• 제목/요약/키워드: Ranges

검색결과 7,078건 처리시간 0.036초

중고주파에서의 새로운 진동해석시스템, PFFEM 개발연구 (Development of PFFEM, the new vibroacoustic analysis system in medium-to-high frequency ranges)

  • 서성훈;홍석윤;박도현;길현권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.325-333
    • /
    • 2000
  • To predict vibrational energy density and intensity of partitioned complex system structures in medium-to-high frequency ranges, Power Flow Finite Element Method(PFFEM) programs for the plate elements are developed. The flexural, longitudinal and shear waves in plates are formulated and the joint element equations for multi-couped plates are fully developed. Also the wave transmission approach has been introduced to cover the energy transmission and reflection at the joint plate elements. Using the developed PFFEM program the energy density and intensity of the submarine and automobile shape structures are predicted with a harmonic point force at a single frequency.

  • PDF

수변 공사에 의한 충격음의 특성과 어류에 미치는 영향 (Characteristics of Impulsive Noise of Waterfront Construction Site and Its Effects on Fishes)

  • 배종우;박지현;윤종락
    • 한국소음진동공학회논문집
    • /
    • 제19권9호
    • /
    • pp.928-934
    • /
    • 2009
  • Underwater impulsive sound such as underwater blasting noise, piling noise and stone breaking hammer affects marine animal hearing response and organs. This study describes the characteristics of various impulsive noise from waterfront construction site and their effect on fish. Time constant, peak pressure, energy and SEL(sound exposure level) of four different underwater impulsive sounds are quantified. Auditory and non-auditory tissue damage ranges are derived by comparing their quantities to the exposure criteria for fish. Damage ranges of auditory tissue and non-auditory tissue of underwater boring blast of 150 kg of charge, are about 100 m and 300 m, respectively. Other three impulsive sounds also gives damage effects but less than that of underwater boring blast.

304 스테인레스강의 고온 유동응력곡선과 미세조직의 예측 (Prediction on Flow Stress Curves and Microstructures of 304 Stainless Steel)

  • 조범호
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 춘계학술대회논문집
    • /
    • pp.171-175
    • /
    • 1999
  • the high temperature deformation behavior of 304 stainless steel was characterized by the hot torsion test. Continuous deformation was carried out at the temperature ranges 900-110$0^{\circ}C$ and the strain rate ranges 5x10-2~5/sec. The formulation of the flow stress curves was developed as subtraction form which was based on dynamic softening mechanisms The volume fraction of dynamic recrystallization and the mean grain size could be expressed as a function of deformation variables temperature (T) strain ($\varepsilon$) strain rate ($\varepsilon$) The calculated values of flow stress and mean grain size could be well matched with experimental values.

  • PDF

무선 통신용 아이솔레이션 디텍터에 사용되는 평면형 안테나 설계 (Design of a Planar Antenna for Wireless Communication Isolation Detector)

  • 박기언;허유강;이준광;문상윤;조영기
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.454-458
    • /
    • 2003
  • It is well known that the antenna for wireless Tx/Rx isolation detector should have the broadband characteristics. Such antennas can be applied in all the frequency ranges such as Cellular, PCS, IMT-2000. In this paper, using the Finite-Difference Time-Domain(FDTD) method, one design example is given for the antenna operating in the frequency ranges of $800MHz{\sim}900 MHz$, $1.7GHz{\sim}2.2GHz$.

  • PDF

전류변성기 비교기의 비오차 평가 기술 (Evaluation Technique for Ratio Error of Current Transformer Comparator)

  • 김윤형;한상길;정재갑;한상옥
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.291-295
    • /
    • 2008
  • We have developed an evaluation technique for ratio errors of current transformer (CT) comparator by using the precise standard capacitors. By applying this technique for equivalent circuit of CT comparator evaluation system, we can obtain the calculated and measured ratio errors in the CT comparator. Thus we can evaluate ratio errors of CT comparator by comparing the calculated and measured ratio errors. Because this method requires only the standard capacitors, it is simple and easy method to reliability and accuracy maintenance of CT comparator. The method was applied to CT comparator under test with the ratio error ranges of $0{\sim}{\pm}10%$. The ratio error of the CT comparator under test theoretically obtained in this method are consistent with that measured for same CT comparator under test by using wide ratio error CT within an estimated expanded uncertainty (k = 2) in the overall ratio error ranges.

교번 스위치를 활용한 시공간 및 주파수공간 블록 코딩의 하이브리드 알고리즘 (Hybrid Algorithm of Space Time and Space Frequency Block Coding Technique using Alternate Time Switch)

  • 정혁구
    • 전기학회논문지P
    • /
    • 제66권1호
    • /
    • pp.48-52
    • /
    • 2017
  • This paper proposes a hybrid algorithm of space-time block coding and space-frequency block coding using alternate time switch. The traditional alternate time-switched space-time or space-frequency block coding technique for orthogonal frequency division multiplexing system does not provide a good performance with a variety of communication environments. This hybrid algorithm has searched good performance ranges in various environments in view points of mobile speed and doppler frequency. In this paper, we investigate better performance ranges for two algorithms, suggest a hybrid algorithm for dynamically changing communication environments, propose a structure for transmitter and receiver, and show that its performance is better than the traditional algorithm by simulations.

Enzymatic Properties of Protease from the Hepatopancreas of Shrimp, Penaeus japonicus

  • Kim Hyeung-Rak
    • Fisheries and Aquatic Sciences
    • /
    • 제3권3_4호
    • /
    • pp.188-194
    • /
    • 2000
  • A protease purified from hepatopancreas of shrimp, Penaeus japonicus, had maximum activity at $70^{\circ}C$ and in neutral and alkaline pH ranges. Specific activity at optimum reaction condition of the protease was estimated to be approximately 12 U/mg/min. The protease was stable in neutral and alkaline pH ranges and activity was retained after heat treatment at $50^{\circ}C$ for 30 min. Apparent $K_m$ and $V_{max}$ value against casein substrate were estimated to be $0.29\%$ and $7.8see^{-1}$, respectively, and those against N-CBZ-L-tyrosine p-nitropheny1 ester (CBZ­Tyr-NE) were 0.38 mM and $2,400 see^{-1}$, respectively. The N-termina1 sequence of the protease showed high homology to the trypsin from same species and the proteases from shrimp. Myosin heavy chain (MHC) from shrimp tail meat was the most susceptible to the protease and actin/tropomyosin were degraded progressively during 4 hr incubation, but to a lesser degree than MHC.

  • PDF

탄도미사일의 비행궤적 특성 해석 (Analysis of the Flight Trajectory Characteristics of Ballistic Missiles)

  • 권용수;최봉석
    • 한국국방경영분석학회지
    • /
    • 제32권1호
    • /
    • pp.176-187
    • /
    • 2006
  • 탄도미사일은 비행속도가 매우 빠르고 불안정한 하강운동에 기인하는 나선형과 같은 고유의 특이한 비행운동으로 인해 정확한 비행궤적의 추정이 어렵다. 이 논문은 탄도미사일의 비행궤적 특성에 대한 종합적인 해석을 기술한다. 최대사거리를 포함 다양한 미사일 비행사거리에 따른 비행궤적특성이 해석적 방법에 의해 도출되었다. 최대사거리를 줄여 발사했을 때 비행특성에 따른 위협이 급격히 증가됨을 해석적으로 나타냈다. 이 연구는 하층미사일방어체계 구축의 운용개념 설정에 대한 기반연구이다.

The Classification of the Software Quality by the Rough Tolerance Class

  • Choi, Wan-Kyoo;Lee, Sung-Joo
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제4권2호
    • /
    • pp.249-253
    • /
    • 2004
  • When we decide the software quality on the basis of the software measurement, the transitive property which is a requirement for an equivalence relation is not always satisfied. Therefore, we propose a scheme for classifying the software quality that employs a tolerance relation instead of an equivalence relation. Given the experimental data set, the proposed scheme generates the tolerant classes for elements in the experiment data set, and generates the tolerant ranges for classifying the software quality by clustering the means of the tolerance classes. Through the experiment, we showed that the proposed scheme could product very useful and valid results. That is, it has no problems that we use as the criteria for classifying the software quality the tolerant ranges generated by the proposed scheme.

Electrochemical Diagnosis of Magnesium Ion in Fish Liver and Mice Droppings

  • Lee, Chang-Hyun;Ly, Suw Young
    • 한국응용과학기술학회지
    • /
    • 제31권4호
    • /
    • pp.663-668
    • /
    • 2014
  • An in-vivo diagnosis of trace Mg(II) ion was performed using a low-cost and environment-friendly voltammetric method, using a graphite counter and reference electrodes and a fluorine-immobilized graphite working electrode, and clean deep seawater was used as an electrolyte solution. Under optimum conditions, the analytical working ranges attained microgram ranges, and a detection limit of $80.6ugL^{-1}$ was obtained using stripping voltammety with 60 sec accumulation time. Ex-vivo application was performed on fish liver and mice droppings. The developed techniques can be applicable to tumor cell analysis.