• Title/Summary/Keyword: Range Table

Search Result 474, Processing Time 0.032 seconds

Stereotype for Control-display Relationship of Four-burner Range for Korean

  • Kee, Do-Hyung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.3
    • /
    • pp.389-394
    • /
    • 2011
  • The aims of this study are to investigate the Korean population stereotype for control-display linkage of four-burner gas-range, and to compare the results of this study with those of the existing studies. The investigation used a paper-pencil test using questionnaire with a sign code system for eliminating suggestive effect of sequential code. Two hundreds and eighty subjects participated in the investigation, among whom 254 subjects effectively responded to question for the gas-range stereotype. The results showed that type III(refer to Table 2) was chosen more frequently than type II, IV and V(p<0.01). The gender is not significant on responding rate for the type of control-burner linkage(p>0.92), while the age and occupation have significant effect on the rate(p<0.01). Based on this study, it appears that type III represents the population stereotype of control-burner arrangement for Korean. The stereotype was the same as that of Chinese, but different from that of American(type II or IV). The findings of this study would be helpful as basic data for ergonomically designing gas-range or similar products.

A study on machining conditions on surface roughness in EPS End-milling (EPS 엔드밀 가공 시 표면 거칠기에 미치는 가공조건에 관한 연구)

  • Seo, Keum-Hee;Son, Min-Kyu;Yoon, Gil-Sang;Ko, Young-Bae
    • Design & Manufacturing
    • /
    • v.11 no.2
    • /
    • pp.46-50
    • /
    • 2017
  • EPS used in lost foam casting elastic modulus is extremely low. So it is necessary to derive machining conditions for effective cutting. Therefore this study were analyzed end-milling machining conditions to affecting the surface roughness of EPS foam. The machining conditions were set to depth, feed, and RPM at 3-level. And 18experimental conditions were derived using mixed orthogonal array. The most important condition for surface roughness is RPM. In addition, RPM machining condition range test that can realize surface roughness less than $10{\mu}m$ was performed. he range of RPM conditions is more than 15,000. However the range of RPM conditions is a condition that is difficult to use in actual field. In the future variance analysis and experiments are needed to derive the range of machining conditions available.

Maximum A Posteriori Estimation-based Adaptive Search Range Decision for Accelerating HEVC Motion Estimation on GPU

  • Oh, Seoung-Jun;Lee, Dongkyu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.9
    • /
    • pp.4587-4605
    • /
    • 2019
  • High Efficiency Video Coding (HEVC) suffers from high computational complexity due to its quad-tree structure in motion estimation (ME). This paper exposes an adaptive search range decision algorithm for accelerating HEVC integer-pel ME on GPU which estimates the optimal search range (SR) using a MAP (Maximum A Posteriori) estimator. There are three main contributions; First, we define the motion feature as the standard deviation of motion vector difference values in a CTU. Second, a MAP estimator is proposed, which theoretically estimates the motion feature of the current CTU using the motion feature of a temporally adjacent CTU and its SR without any data dependency. Thus, the SR for the current CTU is parallelly determined. Finally, the values of the prior distribution and the likelihood for each discretized motion feature are computed in advance and stored at a look-up table to further save the computational complexity. Experimental results show in conventional HEVC test sequences that the proposed algorithm can achieves high average time reductions without any subjective quality loss as well as with little BD-bitrate increase.

The Accuracy of the Table Movement During a Whole Body Scan (전신 영상 검사 시행 시 테이블 이동속도의 정확성에 관한 연구)

  • Lee, Ju-Young;Jung, Woo-Young;Jung, Eun-Mi;Dong, Kyung-Rae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.86-91
    • /
    • 2009
  • Purpose: The whole body scan in Nuclear Medicine is a widely accepted examination and procedure. Especially, it is mainly used in bone, I-131, MIBI, and HMPAO WBC scans. The diverse uses of the whole body scan range from the HMPAO WBC scan with a speed of 13cm/min, to a whole body bone scan using the Onco. Flash technique with a speed of 30cm/min. The accuracy of table movement has a strong correlation with the image quality, and inaccuracy of speed could negatively affect the image quality. The purpose of this study is to evaluate the accuracy of the table movement while considering the influence of the age of the equipment and the variability in the weight of the patients. Material and Methods: The study was conducted using two of Seoul Asan Medical Center's SIEMENS gamma cameras which are commonly used in our whole body study. The first one is the oldest gamma camera, an ECAM plus (installed in 2000), and the last is brand new one, a SYMBIA T2 (installed in 2008). Three trials were conducted with the tables moving at a different speed each time; 10, 15 and 30 cm/min. The tables' speeds were measured by checking how long it took for the table to move 10cm, and this was repeated every 10cm until the table reached 100 cm. With an average body weight of the patients of about 60~70 kg, the table speed was measured with weights of 0 kg, 66 kg and 110 kg placed on the table, then compared among conditions. Results: The coefficient of variance (CV) of the ECAM plus showed 1.23, 1.42, 2.02 respectively when the table movement speeds were set at 10, 15, and 30 centimeters per minute. Under the same conditions, the SYMBIA T2 showed 1.23, 1.83 and 2.28 respectively. As table movement speed more, the variance of CV as the speed increases. When the patient body weight was set to 0, 66 and 110kg, the CV values of both cameras showed 0.96, 1.45, 2.08 (0 Kg), 1.32, 1.72, 2.27 (66 Kg) and 1.37, 1.73, 2.14 (110 Kg). There was no significant difference (p>0.05) in 95 percent of confidence intervals and measured CV values were acceptable. However, the CV value of the SYMBIA T2 was relatively larger than the ECAM plus. Conclusion: The scan speed of the whole body scan is predetermined based on which examination is being performed. It is possible for the accuracy of the speed to be affected, such as the age of the equipment, the state of the bearings or the weight of a patient. These factors can have a negative impact on the diagnostic consistency and the image quality. Therefore, periodic quality control should be needed on the gamma cameras currently being used, focusing on the table movement speed in order to maintain accuracy and reproducibility.

  • PDF

Development of Stand Yield Table Based on Current Growth Characteristics of Chamaecyparis obtusa Stands (현실임분 생장특성에 의한 편백 임분수확표 개발)

  • Jung, Su Young;Lee, Kwang Soo;Lee, Ho Sang;Ji Bae, Eun;Park, Jun Hyung;Ko, Chi-Ung
    • Journal of Korean Society of Forest Science
    • /
    • v.109 no.4
    • /
    • pp.477-483
    • /
    • 2020
  • We constructed a stand yield table for Chamaecyparis obtusa based on data from an actual forest. The previous stand yield table had a number of disadvantages because it was based on actual forest information. In the present study we used data from more than 200 sampling plots in a stand of Chamaecyparis obtusa. The analysis included theestimation, recovery and prediction of the distribution of values for diameter at breast height (DBH), and the result is a valuable process for the preparation ofstand yield tables. The DBH distribution model uses a Weibull function, and the site index (base age: 30 years), the standard for assessing forest productivity, was derived using the Chapman-Richards formula. Several estimation formulas for the preparation of the stand yield table were considered for the fitness index, and the optimal formula was chosen. The analysis shows that the site index is in the range of 10 to 18 in the Chamaecyparis obtusa stand. The estimated stand volume of each sample plot was found to have an accuracy of 62%. According to the residuals analysis, the stands showed even distribution around zero, which indicates that the results are useful in the field. Comparing the table constructed in this study to the existing stand yield table, we found that our table yielded comparatively higher values for growth. This is probably because the existing analysis data used a small amount of research data that did not properly reflect. We hope that the stand yield table of Chamaecyparis obtusa, a representative species of southern regions, will be widely used for forest management. As these forests stabilize and growth progresses, we plan to construct an additional yield table applicable to the production of developed stands.

Practical Ultraprecision Positioning of a Ball Screw Mechanism

  • Sato, Kaiji;Maeda, Guilherme Jorge
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.2
    • /
    • pp.44-49
    • /
    • 2008
  • This paper describes the problem of ultraprecision positioning with a ball screw mechanism in the microdynamic range, along with its solution. We compared the characteristics of two ball screw mechanisms with different table masses. The experimental results showed that the vibration resulting from the low stiffness of the ball screw degraded the positioning performance in the microdynamic range for the heavyweight mechanism. The proposed nominal characteristic trajectory following (NCTF) controller was designed for ultra precision positioning of the ball screw mechanism. The basic NCTF control system achieved ultra precision positioning performance with the lightweight mechanism, but not with the heavyweight mechanism. A conditional notch filter was added to the NCTF controller to overcome this problem. Despite the differences in payload and friction, both mechanisms then showed similar positioning performance, demonstrating the high robustness and effectiveness of the improved NCTF controller with the conditional notch filter. The experimental results demonstrated that the improved NCTF control system with the conditional notch filter achieved ultra precision positioning with a positioning accuracy of better than 10 nm, independent of the reference step input height.

A Non-contact Shape Measuring System Using an Artificial Neural Network

  • Jeong, Woo-tae;Lee, Myung-Chan;Koh, Duck-joon;Cho, Hyung-suck
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.399-404
    • /
    • 1996
  • We developed a non-contact shape measuring device using computer image processing technology. We present a method of calibrating a CCD video camera and a laser range finder which is the most important step toward making an accurate shape measuring system. An artificial neural network is used for the calibration. Our measurement system is composed of a semiconductor laser. a CCD video camera, a personal computer, and a linear motion table. We think that the developed system could be used for measuring the change in shape of the spent nuclear fuel rod before and after irradiation which is one of the most important tasks for developing a better nuclear fuel. A radiation shield is suggested for the possible utilization of the range finder in radioactive environment.

  • PDF

Distributions of Hydrogeological Variables and Flow Field on GIS Digital Map (GIS 수치지도를 이용한 수리지질학적 변수와 지하수 유동의 분포)

  • Lee, Cheo K.
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.2 no.2
    • /
    • pp.45-58
    • /
    • 1999
  • Digital map is utilized for an effective display of the distributions of the hydrogeological variables such as water table height(hydraulic head) and log-transmissivity(lnT) in north Pohang, KyungBug. Specifically the geostatistical method kriging is used to construct the distributions in an unconfined aquifer from a finite set of measured data. The experimental variograms for both the head and lnT suggest spherical models with nugget of 0 and range of 6km. The kriged results by using these variograms show that the head decreases primarily from the west to the east with a large peak in the north-western part and lnT is at the maximum level in the central part with outwardly decreasing trend. The constructed delineation is also used to calculate the flow field in the region. Finite differences with second order consistency are used to calculate the fluxes in the east(x) and north(y) across a vertical cross-section of unit width and height equal to the thickness of the wet zone in the aquifer. It is demonstrated that the flow is dominantly in the east with diverging trend on the eastern hillside of the water table peak. A few convergent spots also appear.

  • PDF

A Study on clinical Considerations caused by inevitably Extended SSD for Electron beam therapy (확장된 SSD에 기인한 Electron beam의 Output 및 특성 변화에 관한 연구)

  • Lee, Jeong-U;Kim, Jeong-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.29-35
    • /
    • 1996
  • We are often faced with the clinical situations that is inevitably extended SSD for electron beam therapy due to anatomical restriction or applicator structure. But there are some difficulties in accurately predicting output and properties. In electron beam treatment , unlike photon beam the decrease in output for extended SSD does not follow inverse-square law accurately because of a loss of side scatter equilibrium, which is particularly significant for small cone size and low energies. The purpose of our study is to analyze the output in changing with the energy, cone size, air gap beyond the standard SSD and to compare inverse-square law factor derived from calculated effective SSD, mominal SSD with measured output factor. In addition, we have analyzed the change of PDD for several cones with different SSDs which range from 100cm to 120cm with 5cm step and with different energies(6MeV, 9MeV, 12MeV, 16MeV, 20MeV). In accordance with our study, an extended SSD produces a significant change in beam output, negligible change in depth dose which range from 100cm to 120cm SSDs. In order to deliver the more accurate dose to the neoplastic tissue, first of all we recommend inverse-square law using the table of effective SSDs with cone sizes and energies respectively or simply to create a table of extended SSD air gap correction factor. The second we need to have an insight into some change of dose distribution including PPD, penumbra caused by extended SSD for electron beam therapy.

  • PDF

Hydrological Studies on the Comparison and the Derivation of Unit Hydrography in the small River Systems. (소하천수계의 단위유량도 유도 및 비교에 관한 수문학적 고찰)

  • 이순혁
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.20 no.3
    • /
    • pp.4739-4749
    • /
    • 1978
  • This studies were conducted to derive synthetic unitgraphs and triangular unitgraphs correlated with watershed characteristics which can be used to the estimation and control of flood for the rational development of Agricultural water resources. Derived Synthetic unitgraphs and Triangular unitgraphs can be applied to the ungaged watersheds were compared with average unitgraphs by observed data. Seven small watersheds were selected as studying basins Han, Geum, Nakdong, Yeongsan and Inchon river system. The results summarized for these studies are as follows: 1. Average unitgraphs by observed data and dimensionless unitgraphs for synthesis were derived for all river systems. 2. Peak discharge per unit area of the unitgraph, qp, was derived as qp=10-0.389-0.0424Lg with a high significance. 3. Formulas for the base width of unitgraph of 50 and 75 percent for peak flow for each water systems was adopted as Table 5. 4. The base length of the unitgraph, Tb, in hours in connection with time to peak, Tp, in hours was expressed as Tb =4.3Tp. 5. Peak discharge, Qp, were obtained as Table 6 by the Triangular form to all subwatersheds. 6. Relative errors in the peak discharge of the synthetic unitgraphs showed to be 7.3 percent to the peak of observed average unitgraphs except errors of peak discharge for Yeongsan river system. This indicates that Synthetic unitgraphs for the small watersheds of Han, Geum, Nakdong and Inchon river systems can be applied to the ungaged watersheds. On the other hand, It was confirmed that the accuracy of Instantaneous Unit Hydrograph with only 1.6 percent as relative errors was approaching more closely to the observed average unitgraph than that of synthetic unitgraph with relative errors. 23.9 percent for Yeongsan river system. 7. Errors in the peak discharge of the triangular unitgraph to the observed average unitgraph showed to be 0.6 percent to 7.5 percent which can be regarded as a high precision within the range of 200 to 500$\textrm{km}^2$ in area. On the contrary, application of triangular unitgraph within the range of 200$\textrm{km}^2$ in area has defined as a unsuitable method because of high relative errors, 26.4 percent to 61.6 percent.

  • PDF