• 제목/요약/키워드: Rate Test

검색결과 13,502건 처리시간 0.048초

단기간 생물농축계수의 측정에 있어서 실험어류의 종에 따른 차이 (Difference in Species of Test Fish on the Determination of Short-term Bioconcentration Factor)

  • 민경진;차춘근;전봉식;김근배
    • 한국환경보건학회지
    • /
    • 제24권1호
    • /
    • pp.24-31
    • /
    • 1998
  • This study was performed to investigate the difference in species of test fish on the determination of short-term bioconcentration factor in zebrafish(Brachydanio rerio), red sword tail(Xiphophorus hellieri) and goldfish(Carassius auratus). Experimental concentrations of carbamates were 0.05 and 0.10 ppm and chlorothalonil were 0.005 and 0.01 ppm for 3 and 5 days, respectively. This paper reports the measured BCF value on pesticides in various species of test fish, under steady state, and examined correlation between the BCF value and depuration rate constant or LC$_{50}$ or lipid content. Carbamates and chlorothalonil concentration in fish extract and BCF of carbamate and chlorothalonil were increased as incresing test concentration. Carbamates concentration in fish extract and BCF of carbamate were decreased as incresing test period, but chlorothalonil concentration in fish extract and BCF of chlorothalonil were increased as prolonging test period. Determined pesticide concentration in fish extract and BCF were highest in red sword tail, and followed by goldfish, and zebrafish. Determined depuration rate constant were highest in zebrafish, and followed by goldfish, and red sword tail. 96hr-LC$_{50}$ were highest in red sword tail, and followed by zebrafish, and goldfish. Lipid compositions were highest in red sword tail, and followed by goldfish, and zebrafish. Therefore, it is suggested that the difference of BCF between each pesticide due to those of lipid composition of fish and deputation rate constant, while LC$_{50}$ have no effect on BCF.

  • PDF

일정변형률 압밀시험에 따른 이암풍화토의 압밀특성 (A Consolidation Characteristics of Decomposed Mudstone Soil by Constant Rate of Strain Consolidation)

  • 김영수;김기영;김대만
    • 한국지반공학회논문집
    • /
    • 제16권1호
    • /
    • pp.99-106
    • /
    • 2000
  • 기존의 Oedometer 시험은 간단한 시험장치의 편리함으로 인해 널리 이용되어 왔다. 그러나 이 방법은 장시간의 시험기간, 각 단계 하중에서의 불규칙적인 응력상태, 매우 연약한 점토에 대한 시험의 어려움 및 시료의 포화문제와 같은 여러 문제점을 노출하게 되었다. 따라서 이런 단점을 보완 할 수 있는 시험 방법의 하나로 일정 변형률 압밀시험 이 개발되어 널리 이용되고 있다. 본 논문에서는 세가지 변형률을 이용한 CRS시험을 실시하였으며, 이 결과를 수정된 Wissa(1971)의 비선형 이론을 이용해 해석하고, 기존의 Oedometer시험 및 직접투수시험과 비교분석함으로서 CRS시험의 효율성 및 적용성 유무를 판단하고자 한다.

  • PDF

저변형률시험법에 의한 섬유강화 복합재료의 응력부식균열에 관한 연구 (A Study on Stress Corrosion Cracking of Fiber Reinforced Composite by Slow Strain Rate Test)

  • 임재규;최태수
    • 대한기계학회논문집A
    • /
    • 제20권11호
    • /
    • pp.3433-3440
    • /
    • 1996
  • This paper was investigation of the stres corrosion cracking(SCC) mechanism and the properties of corrosion fracture surface of glass fiber reinforced plastics(GFRP) produced by hand lay up(HLU) method in synthetic sea water. Test material is GFRP, that was used vinylester type epoxy acrylate resin and an unsaturated polyester as the matrix and the chopped strand mat(CSM) type E-glss fiber as the reinforcement. The slow strain rate test(SSRT) was performed on dry, wet and saturated wet specimens in sea water. Here the pH concentration of synthetic sea water was 8.2 and the strain rate is 1 x $10^{-6}$($sec^{-1}$) and test temperature ranges varied from $-60^{\circ}C$ to $80^{\circ}C$. It could be confirmed the fact that wet specimens tested at a particular test temperature ranges were appeared the eviences of SCC such as con-planar, mirror and hackle zone. Moreover, SCC of GFRP in sea water was characterised by falt fracture surfaces with only small amounts of fiber pull-out, in partial.

잠재적 화재.폭발 위험 지역 작업용 녹전환형 중방식 코팅제의 특성에 관한 연구 (A Study on the Properties of the Heavy Duty Rust-Converting Agent used in the Potential Hazard Areas of Fire & Explosion)

  • 강영구
    • 한국안전학회지
    • /
    • 제13권3호
    • /
    • pp.102-111
    • /
    • 1998
  • This study was concerned with the development of a heavy duty rust-converting agent, the function of which is to form metal complex coatings, containing vinyl halide-acrylic terpolymer emulsion, defoamer, emulsifying agent, glass flakes, chelating agent such as gallotannic acid, gallic acid, and pyrogallic acid, and other additives. The resulted emulsion products(Sample No.1~No.5) were characterized through test either in the forms of emulsions, which include Viscosity, Penetration rate, Acidity and Film drying rate test, or in the forms of coated layer on rusty steel substrates by FT-IR, which include hardness, gloss, salt spray, adhesion and flame retardant test. The test results are as follows ; Penetration rate(0.1~0.4 mm/min), Solid content(70%), Acidity (pH 1.8~2.0), Specific gravity(1.30~1.35), Film drying rate(108min, RH 40% ; 150min, RH 80%), Gloss(83~92, incident angle $60^{\circ}$; 88~97, incident angle $85^{\circ}$), Pencil hardness(4H~5H), Adhesion (100/100), Salt spray test(>720Hr), LOI(%) value(38%), Vertical burning test(UL 94-v-l). According to the various performance of specimens show above, the evaluation of the availability of this heavy duty rust-converting agent can be concluded that all the samples(No.1~No.5) are capable of being used in the field of chemical plant and in the hazard areas of fire and explosion potential. It was observed that the properties of sample No.2, especially gloss and hardness, were much better than that of the other samples.

  • PDF

시험편 제작방법 변경에 따른 페인트, 퍼티의 TVOCs의 방출 특성 비교 (Comparison of TVOCs emission characterization of paint and putty according to the amendment of test specimen preparation method)

  • 박준만;유지호;김만구
    • 분석과학
    • /
    • 제23권2호
    • /
    • pp.109-118
    • /
    • 2010
  • 이 연구에서는 2008년에 개정된 "다중이용시설 등의 실내 공기 질 관리법"의 시행규칙 중에서 페인트와 퍼티의 시험방법과 개정된 시험방법을 비교하고 변경된 관리기준의 변화 방향에 대해서 알아보았다. 페인트의 경우 개정된 시험방법은 시험기간의 변경으로 인하여 원래 시험방법에 의한 방출강도 보다 약 45% 감소하였으며, 건조시간의 변화에 따른 방출강도의 영향은 없었다. 또한 도포량의 변화에 따른 방출강도의 변화는 $5\;mg/m^2h$ 이상의 높은 방출 강도를 가지는 제품은 방출강도의 변화가 크나 그 이외의 제품들에서는 방출강도의 변화가 없었다. 퍼티의 경우 개정된 시험방법은 시험기간의 변경으로 원래 시험방법에 의한 방출강도 보다 평균 61% 감소하였고, 건조시간의 변화에 따른 방출강도의 영향은 없었다. 그러나 퍼티의 도포량의 변화로 인하여 원 시험방법에 의한 방출강도보다 약 164% 증가 하였다. 개정된 시험방법에 따른 변경된 TVOCs의 관리기준은 페인트와 퍼티 모두 원래 시험방법에 의한 과거의 관리기준 보다 각각 1.8배 및 5.8배 완화된 것으로 나타났다.

Human Papillomavirus Prevalence and Genotype Distribution in Normal and ASCUS Specimens: Comparison of a Reverse Blot Hybridization Assay with a DNA Chip Test

  • Kim, Sunghyun;Lee, In-soo;Lee, Dongsup
    • 대한의생명과학회지
    • /
    • 제21권1호
    • /
    • pp.32-39
    • /
    • 2015
  • High-risk (HR) human papillomavirus (HPV) genotypes are strongly associated with cervical cancer, whereas other HPV genotypes are not. To identify the various HPV genotypes in clinical samples, we conducted HPV genotyping using a DNA chip test and reverse blot hybridization assay (REBA) in normal cytology samples and atypical squamous cells of undetermined significance (ASCUS) cytology samples. We also investigated the HPV infection rate and HPV genotype prevalence in women with normal cytology and ASCUS cytology. Liquid-based cytology preparations were used for the initial screening of 205 subjects with normal cytology and ASCUS cytology. The HPV infection rate was 49.8% when using the DNA chip assay and 61.0% when using the REBA test. In patients with normal cytology, the HR-HPV positive rate was 21.9% with the DNA chip assay and 43.9% with the REBA test. In contrast, 8.3% of patients with ASCUS were HR-HPV positive when using the DNA chip assay, and 13.6% were positive when tested with the REBA test. The infection rate of HR-HPV in the 40~50-year age group was significantly higher than that of the other age groups. Based on the cytological analysis of the normal and ASCUS samples, the five most prominent HPV genotypes were HPV 16, 18, 68, 33, and 58 using the DNA chip test, and they were HPV 16, 18, 53, 33, and 66 when using the REBA test. In conclusion, the findings show that the results of the REBA test are comparable to those of the DNA chip test. Most strikingly, the REBA test detected the HR-HPV genotype associated with cervical carcinoma similar to that detected with the DNA chip method. Therefore, the REBA test is a useful method to detect clinically important HR-HPV genotypes.

Stress corrosion index of Kumamoto andesite estimated from two types of testing method

  • Jeong Hae-Sik;Nara Yoshitaka;Obara Yuzo;Kaneko Katsuhiko
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.221-228
    • /
    • 2003
  • The stress corrosion index of Kumamoto andesite are evaluated by two types of testing method. One is the uniaxial compression test under various water vapor pressures, and the other is the double torsion (DT) test under a constant water vapor pressure. For the uniaxial compression tests, the uniaxial compressive strength increases linearly with decreasing water vapor pressure on the double logarithmic coordinates. As the results, the stress corrosion index obtained is estimated 44. On the other hand, in the DT test, the relaxation (RLX) test and the constant displacement rate (CDR) test were conducted. For the CDR test, as the displacement rate of loading point increases, the crack velocity increases. However, the fracture toughness is constant regardless of the change in displacement rate and the average fracture toughness is evaluated $2.07MN/m^{3/2}$. For the RLX test, the crack velocity-stress intensity factor curves are smooth and linear. The stress corrosion index estimated from the curves is 37. Comparing stress corrosion indexes in the uniaxial compression test and the DT test, there is no significant difference in these values, and they are considered to be in coincident each other regardless of testing methods. Therefore, it is concluded that stress corrosion is one of material constants of rock.

  • PDF

20대 남성의 치아우식발생요인에 관한 연구 (STUDY ON THE CARIOGENIC FACTORS IN THE MALE KOREAN TWENTIES)

  • 백대일
    • 대한치과의사협회지
    • /
    • 제15권2호
    • /
    • pp.145-151
    • /
    • 1977
  • The author performed Snyder test, estimation of salivary flow rate, salivary viscosity test, salivary buffering capacity test, M-R test, oral hygiene ability test, estimation of oral glucose clearance time and plaque reformation test in the 107 male Koreans aged form the age of 20 to 29, in order to detect and control the active cariogenic factors contributing to caries development on the individual basis. Thereafter, the data from 8 kinds of caries activity test were analysed and evaluated. The obtained results were as follows: 1. Snyder test was positive in 86.0% of total tested persons, and among those showing positive Snyder test reaction, slight caries activity was appeared in 39.1%, moderate caries activity in 23.9%, and marked caries activity in 37.0%. 2. Salivary flow rate was under the average flow amount in 53.3%. 3. Salivary buffering capacity was low in 22.4%. 5. Buffering capacity of dental plaque was high in 12.5%. 6. Oral hygiene ability was insufficient in all persons tested. 7. Oral glucose clearance time was long in 42.1%. 8. Plaque reformation rate was high in 8.4% of the 107 persons tested.

  • PDF

피로균열 성장과정에 대한 평가방법의 영향 (Influence of Evaluation Methods for Fatigue Crack Growth Process)

  • 안철봉
    • 한국생산제조학회지
    • /
    • 제8권1호
    • /
    • pp.119-125
    • /
    • 1999
  • The distribution of fatigue crack growth rate is subjected to the measuring interval and calculated method of growth rate. In this paper, in order to establish the method of determining the distribution of fatigue crack growth rate, which ignores those influences, a series of fatigue crack growth experiments and measuring intervals of crack length calculated reasonable are presented. The main conclusions obtained are summarized as follows: 1) As a result of the ΔP constant test and ΔK constant test, it is thought that an approximate measuring interval of 0.3~0.7mm is reasonable, which allows for few errors and is little subjected to the calculated method of crack growth rate. 2) After generally comparing the error estimation by using the experimental data of CCT specimen with the error rating of the CT specimens, it is possible that the fatigue test has few errors within the measuring interval, ξ(Δa/W)=0.0067~0.017, regardless of the dimension of specimen geometry.

  • PDF