• 제목/요약/키워드: Range Safety

검색결과 3,020건 처리시간 0.039초

곡선부 통과열차의 레일 경좌 변화에 따른 주행안전성 해석 (A Running Safety Analysis of Railway Vehicle passing through Curve According to Rail Inclination Change)

  • 손명선;엄범규;강부병;이희성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1922-1928
    • /
    • 2011
  • The rail inclination produces a wider bearing area between the wheel and the rail by moving the wheel rail contact area away from the gauge towards the centre of the railhead, thus improving the wear pattern of the railhead and wheel treads. It is essential to keep the rail inclination within the allowable range to ensure optimum track geometry. Neglecting the rail inclination geometrical parameters in a track quality evaluation can cause safety of railway vehicle and serviceability problems. In this paper, we examined the effect of the rail inclination in general geometry state of the railway track using VI-Rail and analyzed running safety when the railway vehicle passing through curves depending on change of the rail inclination and running speed.

  • PDF

UNIFAC 그룹 기여 모델에 의한 n-Octnae+n-Decane 계와 n-Octane+n-Dodecane 계의 인화점 계산 (Flash Point Calculation for n-Octane+n-Decane and n-Octane+n-Dodecane by UNIFAC Group Contribution Model)

  • 하동명;이성진
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.86-91
    • /
    • 2015
  • The flash point is used to categorize inflammable liquids according to their relative flammability. Such a categorization is important for the safe handling, storage, and transportation of inflammable liquids. The flash point temperature of two binary liquid mixtures(n-octane+n-decane and n-octane+n-dodecane) has been measured for the entire concentration range using Seta-flash closed cup tester based on the ASTM D3278 method. The closed cup flash point temperature was estimated using the UNIFAC(Universal Functional Activity Coefficient) group contribution model. The experimentally derived flash point was also compared with the predicted flash point from the UNIFAC model. The UNIFAC model is able to estimate the flash point fairly well for n-octane+n-decane mixture and n-octane+n-dodecane mixture.

Lactobacillus plantarum LMG 7945가 생산하는 bacteriocin의 항균력과 그 특성 (Antibacterial Activity and Characteristics of Bacteriocin Produced by Lactobacillus plantarum LMG 7945)

  • 김상현;이명숙;장동석
    • 한국식품위생안전성학회지
    • /
    • 제10권2호
    • /
    • pp.65-71
    • /
    • 1995
  • Bacteriocins from lactic acid bacteria have attracted much attention in recent years because of their useful worth in increasing safety and extending shelf life of foods. These substances show an inhibitory effect against some food spoilage bacteria and food-borne pathogens. The inhibitory effect fo the bacteriocin produces by lactic acid bacteria against Listeria monocytogenes(L. monocytogenes) was examined in this study. The culture supernatants of 5 kinds of bacteria among the 10 kinds of testes lactic acid bacteria had the inhibitory activity against Listeria sp., various Gram positive and Gram negative bacteria. Bacteriocin produced by Lactobacillus plantarum(Lact. plantarum) LMG 7945 was the most active toward L. monocytogenes. Bacteriocin production of the Lact. plantarum LMG 7945 cultured on MRS broth was increased late logarithmic phase over early stationary phase. This bacteriocin was stable at heat treatment and acidic pH relatively; The activity was retained after heating at 121$^{\circ}C$ for 15min and was active in the pH range of 2~4 but was lost above pH 5.

  • PDF

The Development of a Programmable Single-Phase AC Power Source with a Linear Power Amplifier

  • Jeon, Jeong-Chay;Jeon, Hyun-Jae;Yoo, Jae-Geun;Son, Jae-Hyun
    • 조명전기설비학회논문지
    • /
    • 제21권9호
    • /
    • pp.39-46
    • /
    • 2007
  • This paper presents a programmable single-phase ac power source that provides a sinusoidal output voltage with an adjustable output amplitude and frequency over a wide range as well as an arbitrary waveform. The ac power source under consideration have a linear power amplifier. The desired output values can be programmed with a personal computer. The power source operates at 220[V]/60[Hz] mains and the output voltage is isolated from the input circuit. The system consists mainly of a power converter to generate and amplify the waveform signal, a controller to control the desired output signal and measure the output parameters, and a control program to set the desired output and display the values. The prototype ac power source was constructed and tested with the results demonstrating a good performance.

30AF 차단기 순시 Trip 동작 특성분석을 통한 저압차단기의 안전성 개선방안 (A Safety Improvement of Low Voltage Circuit-breakers through Analysis of Instantaneous Trip Characteristics of 30AF Circuit-Breakers)

  • 김주철;임정균;이상중
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.78-83
    • /
    • 2010
  • The domestic 30AFs that are currently being produced show many problems due to different instantaneous trip characteristics in case of short-circuit. The troubles may cause explosion by excessive short-circuit capacities and arc emission, which results in a wide range of blackout. The function and safety of the low voltage circuit breakers installed before the end load are very important. This paper presents an idea on the safety improvement of the low voltage circuit-breakers through the analysis of instantaneous trip characteristics of domestic 30AF circuit-breakers.

정압관리소의 지전계측기 설치를 위한 지반특성 분석 (Ground Response Analysis of the Cmpressor Station for Installation of Seismic Instrument)

  • 권기준;김용길
    • 한국안전학회지
    • /
    • 제17권1호
    • /
    • pp.79-86
    • /
    • 2002
  • In the case of earthquake, it is necessary to install earthquake instruments and to measure the ground motions for stable gas supply and restoration in case of supply suspension. Because each point in the site of the gas facilities has different characteristics of ground motion, it is recommended to measure at the point where the ground motion is representative. In this paper, ground motion analysis and noise pattern analysis are carried out to select suitable point for the installation of earthquake instruments and to set of dynamic range of sensors.

A Numerical Study on Methane-Air Counterflow Diffusion Flames Part 2. Global Strain Rate

  • Park, Woe Chul
    • International Journal of Safety
    • /
    • 제2권1호
    • /
    • pp.12-16
    • /
    • 2003
  • In Part 1, the flame structure of the counterflow nonpremixed flames computed by using Fire Dynamics Simulator was compared with that of OPPDIF for different concentrations of methane in the fuel stream. In this study, comparisons were made for the global strain rate that is an important parameter for diffusion flames for further evaluation of FDS. At each of the three fuel concentrations, $20% CH_4+ 80% N_2, 50% CH_4 + 50% N_2, 90% CH_4 + 10% N_2$ in the fuel stream, the temperature and axial velocity profiles were investigated for the global strain rate in the range from 20 to $100s^{-1}$. Changes in flame thickness and radius were also compared with OPPDIF. There was good agreement in the temperature and axial velocity profiles between the axisymmetric simulations and the one-dimensional computations except for the regions where the flame temperature reach its peak and the axial velocity rapidly changes. The simulations of the axisymmetric flames with FDS showed that the flame thickness decreases and the flame radius increases with increasing global strain rate.

A Numerical Study on Methane-Air Counterflow Diffusion Flames Part 1. Concentration of Fuel

  • Park, Woe-Chul
    • International Journal of Safety
    • /
    • 제2권1호
    • /
    • pp.7-11
    • /
    • 2003
  • Structure of the counterflow nonpremixed flames were investigated by using Fire Dynamics Simulator(FDS) and OPPDIF to evaluate FDS for simulations of the diffusion flame. FDS, employed a mixture fraction formulation, were applied to the diluted axisymmetric methane-air nonpremixed counterflow flames. Fuel concentration in the mixture of methane and nitrogen was considered as a numerical parameter in the range from 20% to 100% increasing by 10% by volume at the global strain rates of $a_g = 20S^{-l} and 80S^{-1}$ respectively. In all the computations, the gravity was set to zero since OPPDIF is not able to compute the buoyancy effects. It was shown by the axisymmetric simulation of the flames with FDS that increasing fuel concentration increases the flame thickness and decreases the flame radius. The centerline temperature and axial velocity, and the peek flame temperature showed good agreement between the both methods.

닻 운용 시뮬레이션에 의한 선체운동 제어에 관한 연구 (A Study on the Control of Ship Maneuvering by the Simulation of Anchor Dredging)

  • 윤순동
    • 해양환경안전학회지
    • /
    • 제8권2호
    • /
    • pp.9-15
    • /
    • 2002
  • Ship operators use anchor dredging for the collision avoidance or safety of ship handling in a harbour or narrow channel. This paper clarifies the technique of the anchor dredging known as a common sense for. the seafarers A mathematical model at low speed range is established for the estimation of ship motion under the assumed environment, simulate the advance speed , and turning ability under the anchor dredging or not. The results shows good agreement with the conventional seamanship and their experiences as follows. Ahead speed used the anchor dredging is slower(speed reduction ratio:40%) than the normal ahead speed and the stopping distance is shorter (distance reduction ratio:40%)than the normal ahead distance without the anchor dredging.. Turning speed used anchor dredging is slower(speed reduction ratio:72%)than the normal ahead speed and the tactical diameter is shorter(distance reduction ratio:24%)than the diameter by the normal turning without the anchor dredging.

  • PDF

한국형 고속전철의 350Km/h 주행에 대한 진동 가속도 분석 (Analysis of the Dynamic Vibration for Korean High Speed Train at Speed 350 Km/h)

  • 박찬경;김기환;목진용;김영국;김석원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.467-472
    • /
    • 2005
  • The characteristics of dynamic vibration are generally analyzed by an acceleration of a car body of high speed train and the acceleration can be applied to evaluation of running safety. The test of process and the analysis method about it are well explained on UIC Code 518 OR which is the spacial international standard about running safety and dynamic behavior on the line test for railway vehicle. Korean High Speed Train designed to operate at speed 350km/h has been tested on high speed line since it was developed in 2002 and it recorded the highest speed 352.4km/h at the 16th Dec. 2004 in Korea. This paper includes the analysis of running behavior of this train at speed 350km/h and also the analysis of dynamic safety is presented in it, extending to the range of high speed while the UIC 518 limit the speed below 200km/h.

  • PDF