• Title/Summary/Keyword: Rapid diagnostic kit

Search Result 52, Processing Time 0.021 seconds

Comparison of chemiluminescence immunoassay (CIA) and immunochromatography assay(ICA) for Detecting HBsAg and Anti-HBs (B형 간염항원 및 항체 검사를 위한 화학발광면역검사법(CIA)과 면역크로마토그래피법(ICA)의 비교분석)

  • Kim, Hye-Jeong;Kim, Eun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3419-3424
    • /
    • 2013
  • Diverse immunoassays including a chemiluminescent immunoassay (CIA) are used to detect hepatitis B surface antigen (HBsAg) and antibody (anti-HBs). Recently, an increasing number of institutions have been utilizing an immunochromatography assay (ICA), which is easy to use. In this study, We evaluated ICA kits for the rapid detection of HBsAg and anti-HBs by comparing them with a CIA. A total of 120 serum hospital samples, were collected for the whole month, were assayed using ICA kit. The Concordance rate, sensitivity, specificity, positive predictive value and negative predictive value of the ICA for HBsAg based on CIA results were 97%, 97%, 100%, 100%, and 96.8%, respectively. The diagnostic performances of the ICA for Anti-HBs were 90%, 90%, 93.3%, 93.1%, and 90.3%, respectively. The ICA kit failed to detect HBsAg and anti-HBs in low reactive samples. The ICA kits for the rapid detection of HBsAg might be recommended for interpreted with caution and dual analysis in the clinical laboratory.

Selection of epitope for development of H5N1 specific diagnostic kit based on bioinformatics (생명정보학 기반 H5N1에 특이적인 진단키트 개발을 위한 epitope 선별)

  • Lee, In Seoung;Kim, Hak Yong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.11a
    • /
    • pp.57-58
    • /
    • 2014
  • 인플루엔자 A 바이러스의 아형인 H5N1은 고병원성으로 조류 독감을 일으킨다. H5N1 바이러스는 원래 조류끼리만 감염되는 독감이고, 사람에게는 전염되지 않는다고 알려져 있었으나, 2003년에 베트남과 중국을 시작으로 현재까지 168명의 사망자가 기록되고 있다. 그러나 현재 시판되고 있는 진단키트(Rapid diagnostic kits)들은 H5N1 에 특이적인 것이 아니라 influenza A virus 모두를 진단한다. 따라서 influenza 감염여부는 확인 할 수 있지만, 이것이 H5N1 인지는 확인 할 수가 없다. H5N1은 전염성이 강하기 때문에 빠르게 진단하여 감염조류를 살 처분 하여야 더 많은 경제적 손실을 줄일 수 있다. 따라서 H5N1 에만 특이적인 epitope를 네트워크 기반으로 예측하여 진단제에 응용할 수 있도록 하고자 한다. 각 서열 정보는 Openflu (http://openflu. vital-it.ch/browse.php)에서 얻었다. H5N1은 H1N1에서 유래되었기 때문에 두 subtype의 차이점을 알아보고자 TCOFFEE에서 multiple sequence alignment를 수행한 결과 N-terminal 부분이 상이하였다. 상이한 H5N1의 N-terminal 부분이 H5N1 virus에 감염된 모든 host에서 존재하는지 알아보기 위해 host가 사람인 경우와 조류인 경우를 TCOFFEE에서 alignment 하였다. 그 결과 H5N1의 N-terminal 부분은 사람과 조류에서 보존적이었다. 따라서 H5N1의 N-terminal이 다른 subtype과 유사하지 않고 H5에만 특이적이기 때문에 진단키트 제작을 위한 epitope로 사용할 수 있을 것으로 기대된다.

  • PDF

Development of Two Quantitative Real-Time PCR Diagnostic Kits for HPV Isolates from Korea

  • Jeeva, Subbiah;Kim, Nam-Il;Jang, In-Kwon;Choi, Tae-Jin
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.10
    • /
    • pp.1350-1358
    • /
    • 2012
  • Viral pathogens, alongside other pathogens, have major effects on crustacean aquaculture. Hepatopancreatic parvovirus (HPV) is an emerging virus in the shrimp industry and has been detected in shrimp farms worldwide. The HPV genome has greater diversity than other shrimp viruses owing to its wide host range and geographical distribution. Therefore, developing diagnostic tools is essential to detect even small copy numbers from the target region of native HPV isolates. We have developed two easy to use quantitative real-time PCR kits, called Green Star and Dual Star, which contain all of the necessary components for real-time PCR, including HPV primers, using the primers obtained from the sequences of HPV isolates from Korea, and analyzed their specificity, efficiency, and reproducibility. These two kits could detect from 1 to $1{\times}10^9$ copies of cloned HPV DNA. The minimum detection limits obtained from HPV-infected shrimp were $7.74{\times}10^1$ and $9.06{\times}10^1$ copies in the Green Star and Dual Star assay kits, respectively. These kits can be used for rapid, sensitive, and efficient screening for HPV isolates from Korea before the introduction of postlarval stages into culture ponds, thereby decreasing the incidence of early development of the disease.

Comparative Analysis of the Multiple Test Methods for the Detection of Pandemic Influenza A/H1N1 2009 Virus

  • Choi, Young-Jin;Nam, Hae-Seon;Park, Joon-Soo;Kim, Hwi-Jun;Park, Kyung-Bae;Jeon, Min-Hyok;Kim, Chang-Jin;HwangBo, Young;Park, Kwi-Sung;Baek, Kyoung-Ah
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.10
    • /
    • pp.1450-1456
    • /
    • 2010
  • Accurate and rapid diagnosis of Pandemic Influenza A/H1N1 2009 virus (H1N1 2009) infection is important for the prevention and control of influenza epidemics and the timely initiation of antiviral treatment. This study was conducted to evaluate the performance of several diagnostic tools for the detection of H1N1 2009. Flocked nasopharyngeal swabs were collected from 254 outpatients of suspected H1N1 2009 during October 2009. This study analyzed the performances of the RealTime Ready Inf A/H1N1 Detection Set (Roche), Influenza A (H1N1) Real-Time Detection Kit (Bionote), Seeplex Influenza A/B OneStep Typing Set [Seeplex Reverse Transcriptase PCR (RT-PCR)], BinaxNow Influenza A & B Test Kit [Binax Rapid Antigen Test (RAT)], and SD BIOLINE Influenza Ag kit (SD RAT). Roche and Bionote real-time RT-PCR showed identical results for the H1N1 2009 hemagglutinin gene. Compared with real-time RT-PCR, the sensitivities and specificities were 83.7% and 100% for Seeplex RT-PCR, 64.5% and 94.7% for Binax RAT, and 69.5% and 100% for SD RAT. The sensitivities of Seeplex RT-PCR, Binax RAT, and SD RAT in patients aged over 21 years were 73.7%, 47.4%, and 57.9%, respectively. The sensitivities of Seeplex RT-PCR, Binax RAT, and SD RAT on the day of initial symptoms were mostly lower (68.8%, 56.3%, and 31.3%, respectively). In conclusion, multiplex RT-PCR and RAT for the detection of H1N1 2009 were significantly less sensitive than real-time RT-PCR. Moreover, a negative RAT may require more sensitive confirmatory assays, because it cannot be ruled out from influenza infection.

Bacterial Sepsis Associated with a Captive State Caused by Edwardsiella tarda in a Eurasian Brown Bear (Ursus arctos arctos)

  • Min-Goo Seo;Kyung-Yeon Eo;Dongmi Kwak;Kyoo-Tae Kim
    • Journal of Veterinary Clinics
    • /
    • v.40 no.1
    • /
    • pp.78-82
    • /
    • 2023
  • Edwardsiella (E) tarda belongs to the Enterobacteriaceae family and is a motile, gram-negative, rod-shaped, facultative anaerobe regarded as an opportunistic and food-borne pathogen in animals and humans. A 21-year-old male Eurasian brown bear (Ursus arctos arctos) died suddenly without any preliminary signs. Necropsy performed according to standard protocol revealed swollen abdomen with hemorrhagic congestions of the gastroenteric organs, ascites, and hemorrhagic exudates around the mouth. The liver showed discoloration, along with a severely swollen and multiple hemorrhages of the spleen, an elongated gallbladder, and a congested cortex and medullar lesion of kidneys. The stomach contained semi-liquid exudates and undigested chicken exuding a decayed odor. The stomach membranes were dark-gray in color with several cysts in the fundus lesions. Rod-shaped bacteria were found in the major organs by Giemsa staining, identified as E. tarda using a biochemical rapid diagnostic identification kit.

Probability of Antibody Formation against Circumsporozoite Protein of Plasmodium vivax among Korean Malaria Patients

  • Nam, Ho-Woo;Song, Kyoung Ju;Ahn, Hye Jin;Yang, Zhaoshou;Chong, Chom-Kyu;Cho, Pyo Yun;Ahn, Seong Kyu;Kim, Tong-Soo
    • Parasites, Hosts and Diseases
    • /
    • v.52 no.2
    • /
    • pp.143-149
    • /
    • 2014
  • To evaluate the seroprevalence against circumsporozoite protein (CSP) of Plasmodium vivax in sera of Korean patients, the central repeating domain (CRD) of CSP was cloned and analyzed. From the genomic DNA of patient's blood, 2 kinds of CSPs were identified to belong to a VK210 type, which is the dominant repeating of GDRA(D/A)GQPA, and named as PvCSPA and PvCSPB. Recombinantly expressed his-tagged PvCSPA or PvCSPB in Escherichia coli reacted well against sera of patients in western blot, with the detecting rate of 47.9% (58/121), which included 15 cases positive for PvCSPA, 6 cases positive for PvCSPB, and 37 cases for both. The mixture of PvCSPA and PvCSPB was loaded to a rapid diagnostic test kit (RDT) and applied with the same set of patient sera, which resulted in detection rates of 57.0% (69/121). When the protein sequences of PvCSPA were compared with those of P. vivax in endemic regions of India and Uganda, they were compatibly homologous to PvCSPA with minor mutations. These results suggested that the recombinant PvCSPA and PvCSPB loaded RDT may be a milestone in latent diagnosis which has been a hot issue of domestic malaria and important for radical therapy in overlapped infections with P. falciparum in tropical and subtropical areas. During the biological process of malarial infection, exposure of CSP to antigen-antibody reaction up to 57.0% is the first report in Korea.

Evaluating the Usefulness of the ICT Tuberculosis Test Kit for the Diagnosis of Tuberculosis (결핵 진단에서 ICT Tuberculosis Test Kit의 효용성)

  • Chang, Chul-Hun;Son, Han-Chul;Ryu, Ki-Chan;Park, Soon-Kew;Lee, Seon-Ho;Kim, Sung-Ryul;Park, Ki-Hyung;Kim, Woo-Seok;Koo, Kyong-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.4
    • /
    • pp.473-480
    • /
    • 1999
  • Background: Early diagnosis of tuberculosis is critical, especially in Korea, an area where tuberculosis is endemic. Because antibody responses to some membrane proteins of Mycobacterium tuberculosis are not comparable, and the policy of BCG vaccination and the prevalence of tuberculosis are different from country to country, the usefulness of the serological diagnostic tests is questionable in Korea, even though they have been confirmed to be useful in other countries. In the specific context of Korea, we tried to evaluate the validity of the ICT Tuberculosis Test (ICT), a membrane-based antibody kit that purports to detect the 5 M. tuberculosis complex-specific antigens including 38-kDa protein. Method: 68 patients with tuberculosis were tested : 37 had no history of previous tuberculosis, and 31 were reactivated cases. The control group comprised 77 subjects : 25 healthy adults, 35 hospital workers with frequent contact with tuberculosis patients, and 17 in-patients with non-tuberculous respiratory diseases. Results: The diagnostic sensitivities of the ICT were 87% and 73% in patients with versus without previous history of tuberculosis, respectively. The sensitivities of smear-positive and smear-negative patient groups were 81% and 73%, respectively. Both of the two patients with extrapulmonary tuberculosis tested positive through the ICT. The specificities of the ICT were 88%, 94%, and 94% in healthy adults, hospital workers, and non-tuberculous patients, respectively, with an overall specificity of 92%. Conclusion: It is suggested that when combined with traditional techniques, the ICT is an useful tool for the diagnosis of pulmonary tuberculosis. The procedure is simple, easy to perform, rapid, and needs no equipment. It shows 73% sensitivity and 92% specificity for the diagnosis of tuberculosis.

  • PDF

Development of Enzyme Immuno Assay for Analysis of Free Prostate Specific Antigen in Serum (혈청 유리형 전립선항원 (free PSA) 측정을 위한 효소면역측정법의 개발)

  • Kyung-Ok Lee;Kyung-In Kim;Kyu-Pum Lee
    • Biomedical Science Letters
    • /
    • v.3 no.2
    • /
    • pp.107-114
    • /
    • 1997
  • Recent reports indicate that the clinical usefulness of prostate specific antigen (PSA), particulary in the differentiation of benign prostate hyperplasia from prostate cancer, can be improved by measuring the amount of free PSA in serum. Measuring free PSA is especially useful in attempts to improve diagnositc performance of PSA in the diagnostic gray zone of total PSA. The objective of this study was to develop free PSA assay kit using sandwich microplate enzyme immunoassay format. We chose a test format with polyclonal anti-PSA antibodies coated on the wells and monoclonal anti-free PSA antibodies for quantification to gain higher test sensitivity. We adpoted 10 uL of specimen and 2 hours of first incubation time with detecting antibody for free PSA EIA format using microplate. The within-day and between-day precision (%CV) in the high and low concentration ranges were below 4%. The correlation coefficient between in-house free PSA assay and commercial assay kit was r=0.9965 (slope=0.0984, y intercept=0.0173, N=27). No hook effect was found by 40 ng/mL and correlation coefficient (r) value of the fitted linear regression was over 0.995. The recovery tests were in the range of 98.9∼104.1% for free PSA. In conclusion, in-house free PSA enzyme immune assay is cost effective, simple and rapid and could be useful for the prognosis after theraphy as well as for the differential diagnosis between prostate cancer and benign prostate hyperplasia.

  • PDF

Artificial Insemination and Delivery Rate of Crossbred Goat using Frozen-Thawed Semen (동결정액을 활용한 교잡종 염소의 인공수정 효율 및 분만율 조사)

  • Kim, Kwan-Woo;Lee, Eun-Do;Lee, Jinwook;Kim, Dong-Kyo;Lee, Sung-Soo;Lee, Sang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.181-186
    • /
    • 2020
  • This study examined the artificial fertilization efficiency of crossbred goats from a farmhouse using frozen semen. Electrostimulation was used to ejaculate and collect semen to assess the artificial fertilization efficiency of crossbred goats. The sperm concentration, vitality, and vitality after melting were investigated. The sperm volume was within 2.5~3 ml, and the concentration was 21~25 × 108/ml for each male crossbred goat. The melted semen had high vitality (≥90%). An IDEXX Rapid Visual Pregnancy Test kit was used for an earlier diagnosis of the pregnancy and to determine the pregnancy rate of fertilization using frozen-thawed semen. The reproductive performance of the artificially fertilized crossbred goats had the highest delivery rate (68%) from Farm C and the lowest delivery rate (45%) from farm A. The delivery rate through artificial fertilization was equal to the fertilization rate according to early pregnancy diagnostic kits. The artificial insemination efficiency was 45~68%. These findings can be used as the basis for improvement and breeding goats in goat farms and livestock research institutes.

Evaluation of Avian Influenza and Newcastle Disease Virus Detection Kit using Field Samples from Domestic and Semi-domestic Birds (닭과 야생사육조류로부터 야외샘플을 사용한 조류인플루엔자와 뉴캣슬병 바이러스 검출 키트의 평가)

  • Rahman, Md. Siddiqur;Malek, Md. Abdul;Islam, Md. Alimul;Uddin, Muhamad Jasim;Ahasan, Md. Shamim;Chakrabartty, Amitavo;Sakib, Md. N.;Chae, Joon-Seok
    • Journal of Veterinary Clinics
    • /
    • v.29 no.4
    • /
    • pp.309-314
    • /
    • 2012
  • The study was undertaken to evaluate sensitivity and specificity of rapid Avian Influenza (AI) and Newcastle Disease virus (NDV) combo antigen kits from field samples of domestic (broiler and layer chicken, native chicken) and semi-domestic (duck, goose, pigeon and quail) birds of Bangladesh. Samples were collected from naturally infected AI suspected domestic and semi-domestic birds of five different outbreak areas in Bangladesh. From each area two birds were selected for sampling, and from each bird three types of samples (tracheal, cloacal and oro-nasal swabs) were collected. A total of 210 field samples from a total of 70 birds were collected and tested using AI and NDV combo antigen rapid diagnostic kits in the study. All three different samples from a bird showed similar pattern of reaction. Out of 210 samples, 15 samples (5 birds), 63 samples (21 birds) and 27 samples (9 birds) were positive for AIV, NDV and both for AIV and NDV, respectively; whereas the remaining birds were negative for either AIV or NDV in this screening test. Among the five AIV positive, a layer chicken from wet market in Mymensingh, Netrokona, Gibandha and Kurigram and a native chicken from wet market in Kurigram area was positive to AIV. The semi-domestic birds are either positive to NDV or free from both AIV and NDV. This study revealed that the AIV and NDV rapid diagnostic kits could be effectively use to diagnose the respective virus in trachea, oro-nasal and cloacal samples simultaneously. AIV-NDV combo Ag test result clearly indicates that the test kit designed for AIV and NDV could diagnose the disease rapidly with less effort and higher scientific know how which could be used for the detection of AIV and NDV using field samples in large scale.