentration generated during the acid fermentation. The UASB reactors using the mixed wastewater with the most effective performance were operated as 500 mg/L as $CaCO_3$ alkalinity and 6.0 pH at steady state, and at this time, the gas production rates were 283 and 311mL gas/g $COD_{added}$. The COD removal rates were 84.7 and 86.3%, respectively.

  • PDF

Improvement of Organics and Nitrogen Removal by HRT and Recycling Rate in Air Lift Reactors (공기부상반응조에서 체류시간과 반송율에 의한 유기물질 및 질소제거 향상에 관한 연구)

  • Kim, Jin-Ki;Yu, Sung-Whan;Lim, Bong-Su
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.45-50
    • /
    • 2006
  • This study was performed to evaluate the air lift reactors (ALR) by variations of HRT and recycling rate. Air lift reactor was composed of bioreactor and clarifier above it. To remove organic matters and nitrogen through the formation of microbic film and filtration, bio-filter reactors were filled with clay, glass, bead, waste plastic, respectively. Influent wastewater was fed to biofilter reactor, and effluent wastewater from bio-filter reactor was injected ALR again, instead of adding external carbon source. Effluent BOD concentration was satisfied with lower than 10 mg/L in recycling rate 100% regardless of the variation of HRT and the kinds of media materials. In HRT 4 hr, recycling rate 100%, BOD removal efficiency rate was from about 85 to 90%, COD removal efficiency rate was higher than 90%. Effluent TN concentration was satisfied with less than 20 mg/L, if HRT was maintained by over than 6 hr regardless of recycling rate and media materials. Over than HRT was 4 hr, microbes concentration in air lift reactor was maintained over than 2,500 mg/L constantly, not sensitive to environmental condition, and organic removal was effective as it was higher.

EVALUATION OF PH CONTROL AGENTS INFLUENCING ON CORROSION OF CARBON STEEL IN SECONDARY WATER CHEMISTRY CONDITION OF PRESSURIZED WATER REACTOR

  • Rhee, In Hyoung;Jung, Hyunjun;Cho, Daechul
    • Nuclear Engineering and Technology
    • /
    • v.46 no.3
    • /
    • pp.431-438
    • /
    • 2014
  • The effect of various pH agents on the corrosion behavior of carbon steel was investigated under a simulated secondary water chemistry condition of a pressurized water reactor (PWR) in a laboratory, and the steel's corrosion performance was compared with the field data obtained from Uljin NPP unit 2 reactor. All tests were carried out at temperatures of $50^{\circ}C-250^{\circ}C$and pH of 8.5 - 10. The pH at a given temperature was controlled by adding different agents. Laboratory data indicate that the corrosion rate of carbon steel decreased as the pH increased under the test conditions and the highest corrosion rate was measured at $150^{\circ}C$. This high corrosion rate may be related to high dissolution and instability of Fe oxide ($Fe_3O_4$) at $150^{\circ}C$. It was also found that an addition of ethanolamine (ETA) to ammonia was more effectivefor anticorrosion than ammonia alone, and that mixed treatment reduced 50% of iron or more at pHs of 9.5 or higher, especially in the steam generator (SG) and the moisture separator & re-heater (MSR).

A study on the corrosion control of tap water by lime and carbon dioxide (소석회와 이산화탄소를 이용한 수돗물 부식성 제어에 관한 연구)

  • Cheong, Won-Suk;Kim, Jin-Keun;Park, Duk-Joon;Kim, Sun-Wook;Jeong, Sang-Gi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.193-199
    • /
    • 2011
  • A method to improve internal corrosion control efficiency by adding lime and carbon dioxide, which, in turn increases the Langelier Index (LI) for filtered water at a conventional drinking water treatment plant (WTP) was investigated. The SJ WTP (Q=100,000 $m^{3}$/d) has been operating an internal corrosion control system since 2006. The system has achieved stable operation through technical development and trial and error over a period of several years. As a result of the operation, the LI of treated water has increased up to 29% by adjusting pH of filtered water to 7.8 with the addition of lime and carbon dioxide. Coupon tests in the distribution system indicated that the corrosion rate has been delayed by 24% when the internal corrosion method was implemented. The increase of LI by lime and carbon dioxide has been proven to be a practical method for controlling corrosion.