• Title/Summary/Keyword: Range Table

Search Result 475, Processing Time 0.029 seconds

Parametric study of a new tuned mass damper with pre-strained SMA helical springs for vibration reduction

  • Hongwang Lv;Bin Huang
    • Smart Structures and Systems
    • /
    • v.31 no.1
    • /
    • pp.89-100
    • /
    • 2023
  • This paper conducts a parametric study of a new tuned mass damper with pre-strained superelastic SMA helical springs (SMAS-TMD) on the vibration reduction effect. First, a force-displacement relation model of superelastic SMA helical spring is presented based on the multilinear constitutive model of SMA material, and the tension tests of the six SMA springs fabricated are implemented to validate the mechanical model. Then, a dynamic model of a single floor steel frame with the SMAS-TMD damper is set up to simulate the seismic responses of the frame, which are testified by the shaking table tests. The wire diameter, initial coil diameter, number of coils and pre-strain length of SMA springs are extracted to investigate their influences on the seismic response reduction of the frame. The numerical and experimental results show that, under different earthquakes, when the wire diameter, initial coil diameter and number of coils are set to the appropriate values so that the initial elastic stiffness of the SMA spring is between 0.37 and 0.58 times of classic TMD stiffness, the maximum reduction ratios of the proposed damper can reach 40% as the mass ratio is 2.34%. Meanwhile, when the pre-strain length of SMA spring is in a suitable range, the SMAS-TMD damper can also achieve very good vibration reduction performance. The vibration reduction performance of the SMAS-TMD damper is generally equal to or better than that of the classic optimal TMD, and the proposed damper effectively suppresses the detuning phenomena that often occurs in the classic TMD.

Health-related Community Facility Characteristics Typification and Relationship to Transaction Prices (건강 관련 커뮤니티 시설 특성 유형화 및 거래가격과의 관계)

  • Choi, Won-Joon
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.8
    • /
    • pp.358-366
    • /
    • 2022
  • Recently, 'Apartment community facilities' have emerged as the most optional factor in the apartment market, and their level is becoming very important. Therefore, this study derived each type through latent profile analysis centering on health-related community facilities in 126 domestic main apartment complexes, and as a result of the analysis, it was confirmed that it was divided into a Pilates group, GX and Yoga group, Golf and Table Tennis practice range group, and overall low group. Among the four groups, Pilates, GX, and yoga groups are more likely to belong to Gangnam, Seocho and Songpa compared to complexes with many golf and table tennis practice ranges, and at the same time, the transaction price is also the highest. Through these analysis results, it was suggested that changes in the preference for leisure activities should be reflected when constructing community facilities, and that health-related community facilities should be deeply considered in residential welfare policies in consideration of high preference for fitness facilities in youth housing.

Comparison Between Performance of Wireless MEMS Sensors and an ICP Sensor With Earthquake-Input Ground Motions (지진 입력 진동대를 이용한 무선 MEMS 센서와 ICP 가속도계의 성능 비교)

  • Mapungwana, S.T.;Lee, Jong-Ho;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.2
    • /
    • pp.63-72
    • /
    • 2019
  • Wireless sensors are more favorable in measuring structural response compared to conventional sensors in terms of them being easier to use with no issues with cables and them being considerably cheaper. Previous tests have been conducted to analyze the performance of MEMS (Micro Electro Mechanical Systems) sensor in sinusoidal excitation tests. This paper analyzes the performance of in-built MEMS sensors in devices by comparing with an ICP sensor as the reference. Earthquake input amplitude excitation in shaking table tests was done. Results show that MEMS sensors are more accurate in measuring higher input amplitude measurements which range from 100gal to 250gal than at lower input amplitudes which range from 10gal to 50gal. This confirms the results obtained in previous sinusoidal tests. It was also seen that natural frequency results have lower error values which range from 0% to 3.92% in comparison to the response spectra results. This also confirms that in-built MEMS sensors in mobile devices are good at estimating natural frequency of structures. In addition, it was also seen that earthquake input amplitudes with more frequency contents (Gyeongju) had considerably higher error values than Pohang excitation tests which has less frequency contents.

Clinical Comparison of $Henoch-Sch\"{o}nlein$ Purpura Nephritis in Children and Adults (소아와 성인 $Henoch-Sch\"{o}nlein$ Purpura(HSP) 신염의 임상적 비교)

  • Kim Ki-Eun;Shin Youn-Ho;Shin Jae-Il;Park Jee-Min;Jeong Hyeon-Joo;Lee Jae-Seung
    • Childhood Kidney Diseases
    • /
    • v.7 no.2
    • /
    • pp.157-165
    • /
    • 2003
  • Purpose : $Henoch-Sch\"{o}nlein$ purpura(HSP) is a systemic vasculitis that involves multiple organs, especially the kidney, which is the most important organ in determining the prognosis of the disease. The morbidity of HSP nephritis in adults is low and there have been little research done on its clinical course so far. Therefore, we have compared the clinical course of HSP nephritis in children and adults in Korea. Methods : We retrospectively analyzed 81 cases of HSP nephritis in children younger than 15 years of age, and 25 cases of adults older than 15 years of age who were admitted to Yonsei University Medical College Severance Hospital from Jan. 1986 to May 2003. Results : The male to female ratio was 1.5 : 1 in children and 1.3 : 1 in adults. The incidence of HSP nephritis for both age groups was found to be increased during the autumn and winter. Infection was the predisposing factor in 39 cases(48.1%) of children, 16 cases(64.0%) of adults, and drugs were the predisposing factor in 8 cases(9.9%) of children and 4 cases (16.0%) of adults. All patients initially presented with microscopic hematuria. Thirteen cases (16.0%) of children and 7 cases(28.0%) of adults initially showed proteinuria of nephrotic range. Thirty four cases(42.0%) of children and 4 cases(16.0%) of adults showed normal urinalysis after treatment. Asymptomatic urinary abnormalities were found in 41 cases(50.6%) of children and 18 cases(72.0%) of adults. Complications such as nephrotic syndrome and hypertension were found in 3 cases(3.7%) of children and 2 cases(8.0%) of adults. Three children(3.7%) and 1(4.0%) adult required dialysis or renal transplantation. Follow-up renal biopsies were performed on 21 children, of whom 10 cases(47.6%) did not show any histologic change, 9 cases(42.9%) showed low grade changes, and 2 cases(9.5%) showed high grade changes. Prognosis was gloomy when proteinuria of nephrotic range and high grade of abnormal histology were present at diagnosis, and there was no significant difference between the two groups(P<0.05) Conclusion : This study showed that there was no difference in terms of the clinical features and courses between the children and adults with HSP nephritis. Proteinuria of nephrotic range and the severity of abnormal histologic changes at diagnosis were found to be associated with a bad prognosis, therefore we recommend that patients with these features require long term follow-up and management.

  • PDF

MORPHOMETRICS OF ALVEOLAR PROCESS AND ANATOMICAL STRUCTURES AROUND INFERIOR MAXILLARY SINUS FOR MAXILLARY IMPLANTATION (임플랜트 시술을 위한 치조돌기와 상악동 주변 구조물의 형태계측적 연구)

  • Park, Ju-Jin;Lee, Young-Soo;Paik, Doo-Jin;Park, Won-Hee;Yoo, Dong-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.228-239
    • /
    • 2007
  • Statement of problem: Following tooth loss, the edentulous alveolar process of maxilla is affected by irreversible reabsorption process, with progressive sinus pneumatization leads to leaving inadquate bone height for placement of endosseous implants. Grafting the floor of maxillary sinus by sinus lifting surgery and augmentation of autologous bone or alternative bone material is a method of attaining sufficient bone height for maxillary implants placement and has proven to be a highty successful. Purpose: This study was undertaken to clarify the morphometric characteristics of inferior maxillary sinus and alveolar process for installation of implants. Material and method: Nineteen skulls (37 sinuses, 10M / 9F) obtained from the collection of the department of anatomy and cell biology of Hanyang medical school were studied. The mean age of the deceased was 69.9 years (range 44 to 88 years). The distance between alveolar border and inferior sinus margin at each tooth, the height of alveolar process and the thickness of cortical bone of the outer and inner table of alveolar process and the inferior wall of maxillary sinus were measured. Results and Conclusion: 1. The septum of inferior maxillary sinus were observe 28 sides (76.%) and located at the third molar (52.6%) and the second molar (26.3%). The deepest points of inferior border of maxillary sinus were located the first or second molar. The distance between alveolar margin and the deepest point of inferior maxillary sinus is $9.7{\pm}4.9mm$. 2. The length of the outer table of alveolar process were $4.9\sim28.2mm$ and the shortest point was between the first and the second molors. The thickness of them were $0.9\sim3.2mm$. The length of the inner table of alveolar process were $7.4\sim25.8mm$ and the shortest point was between the first and the second molars. The thickness of the were $0.9\sim4.6mm$. The results of this study are useful anatomical data for installing of maxillary implants.

A Study On Context Sensitive Highway Design Based On Improved Operating Speed Prediction Methods in National Roads (환경 친화적 도로 설계를 위한 기초 연구 (노선대 지형 및 지역 요소를 고려한 일반국도 주행속도 예측 모형))

  • Kim, Sang-Youp;Choi, Jai-Sung
    • Journal of Korean Society of Transportation
    • /
    • v.23 no.7 s.85
    • /
    • pp.17-33
    • /
    • 2005
  • Highway design speed is a very important design element which determines highway design level. When determining highway design speed, one would estimate it utilizing the most likelihood of design speed and vehicle operating speed relationship. Existing operating speed prediction models only include highway geometric characteristics and their impacts on speed, which usually can not consider the impact of highway design speed on surrounding roadway environment and land use pattern. If this happens, excessive highway construction cost and huge environmental impact can occur. In this research project, a new vehicle operating speed prediction model was developed which can reflect the effect of surrounding roadway environment into vehicle speed prediction. The followings are the research findings : Firstly, highway terrain types and land use pattern on national roads were classified and integrated into drivers' visual recognition pattern. This was performed using a data management software. Secondly, the developed highway terrain types and land use pattern were related to vehicle speeds and it was found that there were significant statistical differences among vehicle speed for each different terrain and land use pattern. Thirdly. the General Linear Model analysis was employed to analyze the effects of highway geometric features, terrain types, and land use patterns. For two-lane highway and four-lane highway tested in this research project, it was found that R squares were 0.67 and 0.85, respectively. Additionally an optimal highway design speed range table, based on this research project. was proposed for practical use. This table can be reliably used on South Korean national road design, but discretion is required for applying this table to other types of highways including provincial roads and municipal roads.

Kinematic and Ground Reaction Force Analyses of the Forehand Counter Drive in Table Tennis (탁구 포핸드 카운터 드라이브 동작의 운동학적 변인 및 지면 반력 분석)

  • Lee, Young-Sik;Lee, Chong-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.2
    • /
    • pp.155-165
    • /
    • 2010
  • The purpose of this study was to analyze kinematic quantitative factors required of a forehand counter drive in table tennis through 3-D analysis. Four national table tennis players participated in this study. The mean of elapsed time for total drive motion was $1.009{\pm}0.23\;s$. At the phase of impact B1 was the fastest as 0.075 s. This may affect efficiency in the initial velocity and spin of the ball by making a powerful counter drive. The pattern of center of mass showed that it moved back and returned to where it was then moved forward. At the back swing, lower stance made wide base of support and a stronger and safer stance. It may help increasing the ball spin. Angle of the elbow was extended up to $110.75{\pm}1.25^{\circ}$ at the back swing and the angle decreased by $93.75{\pm}3.51^{\circ}$ at impact. Decreased rotation range of swinging arm increased linear velocity of racket-head and impulse on the ball. Eventually it led more spin to the ball and maximized the ball speed. Angle of knee joint decreased from ready position to back swing, then increased from the moment of the impact and decreased at the follow thorough. The velocity of racket-head was the fastest at impact of phase 2. Horizontal velocity was $7796.5{\pm}362\;mm/s$ and vertical velocity was $4589.4{\pm}298.4\;mm/s$ at the moment. It may help increase the speed and spin of the ball in a moment. The means of each ground reaction force result showed maximum at the back swing(E2) except A2. Vertical ground reaction force means suggest that all males and females showed maximum vertical power(E2), The maximum power of means was $499.7{\pm}38.8\;N$ for male players and $519.5{\pm}136.7\;N$ for female players.

Ergonomic Design of Medic Work Table (MWT) for Medical Technologist

  • Choi, Kyeong-Hee;Lee, Sung-Yong;Lee, Jun-Hyub;Kong, Yong-Ku
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.595-609
    • /
    • 2016
  • Objective: The purpose of this study was to develop and validate the guidelines for Medic Work Table (MWT) based on the anthropometric data of medical technologists. Background: Users' anthropometric data such as sitting height, sitting elbow height, knee height, and so on are significant factors for designing comfortable and useful furniture. Thus, many guidelines for different types of desks and chairs based on the users' anthropometric data have been suggested to many researchers. However, few researches have been conducted to provide design guidelines for MWT for blood collecting task. Medical technologists often use their upper extremities to perform blood collecting task with high repetitions. These repeated motions could be a critical factor in the prevalence rate of Work-related Musculoskeletal Disorders (WMSDs). Therefore, a study on ergonomic design of MWT would be essential in preventing the WMSDs and improving the quality of the working environment of medical technologists. Method: This study suggested design guidelines for ergonomic MWT by focusing on the heights of the upper side and underside, depths of the inside and outside, and width of MWT through anthropometric studies and literature reviews. Afterwards, a new MWT was made using the suggested design guidelines for this study. Five healthy medical technologists participated to evaluate the original MWT and new MWT. All participants took part in the range of motion (ROM) test, electromyography (EMG) muscle activity test, and usability test to validate the suggested guidelines in this study. EMG signals of related muscles (Flexor Carpi Ulnaris, Extensor Carpi Ulnaris, Deltoid Anterior, and Biceps Branchii) were recorded through the surface electromyography system from both the original MWT and the new MWT. The ROM test of the shoulder and elbow flexion was also assessed using motion sensors. Results: The newly designed MWT showed decreased ROMs of the shoulder and elbow up to 22% and 18% compared to the original MWT. The muscle activities in the new MWT also showed a decrease of 13% in Anterior Deltoid, 6% in Biceps Brachii, 5% in Flexor Carpi Ulnaris, and 8% in Extensor Carpi Ulnaris muscle groups, compared to the original MWT. In the usability test, the satisfaction score of the new MWT was also 56.1% higher than that of the original MWT. Conclusion: This study suggested guidelines for designing MWT and validating the guidelines through qualitative and quantitative analyses. The results of motion analysis, muscle activity, and usability tests demonstrated that the newly designed MWT may lead to less physical stress, less awkward posture, and better physical user interface. Application: The recommended guidelines of the MWT would be helpful information for designing an ergonomic MWT that reduces physical loads and improves the performance of many medical technologists.

Robust DNA Watermarking based on Coding DNA Sequence (부호 영역 DNA 시퀀스 기반 강인한 DNA 워터마킹)

  • Lee, Suk-Hwan;Kwon, Seong-Geun;Kwon, Ki-Ryong
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.49 no.2
    • /
    • pp.123-133
    • /
    • 2012
  • This paper discuss about DNA watermarking using coding DNA sequence (CDS) for the authentication, the privacy protection, or the prevention of illegal copy and mutation of DNA sequence and propose a DNA watermarking scheme with the mutation robustness and the animo acid preservation. The proposed scheme selects a number of codons at the regular singularity in coding regions for the embedding target and embeds the watermark for watermarked codons and original codons to be transcribed to the same amino acids. DNA base sequence is the string of 4 characters, {A,G,C,T} ({A,G,C,U} in RNA). We design the codon coding table suitable to watermarking signal processing and transform the codon sequence to integer numerical sequence by this table and re-transform this sequence to floating numerical sequence of circular angle. A codon consists of a consecutive of three bases and 64 codons are transcribed to one from 20 amino acids. We substitute the angle of selected codon to one among the angle range with the same animo acid, which is determined by the watermark bit and the angle difference of adjacent codons. From in silico experiment by using HEXA and ANG sequences, we verified that the proposed scheme is more robust to silent and missense mutations than the conventional scheme and preserve the amino acids of the watermarked codons.

Changes in the Comfort and Image Quality of the Patient According to the Application of Air Mattresses in the Computed Tomography Table (전산화단층촬영 테이블의 에어 매트리스 적용에 따른 환자의 편안함과 화질 변화)

  • Young-Hee, Lee;Yong-Ki, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.889-896
    • /
    • 2022
  • This study attempted to evaluate the usefulness of the air mattress by analyzing the subjective comfort of the patient due to the application of the air mattress to the table of computed tomography through a questionnaire and analyzing the change in image quality through quantitative and qualitative evaluation of the patient's clinical images. The subjects who participated in the study were 221 men and 229 women, and the age range was from 18 to 86. To evaluate the change in image quality, a total of 150 patients, 50 patients per group, were selected for quantitative evaluation, and 20 patients per group, a total of 60 patients were selected for qualitative evaluation. As a result of this study, the subjective comfort of patients increased due to air mattresses, and there was no difference in image quality as a result of quantitative and qualitative evaluation of clinical images. From the above results, it is believed that the air mattress can be usefully applied in a way that can increase the subjective comfort of the patient without any harm to the diagnostic image.