• Title/Summary/Keyword: Range time

Search Result 11,274, Processing Time 0.041 seconds

A Study on the Character of Observation Time in order to Draw the Features of Spatial Primacy Effect - Focus on the Public space - (공간의 초두효과 특성 도출을 위한 주시시간특성에 관한 연구 - 공공공간의 로비를 대상으로 -)

  • Kim, Jong-Ha
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.6
    • /
    • pp.137-146
    • /
    • 2012
  • This study introduced the concept of Primacy Effect for the analysis of the observation characters by time so as to analyze the characters of information which the users observing the lobby in a public space get when they encounter the space. From the viewpoint that the first impression on any space can motivate the judgement of space and continuous activities, the time range with the observation characters which can be regarded as Primacy Effect was analyzed in the aspects of continuity and saccade. First, with the case of alignment by time on three times of continuous observation, the perception attributes of subjects were shown to be very different among one another depending on which time range was applied for alignment. Second, the subjects with low average value of continuous observation times were found to be relatively stable in "ii~iii time ranges" and the time range of "0~5.10 seconds" was known to be the time range of relatively stable analysis for the characters of subjects' primacy effect to be analyzed. Third, the change of the amount of acquired information could be examined concretely through the analysis of observation attributes by time range, and the time range of "iii time range" showed more stable changing characters than other time ranges. Fourth, in the "iii time range" set up as a proper time range for the analysis of primacy effect had higher average value of 3.9 times of observation frequency compared with 6 times of continuous observation. As a grand average, 6 times(19.3) of average observation value was between 3 times(21.3) and 9 times(16.9), which enabled to set up 6 times of continuous observation as the number of observation times for stable analysis of primacy effect.

  • PDF

REAL-TIME 3D MODELING FOR ACCELERATED AND SAFER CONSTRUCTION USING EMERGING TECHNOLOGY

  • Jochen Teizer;Changwan Kim;Frederic Bosche;Carlos H. Caldas;Carl T. Haas
    • International conference on construction engineering and project management
    • /
    • 2005.10a
    • /
    • pp.539-543
    • /
    • 2005
  • The research presented in this paper enables real-time 3D modeling to help make construction processes ultimately faster, more predictable and safer. Initial research efforts used an emerging sensor technology and proved its usefulness in the acquisition of range information for the detection and efficient representation of static and moving objects. Based on the time-of-flight principle, the sensor acquires range and intensity information of each image pixel within the entire sensor's field-of-view in real-time with frequencies of up to 30 Hz. However, real-time working range data processing algorithms need to be developed to rapidly process range information into meaningful 3D computer models. This research ultimately focuses on the application of safer heavy equipment operation. The paper compares (a) a previous research effort in convex hull modeling using sparse range point clouds from a single laser beam range finder, to (b) high-frame rate update Flash LADAR (Laser Detection and Ranging) scanning for complete scene modeling. The presented research will demonstrate if the FlashLADAR technology can play an important role in real-time modeling of infrastructure assets in the near future.

  • PDF

DYNAMIC TIME WARPING FOR EFFICIENT RANGE QUERY

  • Long Chuyu Li;Jin Sungbo Seo;Ryu Keun Ho
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.294-297
    • /
    • 2005
  • Time series are comprehensively appeared and developed in many applications, ranging from science and technology to business and entertainrilent. Similarity search under time warping has attracted much interest between the time series in the large sequence databases. DTW (Dynamic Time Warping) is a robust distance measure and is superior to Euclidean distance for time series, allowing similarity matching although one of the sequences can elastic shift along the time axis. Nevertheless, it is more unfortunate that DTW has a quadratic time. Simultaneously the false dismissals are come forth since DTW distance does not satisfy the triangular inequality. In this paper, we propose an efficient range query algorithmbased on a new similarity search method under time warping. When our range query applies for this method, it can remove the significant non-qualify time series as early as possible before computing the accuracy DTW distance. Hence, it speeds up the calculation time and reduces the number of scanning the time series. Guaranteeing no false dismissals, the lower bounding function is advised that consistently underestimate the DTW distance and satisfy the triangular inequality. Through the experimental result, our range query algorithm outperforms the existing others.

  • PDF

The Study on the Analysis of the Rate of Information Acquisition and the Observation Time shown at the Observation of Interior Space (실내공간의 주시에 나타난 정보획득률과 주시시간 분석에 관한 연구)

  • Choi, Joo-Young;Kim, Joo-Hyun;Choi, Gae-Young;Lee, Jeong-Ho;Kim, Jong-Ha
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.6
    • /
    • pp.183-191
    • /
    • 2011
  • This study is to set up the appropriate range of observation time through contemplating the characteristics of observation time run for the information acquisition of space. The conclusions reached through this study are as the followings. First, this study could find out that even though the evaluation elements on the three types for image evaluation were the same, the information acquisitions were different as those types varied. On the other hand, the change of the average run-time by type for the information acquisition was found not to be big, in other words, even though the run-time was alike, the information acquisitions varied depending on the type. Second, he evaluation by language media showed the average value by element had the order of [shape>position>number>existence] and the range of their run-time was 94.6~102.9 seconds. The average rate of information acquisition shown at the visual media had the order of [composition>shape>material&color] and the range of run-time was 93.1~99.7 seconds. Third, the evaluation by language media showed that for male subjects the range of information acquisition rate was 39.1~91.4% and that of run-time 85.1~106.0 seconds and for female ones 46.0~94.6% and 96.3~112.3 seconds respectively. In case of the visual media, male subjects showed the range of information acquisition rate was 40.3-66.7% and the range of run-time 82.4~97.9 seconds and the female ones, 42.2~71.0% and 94.0~115.1 seconds respectively, through which we could see that at the evaluation by language media and visual media both the female's range of information acquisition and that of observation time were higher than the male's.

Electrical and Dielectric Properties of ZPCCY-Based Varistor Ceramics with Sintering Time (ZPCCY계 바리스터 세라믹스의 소결시간에 따른 전기적, 유전적 특성)

  • 남춘우;김향숙
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.11
    • /
    • pp.946-952
    • /
    • 2002
  • The electrical and dielectric characteristics of ZPCCY-based varistor ceramics were investigated in the sintering time range of 1∼3 h. Increasing sintering time deteriorated the nonlinearity, in which nonlinear exponent is decreased from 51.2 to 23.8 and leakage current is increased from 1.3 to 5.6 $\mu$A. As sintering time increases, the donor concentration was decreased in the range of (1.25∼l.73)$\times$10$\^$18/cm$\^$-3/ and the density of interface states is (3.64∼94.19)$\times$10$\^$12/cm$\^$-2/ with increasing sintering time. The increase in sintering time caused tan $\delta$ to increase in the range of 0.043 to 0.062 and relaxation time to increase in the range of 1.55 to 2.23 ㎲.

Real-time fractal coding implementation using the PC (PC를 이용한 실시간 프랙탈 부호화 구현)

  • 김재철;박종식
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.11
    • /
    • pp.2789-2800
    • /
    • 1996
  • Real time fractal coding for successive QCIF 144*176 luminance images has been implemented on a 50MHz IBM 486 personal computer. To satisfy the frame encoding speed and data compression ratio, following algorithms are adopted. In order to minimize encoding time, extension SAS being not searching of domain blocks is used. for reducing the bits per pixel, conventioal 4*4 range block is extended to 8*8 range block. and range block extension decrease quality of decoded image. For improvement quality of decoded image, the paper apply quad-tree partition mothod. In order to divide **8 range block, self-simiarity is compared 8*8 range block with spatial contractive transformed 8*8 domain block. According to self-simiarity, the block is partitioned and owing to block partition, increased encoding time is minimized. According to self-simiarity of 8*8 range block and spatial contractive transformed 8*8 domain block, number of fractal factor is varied. Simultaneously with minimizing the decrement of decoded image's quality, transmittion rate and encoding time is shorted. The results enable us to process the real-time fractal coding. For the claire test image, the average PSNR was 32.4dB, 0.12 bit rates and 33ms coding time per frame.

  • PDF

The Effect of a Submaximal Exercise Load on the Change in Blood Components. (최대하 운동부하가 혈액성분변화에 미치는 영향)

  • 이충훈
    • Korean Journal of Health Education and Promotion
    • /
    • v.14 no.1
    • /
    • pp.173-182
    • /
    • 1997
  • This study presents the results observed in the change in blood components of ten female students of “K” university's physical Education Department during submaximal exercise, relaxation and recovery periods. 1. After ecercise, the WBC value is higher than in relaxation time. Also within thirty minutes of the relaxation period it does not return to the normal range. 2. After exercise, the RBC value is higher than during relaxation time. Also in the recovery period, within 30 minutes it returns to the normal range. 3. After exercise. the RCT value is higher than during relaxation time. Also in the 30 minutes recovery period it returns to the normal range of relaxation. 4. After exercise, the Hb value is higher than during relaxation time. It rises slowly after exercise and returns to the relaxation range in the 30 minutes recovery period. 5. After exercise and in 10 minutes of the recovery period, the value of Glucose is lower than during relaxation time. It returns to the relaxation range in 30 minutes of the recovery period. 6. After exercise the value of protein is higher than during relaxation time. It returns to the relaxation range within ten to thirty minutes of the recovery period.

  • PDF

Evaluation of Local Velocity Gradient and Total Mass transfer Time at Various Rotating Velocity by Using Computational Fluid Dynamics (CFD를 이용한 패들교반속도에 따른 속도경사 및 총물질전달시간 산정)

  • Jun, Hang-Bae;Tian, Dong-Jie;Hong, Ki-Won;Han, Hong-Sig;Park, Byeong-Chang
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.2
    • /
    • pp.166-174
    • /
    • 2014
  • Velocity gradient, G, a measure of the average velocity gradient in the fluid has been applied for complete mixing of chemicals in mechanical mixing devices. G values were calculated by the power input transferred to fluid in turbulent and transient range. Chemical reactions occur so fast that total mass transfer time required for even distribution of the chemicals determine the overall reaction time. The total mass transfer time is composed of the time for complete mixing through the reactor and for diffusion of the chemicals into the eddy. Complete mixing time was calculated by CFD (computer fluid dynamics) and evaluated by tracer tests in 2 liter jars at different rotating speeds. Turbulent range, Reynolds number above 10,000 in regular 2 liter jars occurred at revolution speed above 100 rpm (revolution per minute), while laminar range occurred at revolution speed below 10 rpm. A typical range of rotating speed used in jar tests for water and wastewater treatment was between 10 and 300 rpm, which covered both transient and turbulent range. G values supplied from a commercial jar test apparatus showed big difference from those calculated with power number specially in turbulent range. Diffusion time through eddy decreased 1.5 power-law of rotating speed. Complete mixing time determined by pumping number decreased increases in rotating speed. Total mass transfer time, finally, decreases as rotating speed increases, and it becomes 1 sec at rotating speed of 1,000 rpm. Complete mixing times evaluated from tracer tests showed higher than those calculated by power number at higher rotating speed. Complete mixing times, however, calculated by CFD showed similar to those of experimentally evaluated ones.

Long-Range Dependence and 1/f Noise in a Wide Area Network Traffic (광역 네트워크 트래픽의 장거리 상관관계와 1/f 노이즈)

  • Lee, Chang-Yong
    • Journal of KIISE:Information Networking
    • /
    • v.37 no.1
    • /
    • pp.27-34
    • /
    • 2010
  • In this paper, we examine a long-range dependence in an active measurement of a network traffic which has been a well known characteristic from analyses of a passive network traffic measurement. To this end, we utilize RTT(Round Trip Time), which is a typical active measurement measured by PingER project, and perform a relevant analysis to a time series of both RTT and its volatilities. The RTT time series exhibits a long-range dependence or a 1/f noise. The volatilities, defined as a higher-order variation, follow a log-normal distribution. Furthermore, volatilities show a long-range dependence in relatively short time intervals, and a long-range dependence and/or 1/f noise in long time intervals. From this study, we find that the long-range dependence is a characteristic of not only a passive traffic measurement but also an active measurement of network traffic such as RTT. From these findings, we can infer that the long-range dependence is a characteristic of network traffic independent of a type of measurements. In particular, an active measurement exhibits a 1/f noise which cannot be usually found in a passive measurement.

A Computation Method for Time of Flight in the Anti-Aircraft Gun Fire Control System (대공화기 탄자비행시간 계산 기법)

  • Kim, Jaehun;Kim, Euiwhan;Yu, Sukjin;Kim, Sungho
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.4 no.11
    • /
    • pp.361-368
    • /
    • 2015
  • In AAGFCS the effective range is regarded as a range for the bullet's speed exceeding the speed of sound to damage the stationary target. Hence the real engagement range might be extended over the effective range for the approaching target since bullet's relative speed to the target increases depending on the approaching speed. However previous TOF equations have good computation accuracy within the effective range only, and they can not be used above that range due to their bad accuracy. We propose an accurate TOF computation method which can be used both within and above the effective range in real time. Some simulation results are shown to demonstrate usefulness of our algorithm for the 30mm projectile.