• Title/Summary/Keyword: Rapid connection and disconnection of a power to a load

Search Result 2, Processing Time 0.019 seconds

Analysis of An Improved Short-circuit Protection for Multilevel PWM ac/dc Converter (멀티레벨 PWM ac/dc 컨버터의 향상된 단락보호기법 해석)

  • Kang S. K.;Nho E. C.;Kim I. D.;Joe C. J.;Chun T. W.;Kim H. G.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.193-196
    • /
    • 2001
  • This paper describes an improved short-circuit protection for a multilevel ac/dc power converter The output do power of the proposed converter can be disconnected from the load within several hundred microseconds at the instant of short-circuit fault. Once the fault has been cleared the dc power is reapplied to the load. The rising time of the do load voltage is as small as several hundred microseconds, and there is no overshoot of the dc voltage because the do output capacitors hold undischarged state. Therefore, the proposed converter can be used for a power supply, which requires a rapid disconnection of the load from the power supply in the case of a short circuit, as well as a rapid connection the load to the power supply after the clearance of the short circuit condition.

  • PDF

A New Ac-to-Dc Power Converter for a Load with Frequent Short Circuits (부하단락이 빈번히 발생하는 경우에 적합한 교류-직류 전력변환기)

  • No, Ui-Cheol;Kim, In-Dong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.7
    • /
    • pp.384-390
    • /
    • 1999
  • This paper describes a new ac-to-dc power converter using a multilevel converter. A conventional multilevel ac-to-dc converter has large output dc filter capacitors. When a short circuit happens in a load, the stored energy in the capacitors should be discharged through the load with a high short circuit current. The high current may cause considerable damage to the capacitors and the load. The output dc capacitors of the proposed converter do not discharge even under load short circuit condition. In the case of a load short circuit, the capacitors become a floating state immediately and remain in the state. Then the stored capacitor energy is supplied to the load again as soon as the short circuit has been cleared. Therefore, the rising time of the load voltage can be significantly reduced. This feature satisfies the requirement of a power supply for a load with frequent short circuits. The proposed converter has the characteristics of a simplified structure, a reduced cost, weight, and volume compared with conventional power supplies with frequent output short circuits. Experimental results are presented to verify the usefulness of the proposed converter.

  • PDF