• 제목/요약/키워드: Ranges

검색결과 7,053건 처리시간 0.028초

Salinity and Sediment Types as Sources of Variability in the Distribution of the Benthic Macrofauna in Han Estuary and Kyonggi Bay, Korea

  • Hong, Jae-Sang;Yoo, Jae-Won
    • Journal of the korean society of oceanography
    • /
    • 제31권4호
    • /
    • pp.217-231
    • /
    • 1996
  • The distribution patterns of the benthic macrofauna of Han Estuary and Kyonggi Bay and the controlling environmental factors were studied at twenty-five stations in spring and fall of 1989. As a result, four biological groups were established as follows : Crassostrea gigas-Balanus reticulatus (Group I), Heteromastus filiformis-Mediomastus californiensis-Lumbrineris spp. -Sternaspis scutata-Tharyx sp. 1-Diopatra bilobata (Group II-A), Haustoriids-Phoxocephalids-Moerella rutila (Group II-B) and Nephtys chemulpoensis (Group II-C in March) and indistinctive group which was composed of common species (II-C in September). Results of the habitat analysis revealed that most of the dominant species showed narrow ranges of habitat niche in March and relatively wide ranges in September. Based on multiple discriminant analysis, the critical environmental factors governing their distributions are salinity in the regions of Yomha and Sokmo Channel in Han Estuary and sediment types in Kyonggi Bay. Also, sediment instability during the rainy season due to run-off was assumed to play a major role in the species composition of the benthic communities and their distribution in the study area.

  • PDF

지상 기동 무기 체계에 장착된 미사일 경고 레이더의 간섭에 대한 연구 (A Study for Interference of the Missile Warning Radar in the GVWS)

  • 박규철;홍성용
    • 한국군사과학기술학회지
    • /
    • 제11권2호
    • /
    • pp.5-15
    • /
    • 2008
  • Cooperation between the GVWS within a few hundred meters has forced MWRs equipped to have service ranges in such a short ranges as well as the limited numbers of channels are available. This kind of situation often produces the frequency interferences between MWRs due to the easy uses of the common and adjacent frequencies between them. Current work provides the details of the frequency interferences and the possible degrees of detections. It is also described that the effective distances for the operation between the GVWS are investigated when they use the common and the adjacent frequencies each other with the factors as the frequency intervals and the antenna arrangement angles.

Identification of MgII Absorbers in the Quasar Lines of Sight

  • Shim, Hyunjin
    • 천문학회보
    • /
    • 제40권1호
    • /
    • pp.75.3-75.3
    • /
    • 2015
  • Large area infrared surveys are often accompanied with follow-up optical spectroscopic surveys that has a significant legacy value even for other areas of research. Using these spectral database, we have performed a search for MgII absorption lines in the optical spectrum of background quasar. Over the ~4deg2 of AKARI North Ecliptic Pole survey field and Spitzer First Look Survey field, 18 and 16 MgII absorber systems are identified respectively. The redshift range for the background quasars was 1.0<$z_{qso}$<3.4, while the redshift range for the absorber was 0.6<$z_{abs}$<1.6. Galaxies responsible for MgII absorptions are identified in the deep optical images (CFHT r-band), yet the identification still remains ambiguous for 60% of the systems due to the limited image depth and the source crowdedness. The impact parameter ranges 20-60kpc, and the rest-frame equivalent width of MgII absorption ranges $0.7-4{\AA}$. The most critical part in the identification of MgII absorber galaxies is the existence of deep optical images in addition to the high S/N quasar spectrum with R>3000.

  • PDF

변전소 건설로 인한 자기장 노출범위설정에 관한 연구 (Study for Exposure Limits of Magnetic Fields in the Transformer Substation)

  • 전인수
    • 환경영향평가
    • /
    • 제14권4호
    • /
    • pp.195-202
    • /
    • 2005
  • The health risks from the magnetic fields exposure have been brought out difficulties in the construction of transformer substation. According to several epidemiologic studies and the relevant international organizations, magnetic fields should not exceed the exposure limits of 3mG for the people living near electric power lines. The rigid regulation of the exposure levels for the elementary school and residental areas has been established already in Switzerland and Italy. Since 1998, the environmental impact assessment system in Korea has been reviewed for power-frequency magnetic field by precautionary policies. In this study, the possible application of Prior Environmental Performance Review System for the transformer substation was reviewed from the points of the properties of the powerfrequency magnetic fields. The ranges and survey methods of the assessment for the transformer substation were proposed. The ranges of magnetic fields was between 300m to 500m for the 345kV transformer substation. It is necessary to develop further specific assessment methods for various high-voltage transformer substations.