• Title/Summary/Keyword: Rate Test

Search Result 13,532, Processing Time 0.039 seconds

The System Position from High Firing Rate of Anti-Aircraft Gun system (고발사율 대공포 발사에 따른 체계자세 연구)

  • Hwang, Boo Il;Lee, Boo Hwan;Kim, Chi Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.6
    • /
    • pp.611-615
    • /
    • 2015
  • Anti-aircraft gun system is used for low-level air defense system and has more than twin guns with high firing rate in order to maximize the capability of defense. Gun's vibration and bullet's variance has a critical effect on accuracy and hit probability of weapon system such as anti-aircraft gun system with high firing rate. Typical mechanism to reduce the amount of vibration and shock during gun-fire process is very important design factor. In this paper, the suspension characteristics of the vehicle are studied for the improvement of isolating performance of gun firing system with high firing rate. Gun fire test for the vehicle is conducted and computational models using Recurdyn and Adams are created based on test results. Through this study, results of computational analysis are compared with the real test results, which includes type, location and quantity of suspension and gun mechanism are selected for anti-aircraft gun. From the result of this study, we could make basic design and consider the proper component of the system such as suspension and gun spring.

Determination of Forward Dissolution Rate of Glass by a Single-Pass Flow-Through Test (Single-Pass Flow-Through Test방법에 의한 유리의 정용해율 측정)

  • Kim Seung-Soo;Chun Kwan-Sik;Choi Jong-Won;Kim Sung-Ki;Hahn Pil-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.4
    • /
    • pp.335-340
    • /
    • 2005
  • The forward dissolution rate of a borosilicate waste glass was determined as an interlaboratory study(ILS) testing program for the evaluation of precision in the measurement of the dissolution rate or a waste glass using a single-pass flow-through(SPFT) test, whose conducting practice has been written for standardization through American Society for Testing and Materials (ASTM). A simulated low-activity waste glass powder with a size of 100/200 mesh was dissolved by lithium buffer solution (pH=10) at 70? under Ar atmosphere. By plotting the dissolution rates as a function of silicon and boron concentration in eluate, the forward dissolution rate of the glass was obtained as about $2.7\times10^{-5}g{\cdot}m{\cdot}s^{-1}$ in our laboratory.

  • PDF

Flow-accelerated corrosion assessment for SA106 and SA335 pipes with elbows and welds

  • Kim, Dong-Jin;Kim, Sung-Woo;Lee, Jong Yeon;Kim, Kyung Mo;Oh, Se Beom;Lee, Gyeong Geun;Kim, Jongbeom;Hwang, Seong-Sik;Choi, Min Jae;Lim, Yun Soo;Cho, Sung Hwan;Kim, Hong Pyo
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.3003-3011
    • /
    • 2021
  • A FAC (flow-accelerated corrosion) test was performed for a straight pipe composed of the SA335 Gr P22 and SA106 Gr B (SA106-SA335-SA106) types of steel with welds as a function of the flow rate in the range of 7-12 m/s at 150 ℃ and with DO < 5 ppb at pH levels ranging from 7 to 9.5 up to a cumulative test time of 7200 h using the FAC demonstration test facility. Afterward, the experimental pipe was examined destructively to investigate opposite effects as well as entrance effects. In addition, the FAC rate obtained using a pipe specimen with a 50 mm inner diameter was compared with the rate obtained from a rotating cylindrical electrode. The effects of the complicated fluid flows at the elbow and orifice of the pipeline were also evaluated using another test section designed to examine the independent effects of the orifice and the elbow depending on the distance and the combined effects on orifice and elbow. The tests were performed under the following conditions: 130-150 ℃, DO < 5 ppb, pH 7 and a flow rate of 3 m/s. The FAC rate was determined using the thickness change obtained from commercial room-temperature ultrasonic testing (UT).

Comparative Estimation of Exposure Level and Health Risk Assessment of Highly Produced Pesticides to Agriculture Operators by Using Default Dermal Absorption Rate or Actual Measurement Values

  • Kim, Su-Hyeon;Lee, Chang-Hun;Kim, Ki-Hun;Jeong, Sang-Hee
    • Biomedical Science Letters
    • /
    • v.22 no.4
    • /
    • pp.199-206
    • /
    • 2016
  • Pesticides are widely used to prevent loss of agricultural production but extensive exposure can induce health problems to pesticide operators. This study was performed to evaluate the health risk of highly produced pesticides used in fruit growing farm land by comparison of estimated exposure level with AOEL using KO-POEM program. AOEL was driven based on NOAEL of each pesticide evaluated by JMPR, EFSA or KRDA. In calculation of exposure level, types of formulation, dilution factors, spraying duration and motor type and exposure protection device were allocated according to actual condition of use. Dermal absorption rate was differently applied among EFSA default values (25% or 75%), general default value (10%) or real test result values to know the plausibility of default values and safety of pesticide to operators in outline. Twenty pesticide ingredients (fungicides and insecticides) were produced more than 30 tons per year, which were mancozeb, chlorothalonil, imidaclopirid and etc in order. Dermal absorption rates obtained from studies were various from 0.07 to 81% but mostly under 10%. The estimated exposure levels showed big differences more than 10 times higher when using EFSA default rate and up to 5 times higher when using general rate of 10% comparing using rates of test results. Mancozeb, chlorthalonil, diazinon and chlorpyrifos presented still higher exposure level than AOEL even when using test absorption rate from study, which suggests that re-evaluation of AOEL or dermal exposure absorption rate or strict management are required for health protection of operators who use those four pesticides in farm land.

Bioactivity of $CaO-P_2O_5-SiO_2$ Glasses ($CaO-P_2O_5-SiO_2$계 유리의 생체활성)

  • 조정식;김철영
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.6
    • /
    • pp.433-440
    • /
    • 1993
  • The bioactivity of glasses in the CaO-SiO2 system and CaO-P2O5-SiO2 system with less than 10mol% of P2O5 was investigated by in vitro test in simulated body flood(SBF). The formation of Ca.P film and hydroxyapatite on the surface of glasses after in vitro test was analysed by X-ray photoelectron spectoscopy (XPS), fourier transform infrared reflection spectroscopy (FT-IRRS), energy dispersive X-ray spectroscopy (EDS), and scanning electron microscopy (SEM) observation. In the early stage of Ca.P film formation after in vitro test for CaO-SiO2 and CaO-P2O5-SiO2 glasses, the rate of Ca.P film formation on the surface of the glasses was dependent of structural parameter (Y) evaluated from the glass composition. First, in the case of the glasses having Y value below 2, Ca.P film and SiO2-rich layer were formed simultaneously, and there were no differences of the rate of Ca.P film formation in terms of the Y values. Second, in the case of the glasses having Y value above 2, the SiO2-rich layer was formed, and then Ca.P.Si mixed layer was formed in the silica gel structure of the SiO2-rich layer, and finally the Ca.P film on the surface of SiO2-rich layer. The rate of Ca.P film formation delayed as the Y values increased. The rate of hydroxyapatite formation of glasses (the rate of transformation from Ca.P film to hydroxyapatite) seems to be propotional to the rate of Ca.P film formation and Y value. The rate of hydroxyapatite formation of glasses belonging to the second group was delayed as structural parameter increased, and the hydroxyapatite crystal showed spherical growth in the early reaction stage, and then showed silkworm-like linear growth as the reaction time increased.

  • PDF

High Strain Rate Tensile Test of Composite Material for Automotive Front End Module Carrier (자동차 프론트엔드모률 캐리어용 경량 복합소재의 고속인장 시험)

  • Kang, Woo-Jong;Kim, Sung-Tae
    • Composites Research
    • /
    • v.24 no.3
    • /
    • pp.12-16
    • /
    • 2011
  • High strain rate tensile tests were performed to measure the strain rate sensitivity of fiber reinforced composite material. The composite material was developed for the light weight design of an automotive FEM(front end module) carrier. Standard specimens for quasi-static tests of fiber reinforced composites can be found in ASTM D3039. However, in case of high strain rate tests, it was hard to find standard specimen shapes. In this study, three kinds of tensile specimens designed based on ASTM D638 were investigated to determined the adequate gauge width of tensile specimen for fiber reinforced composite. A drop tower type of high speed tensile apparatus was developed for strain rates of about 15/s and 100/s. Gauge width of 6mm, 8mm and 10mm were investigated. Test results showed the specimen of 8mm width was adequate for the high strain rate tensile tests of fiber reinforced composite. It was found the strength of the composite material increased as the strain rate increased.

Combustion Characteristics Analysis of a Non-class 1E Cable for Nuclear Power Plants according to Aging Period (경년열화 기간에 따른 원자력발전소용 비안전등급 케이블의 연소특성 분석)

  • Kim, Min Ho;Lee, Seok Hui;Lee, Min Chul;Lee, Sang Kyu;Lee, Ju Eun
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.5
    • /
    • pp.22-29
    • /
    • 2020
  • In this study, combustion and smoke release characteristics of a non-class 1E cable for nuclear power plants were investigated according to aging period. The aging was reproduced through an accelerated aging method for interval of 10 years :10, 20, 30 and 40 year, which was applied the Arrhenius equation. The cable was subjected to accelerated aging. In order to understand combustion and smoke release characteristics, the cone calorimeter test was performed according to the standard code of KS F ISO 5660-1. Heat release rate, mass loss rate, average rate of heat emission and smoke production rate were examined through cone calorimeter test. Fire performance index, fire growth index and smoke factor were derived from test results for the comparison of quantitative fire risk. When comparing the fire performance index and the fire growth index, the early fire risk tends to decrease as aging progresses, which might be attributed from the fact that the volatile substances of cables were evaporated. However, when comparing the heat release rate, average rate of heat emission and mass loss rate, which represent the mid and late periods of the fire risk, the values of accelerated aging cables were much higher than those of non-aged cable, which signifies the unstable formation of the char layer resulted in the change in the performance of flame retardants. In addition, the results from the smoke characteristics show that the accelerated aging cables were lager than the non-aged cables in terms of overall fire risk. These results can be used as baseline data when assessing fire risk of cables and establishing fire safety code for nuclear power plants.

A Study on Transmit Performance of Repeaters in 1x EV-DO Networks (1x EV-DO 서비스망에서 이동통신 중계기의 전송 특성에 관한 연구)

  • 김선근;이영섭;김기문
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.3
    • /
    • pp.598-604
    • /
    • 2004
  • The mobile service was focused on voice and low rate data service. But recently high data rate service is getting more important, so mobile service operators are providing 1x EV-DO services for high data rate service. Many mobile repeaters were deployed for service coverage, but most of them were deployed when voice and low rate data service were main service. It is necessary to test whether these repeaters are suitable for 1x EV-DO networks for high rate data services. In field test, 1x EV-DO data rates were measured through various repeaters. Some repeaters showed data rates degradation compared with 1x EV-DO AN. The specifications of the repeaters were analyzed. And under the various radio environments such as fading and RSSI, data rates through repeater were tested. These test results will be useful for operation guide of repeaters in high data rate service networks.

A Study on the Reliability Evaluation System for O-ring of Semiconductor Equipments (반도체장비용 오링의 종합 신뢰성 평가기술에 관한 연구)

  • 김동수;김광영;최병오;박화영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.613-617
    • /
    • 2001
  • The test items like as endurance, air leakage and oil endurance test is requested for reliability evaluation about O-ring which is a kind of core machinery accessories of semi-conduct manufacturing equipment. For verification of these, we design and manufactured a test system for endurance, air leakage and oil endurance of O-ring for semi-conduct manufacturing equipment, and also performed the test for two kinds of O-ring, as it were Viton and Kalretz. The characteristics of this test equipment consist in realization of the test conditions of semi-conduct manufacturing equipment and satisfying the test method. The test conditions are cut gas, vacuum grade, temperature and revolution numbers in the endurance test system, vacuum grade and temperature in the air leakage test system, temperature and time in the oil endurance test system. The separating test results for wearing which is an oil endurance test item, the wearing index of domestic produced Viton O-ring is higher than foreign product by 2%, wearing rate of Kalretz O-ring better than Viton O-ring by 17%, and particles existed in various place. The test result of air leakage which is measured through the RGA sensor used Helium, the vacuum grade was $10^-3$Torr. And the test result of oil endurance, the volume change rate was 7~15%. Hereafter, we intend to analysis the reliability test evaluation and to utilize for domestic manufacturing companies by establishing data base and developing reliability softwares.

  • PDF

Clinical study on treatment of HIVD of lumbar spine using Scolopendrid herbal acupuncture (오공약침(蜈蚣藥針)을 이용한 요추간판탈출증(腰椎間板脫出症) 치료(治療)의 임상적(臨床的) 연구(硏究))

  • Park, So-Yeong;Lee, Gyeong-Yun;Choe, Hoe-Gang;So, Gi-Suk;Lee, Jong-Deok;Kim, Seong-Cheol;Go, Gang-Hun
    • Journal of Pharmacopuncture
    • /
    • v.4 no.3
    • /
    • pp.47-57
    • /
    • 2001
  • Objective: This study is performed for the purpose of examining into the efficacy of the scolopendrid(Scolopendra morsitans L) which has been used among the Korean people for the H.I.V.D of lumbar spine. Methods & Results: Using the herbal acupuncture made of scolopendrid(Scolopendra morsitans L), we treated the 10 H.l. V.D patients for 1 week and operated 4 pre and post treatment test ; D.I.T.I, 6 kind of physical test, Oswestry disability index, and self-conscious pain rate. Trough Lite test, we saw 50-100% of efficacy rate in each test. Otherwise, only 5 of the 7 point in D.I.T.I and self-conscious pain rate showed statistically valuable change. Conclusion: we brought to the conclusion that the scolopendrid herbal acupuncture has possibility to be efficient to cure the H.I.V.D patients. So we suggest the possibility to use this new remedy for the H.I.V.D.