• Title/Summary/Keyword: Range Measurement

Search Result 4,359, Processing Time 0.035 seconds

Four Degree-of-Freedom Geometric Error Measurement System with Common-Path Compensation for Laser Beam Drift

  • Qibo, Feng;Bin, Zhang;Cuifang, Kuang
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.26-31
    • /
    • 2008
  • A precision four-degree-of-freedom measurement system has been developed for simultaneous measurement of four motion errors of a linear stage, which include straightness and angular errors, The system employs a retro-reflector to detect the straightness errors and a plane mirror to detect the angular errors. A common-path compensation method for laser beam drift is put forward, and the experimental results show that the influences of beam drift on four motion errors can be reduced simultaneously. In comparison with the API 5D laser measuring system, the accuracy for straightness measurement is about ${\pm}1.5{\mu}m$ within the measuring range of ${\pm}650{\mu}m$, and the accuracy for pitch and yaw measurements is about ${\pm}1.5$ arc-seconds within the range of ${\pm}600$ arc-seconds.

Multi-function Wattmeter for Voltage, Current, and Power Measurement (정밀전압, 전류, 전력측정 다기능전력계)

  • Park, Yeong-Tae;Yu, Gwon-Sang;Jang, Seok-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.10
    • /
    • pp.568-572
    • /
    • 2002
  • High precision voltages, currents, and electrical power measurements in wide range of frequency can be achieved by using the thermo-elements(thermal converters). This paper describes a development wattmeter, based on a thermal principle. The instrument has been performed measurement in the range of currents from 0 to 50 A, voltages up to 480 V, power factor 0.5 (lag, lead), 1 and frequencies from 60 Hz to 3 KHz. It is intended to be used by electric utilities, standard laboratories, testing laboratories, and applications where high measurement accuracy are attractive consideration.

Analysis of Stone′s Surface Roughness Measurement Accuracy of a High Resolution Digital Camera by Digital Close-Range Photogrammetry (수치근접사진측량에 의한 고해상도 디지털 카메라의 석재표면 거칠기 측정정확도 파악)

  • 안기원;이효성;유주현
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.18 no.2
    • /
    • pp.135-141
    • /
    • 2000
  • This study aims to analyze stone's surface roughness measurement accuracy of a high resolution DCS 420 digital camera by digital close-range photogrammetric technique. For this purpose, the surface roughness measurement system was constructed by means of microsoft visual basic 6.0 in windows. As the analysis results of measurement accuracy of digital camera using this system, the roughness error of the normal distance between the best fitting reference surface obtained by least square method and sample points in the ideal plane or surface did not exceed $\pm$0.1 mm

  • PDF

A Comparison of Reliability and Anterior Glide Distance of Humerus Head of Passive Shoulder Internal Rotation Range of Motion Measurement Methods (어깨관절의 수동적 내회전 관절 가동범위의 측정 방법에 따른 신뢰도와 상완골두의 전방 활주 거리 비교)

  • Kim, Hyun-Sook;Lee, Won-Hwee;Choung, Sung-Dae
    • Physical Therapy Korea
    • /
    • v.17 no.3
    • /
    • pp.1-10
    • /
    • 2010
  • The purpose of this study was to measure intra-rater and inter-rater reliability and range of motion for measurement of passive shoulder internal rotation range of motion and to compare anterior glide distance of humeral head in three methods. Fifty healthy subjects and fifty patients with shoulder musculoskeletal pain were recruited for this study. The subjects' passive shoulder internal rotation range of motion was measured by visual estimation, manual stabilization, and pressure biofeedback unit methods. In two trials, measurements were performed on each subject by two examiners. Intraclass correlation coefficient (ICC(3,1)) was used to determine the reliability of each measurement. The intra-rater reliability of the three methods was excellent (ICC=.77~.93) in both groups. The inter-rater reliability of the visual estimation method was poor (ICC=.20, .29), the manual scapular stabilization method was poor and fair (ICC=.09, .50), and the pressure biofeedback unit method was excellent (ICC .86, .75) in the experimental and control groups. In the experimental group, the difference of examined range of motion by each examiner was significant in the visual estimation method and manual scapular stabilization method, but there was an insignificant difference between the groups is the pressure biofeedback unit method. This result suggests that the intra-rater and inter-rater reliability of a pressure biofeedback unit was better than the other methods. The difference in distance of the anterior glide of humeral head was insignificant among all the methods. The pressure biofeedback unit method was the most reliable method, so it is proposed to be a new and reliable method to measure internal rotation range of motion.

Difference in Muscle Activity of Deltoid Muscle according to Isokinetic Range of Motion Using Proprioceptive Neuromuscular Facilitation Pattern of Upper Extremity

  • Rhee, Min-Hyung;Choi, Su-Hong;Lee, Sang-Yeol;Ha, Kyung-Jin;Yoon, Sung-Young
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.5
    • /
    • pp.278-281
    • /
    • 2022
  • Purpose: This study sought to compare the muscle activity of the deltoid muscle according to the range of motion during the proprioceptive neuromuscular facilitation (PNF) upper extremity D2 pattern exercise performed with an isokinetic exercise device. The aim was to provide basic data for selecting an exercise for the relevant segment of the range of motion to enhance function in clinical practice. Methods: In this study, the relevant measurements of the anterior and middle trapezius of 25 healthy adults were taken using a surface electromyography system. The upper extremity pattern exercise was performed in three ranges (0% to 50%, 50% to 100%, and 25% to 75%) using the upper extremity isokinetic device. Results: There was a statistically significant difference in the muscle activity ratios of the anterior and middle deltoid muscles according to the measurement conditions (p<0.05). There was a statistically significant difference in the activity ratio of the middle deltoid muscle according to the measurement conditions in the ratio from the start range to the end range (p<0.05). There was no significant difference in the muscle onset time difference according to the measurement conditions (p>0.05). Conclusion: The muscle activity of the anterior and middle deltoid muscles was analyzed according to the range of motion during the PNF upper extremity pattern exercise performed with an isokinetic device. The results could be used as a basis for selecting exercises for the relevant segment of the range of motion according to the function to be emphasized.

The Immediate Effect of Wrist Joint Mobilization with Taping on Range of Motion, Grip Strength, Spasticity in Stroke Patients

  • Park, Shin-Jun;Youn, Pong-Sub
    • The Journal of Korean Physical Therapy
    • /
    • v.29 no.4
    • /
    • pp.187-193
    • /
    • 2017
  • Purpose: The purpose of this study was to confirm the immediate effect of wrist joint mobilization with taping on the range of motion, grip strength, and spasticity. Methods: Thirty stroke patients were randomly divided into two groups: the joint mobilization with taping group (n=15) and a taping group (n=15). For measurement of spasticity and joint range of motion, the modified Tardieu scale, active and passive range of motion of wrist flexion, as well as extension were measured by the Rapael smart glove, and for grip strength measurement, grip dynamometer was performed. Results: The experimental group showed a significant improvement in the range of motion, grip strength, and spasticity after 10 minutes of taping (p<0.05), no significant difference was found in the control group (p>0.05). However, there was no significant difference between the two groups (p>0.05). Conclusion: The study found that wrist joint mobilization with taping has an immediate effect on wrist range of motion, grip strength, and spasticity in stroke patients, whereas it was not effective in the control group with just taping. The long-term change still needs to be evaluated, when taking into consideration of the carryover effect.

Abdominal Wall Motion-Based Respiration Rate Measurement using An Ultrasonic Proximity Sensor (복부 움직임에 따른 초음파 근접센서를 이용한 호흡측정에 관한 연구)

  • Min, Se-Dong;Kim, Jin-Kwon;Shin, Hang-Sik;Yun, Young-Hyun;Lee, Chung-Keun;Lee, Jeong-Whan;Lee, Myoung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2071-2078
    • /
    • 2009
  • In this paper, we proposed a non-contact respiration measurement system with ultrasonic proximity sensor. Ultrasonic proximity sensor approach of respiration measurement which respiration signatures and rates can be derived in real-time for long-term monitoring is presented. 240 kHz ultrasonic sensor has been applied for the proposed measurement system. The time of flight of sound wave between the transmitted signal and received signal have been used for a respiration measurement from abdominal area. Respiration rates measured with the ultrasonic proximity sensor were compared with those measured with standard techniques on 5 human subjects. Accurate measurement of respiration rate is shown from the 50 cm measurement distance. The data from the method comparison study is used to confirm the performance of the proposed measurement system. The current version of respiratory rate detection system using ultrasonic can successfully measure respiration rate. The proposed measurement method could be used for monitoring unconscious persons from a relatively close range, avoiding the need to apply electrodes or other sensors in the correct position and to wire the subject to the monitor. Monitoring respiration using ultrasonic sensor offers a promising possibility of non-contact measurement of respiration rates. Especially, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range of the measurement and quality of the rate-finding for broadening the potential application areas of this technology.

A Study on the Development of Capacitive Transducer for Measurement of Small Displacement (미소변위 측정용 전기용량변환기 개발에 관한 연구)

  • 박영태;이래덕
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.5
    • /
    • pp.762-768
    • /
    • 1987
  • The capacitive transducers, which are used of the principle of capacitance changes by means of the variation of distance between electrodes, are usually utilized for measurement of small displacements. But the measurement ranges of this method are limited. In this study, the measurement ranges are extended by using the variation method of the surface area of electrodes. Thus the capacitive transducer and signal conditioner, which are having the capability of measurement range of 25mm and resolution of 0.1\ulcorner, have developed, and its environmental characteristics are also tested.

  • PDF

Introduction On the Importance of Engineering Survey in Project Management

  • Meng, Yanlei;Chen, Guiming
    • International conference on construction engineering and project management
    • /
    • 2017.10a
    • /
    • pp.260-262
    • /
    • 2017
  • During the construction of the project, all surveying and mapping work is collectively referred to as engineering survey. Therefore, the measurement work contains a wide range of content, in the engineering survey, design and construction management stage are involved. To the actual work, the project measurement runs through the project building in a number of stages, and provide basic services. This paper mainly through the analysis of engineering measurement at all stages of the role played by the measurement work in the project management work to do the following description.

  • PDF